Name | 07998281_27_0 |
Workunit | 7874976 |
Created | 16 Oct 2020, 22:42:55 UTC |
Sent | 17 Oct 2020, 7:11:20 UTC |
Report deadline | 22 Oct 2020, 7:11:20 UTC |
Received | 17 Oct 2020, 9:04:43 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | -2147467259 (0x80004005) Unknown error code |
Computer ID | 4434 |
Run time | 49 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 3.82 GFLOPS |
Application version | boinc2docker v1.14 (vbox64_mt) windows_x86_64 |
Peak working set size | 11.47 MB |
Peak swap size | 6.24 MB |
Peak disk usage | 230.28 MB |
<core_client_version>7.16.11</core_client_version> <![CDATA[ <message> Unbekannter Fehler (0x80004005) - exit code 2147500037 (0x80004005)</message> <stderr_txt> 2020-10-17 10:58:24 (7504): Detected: vboxwrapper 26202 2020-10-17 10:58:24 (7504): Detected: BOINC client v7.16.11 2020-10-17 10:58:25 (7504): Detected: VirtualBox VboxManage Interface (Version: 6.1.12) 2020-10-17 10:58:27 (7504): Create VM. (boinc_a2094d647a92a618, slot#7) 2020-10-17 10:58:27 (7504): Updating drive controller type and model for desired configuration. 2020-10-17 10:58:29 (7504): Setting Memory Size for VM. (3072MB) 2020-10-17 10:58:29 (7504): Setting CPU Count for VM. (1) 2020-10-17 10:58:30 (7504): Setting Chipset Options for VM. 2020-10-17 10:58:30 (7504): Setting Boot Options for VM. 2020-10-17 10:58:31 (7504): Setting Network Configuration for NAT. 2020-10-17 10:58:31 (7504): Enabling VM Network Access. 2020-10-17 10:58:32 (7504): Disabling USB Support for VM. 2020-10-17 10:58:32 (7504): Disabling COM Port Support for VM. 2020-10-17 10:58:33 (7504): Disabling LPT Port Support for VM. 2020-10-17 10:58:34 (7504): Disabling Audio Support for VM. 2020-10-17 10:58:35 (7504): Disabling Clipboard Support for VM. 2020-10-17 10:58:35 (7504): Disabling Drag and Drop Support for VM. 2020-10-17 10:58:36 (7504): Adding storage controller(s) to VM. 2020-10-17 10:58:38 (7504): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso) 2020-10-17 10:58:40 (7504): Adding VirtualBox Guest Additions to VM. 2020-10-17 10:58:41 (7504): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2020-10-17 10:58:43 (7504): Enabling shared directory for VM. 2020-10-17 10:58:47 (7504): Starting VM using VBoxManage interface. (boinc_a2094d647a92a618, slot#7) 2020-10-17 10:58:55 (7504): Error in start VM for VM: -2147467259 Command: VBoxManage -q startvm "boinc_a2094d647a92a618" --type headless Output: Waiting for VM "boinc_a2094d647a92a618" to power on... VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2020-10-17 10:58:55 (7504): VM failed to start. 2020-10-17 10:58:55 (7504): Could not start 2020-10-17 10:58:55 (7504): ERROR: VM failed to start 2020-10-17 10:58:55 (7504): Powering off VM. 2020-10-17 10:58:55 (7504): Deregistering VM. (boinc_a2094d647a92a618, slot#7) 2020-10-17 10:58:56 (7504): Removing network bandwidth throttle group from VM. 2020-10-17 10:58:58 (7504): Removing VM from VirtualBox. 2020-10-17 10:58:59 (7504): Removing virtual ISO 9660 disk from VirtualBox. Hypervisor System Log: 00:03:57.320902 Saving settings file "H:\BOINC2\DaTa\slots\4\boinc_a47339db73f1eab6\boinc_a47339db73f1eab6.vbox" with version "1.16-windows" 00:03:57.444015 Saving settings file "H:\BOINC2\DaTa\slots\8\boinc_a862a71195296862\boinc_a862a71195296862.vbox" with version "1.16-windows" 00:03:58.152326 Saving settings file "H:\BOINC2\DaTa\slots\4\boinc_a47339db73f1eab6\boinc_a47339db73f1eab6.vbox" with version "1.16-windows" 00:03:58.179934 Saving settings file "H:\BOINC2\DaTa\slots\8\boinc_a862a71195296862\boinc_a862a71195296862.vbox" with version "1.16-windows" 00:03:59.419536 Saving settings file "H:\BOINC2\DaTa\slots\4\boinc_a47339db73f1eab6\boinc_a47339db73f1eab6.vbox" with version "1.16-windows" 00:03:59.808750 Saving settings file "H:\BOINC2\DaTa\slots\8\boinc_a862a71195296862\boinc_a862a71195296862.vbox" with version "1.16-windows" 00:04:00.503242 Saving settings file "H:\BOINC2\DaTa\slots\4\boinc_a47339db73f1eab6\boinc_a47339db73f1eab6.vbox" with version "1.16-windows" 00:04:00.648550 Saving settings file "H:\BOINC2\DaTa\slots\7\boinc_a2094d647a92a618\boinc_a2094d647a92a618.vbox" with version "1.16-windows" 00:04:01.502783 Saving settings file "H:\BOINC2\DaTa\slots\8\boinc_a862a71195296862\boinc_a862a71195296862.vbox" with version "1.16-windows" 00:04:02.064991 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:04:02.066589 Saving settings file "H:\BOINC2\DaTa\slots\4\boinc_a47339db73f1eab6\boinc_a47339db73f1eab6.vbox" with version "1.16-windows" 00:04:02.889554 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={Could not find a registered machine named 'boinc_a98418c968de92b4'}, preserve=false aResultDetail=0 00:04:03.626861 Saving settings file "H:\BOINC2\DaTa\slots\7\boinc_a2094d647a92a618\boinc_a2094d647a92a618.vbox" with version "1.16-windows" 00:04:03.814330 ERROR [COM]: aRC=VBOX_E_FILE_ERROR (0x80bb0004) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Could not find file for the medium 'H:\BOINC2\DaTa\slots\6\vm_image.vdi' (VERR_FILE_NOT_FOUND)}, preserve=false aResultDetail=-102 00:04:04.791332 Saving settings file "H:\BOINC2\DaTa\slots\6\boinc_a98418c968de92b4\boinc_a98418c968de92b4.vbox" with version "1.16-windows" 00:04:04.796936 Saving settings file "H:\BOINC2\DaTa\slots\8\boinc_a862a71195296862\boinc_a862a71195296862.vbox" with version "1.16-windows" 00:04:04.797797 Saving settings file "H:\BOINC2\DaTa\slots\4\boinc_a47339db73f1eab6\boinc_a47339db73f1eab6.vbox" with version "1.16-windows" 00:04:05.738743 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={Could not find a registered machine named 'boinc_b177589c9edd7934'}, preserve=false aResultDetail=0 00:04:05.738858 Saving settings file "C:\Users\bonsai\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:04:05.745657 Saving settings file "C:\Users\bonsai\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:04:06.692282 Saving settings file "H:\BOINC2\DaTa\slots\8\boinc_a862a71195296862\boinc_a862a71195296862.vbox" with version "1.16-windows" 00:04:06.802152 Saving settings file "H:\BOINC2\DaTa\slots\4\boinc_a47339db73f1eab6\boinc_a47339db73f1eab6.vbox" with version "1.16-windows" 00:04:06.829541 ERROR [COM]: aRC=VBOX_E_FILE_ERROR (0x80bb0004) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Could not find file for the medium 'H:\BOINC2\DaTa\slots\3\vm_image.vdi' (VERR_FILE_NOT_FOUND)}, preserve=false aResultDetail=-102 00:04:07.840930 Saving settings file "H:\BOINC2\DaTa\slots\6\boinc_a98418c968de92b4\boinc_a98418c968de92b4.vbox" with version "1.16-windows" 00:04:08.456420 Saving settings file "H:\BOINC2\DaTa\slots\3\boinc_b177589c9edd7934\boinc_b177589c9edd7934.vbox" with version "1.16-windows" 00:04:08.712003 Saving settings file "H:\BOINC2\DaTa\slots\4\boinc_a47339db73f1eab6\boinc_a47339db73f1eab6.vbox" with version "1.16-windows" 00:04:09.676731 Saving settings file "C:\Users\bonsai\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:04:09.680311 Saving settings file "H:\BOINC2\DaTa\slots\6\boinc_a98418c968de92b4\boinc_a98418c968de92b4.vbox" with version "1.16-windows" 00:04:09.681062 Saving settings file "H:\BOINC2\DaTa\slots\8\boinc_a862a71195296862\boinc_a862a71195296862.vbox" with version "1.16-windows" 00:04:10.353872 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={Could not find a registered machine named 'boinc_b4eeae7f595034a8'}, preserve=false aResultDetail=0 00:04:10.358758 Saving settings file "H:\BOINC2\DaTa\slots\3\boinc_b177589c9edd7934\boinc_b177589c9edd7934.vbox" with version "1.16-windows" 00:04:11.047113 Saving settings file "H:\BOINC2\DaTa\slots\6\boinc_a98418c968de92b4\boinc_a98418c968de92b4.vbox" with version "1.16-windows" 00:04:11.120106 Saving settings file "H:\BOINC2\DaTa\slots\8\boinc_a862a71195296862\boinc_a862a71195296862.vbox" with version "1.16-windows" 00:04:11.363746 ERROR [COM]: aRC=VBOX_E_FILE_ERROR (0x80bb0004) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Could not find file for the medium 'H:\BOINC2\DaTa\slots\5\vm_image.vdi' (VERR_FILE_NOT_FOUND)}, preserve=false aResultDetail=-102 00:04:11.369913 Saving settings file "H:\BOINC2\DaTa\slots\4\boinc_a47339db73f1eab6\boinc_a47339db73f1eab6.vbox" with version "1.16-windows" 00:04:11.896185 Saving settings file "H:\BOINC2\DaTa\slots\5\boinc_b4eeae7f595034a8\boinc_b4eeae7f595034a8.vbox" with version "1.16-windows" 00:04:12.475247 Saving settings file "H:\BOINC2\DaTa\slots\3\boinc_b177589c9edd7934\boinc_b177589c9edd7934.vbox" with version "1.16-windows" 00:04:13.110285 Saving settings file "C:\Users\bonsai\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:04:13.909559 Saving settings file "H:\BOINC2\DaTa\slots\4\boinc_a47339db73f1eab6\boinc_a47339db73f1eab6.vbox" with version "1.16-windows" 00:04:14.773769 Saving settings file "H:\BOINC2\DaTa\slots\5\boinc_b4eeae7f595034a8\boinc_b4eeae7f595034a8.vbox" with version "1.16-windows" 00:04:14.773795 Saving settings file "H:\BOINC2\DaTa\slots\8\boinc_a862a71195296862\boinc_a862a71195296862.vbox" with version "1.16-windows" 00:04:14.773816 Saving settings file "H:\BOINC2\DaTa\slots\3\boinc_b177589c9edd7934\boinc_b177589c9edd7934.vbox" with version "1.16-windows" 00:04:14.774223 Saving settings file "H:\BOINC2\DaTa\slots\6\boinc_a98418c968de92b4\boinc_a98418c968de92b4.vbox" with version "1.16-windows" 00:04:15.488598 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:04:15.489975 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:04:15.779944 Saving settings file "C:\Users\bonsai\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:04:15.786352 Saving settings file "C:\Users\bonsai\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:04:15.794231 Saving settings file "H:\BOINC2\DaTa\slots\4\boinc_a47339db73f1eab6\boinc_a47339db73f1eab6.vbox" with version "1.16-windows" VM Execution Log: VM Startup Log: VM Trace Log: lers: 1 Maximum SAS ICH9 Controllers: 8 Maximum SAS Port count: 255 Maximum Devices per SAS Port: 1 Maximum NVMe PIIX3 Controllers: 1 Maximum NVMe ICH9 Controllers: 8 Maximum NVMe Port count: 255 Maximum Devices per NVMe Port: 1 Maximum virtio-scsi PIIX3 Controllers: 1 Maximum virtio-scsi ICH9 Controllers: 8 Maximum virtio-scsi Port count: 256 Maximum Devices per virtio-scsi Port: 1 Maximum PIIX3 Floppy Controllers:1 Maximum ICH9 Floppy Controllers: 1 Maximum Floppy Port count: 1 Maximum Devices per Floppy Port: 2 Default machine folder: C:\Users\bonsai\VirtualBox VMs Raw-mode Supported: no Exclusive HW virtualization use: off Default hard disk format: VDI VRDE auth library: VBoxAuth Webservice auth. library: VBoxAuth Remote desktop ExtPack: Log history count: 3 Default frontend: Default audio driver: DirectSound Autostart database path: Default Guest Additions ISO: C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso Logging Level: all Proxy Mode: System Proxy URL: 2020-10-17 10:58:26 (7504): Command: VBoxManage -q list hostinfo Exit Code: 0 Output: Host Information: Host time: 2020-10-17T08:58:26.143000000Z Processor online count: 8 Processor count: 8 Processor online core count: 4 Processor core count: 4 Processor supports HW virtualization: no Processor supports PAE: yes Processor supports long mode: yes Processor supports nested paging: no Processor supports unrestricted guest: no Processor supports nested HW virtualization: no Processor#0 speed: unknown Processor#0 description: Intel(R) Xeon(R) CPU E3-1231 v3 @ 3.40GHz Processor#1 speed: unknown Processor#1 description: Intel(R) Xeon(R) CPU E3-1231 v3 @ 3.40GHz Processor#2 speed: unknown Processor#2 description: Intel(R) Xeon(R) CPU E3-1231 v3 @ 3.40GHz Processor#3 speed: unknown Processor#3 description: Intel(R) Xeon(R) CPU E3-1231 v3 @ 3.40GHz Processor#4 speed: unknown Processor#4 description: Intel(R) Xeon(R) CPU E3-1231 v3 @ 3.40GHz Processor#5 speed: unknown Processor#5 description: Intel(R) Xeon(R) CPU E3-1231 v3 @ 3.40GHz Processor#6 speed: unknown Processor#6 description: Intel(R) Xeon(R) CPU E3-1231 v3 @ 3.40GHz Processor#7 speed: unknown Processor#7 description: Intel(R) Xeon(R) CPU E3-1231 v3 @ 3.40GHz Memory size: 16325 MByte Memory available: 9150 MByte Operating system: Windows 10 Operating system version: 10.0.19041 2020-10-17 10:58:27 (7504): Command: VBoxManage -q showvminfo "boinc_a2094d647a92a618" --machinereadable Exit Code: -2135228415 Output: VBoxManage.exe: error: Could not find a registered machine named 'boinc_a2094d647a92a618' VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2715 of file VBoxManageInfo.cpp 2020-10-17 10:58:27 (7504): Command: VBoxManage -q showhdinfo "H:\BOINC2\DaTa\slots\7/vm_image.vdi" Exit Code: -2135228412 Output: VBoxManage.exe: error: Could not find file for the medium 'H:\BOINC2\DaTa\slots\7\vm_image.vdi' (VERR_FILE_NOT_FOUND) VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp 2020-10-17 10:58:28 (7504): Command: VBoxManage -q createvm --name "boinc_a2094d647a92a618" --basefolder "H:\BOINC2\DaTa\slots\7" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_a2094d647a92a618' is created and registered. UUID: 93fe5fb0-dd09-4302-a20b-a4998a185433 Settings file: 'H:\BOINC2\DaTa\slots\7\boinc_a2094d647a92a618\boinc_a2094d647a92a618.vbox' 2020-10-17 10:58:29 (7504): Command: VBoxManage -q modifyvm "boinc_a2094d647a92a618" --description "07998281_27_0" Exit Code: 0 Output: 2020-10-17 10:58:29 (7504): Command: VBoxManage -q modifyvm "boinc_a2094d647a92a618" --memory 3072 Exit Code: 0 Output: 2020-10-17 10:58:30 (7504): Command: VBoxManage -q modifyvm "boinc_a2094d647a92a618" --cpus 1 Exit Code: 0 Output: 2020-10-17 10:58:30 (7504): Command: VBoxManage -q modifyvm "boinc_a2094d647a92a618" --acpi on --ioapic on Exit Code: 0 Output: 2020-10-17 10:58:31 (7504): Command: VBoxManage -q modifyvm "boinc_a2094d647a92a618" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2020-10-17 10:58:31 (7504): Command: VBoxManage -q modifyvm "boinc_a2094d647a92a618" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2020-10-17 10:58:32 (7504): Command: VBoxManage -q modifyvm "boinc_a2094d647a92a618" --cableconnected1 on Exit Code: 0 Output: 2020-10-17 10:58:32 (7504): Command: VBoxManage -q modifyvm "boinc_a2094d647a92a618" --usb off Exit Code: 0 Output: 2020-10-17 10:58:33 (7504): Command: VBoxManage -q modifyvm "boinc_a2094d647a92a618" --uart1 off --uart2 off Exit Code: 0 Output: 2020-10-17 10:58:34 (7504): Command: VBoxManage -q modifyvm "boinc_a2094d647a92a618" --lpt1 off --lpt2 off Exit Code: 0 Output: 2020-10-17 10:58:35 (7504): Command: VBoxManage -q modifyvm "boinc_a2094d647a92a618" --audio none Exit Code: 0 Output: 2020-10-17 10:58:35 (7504): Command: VBoxManage -q modifyvm "boinc_a2094d647a92a618" --clipboard disabled Exit Code: 0 Output: 2020-10-17 10:58:36 (7504): Command: VBoxManage -q modifyvm "boinc_a2094d647a92a618" --draganddrop disabled Exit Code: 0 Output: 2020-10-17 10:58:38 (7504): Command: VBoxManage -q storagectl "boinc_a2094d647a92a618" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2020-10-17 10:58:40 (7504): Command: VBoxManage -q storageattach "boinc_a2094d647a92a618" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "H:\BOINC2\DaTa\slots\7/vm_isocontext.iso" Exit Code: 0 Output: 2020-10-17 10:58:41 (7504): Command: VBoxManage -q storageattach "boinc_a2094d647a92a618" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2020-10-17 10:58:43 (7504): Command: VBoxManage -q bandwidthctl "boinc_a2094d647a92a618" add "boinc_a2094d647a92a618_net" --type network --limit 1024G Exit Code: 0 Output: 2020-10-17 10:58:46 (7504): Command: VBoxManage -q sharedfolder add "boinc_a2094d647a92a618" --name "shared" --hostpath "H:\BOINC2\DaTa\slots\7/shared" Exit Code: 0 Output: 2020-10-17 10:58:55 (7504): Command: VBoxManage -q startvm "boinc_a2094d647a92a618" --type headless Exit Code: -2147467259 Output: Waiting for VM "boinc_a2094d647a92a618" to power on... VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2020-10-17 10:58:56 (7504): Command: VBoxManage -q snapshot "boinc_a2094d647a92a618" list Exit Code: -108 Output: This machine does not have any snapshots 2020-10-17 10:58:58 (7504): Command: VBoxManage -q bandwidthctl "boinc_a2094d647a92a618" remove "boinc_a2094d647a92a618_net" Exit Code: 0 Output: 2020-10-17 10:58:59 (7504): Command: VBoxManage -q unregistervm "boinc_a2094d647a92a618" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 2020-10-17 10:59:00 (7504): Command: VBoxManage -q closemedium dvd "H:\BOINC2\DaTa\slots\7/vm_isocontext.iso" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 10:59:11 (7504): called boinc_finish(-2147467259) </stderr_txt> ]]>
©2025 COPYRIGHT 2017-2018 NCN