Name | 08281954_54_0 |
Workunit | 7961329 |
Created | 15 Apr 2021, 2:33:28 UTC |
Sent | 15 Apr 2021, 4:06:21 UTC |
Report deadline | 20 Apr 2021, 4:06:21 UTC |
Received | 15 Apr 2021, 16:28:46 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | -2147467259 (0x80004005) Unknown error code |
Computer ID | 10951 |
Run time | 46 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 2.91 GFLOPS |
Application version | boinc2docker v1.14 (vbox64_mt) windows_x86_64 |
Peak working set size | 10.53 MB |
Peak swap size | 6.22 MB |
Peak disk usage | 500.10 MB |
<core_client_version>7.16.11</core_client_version> <![CDATA[ <message> Unspecified error (0x80004005) - exit code 2147500037 (0x80004005)</message> <stderr_txt> 2021-04-14 21:35:42 (15148): Detected: vboxwrapper 26202 2021-04-14 21:35:42 (15148): Detected: BOINC client v7.16.11 2021-04-14 21:35:43 (15148): Detected: VirtualBox VboxManage Interface (Version: 6.1.12) 2021-04-14 21:35:45 (15148): Create VM. (boinc_5072841977fb3bee, slot#3) 2021-04-14 21:35:45 (15148): Updating drive controller type and model for desired configuration. 2021-04-14 21:35:51 (15148): Setting Memory Size for VM. (3072MB) 2021-04-14 21:35:56 (15148): Setting CPU Count for VM. (1) 2021-04-14 21:35:56 (15148): Setting Chipset Options for VM. 2021-04-14 21:35:56 (15148): Setting Boot Options for VM. 2021-04-14 21:35:58 (15148): Setting Network Configuration for NAT. 2021-04-14 21:36:03 (15148): Enabling VM Network Access. 2021-04-14 21:36:03 (15148): Disabling USB Support for VM. 2021-04-14 21:36:06 (15148): Disabling COM Port Support for VM. 2021-04-14 21:36:09 (15148): Disabling LPT Port Support for VM. 2021-04-14 21:36:10 (15148): Disabling Audio Support for VM. 2021-04-14 21:36:11 (15148): Disabling Clipboard Support for VM. 2021-04-14 21:36:11 (15148): Disabling Drag and Drop Support for VM. 2021-04-14 21:36:11 (15148): Adding storage controller(s) to VM. 2021-04-14 21:36:12 (15148): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso) 2021-04-14 21:36:12 (15148): Adding VirtualBox Guest Additions to VM. 2021-04-14 21:36:12 (15148): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2021-04-14 21:36:13 (15148): Enabling shared directory for VM. 2021-04-14 21:36:13 (15148): Starting VM using VBoxManage interface. (boinc_5072841977fb3bee, slot#3) 2021-04-14 21:36:17 (15148): Error in start VM for VM: -2147467259 Command: VBoxManage -q startvm "boinc_5072841977fb3bee" --type headless Output: Waiting for VM "boinc_5072841977fb3bee" to power on... VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2021-04-14 21:36:17 (15148): VM failed to start. 2021-04-14 21:36:17 (15148): Could not start 2021-04-14 21:36:17 (15148): ERROR: VM failed to start 2021-04-14 21:36:17 (15148): Powering off VM. 2021-04-14 21:36:17 (15148): Deregistering VM. (boinc_5072841977fb3bee, slot#3) 2021-04-14 21:36:17 (15148): Removing network bandwidth throttle group from VM. 2021-04-14 21:36:17 (15148): Removing VM from VirtualBox. 2021-04-14 21:36:19 (15148): Removing virtual ISO 9660 disk from VirtualBox. Hypervisor System Log: 00:00:34.817315 Saving settings file "C:\Users\Top Student\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:34.875357 Saving settings file "C:\Users\Top Student\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:34.940442 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_4e0d24f45a6a6ce9\boinc_4e0d24f45a6a6ce9.vbox" with version "1.16-windows" 00:00:35.194391 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_5072841977fb3bee\boinc_5072841977fb3bee.vbox" with version "1.16-windows" 00:00:35.212077 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:35.214375 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:35.220717 Saving settings file "C:\Users\Top Student\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:35.268130 Saving settings file "C:\Users\Top Student\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:35.408073 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_4e0d24f45a6a6ce9\boinc_4e0d24f45a6a6ce9.vbox" with version "1.16-windows" 00:00:37.393834 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_5072841977fb3bee\boinc_5072841977fb3bee.vbox" with version "1.16-windows" 00:00:39.133937 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_4e0d24f45a6a6ce9\boinc_4e0d24f45a6a6ce9.vbox" with version "1.16-windows" 00:00:39.693632 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_4e0d24f45a6a6ce9\boinc_4e0d24f45a6a6ce9.vbox" with version "1.16-windows" 00:00:41.277756 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_5072841977fb3bee\boinc_5072841977fb3bee.vbox" with version "1.16-windows" 00:00:41.328228 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:41.328442 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:41.341312 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:41.890508 Launched VM: 65586112 pid: 12324 (0x3024) frontend: headless name: boinc_4e0d24f45a6a6ce9 00:00:41.907005 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_5072841977fb3bee\boinc_5072841977fb3bee.vbox" with version "1.16-windows" 00:00:42.422591 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_5072841977fb3bee\boinc_5072841977fb3bee.vbox" with version "1.16-windows" 00:00:42.973529 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_5072841977fb3bee\boinc_5072841977fb3bee.vbox" with version "1.16-windows" 00:00:43.264055 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_5072841977fb3bee\boinc_5072841977fb3bee.vbox" with version "1.16-windows" 00:00:43.533137 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:43.535379 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:43.535606 Saving settings file "C:\Users\Top Student\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:43.665384 Saving settings file "C:\Users\Top Student\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:43.708187 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_5072841977fb3bee\boinc_5072841977fb3bee.vbox" with version "1.16-windows" 00:00:44.066148 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:44.066820 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:44.067696 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_5072841977fb3bee\boinc_5072841977fb3bee.vbox" with version "1.16-windows" 00:00:44.324732 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_5072841977fb3bee\boinc_5072841977fb3bee.vbox" with version "1.16-windows" 00:00:44.588498 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_5072841977fb3bee\boinc_5072841977fb3bee.vbox" with version "1.16-windows" 00:00:44.857312 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:44.857530 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:44.869303 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:45.101234 Launched VM: 65210432 pid: 8524 (0x214c) frontend: headless name: boinc_5072841977fb3bee 00:00:45.543446 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_4e0d24f45a6a6ce9\boinc_4e0d24f45a6a6ce9.vbox" with version "1.16-windows" 00:00:46.613786 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:46.724582 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_4e0d24f45a6a6ce9\boinc_4e0d24f45a6a6ce9.vbox" with version "1.16-windows" 00:00:47.249984 Saving settings file "C:\Users\Top Student\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:48.562016 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_5072841977fb3bee\boinc_5072841977fb3bee.vbox" with version "1.16-windows" 00:00:48.834128 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:49.186843 Saving settings file "C:\Users\Top Student\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:56.091153 main VirtualBox: object deletion starts 00:00:56.094724 main HostDnsMonitor: shutting down ... 00:00:56.094904 main HostDnsMonitor: shut down 00:00:56.102896 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:56.103637 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: Maximum Devices per SATA Port: 1 Maximum PIIX3 SCSI Controllers: 1 Maximum ICH9 SCSI Controllers: 8 Maximum SCSI Port count: 16 Maximum Devices per SCSI Port: 1 Maximum SAS PIIX3 Controllers: 1 Maximum SAS ICH9 Controllers: 8 Maximum SAS Port count: 255 Maximum Devices per SAS Port: 1 Maximum NVMe PIIX3 Controllers: 1 Maximum NVMe ICH9 Controllers: 8 Maximum NVMe Port count: 255 Maximum Devices per NVMe Port: 1 Maximum virtio-scsi PIIX3 Controllers: 1 Maximum virtio-scsi ICH9 Controllers: 8 Maximum virtio-scsi Port count: 256 Maximum Devices per virtio-scsi Port: 1 Maximum PIIX3 Floppy Controllers:1 Maximum ICH9 Floppy Controllers: 1 Maximum Floppy Port count: 1 Maximum Devices per Floppy Port: 2 Default machine folder: C:\Users\Top Student\VirtualBox VMs Raw-mode Supported: no Exclusive HW virtualization use: off Default hard disk format: VDI VRDE auth library: VBoxAuth Webservice auth. library: VBoxAuth Remote desktop ExtPack: Log history count: 3 Default frontend: Default audio driver: DirectSound Autostart database path: Default Guest Additions ISO: C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso Logging Level: all Proxy Mode: System Proxy URL: 2021-04-14 21:35:43 (15148): Command: VBoxManage -q list hostinfo Exit Code: 0 Output: Host Information: Host time: 2021-04-15T04:35:43.315000000Z Processor online count: 4 Processor count: 4 Processor online core count: 4 Processor core count: 4 Processor supports HW virtualization: no Processor supports PAE: yes Processor supports long mode: yes Processor supports nested paging: no Processor supports unrestricted guest: no Processor supports nested HW virtualization: no Processor#0 speed: unknown Processor#0 description: Intel(R) Pentium(R) Silver N5000 CPU @ 1.10GHz Processor#1 speed: unknown Processor#1 description: Intel(R) Pentium(R) Silver N5000 CPU @ 1.10GHz Processor#2 speed: unknown Processor#2 description: Intel(R) Pentium(R) Silver N5000 CPU @ 1.10GHz Processor#3 speed: unknown Processor#3 description: Intel(R) Pentium(R) Silver N5000 CPU @ 1.10GHz Memory size: 8023 MByte Memory available: 2803 MByte Operating system: Windows 10 Operating system version: 10.0.19041 2021-04-14 21:35:45 (15148): Command: VBoxManage -q showvminfo "boinc_5072841977fb3bee" --machinereadable Exit Code: -2135228415 Output: VBoxManage.exe: error: Could not find a registered machine named 'boinc_5072841977fb3bee' VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2715 of file VBoxManageInfo.cpp 2021-04-14 21:35:45 (15148): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\3/vm_image.vdi" Exit Code: -2135228412 Output: VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\3\vm_image.vdi' (VERR_FILE_NOT_FOUND) VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp 2021-04-14 21:35:50 (15148): Command: VBoxManage -q createvm --name "boinc_5072841977fb3bee" --basefolder "C:\ProgramData\BOINC\slots\3" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_5072841977fb3bee' is created and registered. UUID: 0cc41952-e88e-4af5-b7bc-59a13d278bc2 Settings file: 'C:\ProgramData\BOINC\slots\3\boinc_5072841977fb3bee\boinc_5072841977fb3bee.vbox' 2021-04-14 21:35:51 (15148): Command: VBoxManage -q modifyvm "boinc_5072841977fb3bee" --description "08281954_54_0" Exit Code: 0 Output: 2021-04-14 21:35:56 (15148): Command: VBoxManage -q modifyvm "boinc_5072841977fb3bee" --memory 3072 Exit Code: 0 Output: 2021-04-14 21:35:56 (15148): Command: VBoxManage -q modifyvm "boinc_5072841977fb3bee" --cpus 1 Exit Code: 0 Output: 2021-04-14 21:35:56 (15148): Command: VBoxManage -q modifyvm "boinc_5072841977fb3bee" --acpi on --ioapic on Exit Code: 0 Output: 2021-04-14 21:35:58 (15148): Command: VBoxManage -q modifyvm "boinc_5072841977fb3bee" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2021-04-14 21:36:03 (15148): Command: VBoxManage -q modifyvm "boinc_5072841977fb3bee" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2021-04-14 21:36:03 (15148): Command: VBoxManage -q modifyvm "boinc_5072841977fb3bee" --cableconnected1 on Exit Code: 0 Output: 2021-04-14 21:36:06 (15148): Command: VBoxManage -q modifyvm "boinc_5072841977fb3bee" --usb off Exit Code: 0 Output: 2021-04-14 21:36:08 (15148): Command: VBoxManage -q modifyvm "boinc_5072841977fb3bee" --uart1 off --uart2 off Exit Code: 0 Output: 2021-04-14 21:36:10 (15148): Command: VBoxManage -q modifyvm "boinc_5072841977fb3bee" --lpt1 off --lpt2 off Exit Code: 0 Output: 2021-04-14 21:36:11 (15148): Command: VBoxManage -q modifyvm "boinc_5072841977fb3bee" --audio none Exit Code: 0 Output: 2021-04-14 21:36:11 (15148): Command: VBoxManage -q modifyvm "boinc_5072841977fb3bee" --clipboard disabled Exit Code: 0 Output: 2021-04-14 21:36:11 (15148): Command: VBoxManage -q modifyvm "boinc_5072841977fb3bee" --draganddrop disabled Exit Code: 0 Output: 2021-04-14 21:36:12 (15148): Command: VBoxManage -q storagectl "boinc_5072841977fb3bee" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2021-04-14 21:36:12 (15148): Command: VBoxManage -q storageattach "boinc_5072841977fb3bee" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\ProgramData\BOINC\slots\3/vm_isocontext.iso" Exit Code: 0 Output: 2021-04-14 21:36:12 (15148): Command: VBoxManage -q storageattach "boinc_5072841977fb3bee" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2021-04-14 21:36:13 (15148): Command: VBoxManage -q bandwidthctl "boinc_5072841977fb3bee" add "boinc_5072841977fb3bee_net" --type network --limit 1024G Exit Code: 0 Output: 2021-04-14 21:36:13 (15148): Command: VBoxManage -q sharedfolder add "boinc_5072841977fb3bee" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\3/shared" Exit Code: 0 Output: 2021-04-14 21:36:17 (15148): Command: VBoxManage -q startvm "boinc_5072841977fb3bee" --type headless Exit Code: -2147467259 Output: Waiting for VM "boinc_5072841977fb3bee" to power on... VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2021-04-14 21:36:17 (15148): Command: VBoxManage -q snapshot "boinc_5072841977fb3bee" list Exit Code: -108 Output: This machine does not have any snapshots 2021-04-14 21:36:17 (15148): Command: VBoxManage -q bandwidthctl "boinc_5072841977fb3bee" remove "boinc_5072841977fb3bee_net" Exit Code: 0 Output: VBoxManage.exe: error: Bandwidth groups cannot be deleted while the VM is running 2021-04-14 21:36:19 (15148): Command: VBoxManage -q unregistervm "boinc_5072841977fb3bee" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 2021-04-14 21:36:19 (15148): Command: VBoxManage -q closemedium dvd "C:\ProgramData\BOINC\slots\3/vm_isocontext.iso" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 21:36:25 (15148): called boinc_finish(-2147467259) </stderr_txt> ]]>
©2024 COPYRIGHT 2017-2018 NCN