Name | 07998281_46_0 |
Workunit | 7874995 |
Created | 16 Oct 2020, 22:42:55 UTC |
Sent | 17 Oct 2020, 7:11:20 UTC |
Report deadline | 22 Oct 2020, 7:11:20 UTC |
Received | 17 Oct 2020, 9:04:43 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | -2147467259 (0x80004005) Unknown error code |
Computer ID | 4434 |
Run time | 19 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 3.82 GFLOPS |
Application version | boinc2docker v1.14 (vbox64_mt) windows_x86_64 |
Peak working set size | 11.48 MB |
Peak swap size | 6.23 MB |
Peak disk usage | 230.28 MB |
<core_client_version>7.16.11</core_client_version> <![CDATA[ <message> Unbekannter Fehler (0x80004005) - exit code 2147500037 (0x80004005)</message> <stderr_txt> 2020-10-17 11:01:31 (14840): Detected: vboxwrapper 26202 2020-10-17 11:01:31 (14840): Detected: BOINC client v7.16.11 2020-10-17 11:01:32 (14840): Detected: VirtualBox VboxManage Interface (Version: 6.1.12) 2020-10-17 11:01:34 (14840): Create VM. (boinc_f97ecad8a13003af, slot#3) 2020-10-17 11:01:34 (14840): Updating drive controller type and model for desired configuration. 2020-10-17 11:01:36 (14840): Setting Memory Size for VM. (3072MB) 2020-10-17 11:01:37 (14840): Setting CPU Count for VM. (1) 2020-10-17 11:01:39 (14840): Setting Chipset Options for VM. 2020-10-17 11:01:40 (14840): Setting Boot Options for VM. 2020-10-17 11:01:41 (14840): Setting Network Configuration for NAT. 2020-10-17 11:01:42 (14840): Enabling VM Network Access. 2020-10-17 11:01:43 (14840): Disabling USB Support for VM. 2020-10-17 11:01:44 (14840): Disabling COM Port Support for VM. 2020-10-17 11:01:45 (14840): Disabling LPT Port Support for VM. 2020-10-17 11:01:46 (14840): Disabling Audio Support for VM. 2020-10-17 11:01:46 (14840): Disabling Clipboard Support for VM. 2020-10-17 11:01:47 (14840): Disabling Drag and Drop Support for VM. 2020-10-17 11:01:48 (14840): Adding storage controller(s) to VM. 2020-10-17 11:01:49 (14840): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso) 2020-10-17 11:01:50 (14840): Adding VirtualBox Guest Additions to VM. 2020-10-17 11:01:51 (14840): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2020-10-17 11:01:52 (14840): Enabling shared directory for VM. 2020-10-17 11:01:54 (14840): Starting VM using VBoxManage interface. (boinc_f97ecad8a13003af, slot#3) 2020-10-17 11:02:00 (14840): Error in start VM for VM: -2147467259 Command: VBoxManage -q startvm "boinc_f97ecad8a13003af" --type headless Output: Waiting for VM "boinc_f97ecad8a13003af" to power on... VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2020-10-17 11:02:00 (14840): VM failed to start. 2020-10-17 11:02:00 (14840): Could not start 2020-10-17 11:02:00 (14840): ERROR: VM failed to start 2020-10-17 11:02:00 (14840): Powering off VM. 2020-10-17 11:02:00 (14840): Deregistering VM. (boinc_f97ecad8a13003af, slot#3) 2020-10-17 11:02:00 (14840): Removing network bandwidth throttle group from VM. 2020-10-17 11:02:01 (14840): Removing VM from VirtualBox. 2020-10-17 11:02:01 (14840): Removing virtual ISO 9660 disk from VirtualBox. Hypervisor System Log: 00:00:29.703740 Saving settings file "C:\Users\bonsai\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:29.705509 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:29.709771 Saving settings file "C:\Users\bonsai\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:29.715610 Saving settings file "H:\BOINC2\DaTa\slots\8\boinc_f1c5c35ea7576e9b\boinc_f1c5c35ea7576e9b.vbox" with version "1.16-windows" 00:00:29.829174 Saving settings file "H:\BOINC2\DaTa\slots\3\boinc_f97ecad8a13003af\boinc_f97ecad8a13003af.vbox" with version "1.16-windows" 00:00:30.578284 Launched VM: 76658416 pid: 19044 (0x4a64) frontend: headless name: boinc_efadd3e199a90165 00:00:30.582961 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:30.583516 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:30.584157 Saving settings file "H:\BOINC2\DaTa\slots\8\boinc_f1c5c35ea7576e9b\boinc_f1c5c35ea7576e9b.vbox" with version "1.16-windows" 00:00:30.754083 Saving settings file "H:\BOINC2\DaTa\slots\3\boinc_f97ecad8a13003af\boinc_f97ecad8a13003af.vbox" with version "1.16-windows" 00:00:31.567312 Saving settings file "H:\BOINC2\DaTa\slots\8\boinc_f1c5c35ea7576e9b\boinc_f1c5c35ea7576e9b.vbox" with version "1.16-windows" 00:00:31.649894 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:31.651758 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:31.651947 Saving settings file "C:\Users\bonsai\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:31.659008 Saving settings file "C:\Users\bonsai\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:31.665976 Saving settings file "H:\BOINC2\DaTa\slots\3\boinc_f97ecad8a13003af\boinc_f97ecad8a13003af.vbox" with version "1.16-windows" 00:00:32.447365 Saving settings file "H:\BOINC2\DaTa\slots\8\boinc_f1c5c35ea7576e9b\boinc_f1c5c35ea7576e9b.vbox" with version "1.16-windows" 00:00:33.056943 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:33.057505 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:33.058095 Saving settings file "H:\BOINC2\DaTa\slots\3\boinc_f97ecad8a13003af\boinc_f97ecad8a13003af.vbox" with version "1.16-windows" 00:00:33.198150 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:33.198341 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:33.206401 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:33.908667 Saving settings file "H:\BOINC2\DaTa\slots\3\boinc_f97ecad8a13003af\boinc_f97ecad8a13003af.vbox" with version "1.16-windows" 00:00:34.386835 Launched VM: 76931616 pid: 20216 (0x4ef8) frontend: headless name: boinc_f1c5c35ea7576e9b 00:00:35.192258 Saving settings file "H:\BOINC2\DaTa\slots\3\boinc_f97ecad8a13003af\boinc_f97ecad8a13003af.vbox" with version "1.16-windows" 00:00:35.879700 Saving settings file "H:\BOINC2\DaTa\slots\4\boinc_efadd3e199a90165\boinc_efadd3e199a90165.vbox" with version "1.16-windows" 00:00:36.140847 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:36.141013 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:36.152045 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:36.942791 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:37.427392 Launched VM: 76770560 pid: 21148 (0x529c) frontend: headless name: boinc_f97ecad8a13003af 00:00:37.648100 Saving settings file "H:\BOINC2\DaTa\slots\4\boinc_efadd3e199a90165\boinc_efadd3e199a90165.vbox" with version "1.16-windows" 00:00:38.352565 Saving settings file "C:\Users\bonsai\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:39.383701 Saving settings file "H:\BOINC2\DaTa\slots\8\boinc_f1c5c35ea7576e9b\boinc_f1c5c35ea7576e9b.vbox" with version "1.16-windows" 00:00:40.008514 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:40.482472 Saving settings file "H:\BOINC2\DaTa\slots\8\boinc_f1c5c35ea7576e9b\boinc_f1c5c35ea7576e9b.vbox" with version "1.16-windows" 00:00:41.113296 Saving settings file "C:\Users\bonsai\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:41.703193 Saving settings file "H:\BOINC2\DaTa\slots\3\boinc_f97ecad8a13003af\boinc_f97ecad8a13003af.vbox" with version "1.16-windows" 00:00:42.192084 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:42.549801 Saving settings file "H:\BOINC2\DaTa\slots\3\boinc_f97ecad8a13003af\boinc_f97ecad8a13003af.vbox" with version "1.16-windows" 00:00:42.941993 Saving settings file "C:\Users\bonsai\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:48.429259 main VirtualBox: object deletion starts 00:00:48.429812 main HostDnsMonitor: shutting down ... 00:00:48.429846 main HostDnsMonitor: shut down 00:00:48.435483 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:48.435679 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: Controllers: 8 Maximum SAS Port count: 255 Maximum Devices per SAS Port: 1 Maximum NVMe PIIX3 Controllers: 1 Maximum NVMe ICH9 Controllers: 8 Maximum NVMe Port count: 255 Maximum Devices per NVMe Port: 1 Maximum virtio-scsi PIIX3 Controllers: 1 Maximum virtio-scsi ICH9 Controllers: 8 Maximum virtio-scsi Port count: 256 Maximum Devices per virtio-scsi Port: 1 Maximum PIIX3 Floppy Controllers:1 Maximum ICH9 Floppy Controllers: 1 Maximum Floppy Port count: 1 Maximum Devices per Floppy Port: 2 Default machine folder: C:\Users\bonsai\VirtualBox VMs Raw-mode Supported: no Exclusive HW virtualization use: off Default hard disk format: VDI VRDE auth library: VBoxAuth Webservice auth. library: VBoxAuth Remote desktop ExtPack: Log history count: 3 Default frontend: Default audio driver: DirectSound Autostart database path: Default Guest Additions ISO: C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso Logging Level: all Proxy Mode: System Proxy URL: 2020-10-17 11:01:32 (14840): Command: VBoxManage -q list hostinfo Exit Code: 0 Output: Host Information: Host time: 2020-10-17T09:01:32.724000000Z Processor online count: 8 Processor count: 8 Processor online core count: 4 Processor core count: 4 Processor supports HW virtualization: no Processor supports PAE: yes Processor supports long mode: yes Processor supports nested paging: no Processor supports unrestricted guest: no Processor supports nested HW virtualization: no Processor#0 speed: unknown Processor#0 description: Intel(R) Xeon(R) CPU E3-1231 v3 @ 3.40GHz Processor#1 speed: unknown Processor#1 description: Intel(R) Xeon(R) CPU E3-1231 v3 @ 3.40GHz Processor#2 speed: unknown Processor#2 description: Intel(R) Xeon(R) CPU E3-1231 v3 @ 3.40GHz Processor#3 speed: unknown Processor#3 description: Intel(R) Xeon(R) CPU E3-1231 v3 @ 3.40GHz Processor#4 speed: unknown Processor#4 description: Intel(R) Xeon(R) CPU E3-1231 v3 @ 3.40GHz Processor#5 speed: unknown Processor#5 description: Intel(R) Xeon(R) CPU E3-1231 v3 @ 3.40GHz Processor#6 speed: unknown Processor#6 description: Intel(R) Xeon(R) CPU E3-1231 v3 @ 3.40GHz Processor#7 speed: unknown Processor#7 description: Intel(R) Xeon(R) CPU E3-1231 v3 @ 3.40GHz Memory size: 16325 MByte Memory available: 8673 MByte Operating system: Windows 10 Operating system version: 10.0.19041 2020-10-17 11:01:33 (14840): Command: VBoxManage -q showvminfo "boinc_f97ecad8a13003af" --machinereadable Exit Code: -2135228415 Output: VBoxManage.exe: error: Could not find a registered machine named 'boinc_f97ecad8a13003af' VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2715 of file VBoxManageInfo.cpp 2020-10-17 11:01:34 (14840): Command: VBoxManage -q showhdinfo "H:\BOINC2\DaTa\slots\3/vm_image.vdi" Exit Code: -2135228412 Output: VBoxManage.exe: error: Could not find file for the medium 'H:\BOINC2\DaTa\slots\3\vm_image.vdi' (VERR_FILE_NOT_FOUND) VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp 2020-10-17 11:01:34 (14840): Command: VBoxManage -q createvm --name "boinc_f97ecad8a13003af" --basefolder "H:\BOINC2\DaTa\slots\3" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_f97ecad8a13003af' is created and registered. UUID: e3f70811-b54a-4729-a334-e8676bbcd204 Settings file: 'H:\BOINC2\DaTa\slots\3\boinc_f97ecad8a13003af\boinc_f97ecad8a13003af.vbox' 2020-10-17 11:01:36 (14840): Command: VBoxManage -q modifyvm "boinc_f97ecad8a13003af" --description "07998281_46_0" Exit Code: 0 Output: 2020-10-17 11:01:37 (14840): Command: VBoxManage -q modifyvm "boinc_f97ecad8a13003af" --memory 3072 Exit Code: 0 Output: 2020-10-17 11:01:39 (14840): Command: VBoxManage -q modifyvm "boinc_f97ecad8a13003af" --cpus 1 Exit Code: 0 Output: 2020-10-17 11:01:40 (14840): Command: VBoxManage -q modifyvm "boinc_f97ecad8a13003af" --acpi on --ioapic on Exit Code: 0 Output: 2020-10-17 11:01:41 (14840): Command: VBoxManage -q modifyvm "boinc_f97ecad8a13003af" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2020-10-17 11:01:42 (14840): Command: VBoxManage -q modifyvm "boinc_f97ecad8a13003af" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2020-10-17 11:01:43 (14840): Command: VBoxManage -q modifyvm "boinc_f97ecad8a13003af" --cableconnected1 on Exit Code: 0 Output: 2020-10-17 11:01:44 (14840): Command: VBoxManage -q modifyvm "boinc_f97ecad8a13003af" --usb off Exit Code: 0 Output: 2020-10-17 11:01:45 (14840): Command: VBoxManage -q modifyvm "boinc_f97ecad8a13003af" --uart1 off --uart2 off Exit Code: 0 Output: 2020-10-17 11:01:46 (14840): Command: VBoxManage -q modifyvm "boinc_f97ecad8a13003af" --lpt1 off --lpt2 off Exit Code: 0 Output: 2020-10-17 11:01:46 (14840): Command: VBoxManage -q modifyvm "boinc_f97ecad8a13003af" --audio none Exit Code: 0 Output: 2020-10-17 11:01:47 (14840): Command: VBoxManage -q modifyvm "boinc_f97ecad8a13003af" --clipboard disabled Exit Code: 0 Output: 2020-10-17 11:01:48 (14840): Command: VBoxManage -q modifyvm "boinc_f97ecad8a13003af" --draganddrop disabled Exit Code: 0 Output: 2020-10-17 11:01:49 (14840): Command: VBoxManage -q storagectl "boinc_f97ecad8a13003af" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2020-10-17 11:01:50 (14840): Command: VBoxManage -q storageattach "boinc_f97ecad8a13003af" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "H:\BOINC2\DaTa\slots\3/vm_isocontext.iso" Exit Code: 0 Output: 2020-10-17 11:01:51 (14840): Command: VBoxManage -q storageattach "boinc_f97ecad8a13003af" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2020-10-17 11:01:52 (14840): Command: VBoxManage -q bandwidthctl "boinc_f97ecad8a13003af" add "boinc_f97ecad8a13003af_net" --type network --limit 1024G Exit Code: 0 Output: 2020-10-17 11:01:53 (14840): Command: VBoxManage -q sharedfolder add "boinc_f97ecad8a13003af" --name "shared" --hostpath "H:\BOINC2\DaTa\slots\3/shared" Exit Code: 0 Output: 2020-10-17 11:02:00 (14840): Command: VBoxManage -q startvm "boinc_f97ecad8a13003af" --type headless Exit Code: -2147467259 Output: Waiting for VM "boinc_f97ecad8a13003af" to power on... VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2020-10-17 11:02:00 (14840): Command: VBoxManage -q snapshot "boinc_f97ecad8a13003af" list Exit Code: -108 Output: This machine does not have any snapshots 2020-10-17 11:02:01 (14840): Command: VBoxManage -q bandwidthctl "boinc_f97ecad8a13003af" remove "boinc_f97ecad8a13003af_net" Exit Code: 0 Output: 2020-10-17 11:02:01 (14840): Command: VBoxManage -q unregistervm "boinc_f97ecad8a13003af" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 2020-10-17 11:02:02 (14840): Command: VBoxManage -q closemedium dvd "H:\BOINC2\DaTa\slots\3/vm_isocontext.iso" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 11:02:07 (14840): called boinc_finish(-2147467259) </stderr_txt> ]]>
©2025 COPYRIGHT 2017-2018 NCN