Task 10073953

Name 07992676_17_2
Workunit 7845758
Created 19 Oct 2020, 22:29:28 UTC
Sent 19 Oct 2020, 22:29:46 UTC
Report deadline 24 Oct 2020, 22:29:46 UTC
Received 20 Oct 2020, 14:48:08 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status 1 (0x00000001) Unknown error code
Computer ID 8974
Run time 18 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 3.98 GFLOPS
Application version boinc2docker v1.14 (vbox64_mt)
windows_x86_64
Peak working set size 9.25 MB
Peak swap size 2.09 MB
Peak disk usage 500.67 MB

Stderr output

<core_client_version>7.16.11</core_client_version>
<![CDATA[
<message>
Incorrect function.
 (0x1) - exit code 1 (0x1)</message>
<stderr_txt>
2020-10-20 03:52:07 (20096): Detected: vboxwrapper 26202
2020-10-20 03:52:07 (20096): Detected: BOINC client v7.16.11
2020-10-20 03:52:08 (20096): Detected: VirtualBox VboxManage Interface (Version: 6.1.12)
2020-10-20 03:52:09 (20096): Create VM. (boinc_c8733180333a8ce7, slot#8)
2020-10-20 03:52:09 (20096): Updating drive controller type and model for desired configuration.
2020-10-20 03:52:10 (20096): Setting Memory Size for VM. (3072MB)
2020-10-20 03:52:10 (20096): Setting CPU Count for VM. (1)
2020-10-20 03:52:10 (20096): Setting Chipset Options for VM.
2020-10-20 03:52:10 (20096): Setting Boot Options for VM.
2020-10-20 03:52:11 (20096): Setting Network Configuration for NAT.
2020-10-20 03:52:11 (20096): Enabling VM Network Access.
2020-10-20 03:52:11 (20096): Disabling USB Support for VM.
2020-10-20 03:52:12 (20096): Disabling COM Port Support for VM.
2020-10-20 03:52:12 (20096): Disabling LPT Port Support for VM.
2020-10-20 03:52:12 (20096): Disabling Audio Support for VM.
2020-10-20 03:52:12 (20096): Disabling Clipboard Support for VM.
2020-10-20 03:52:13 (20096): Disabling Drag and Drop Support for VM.
2020-10-20 03:52:13 (20096): Adding storage controller(s) to VM.
2020-10-20 03:52:13 (20096): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso)
2020-10-20 03:52:14 (20096): Adding VirtualBox Guest Additions to VM.
2020-10-20 03:52:14 (20096): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2020-10-20 03:52:14 (20096): Enabling shared directory for VM.
2020-10-20 03:52:15 (20096): Starting VM using VBoxManage interface. (boinc_c8733180333a8ce7, slot#8)
2020-10-20 03:52:16 (20096): Error in start VM for VM: 1
Command:
VBoxManage -q startvm "boinc_c8733180333a8ce7" --type headless
Output:
Waiting for VM "boinc_c8733180333a8ce7" to power on...
VBoxManage.exe: error: The virtual machine 'boinc_c8733180333a8ce7' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\8\boinc_c8733180333a8ce7\Logs\VBoxHardening.log'
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine

2020-10-20 03:52:16 (20096): VM failed to start.
2020-10-20 03:52:16 (20096): Could not start 
2020-10-20 03:52:16 (20096): ERROR: VM failed to start
2020-10-20 03:52:16 (20096): Powering off VM.
2020-10-20 03:52:16 (20096): Deregistering VM. (boinc_c8733180333a8ce7, slot#8)
2020-10-20 03:52:16 (20096): Removing network bandwidth throttle group from VM.
2020-10-20 03:52:16 (20096): Removing VM from VirtualBox.
2020-10-20 03:52:16 (20096): Removing virtual ISO 9660 disk from VirtualBox.

    Hypervisor System Log:

00:00:05.964313          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:05.968959          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:05.969207          Saving settings file "C:\Users\terry\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:05.973021          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:05.978598          Saving settings file "C:\Users\terry\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:05.987299          Saving settings file "C:\Users\terry\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:05.994989          Saving settings file "C:\Users\terry\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:05.995281          Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_c8733180333a8ce7\boinc_c8733180333a8ce7.vbox" with version "1.16-windows"
00:00:06.002428          Saving settings file "C:\ProgramData\BOINC\slots\10\boinc_5e18efc31ad2e0ae\boinc_5e18efc31ad2e0ae.vbox" with version "1.16-windows"
00:00:06.230053          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.235679          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.235898          Saving settings file "C:\Users\terry\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:06.242813          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.243334          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.244847          Saving settings file "C:\Users\terry\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:06.245278          Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_c8733180333a8ce7\boinc_c8733180333a8ce7.vbox" with version "1.16-windows"
00:00:06.252432          Saving settings file "C:\ProgramData\BOINC\slots\10\boinc_5e18efc31ad2e0ae\boinc_5e18efc31ad2e0ae.vbox" with version "1.16-windows"
00:00:06.505687          Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_c8733180333a8ce7\boinc_c8733180333a8ce7.vbox" with version "1.16-windows"
00:00:06.521882          Saving settings file "C:\ProgramData\BOINC\slots\10\boinc_5e18efc31ad2e0ae\boinc_5e18efc31ad2e0ae.vbox" with version "1.16-windows"
00:00:06.798658          Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_c8733180333a8ce7\boinc_c8733180333a8ce7.vbox" with version "1.16-windows"
00:00:06.837358          Saving settings file "C:\ProgramData\BOINC\slots\10\boinc_5e18efc31ad2e0ae\boinc_5e18efc31ad2e0ae.vbox" with version "1.16-windows"
00:00:07.071031          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.071228          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.081130          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:07.085076          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.085279          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.094406          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:07.354433          Launched VM: 73373760 pid: 12180 (0x2f94) frontend: headless name: boinc_c8733180333a8ce7
00:00:07.370459          Launched VM: 73365472 pid: 24360 (0x5f28) frontend: headless name: boinc_5e18efc31ad2e0ae
00:00:08.268320 Watcher  ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={The virtual machine 'boinc_c8733180333a8ce7' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\8\boinc_c8733180333a8ce7\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0
00:00:08.268896 Watcher  Reaper: Pid 12180 (2f94) exited normally: 1 (0x1)
00:00:08.269925 Watcher  ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={The virtual machine 'boinc_5e18efc31ad2e0ae' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\10\boinc_5e18efc31ad2e0ae\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0
00:00:08.270300 Watcher  Reaper: Pid 24360 (5f28) exited normally: 1 (0x1)
00:00:08.372629          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:08.372878          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:08.446602          Saving settings file "C:\ProgramData\BOINC\slots\10\boinc_5e18efc31ad2e0ae\boinc_5e18efc31ad2e0ae.vbox" with version "1.16-windows"
00:00:08.446742          Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_c8733180333a8ce7\boinc_c8733180333a8ce7.vbox" with version "1.16-windows"
00:00:08.710794          Saving settings file "C:\Users\terry\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:08.717487          Saving settings file "C:\Users\terry\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:14.007250 main     VirtualBox: object deletion starts
00:00:14.007771 main     HostDnsMonitor: shutting down ...
00:00:14.007830 main     HostDnsMonitor: shut down
00:00:14.009542 Watcher  ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0
00:00:14.009685 main     VirtualBox: object deleted

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

Remote desktop ExtPack:          
Log history count:               3
Default frontend:                
Default audio driver:            DirectSound
Autostart database path:         
Default Guest Additions ISO:     C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso
Logging Level:                   all
Proxy Mode:                      System
Proxy URL:                       

2020-10-20 03:52:09 (20096): 
Command: VBoxManage -q list hostinfo 
Exit Code: 0
Output:
Host Information:

Host time: 2020-10-20T02:52:08.819000000Z
Processor online count: 16
Processor count: 16
Processor online core count: 8
Processor core count: 8
Processor supports HW virtualization: no
Processor supports PAE: yes
Processor supports long mode: yes
Processor supports nested paging: no
Processor supports unrestricted guest: no
Processor supports nested HW virtualization: no
Processor#0 speed: unknown
Processor#0 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#1 speed: unknown
Processor#1 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#2 speed: unknown
Processor#2 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#3 speed: unknown
Processor#3 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#4 speed: unknown
Processor#4 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#5 speed: unknown
Processor#5 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#6 speed: unknown
Processor#6 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#7 speed: unknown
Processor#7 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#8 speed: unknown
Processor#8 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#9 speed: unknown
Processor#9 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#10 speed: unknown
Processor#10 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#11 speed: unknown
Processor#11 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#12 speed: unknown
Processor#12 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#13 speed: unknown
Processor#13 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#14 speed: unknown
Processor#14 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#15 speed: unknown
Processor#15 description: AMD Ryzen 7 1800X Eight-Core Processor
Memory size: 16313 MByte
Memory available: 6271 MByte
Operating system: Windows 10
Operating system version: 10.0.19041

2020-10-20 03:52:09 (20096): 
Command: VBoxManage -q showvminfo "boinc_c8733180333a8ce7" --machinereadable 
Exit Code: -2135228415
Output:
VBoxManage.exe: error: Could not find a registered machine named 'boinc_c8733180333a8ce7'
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown
VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2715 of file VBoxManageInfo.cpp

2020-10-20 03:52:09 (20096): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\8/vm_image.vdi" 
Exit Code: -2135228412
Output:
VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\8\vm_image.vdi' (VERR_FILE_NOT_FOUND)
VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp

2020-10-20 03:52:09 (20096): 
Command: VBoxManage -q createvm --name "boinc_c8733180333a8ce7" --basefolder "C:\ProgramData\BOINC\slots\8" --ostype "Linux26_64" --register
Exit Code: 0
Output:
Virtual machine 'boinc_c8733180333a8ce7' is created and registered.
UUID: 6172bd69-4b76-4406-b037-843e23d82b61
Settings file: 'C:\ProgramData\BOINC\slots\8\boinc_c8733180333a8ce7\boinc_c8733180333a8ce7.vbox'

2020-10-20 03:52:10 (20096): 
Command: VBoxManage -q modifyvm "boinc_c8733180333a8ce7" --description "07992676_17_2" 
Exit Code: 0
Output:

2020-10-20 03:52:10 (20096): 
Command: VBoxManage -q modifyvm "boinc_c8733180333a8ce7" --memory 3072 
Exit Code: 0
Output:

2020-10-20 03:52:10 (20096): 
Command: VBoxManage -q modifyvm "boinc_c8733180333a8ce7" --cpus 1 
Exit Code: 0
Output:

2020-10-20 03:52:10 (20096): 
Command: VBoxManage -q modifyvm "boinc_c8733180333a8ce7" --acpi on --ioapic on 
Exit Code: 0
Output:

2020-10-20 03:52:11 (20096): 
Command: VBoxManage -q modifyvm "boinc_c8733180333a8ce7" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2020-10-20 03:52:11 (20096): 
Command: VBoxManage -q modifyvm "boinc_c8733180333a8ce7" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2020-10-20 03:52:11 (20096): 
Command: VBoxManage -q modifyvm "boinc_c8733180333a8ce7" --cableconnected1 on 
Exit Code: 0
Output:

2020-10-20 03:52:12 (20096): 
Command: VBoxManage -q modifyvm "boinc_c8733180333a8ce7" --usb off 
Exit Code: 0
Output:

2020-10-20 03:52:12 (20096): 
Command: VBoxManage -q modifyvm "boinc_c8733180333a8ce7" --uart1 off --uart2 off 
Exit Code: 0
Output:

2020-10-20 03:52:12 (20096): 
Command: VBoxManage -q modifyvm "boinc_c8733180333a8ce7" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2020-10-20 03:52:12 (20096): 
Command: VBoxManage -q modifyvm "boinc_c8733180333a8ce7" --audio none 
Exit Code: 0
Output:

2020-10-20 03:52:13 (20096): 
Command: VBoxManage -q modifyvm "boinc_c8733180333a8ce7" --clipboard disabled 
Exit Code: 0
Output:

2020-10-20 03:52:13 (20096): 
Command: VBoxManage -q modifyvm "boinc_c8733180333a8ce7" --draganddrop disabled 
Exit Code: 0
Output:

2020-10-20 03:52:13 (20096): 
Command: VBoxManage -q storagectl "boinc_c8733180333a8ce7" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2020-10-20 03:52:14 (20096): 
Command: VBoxManage -q storageattach "boinc_c8733180333a8ce7" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\ProgramData\BOINC\slots\8/vm_isocontext.iso" 
Exit Code: 0
Output:

2020-10-20 03:52:14 (20096): 
Command: VBoxManage -q storageattach "boinc_c8733180333a8ce7" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2020-10-20 03:52:14 (20096): 
Command: VBoxManage -q bandwidthctl "boinc_c8733180333a8ce7" add "boinc_c8733180333a8ce7_net" --type network --limit 1024G 
Exit Code: 0
Output:

2020-10-20 03:52:14 (20096): 
Command: VBoxManage -q sharedfolder add "boinc_c8733180333a8ce7" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\8/shared"
Exit Code: 0
Output:

2020-10-20 03:52:16 (20096): 
Command: VBoxManage -q startvm "boinc_c8733180333a8ce7" --type headless
Exit Code: 1
Output:
Waiting for VM "boinc_c8733180333a8ce7" to power on...
VBoxManage.exe: error: The virtual machine 'boinc_c8733180333a8ce7' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\8\boinc_c8733180333a8ce7\Logs\VBoxHardening.log'
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine

2020-10-20 03:52:16 (20096): 
Command: VBoxManage -q snapshot "boinc_c8733180333a8ce7" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2020-10-20 03:52:16 (20096): 
Command: VBoxManage -q bandwidthctl "boinc_c8733180333a8ce7" remove "boinc_c8733180333a8ce7_net" 
Exit Code: 0
Output:

2020-10-20 03:52:16 (20096): 
Command: VBoxManage -q unregistervm "boinc_c8733180333a8ce7" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

2020-10-20 03:52:17 (20096): 
Command: VBoxManage -q closemedium dvd "C:\ProgramData\BOINC\slots\8/vm_isocontext.iso" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

03:52:23 (20096): called boinc_finish(1)

</stderr_txt>
]]>


©2025 COPYRIGHT 2017-2018 NCN