Task 10084850

Name 07994824_37_2
Workunit 7859264
Created 22 Oct 2020, 18:13:55 UTC
Sent 22 Oct 2020, 18:16:25 UTC
Report deadline 27 Oct 2020, 18:16:25 UTC
Received 23 Oct 2020, 20:56:59 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status 1 (0x00000001) Unknown error code
Computer ID 6720
Run time 11 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 3.52 GFLOPS
Application version boinc2docker v1.14 (vbox64_mt)
windows_x86_64
Peak working set size 6.41 MB
Peak swap size 1.90 MB
Peak disk usage 226.97 MB

Stderr output

<core_client_version>7.16.7</core_client_version>
<![CDATA[
<message>
Incorrect function.
 (0x1) - exit code 1 (0x1)</message>
<stderr_txt>
2020-10-22 12:17:49 (17840): Detected: vboxwrapper 26202
2020-10-22 12:17:49 (17840): Detected: BOINC client v7.16.7
2020-10-22 12:17:49 (17840): Detected: VirtualBox VboxManage Interface (Version: 6.0.14)
2020-10-22 12:17:50 (17840): Create VM. (boinc_0f48c5fa372f211a, slot#0)
2020-10-22 12:17:50 (17840): Updating drive controller type and model for desired configuration.
2020-10-22 12:17:51 (17840): Setting Memory Size for VM. (3072MB)
2020-10-22 12:17:51 (17840): Setting CPU Count for VM. (1)
2020-10-22 12:17:51 (17840): Setting Chipset Options for VM.
2020-10-22 12:17:52 (17840): Setting Boot Options for VM.
2020-10-22 12:17:52 (17840): Setting Network Configuration for NAT.
2020-10-22 12:17:52 (17840): Enabling VM Network Access.
2020-10-22 12:17:52 (17840): Disabling USB Support for VM.
2020-10-22 12:17:53 (17840): Disabling COM Port Support for VM.
2020-10-22 12:17:53 (17840): Disabling LPT Port Support for VM.
2020-10-22 12:17:53 (17840): Disabling Audio Support for VM.
2020-10-22 12:17:53 (17840): Disabling Clipboard Support for VM.
2020-10-22 12:17:54 (17840): Disabling Drag and Drop Support for VM.
2020-10-22 12:17:54 (17840): Adding storage controller(s) to VM.
2020-10-22 12:17:54 (17840): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso)
2020-10-22 12:17:54 (17840): Adding VirtualBox Guest Additions to VM.
2020-10-22 12:17:55 (17840): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2020-10-22 12:17:55 (17840): Enabling shared directory for VM.
2020-10-22 12:17:55 (17840): Starting VM using VBoxManage interface. (boinc_0f48c5fa372f211a, slot#0)
2020-10-22 12:17:56 (17840): Error in start VM for VM: 1
Command:
VBoxManage -q startvm "boinc_0f48c5fa372f211a" --type headless
Output:
Waiting for VM "boinc_0f48c5fa372f211a" to power on...
VBoxManage.exe: error: The virtual machine 'boinc_0f48c5fa372f211a' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\0\boinc_0f48c5fa372f211a\Logs\VBoxHardening.log'
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine

2020-10-22 12:17:56 (17840): VM failed to start.
2020-10-22 12:17:56 (17840): Could not start 
2020-10-22 12:17:56 (17840): ERROR: VM failed to start
2020-10-22 12:17:56 (17840): Powering off VM.
2020-10-22 12:17:56 (17840): Deregistering VM. (boinc_0f48c5fa372f211a, slot#0)
2020-10-22 12:17:57 (17840): Removing network bandwidth throttle group from VM.
2020-10-22 12:17:57 (17840): Removing VM from VirtualBox.
2020-10-22 12:17:57 (17840): Removing virtual ISO 9660 disk from VirtualBox.

    Hypervisor System Log:

00:01:33.640925          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_168364923904a779\boinc_168364923904a779.vbox" with version "1.16-windows"
00:01:33.659989          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:01:33.884499          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:01:33.887224          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_168364923904a779\boinc_168364923904a779.vbox" with version "1.16-windows"
00:01:34.149373          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:01:34.152343          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_168364923904a779\boinc_168364923904a779.vbox" with version "1.16-windows"
00:01:34.413668 Watcher  ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={MachineWrap} aText={The virtual machine 'boinc_0f48c5fa372f211a' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\0\boinc_0f48c5fa372f211a\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0
00:01:34.420230          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:01:34.428891          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:01:34.429083          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:01:34.435212          WARNING [COM]: aRC=E_FAIL (0x80004005) aIID={dbe11e5f-7f10-46e7-94c4-1e95bf4b6627} aComponent={HostWrap} aText={Could not load the Host USB Proxy Service (VERR_FILE_NOT_FOUND). The service might not be installed on the host computer}, preserve=true  aResultDetail=0
00:01:34.435328          WARNING [COM]: aRC=E_FAIL (0x80004005) aIID={dbe11e5f-7f10-46e7-94c4-1e95bf4b6627} aComponent={HostWrap} aText={Could not load the Host USB Proxy Service (VERR_FILE_NOT_FOUND). The service might not be installed on the host computer}, preserve=true  aResultDetail=0
00:01:34.437990          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:01:34.510977          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:01:34.513972          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:01:34.539396 Watcher  ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={MachineWrap} aText={The virtual machine 'boinc_14c24c101df18425' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\1\boinc_14c24c101df18425\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0
00:01:34.587930          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:01:34.591553          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_0f48c5fa372f211a\boinc_0f48c5fa372f211a.vbox" with version "1.16-windows"
00:01:34.629837          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:01:34.631991          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:01:34.671425          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:01:34.695329          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:01:34.697778          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_14c24c101df18425\boinc_14c24c101df18425.vbox" with version "1.16-windows"
00:01:34.843436          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:01:34.843926          Saving settings file "C:\Users\John\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:01:34.960966          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:01:34.961350          Saving settings file "C:\Users\John\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:01:35.098562          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:01:35.216537          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:01:35.526326 Watcher  ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={MachineWrap} aText={The virtual machine 'boinc_168364923904a779' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\2\boinc_168364923904a779\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0
00:01:35.606017          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:01:35.608327          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:01:35.673464          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:01:35.675784          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_168364923904a779\boinc_168364923904a779.vbox" with version "1.16-windows"
00:01:35.932304          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0
00:01:35.932728          Saving settings file "C:\Users\John\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:01:36.202620          ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={5047460a-265d-4538-b23e-ddba5fb84976} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

3 SCSI Controllers:  1
Maximum ICH9 SCSI Controllers:   8
Maximum SCSI Port count:         16
Maximum Devices per SCSI Port:   1
Maximum SAS PIIX3 Controllers:   1
Maximum SAS ICH9 Controllers:    8
Maximum SAS Port count:          255
Maximum Devices per SAS Port:    1
Maximum NVMe PIIX3 Controllers:  1
Maximum NVMe ICH9 Controllers:   8
Maximum NVMe Port count:         255
Maximum Devices per NVMe Port:   1
Maximum PIIX3 Floppy Controllers:1
Maximum ICH9 Floppy Controllers: 1
Maximum Floppy Port count:       1
Maximum Devices per Floppy Port: 2
Default machine folder:          C:\Users\John\VirtualBox VMs
Raw-mode Supported:              yes
Exclusive HW virtualization use: off
Default hard disk format:        VDI
VRDE auth library:               VBoxAuth
Webservice auth. library:        VBoxAuth
Remote desktop ExtPack:          
Log history count:               3
Default frontend:                
Default audio driver:            DirectSound
Autostart database path:         
Default Guest Additions ISO:     C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso
Logging Level:                   all
Proxy Mode:                      System
Proxy URL:                       

2020-10-22 12:17:50 (17840): 
Command: VBoxManage -q list hostinfo 
Exit Code: 0
Output:
Host Information:

Host time: 2020-10-22T18:17:49.993000000Z
Processor online count: 8
Processor count: 8
Processor online core count: 4
Processor core count: 4
Processor supports HW virtualization: yes
Processor supports PAE: yes
Processor supports long mode: yes
Processor supports nested paging: no
Processor#0 speed: unknown
Processor#0 description: Intel(R) Core(TM) i7-2600K CPU @ 3.40GHz
Processor#1 speed: unknown
Processor#1 description: Intel(R) Core(TM) i7-2600K CPU @ 3.40GHz
Processor#2 speed: unknown
Processor#2 description: Intel(R) Core(TM) i7-2600K CPU @ 3.40GHz
Processor#3 speed: unknown
Processor#3 description: Intel(R) Core(TM) i7-2600K CPU @ 3.40GHz
Processor#4 speed: unknown
Processor#4 description: Intel(R) Core(TM) i7-2600K CPU @ 3.40GHz
Processor#5 speed: unknown
Processor#5 description: Intel(R) Core(TM) i7-2600K CPU @ 3.40GHz
Processor#6 speed: unknown
Processor#6 description: Intel(R) Core(TM) i7-2600K CPU @ 3.40GHz
Processor#7 speed: unknown
Processor#7 description: Intel(R) Core(TM) i7-2600K CPU @ 3.40GHz
Memory size: 32680 MByte
Memory available: 22829 MByte
Operating system: Windows 10
Operating system version: 10.0.18363

2020-10-22 12:17:50 (17840): 
Command: VBoxManage -q showvminfo "boinc_0f48c5fa372f211a" --machinereadable 
Exit Code: -2135228415
Output:
VBoxManage.exe: error: Could not find a registered machine named 'boinc_0f48c5fa372f211a'
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown
VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2621 of file VBoxManageInfo.cpp

2020-10-22 12:17:50 (17840): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\0/vm_image.vdi" 
Exit Code: -2135228412
Output:
VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\0\vm_image.vdi' (VERR_FILE_NOT_FOUND)
VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp

2020-10-22 12:17:50 (17840): 
Command: VBoxManage -q createvm --name "boinc_0f48c5fa372f211a" --basefolder "C:\ProgramData\BOINC\slots\0" --ostype "Linux26_64" --register
Exit Code: 0
Output:
Virtual machine 'boinc_0f48c5fa372f211a' is created and registered.
UUID: a94f6ea2-2c16-47fa-8340-a088b878cf4c
Settings file: 'C:\ProgramData\BOINC\slots\0\boinc_0f48c5fa372f211a\boinc_0f48c5fa372f211a.vbox'

2020-10-22 12:17:51 (17840): 
Command: VBoxManage -q modifyvm "boinc_0f48c5fa372f211a" --description "07994824_37_2" 
Exit Code: 0
Output:

2020-10-22 12:17:51 (17840): 
Command: VBoxManage -q modifyvm "boinc_0f48c5fa372f211a" --memory 3072 
Exit Code: 0
Output:

2020-10-22 12:17:51 (17840): 
Command: VBoxManage -q modifyvm "boinc_0f48c5fa372f211a" --cpus 1 
Exit Code: 0
Output:

2020-10-22 12:17:52 (17840): 
Command: VBoxManage -q modifyvm "boinc_0f48c5fa372f211a" --acpi on --ioapic on 
Exit Code: 0
Output:

2020-10-22 12:17:52 (17840): 
Command: VBoxManage -q modifyvm "boinc_0f48c5fa372f211a" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2020-10-22 12:17:52 (17840): 
Command: VBoxManage -q modifyvm "boinc_0f48c5fa372f211a" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2020-10-22 12:17:52 (17840): 
Command: VBoxManage -q modifyvm "boinc_0f48c5fa372f211a" --cableconnected1 on 
Exit Code: 0
Output:

2020-10-22 12:17:53 (17840): 
Command: VBoxManage -q modifyvm "boinc_0f48c5fa372f211a" --usb off 
Exit Code: 0
Output:

2020-10-22 12:17:53 (17840): 
Command: VBoxManage -q modifyvm "boinc_0f48c5fa372f211a" --uart1 off --uart2 off 
Exit Code: 0
Output:

2020-10-22 12:17:53 (17840): 
Command: VBoxManage -q modifyvm "boinc_0f48c5fa372f211a" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2020-10-22 12:17:53 (17840): 
Command: VBoxManage -q modifyvm "boinc_0f48c5fa372f211a" --audio none 
Exit Code: 0
Output:

2020-10-22 12:17:54 (17840): 
Command: VBoxManage -q modifyvm "boinc_0f48c5fa372f211a" --clipboard disabled 
Exit Code: 0
Output:

2020-10-22 12:17:54 (17840): 
Command: VBoxManage -q modifyvm "boinc_0f48c5fa372f211a" --draganddrop disabled 
Exit Code: 0
Output:

2020-10-22 12:17:54 (17840): 
Command: VBoxManage -q storagectl "boinc_0f48c5fa372f211a" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2020-10-22 12:17:54 (17840): 
Command: VBoxManage -q storageattach "boinc_0f48c5fa372f211a" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\ProgramData\BOINC\slots\0/vm_isocontext.iso" 
Exit Code: 0
Output:

2020-10-22 12:17:55 (17840): 
Command: VBoxManage -q storageattach "boinc_0f48c5fa372f211a" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2020-10-22 12:17:55 (17840): 
Command: VBoxManage -q bandwidthctl "boinc_0f48c5fa372f211a" add "boinc_0f48c5fa372f211a_net" --type network --limit 1024G 
Exit Code: 0
Output:

2020-10-22 12:17:55 (17840): 
Command: VBoxManage -q sharedfolder add "boinc_0f48c5fa372f211a" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\0/shared"
Exit Code: 0
Output:

2020-10-22 12:17:56 (17840): 
Command: VBoxManage -q startvm "boinc_0f48c5fa372f211a" --type headless
Exit Code: 1
Output:
Waiting for VM "boinc_0f48c5fa372f211a" to power on...
VBoxManage.exe: error: The virtual machine 'boinc_0f48c5fa372f211a' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\0\boinc_0f48c5fa372f211a\Logs\VBoxHardening.log'
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine

2020-10-22 12:17:57 (17840): 
Command: VBoxManage -q snapshot "boinc_0f48c5fa372f211a" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2020-10-22 12:17:57 (17840): 
Command: VBoxManage -q bandwidthctl "boinc_0f48c5fa372f211a" remove "boinc_0f48c5fa372f211a_net" 
Exit Code: 0
Output:

2020-10-22 12:17:57 (17840): 
Command: VBoxManage -q unregistervm "boinc_0f48c5fa372f211a" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

2020-10-22 12:17:57 (17840): 
Command: VBoxManage -q closemedium dvd "C:\ProgramData\BOINC\slots\0/vm_isocontext.iso" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

12:18:08 (17840): called boinc_finish(1)

</stderr_txt>
]]>


©2024 COPYRIGHT 2017-2018 NCN