Name | 08396949_48_1 |
Workunit | 8545793 |
Created | 14 Jul 2021, 19:59:21 UTC |
Sent | 14 Jul 2021, 19:59:38 UTC |
Report deadline | 19 Jul 2021, 19:59:38 UTC |
Received | 14 Jul 2021, 21:01:00 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | -2147467259 (0x80004005) Unknown error code |
Computer ID | 12285 |
Run time | 56 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 1.00 GFLOPS |
Application version | boinc2docker v1.14 (vbox64_mt) windows_x86_64 |
Peak working set size | 10.95 MB |
Peak swap size | 6.23 MB |
Peak disk usage | 499.02 MB |
<core_client_version>7.16.11</core_client_version> <![CDATA[ <message> Unspecified error (0x80004005) - exit code 2147500037 (0x80004005)</message> <stderr_txt> 2021-07-14 22:00:52 (537712): Detected: vboxwrapper 26202 2021-07-14 22:00:52 (537712): Detected: BOINC client v7.16.11 2021-07-14 22:00:53 (537712): Detected: VirtualBox VboxManage Interface (Version: 6.1.12) 2021-07-14 22:00:54 (537712): Create VM. (boinc_11b766be3eed2f33, slot#23) 2021-07-14 22:00:54 (537712): Updating drive controller type and model for desired configuration. 2021-07-14 22:00:54 (537712): Setting Memory Size for VM. (3072MB) 2021-07-14 22:00:55 (537712): Setting CPU Count for VM. (1) 2021-07-14 22:00:55 (537712): Setting Chipset Options for VM. 2021-07-14 22:00:55 (537712): Setting Boot Options for VM. 2021-07-14 22:00:56 (537712): Setting Network Configuration for NAT. 2021-07-14 22:00:56 (537712): Enabling VM Network Access. 2021-07-14 22:00:56 (537712): Disabling USB Support for VM. 2021-07-14 22:00:57 (537712): Disabling COM Port Support for VM. 2021-07-14 22:00:58 (537712): Disabling LPT Port Support for VM. 2021-07-14 22:00:58 (537712): Disabling Audio Support for VM. 2021-07-14 22:00:59 (537712): Disabling Clipboard Support for VM. 2021-07-14 22:00:59 (537712): Disabling Drag and Drop Support for VM. 2021-07-14 22:01:00 (537712): Adding storage controller(s) to VM. 2021-07-14 22:01:00 (537712): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso) 2021-07-14 22:01:01 (537712): Adding VirtualBox Guest Additions to VM. 2021-07-14 22:01:01 (537712): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2021-07-14 22:01:01 (537712): Enabling shared directory for VM. 2021-07-14 22:01:13 (537712): Starting VM using VBoxManage interface. (boinc_11b766be3eed2f33, slot#23) 2021-07-14 22:01:23 (537712): Error in start VM for VM: -2147467259 Command: VBoxManage -q startvm "boinc_11b766be3eed2f33" --type headless Output: Waiting for VM "boinc_11b766be3eed2f33" to power on... VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: AMD-V is disabled in the BIOS (or by the host OS) (VERR_SVM_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2021-07-14 22:01:23 (537712): VM failed to start. 2021-07-14 22:01:23 (537712): Could not start 2021-07-14 22:01:23 (537712): ERROR: VM failed to start 2021-07-14 22:01:26 (537712): Powering off VM. 2021-07-14 22:01:26 (537712): Deregistering VM. (boinc_11b766be3eed2f33, slot#23) 2021-07-14 22:01:33 (537712): Removing network bandwidth throttle group from VM. 2021-07-14 22:01:35 (537712): Removing VM from VirtualBox. 2021-07-14 22:01:35 (537712): Removing virtual ISO 9660 disk from VirtualBox. Hypervisor System Log: 00:00:43.428901 Saving settings file "C:\Users\raven\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:43.772149 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:43.772982 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:43.774316 Saving settings file "A:\Boinc\Data\slots\26\boinc_a10c723afaf7ddd4\boinc_a10c723afaf7ddd4.vbox" with version "1.16-windows" 00:00:43.948151 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:43.950495 Saving settings file "A:\Boinc\Data\slots\27\boinc_8f4081e39cb23d01\boinc_8f4081e39cb23d01.vbox" with version "1.16-windows" 00:00:43.978275 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:44.079837 Saving settings file "A:\Boinc\Data\slots\20\boinc_4868c3c1edb45491\boinc_4868c3c1edb45491.vbox" with version "1.16-windows" 00:00:44.121911 Saving settings file "A:\Boinc\Data\slots\18\boinc_4031cbd701d00aeb\boinc_4031cbd701d00aeb.vbox" with version "1.16-windows" 00:00:44.392274 Saving settings file "A:\Boinc\Data\slots\19\boinc_46cd81a8c3fe4a12\boinc_46cd81a8c3fe4a12.vbox" with version "1.16-windows" 00:00:44.737785 Saving settings file "C:\Users\raven\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:45.197310 Saving settings file "A:\Boinc\Data\slots\22\boinc_85d481288dbc6efe\boinc_85d481288dbc6efe.vbox" with version "1.16-windows" 00:00:45.362528 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:45.373901 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:45.374754 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:45.384701 Saving settings file "A:\Boinc\Data\slots\26\boinc_a10c723afaf7ddd4\boinc_a10c723afaf7ddd4.vbox" with version "1.16-windows" 00:00:45.412429 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:45.578909 Saving settings file "C:\Users\raven\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:45.681950 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:45.756951 Launched VM: 81886832 pid: 538140 (0x8361c) frontend: headless name: boinc_4868c3c1edb45491 00:00:45.762703 Saving settings file "A:\Boinc\Data\slots\26\boinc_a10c723afaf7ddd4\boinc_a10c723afaf7ddd4.vbox" with version "1.16-windows" 00:00:45.772191 Saving settings file "A:\Boinc\Data\slots\27\boinc_8f4081e39cb23d01\boinc_8f4081e39cb23d01.vbox" with version "1.16-windows" 00:00:45.781744 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={Could not find a registered machine named 'boinc_b608308bc20b7688'}, preserve=false aResultDetail=0 00:00:45.811169 Saving settings file "A:\Boinc\Data\slots\21\boinc_5f9a9489b47c234a\boinc_5f9a9489b47c234a.vbox" with version "1.16-windows" 00:00:45.812818 Saving settings file "A:\Boinc\Data\slots\22\boinc_85d481288dbc6efe\boinc_85d481288dbc6efe.vbox" with version "1.16-windows" 00:00:45.971294 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:46.060188 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:46.060637 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:46.071450 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:46.110199 Saving settings file "C:\Users\raven\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:46.114847 ERROR [COM]: aRC=VBOX_E_FILE_ERROR (0x80bb0004) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Could not find file for the medium 'A:\Boinc\Data\slots\24\vm_image.vdi' (VERR_FILE_NOT_FOUND)}, preserve=false aResultDetail=-102 00:00:46.224896 Saving settings file "A:\Boinc\Data\slots\21\boinc_5f9a9489b47c234a\boinc_5f9a9489b47c234a.vbox" with version "1.16-windows" 00:00:46.248029 Saving settings file "C:\Users\raven\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:49.596196 Saving settings file "A:\Boinc\Data\slots\24\boinc_b608308bc20b7688\boinc_b608308bc20b7688.vbox" with version "1.16-windows" 00:00:49.601417 Saving settings file "C:\Users\raven\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:49.760338 Launched VM: 81369120 pid: 531168 (0x81ae0) frontend: headless name: boinc_a10c723afaf7ddd4 00:00:49.850312 Saving settings file "C:\Users\raven\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:49.971400 Saving settings file "A:\Boinc\Data\slots\24\boinc_b608308bc20b7688\boinc_b608308bc20b7688.vbox" with version "1.16-windows" 00:00:50.668830 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={Could not find a registered machine named 'boinc_d49dffeeea339685'}, preserve=false aResultDetail=0 00:00:51.200435 Saving settings file "A:\Boinc\Data\slots\24\boinc_b608308bc20b7688\boinc_b608308bc20b7688.vbox" with version "1.16-windows" 00:00:53.456290 ERROR [COM]: aRC=VBOX_E_FILE_ERROR (0x80bb0004) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Could not find file for the medium 'A:\Boinc\Data\slots\25\vm_image.vdi' (VERR_FILE_NOT_FOUND)}, preserve=false aResultDetail=-102 00:00:53.588293 Saving settings file "A:\Boinc\Data\slots\25\boinc_d49dffeeea339685\boinc_d49dffeeea339685.vbox" with version "1.16-windows" 00:00:53.594522 Saving settings file "C:\Users\raven\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:53.709554 Saving settings file "A:\Boinc\Data\slots\24\boinc_b608308bc20b7688\boinc_b608308bc20b7688.vbox" with version "1.16-windows" VM Execution Log: VM Startup Log: VM Trace Log: DE auth library: VBoxAuth Webservice auth. library: VBoxAuth Remote desktop ExtPack: Log history count: 3 Default frontend: Default audio driver: DirectSound Autostart database path: Default Guest Additions ISO: C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso Logging Level: all Proxy Mode: System Proxy URL: 2021-07-14 22:00:53 (537712): Command: VBoxManage -q list hostinfo Exit Code: 0 Output: Host Information: Host time: 2021-07-14T20:00:53.604000000Z Processor online count: 16 Processor count: 16 Processor online core count: 8 Processor core count: 8 Processor supports HW virtualization: no Processor supports PAE: yes Processor supports long mode: yes Processor supports nested paging: no Processor supports unrestricted guest: no Processor supports nested HW virtualization: no Processor#0 speed: unknown Processor#0 description: AMD Ryzen 7 2700 Eight-Core Processor Processor#1 speed: unknown Processor#1 description: AMD Ryzen 7 2700 Eight-Core Processor Processor#2 speed: unknown Processor#2 description: AMD Ryzen 7 2700 Eight-Core Processor Processor#3 speed: unknown Processor#3 description: AMD Ryzen 7 2700 Eight-Core Processor Processor#4 speed: unknown Processor#4 description: AMD Ryzen 7 2700 Eight-Core Processor Processor#5 speed: unknown Processor#5 description: AMD Ryzen 7 2700 Eight-Core Processor Processor#6 speed: unknown Processor#6 description: AMD Ryzen 7 2700 Eight-Core Processor Processor#7 speed: unknown Processor#7 description: AMD Ryzen 7 2700 Eight-Core Processor Processor#8 speed: unknown Processor#8 description: AMD Ryzen 7 2700 Eight-Core Processor Processor#9 speed: unknown Processor#9 description: AMD Ryzen 7 2700 Eight-Core Processor Processor#10 speed: unknown Processor#10 description: AMD Ryzen 7 2700 Eight-Core Processor Processor#11 speed: unknown Processor#11 description: AMD Ryzen 7 2700 Eight-Core Processor Processor#12 speed: unknown Processor#12 description: AMD Ryzen 7 2700 Eight-Core Processor Processor#13 speed: unknown Processor#13 description: AMD Ryzen 7 2700 Eight-Core Processor Processor#14 speed: unknown Processor#14 description: AMD Ryzen 7 2700 Eight-Core Processor Processor#15 speed: unknown Processor#15 description: AMD Ryzen 7 2700 Eight-Core Processor Memory size: 130997 MByte Memory available: 91501 MByte Operating system: Windows 10 Operating system version: 10.0.19042 2021-07-14 22:00:54 (537712): Command: VBoxManage -q showvminfo "boinc_11b766be3eed2f33" --machinereadable Exit Code: -2135228415 Output: VBoxManage.exe: error: Could not find a registered machine named 'boinc_11b766be3eed2f33' VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2715 of file VBoxManageInfo.cpp 2021-07-14 22:00:54 (537712): Command: VBoxManage -q showhdinfo "A:\Boinc\Data\slots\23/vm_image.vdi" Exit Code: -2135228412 Output: VBoxManage.exe: error: Could not find file for the medium 'A:\Boinc\Data\slots\23\vm_image.vdi' (VERR_FILE_NOT_FOUND) VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp 2021-07-14 22:00:54 (537712): Command: VBoxManage -q createvm --name "boinc_11b766be3eed2f33" --basefolder "A:\Boinc\Data\slots\23" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_11b766be3eed2f33' is created and registered. UUID: 4febe4b1-8f21-451e-b415-903ea8f76fa0 Settings file: 'A:\Boinc\Data\slots\23\boinc_11b766be3eed2f33\boinc_11b766be3eed2f33.vbox' 2021-07-14 22:00:54 (537712): Command: VBoxManage -q modifyvm "boinc_11b766be3eed2f33" --description "08396949_48_1" Exit Code: 0 Output: 2021-07-14 22:00:55 (537712): Command: VBoxManage -q modifyvm "boinc_11b766be3eed2f33" --memory 3072 Exit Code: 0 Output: 2021-07-14 22:00:55 (537712): Command: VBoxManage -q modifyvm "boinc_11b766be3eed2f33" --cpus 1 Exit Code: 0 Output: 2021-07-14 22:00:55 (537712): Command: VBoxManage -q modifyvm "boinc_11b766be3eed2f33" --acpi on --ioapic on Exit Code: 0 Output: 2021-07-14 22:00:56 (537712): Command: VBoxManage -q modifyvm "boinc_11b766be3eed2f33" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2021-07-14 22:00:56 (537712): Command: VBoxManage -q modifyvm "boinc_11b766be3eed2f33" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2021-07-14 22:00:56 (537712): Command: VBoxManage -q modifyvm "boinc_11b766be3eed2f33" --cableconnected1 on Exit Code: 0 Output: 2021-07-14 22:00:57 (537712): Command: VBoxManage -q modifyvm "boinc_11b766be3eed2f33" --usb off Exit Code: 0 Output: 2021-07-14 22:00:58 (537712): Command: VBoxManage -q modifyvm "boinc_11b766be3eed2f33" --uart1 off --uart2 off Exit Code: 0 Output: 2021-07-14 22:00:58 (537712): Command: VBoxManage -q modifyvm "boinc_11b766be3eed2f33" --lpt1 off --lpt2 off Exit Code: 0 Output: 2021-07-14 22:00:59 (537712): Command: VBoxManage -q modifyvm "boinc_11b766be3eed2f33" --audio none Exit Code: 0 Output: 2021-07-14 22:00:59 (537712): Command: VBoxManage -q modifyvm "boinc_11b766be3eed2f33" --clipboard disabled Exit Code: 0 Output: 2021-07-14 22:01:00 (537712): Command: VBoxManage -q modifyvm "boinc_11b766be3eed2f33" --draganddrop disabled Exit Code: 0 Output: 2021-07-14 22:01:00 (537712): Command: VBoxManage -q storagectl "boinc_11b766be3eed2f33" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2021-07-14 22:01:01 (537712): Command: VBoxManage -q storageattach "boinc_11b766be3eed2f33" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "A:\Boinc\Data\slots\23/vm_isocontext.iso" Exit Code: 0 Output: 2021-07-14 22:01:01 (537712): Command: VBoxManage -q storageattach "boinc_11b766be3eed2f33" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2021-07-14 22:01:01 (537712): Command: VBoxManage -q bandwidthctl "boinc_11b766be3eed2f33" add "boinc_11b766be3eed2f33_net" --type network --limit 1024G Exit Code: 0 Output: 2021-07-14 22:01:08 (537712): Command: VBoxManage -q sharedfolder add "boinc_11b766be3eed2f33" --name "shared" --hostpath "A:\Boinc\Data\slots\23/shared" Exit Code: 0 Output: 2021-07-14 22:01:22 (537712): Command: VBoxManage -q startvm "boinc_11b766be3eed2f33" --type headless Exit Code: -2147467259 Output: Waiting for VM "boinc_11b766be3eed2f33" to power on... VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: AMD-V is disabled in the BIOS (or by the host OS) (VERR_SVM_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2021-07-14 22:01:33 (537712): Command: VBoxManage -q snapshot "boinc_11b766be3eed2f33" list Exit Code: -108 Output: This machine does not have any snapshots 2021-07-14 22:01:35 (537712): Command: VBoxManage -q bandwidthctl "boinc_11b766be3eed2f33" remove "boinc_11b766be3eed2f33_net" Exit Code: 0 Output: 2021-07-14 22:01:35 (537712): Command: VBoxManage -q unregistervm "boinc_11b766be3eed2f33" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 2021-07-14 22:01:36 (537712): Command: VBoxManage -q closemedium dvd "A:\Boinc\Data\slots\23/vm_isocontext.iso" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 22:01:47 (537712): called boinc_finish(-2147467259) </stderr_txt> ]]>
©2025 COPYRIGHT 2017-2018 NCN