Task 10159353

Name 08282279_06_0
Workunit 7966592
Created 15 Apr 2021, 3:49:56 UTC
Sent 15 Apr 2021, 5:22:19 UTC
Report deadline 20 Apr 2021, 5:22:19 UTC
Received 20 Apr 2021, 15:20:47 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status -2147467259 (0x80004005) Unknown error code
Computer ID 10975
Run time 20 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 4.05 GFLOPS
Application version boinc2docker v1.14 (vbox64_mt)
windows_x86_64
Peak working set size 10.91 MB
Peak swap size 6.24 MB
Peak disk usage 498.91 MB

Stderr output

<core_client_version>7.16.11</core_client_version>
<![CDATA[
<message>
Unspecified error
 (0x80004005) - exit code 2147500037 (0x80004005)</message>
<stderr_txt>
2021-04-19 14:11:28 (15608): Detected: vboxwrapper 26202
2021-04-19 14:11:28 (15608): Detected: BOINC client v7.16.11
2021-04-19 14:11:29 (15608): Detected: VirtualBox VboxManage Interface (Version: 6.1.12)
2021-04-19 14:11:30 (15608): Create VM. (boinc_f51d300cbbe93408, slot#1)
2021-04-19 14:11:30 (15608): Updating drive controller type and model for desired configuration.
2021-04-19 14:11:31 (15608): Setting Memory Size for VM. (3072MB)
2021-04-19 14:11:31 (15608): Setting CPU Count for VM. (1)
2021-04-19 14:11:32 (15608): Setting Chipset Options for VM.
2021-04-19 14:11:32 (15608): Setting Boot Options for VM.
2021-04-19 14:11:32 (15608): Setting Network Configuration for NAT.
2021-04-19 14:11:33 (15608): Enabling VM Network Access.
2021-04-19 14:11:33 (15608): Disabling USB Support for VM.
2021-04-19 14:11:34 (15608): Disabling COM Port Support for VM.
2021-04-19 14:11:35 (15608): Disabling LPT Port Support for VM.
2021-04-19 14:11:35 (15608): Disabling Audio Support for VM.
2021-04-19 14:11:35 (15608): Disabling Clipboard Support for VM.
2021-04-19 14:11:36 (15608): Disabling Drag and Drop Support for VM.
2021-04-19 14:11:36 (15608): Adding storage controller(s) to VM.
2021-04-19 14:11:36 (15608): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso)
2021-04-19 14:11:36 (15608): Adding VirtualBox Guest Additions to VM.
2021-04-19 14:11:37 (15608): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2021-04-19 14:11:37 (15608): Enabling shared directory for VM.
2021-04-19 14:11:38 (15608): Starting VM using VBoxManage interface. (boinc_f51d300cbbe93408, slot#1)
2021-04-19 14:11:41 (15608): Error in start VM for VM: -2147467259
Command:
VBoxManage -q startvm "boinc_f51d300cbbe93408" --type headless
Output:
Waiting for VM "boinc_f51d300cbbe93408" to power on...
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole

2021-04-19 14:11:41 (15608): VM failed to start.
2021-04-19 14:11:41 (15608): Could not start 
2021-04-19 14:11:41 (15608): ERROR: VM failed to start
2021-04-19 14:11:41 (15608): Powering off VM.
2021-04-19 14:11:41 (15608): Deregistering VM. (boinc_f51d300cbbe93408, slot#1)
2021-04-19 14:11:41 (15608): Removing network bandwidth throttle group from VM.
2021-04-19 14:11:41 (15608): Removing VM from VirtualBox.
2021-04-19 14:11:41 (15608): Removing virtual ISO 9660 disk from VirtualBox.

    Hypervisor System Log:

00:00:00.139008          usbLibGetDevices: Found 5 USB devices, 0 captured
00:00:00.139123          USB: Unknown USB device detected (idVendor: 0x8087, idProduct: 0x0aa7)
00:00:00.341136          HostDnsMonitor: initializing
00:00:00.349984          HostDnsMonitor: updating information
00:00:00.350009          HostDnsMonitor: old information
00:00:00.350010            no server entries
00:00:00.350011            no domain set
00:00:00.350011            no search string entries
00:00:00.350012          HostDnsMonitor: new information
00:00:00.350012            server 1: 192.168.1.1
00:00:00.350013            no domain set
00:00:00.350013            no search string entries
00:00:00.424338          SUPR0QueryVTCaps -> VERR_VMX_MSR_ALL_VMX_DISABLED
00:00:00.424853          VD: VDInit finished with VINF_SUCCESS
00:00:00.425998          VirtualBox: object created
00:00:00.767020          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={Could not find a registered machine named 'boinc_f51d300cbbe93408'}, preserve=false aResultDetail=0
00:00:01.029408          ERROR [COM]: aRC=VBOX_E_FILE_ERROR (0x80bb0004) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Could not find file for the medium 'C:\ProgramData\BOINC\slots\1\vm_image.vdi' (VERR_FILE_NOT_FOUND)}, preserve=false aResultDetail=-102
00:00:01.300435          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_f51d300cbbe93408\boinc_f51d300cbbe93408.vbox" with version "1.16-windows"
00:00:01.686718          Saving settings file "C:\Users\user\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:01.829522          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_f51d300cbbe93408\boinc_f51d300cbbe93408.vbox" with version "1.16-windows"
00:00:02.094911          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_f51d300cbbe93408\boinc_f51d300cbbe93408.vbox" with version "1.16-windows"
00:00:02.360569          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_f51d300cbbe93408\boinc_f51d300cbbe93408.vbox" with version "1.16-windows"
00:00:03.159519          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_f51d300cbbe93408\boinc_f51d300cbbe93408.vbox" with version "1.16-windows"
00:00:03.464138          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_f51d300cbbe93408\boinc_f51d300cbbe93408.vbox" with version "1.16-windows"
00:00:03.736698          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_f51d300cbbe93408\boinc_f51d300cbbe93408.vbox" with version "1.16-windows"
00:00:04.518100          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_f51d300cbbe93408\boinc_f51d300cbbe93408.vbox" with version "1.16-windows"
00:00:04.784768          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_f51d300cbbe93408\boinc_f51d300cbbe93408.vbox" with version "1.16-windows"
00:00:05.051986          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_f51d300cbbe93408\boinc_f51d300cbbe93408.vbox" with version "1.16-windows"
00:00:05.846064          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_f51d300cbbe93408\boinc_f51d300cbbe93408.vbox" with version "1.16-windows"
00:00:06.112458          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_f51d300cbbe93408\boinc_f51d300cbbe93408.vbox" with version "1.16-windows"
00:00:06.377779          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_f51d300cbbe93408\boinc_f51d300cbbe93408.vbox" with version "1.16-windows"
00:00:06.908440          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_f51d300cbbe93408\boinc_f51d300cbbe93408.vbox" with version "1.16-windows"
00:00:07.176568          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_f51d300cbbe93408\boinc_f51d300cbbe93408.vbox" with version "1.16-windows"
00:00:07.439227          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.443132          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.443283          Saving settings file "C:\Users\user\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:07.470670          Saving settings file "C:\Users\user\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:07.489434          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_f51d300cbbe93408\boinc_f51d300cbbe93408.vbox" with version "1.16-windows"
00:00:07.706990          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.708248          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.708369          Saving settings file "C:\Users\user\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:08.031431          Saving settings file "C:\Users\user\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:08.066417          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_f51d300cbbe93408\boinc_f51d300cbbe93408.vbox" with version "1.16-windows"
00:00:08.235817          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_f51d300cbbe93408\boinc_f51d300cbbe93408.vbox" with version "1.16-windows"
00:00:08.500181          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_f51d300cbbe93408\boinc_f51d300cbbe93408.vbox" with version "1.16-windows"
00:00:08.769062          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.769191          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.775638          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:09.042294          Launched VM: 65745520 pid: 3172 (0xc64) frontend: headless name: boinc_f51d300cbbe93408
00:00:11.813473          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_f51d300cbbe93408\boinc_f51d300cbbe93408.vbox" with version "1.16-windows"
00:00:12.056953          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:12.115018          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_f51d300cbbe93408\boinc_f51d300cbbe93408.vbox" with version "1.16-windows"
00:00:12.379978          Saving settings file "C:\Users\user\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:17.651957 main     VirtualBox: object deletion starts
00:00:17.652517 main     HostDnsMonitor: shutting down ...
00:00:17.652566 main     HostDnsMonitor: shut down
00:00:17.653641 Watcher  ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0
00:00:17.653810 main     VirtualBox: object deleted

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

t:    2
Maximum PIIX3 SATA Controllers:  1
Maximum ICH9 SATA Controllers:   8
Maximum SATA Port count:         30
Maximum Devices per SATA Port:   1
Maximum PIIX3 SCSI Controllers:  1
Maximum ICH9 SCSI Controllers:   8
Maximum SCSI Port count:         16
Maximum Devices per SCSI Port:   1
Maximum SAS PIIX3 Controllers:   1
Maximum SAS ICH9 Controllers:    8
Maximum SAS Port count:          255
Maximum Devices per SAS Port:    1
Maximum NVMe PIIX3 Controllers:  1
Maximum NVMe ICH9 Controllers:   8
Maximum NVMe Port count:         255
Maximum Devices per NVMe Port:   1
Maximum virtio-scsi PIIX3 Controllers:  1
Maximum virtio-scsi ICH9 Controllers:   8
Maximum virtio-scsi Port count:         256
Maximum Devices per virtio-scsi Port:   1
Maximum PIIX3 Floppy Controllers:1
Maximum ICH9 Floppy Controllers: 1
Maximum Floppy Port count:       1
Maximum Devices per Floppy Port: 2
Default machine folder:          C:\Users\user\VirtualBox VMs
Raw-mode Supported:              no
Exclusive HW virtualization use: off
Default hard disk format:        VDI
VRDE auth library:               VBoxAuth
Webservice auth. library:        VBoxAuth
Remote desktop ExtPack:          
Log history count:               3
Default frontend:                
Default audio driver:            DirectSound
Autostart database path:         
Default Guest Additions ISO:     C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso
Logging Level:                   all
Proxy Mode:                      System
Proxy URL:                       

2021-04-19 14:11:29 (15608): 
Command: VBoxManage -q list hostinfo 
Exit Code: 0
Output:
Host Information:

Host time: 2021-04-19T21:11:29.745000000Z
Processor online count: 4
Processor count: 4
Processor online core count: 4
Processor core count: 4
Processor supports HW virtualization: no
Processor supports PAE: yes
Processor supports long mode: yes
Processor supports nested paging: no
Processor supports unrestricted guest: no
Processor supports nested HW virtualization: no
Processor#0 speed: unknown
Processor#0 description: Intel(R) Core(TM) i5-7400 CPU @ 3.00GHz
Processor#1 speed: unknown
Processor#1 description: Intel(R) Core(TM) i5-7400 CPU @ 3.00GHz
Processor#2 speed: unknown
Processor#2 description: Intel(R) Core(TM) i5-7400 CPU @ 3.00GHz
Processor#3 speed: unknown
Processor#3 description: Intel(R) Core(TM) i5-7400 CPU @ 3.00GHz
Memory size: 16303 MByte
Memory available: 11813 MByte
Operating system: Windows 10
Operating system version: 10.0.19042

2021-04-19 14:11:30 (15608): 
Command: VBoxManage -q showvminfo "boinc_f51d300cbbe93408" --machinereadable 
Exit Code: -2135228415
Output:
VBoxManage.exe: error: Could not find a registered machine named 'boinc_f51d300cbbe93408'
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown
VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2715 of file VBoxManageInfo.cpp

2021-04-19 14:11:30 (15608): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\1/vm_image.vdi" 
Exit Code: -2135228412
Output:
VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\1\vm_image.vdi' (VERR_FILE_NOT_FOUND)
VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp

2021-04-19 14:11:31 (15608): 
Command: VBoxManage -q createvm --name "boinc_f51d300cbbe93408" --basefolder "C:\ProgramData\BOINC\slots\1" --ostype "Linux26_64" --register
Exit Code: 0
Output:
Virtual machine 'boinc_f51d300cbbe93408' is created and registered.
UUID: 85b6557a-dc45-4e02-8ea3-5b962525ff40
Settings file: 'C:\ProgramData\BOINC\slots\1\boinc_f51d300cbbe93408\boinc_f51d300cbbe93408.vbox'

2021-04-19 14:11:31 (15608): 
Command: VBoxManage -q modifyvm "boinc_f51d300cbbe93408" --description "08282279_06_0" 
Exit Code: 0
Output:

2021-04-19 14:11:31 (15608): 
Command: VBoxManage -q modifyvm "boinc_f51d300cbbe93408" --memory 3072 
Exit Code: 0
Output:

2021-04-19 14:11:32 (15608): 
Command: VBoxManage -q modifyvm "boinc_f51d300cbbe93408" --cpus 1 
Exit Code: 0
Output:

2021-04-19 14:11:32 (15608): 
Command: VBoxManage -q modifyvm "boinc_f51d300cbbe93408" --acpi on --ioapic on 
Exit Code: 0
Output:

2021-04-19 14:11:32 (15608): 
Command: VBoxManage -q modifyvm "boinc_f51d300cbbe93408" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2021-04-19 14:11:33 (15608): 
Command: VBoxManage -q modifyvm "boinc_f51d300cbbe93408" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2021-04-19 14:11:33 (15608): 
Command: VBoxManage -q modifyvm "boinc_f51d300cbbe93408" --cableconnected1 on 
Exit Code: 0
Output:

2021-04-19 14:11:34 (15608): 
Command: VBoxManage -q modifyvm "boinc_f51d300cbbe93408" --usb off 
Exit Code: 0
Output:

2021-04-19 14:11:35 (15608): 
Command: VBoxManage -q modifyvm "boinc_f51d300cbbe93408" --uart1 off --uart2 off 
Exit Code: 0
Output:

2021-04-19 14:11:35 (15608): 
Command: VBoxManage -q modifyvm "boinc_f51d300cbbe93408" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2021-04-19 14:11:35 (15608): 
Command: VBoxManage -q modifyvm "boinc_f51d300cbbe93408" --audio none 
Exit Code: 0
Output:

2021-04-19 14:11:36 (15608): 
Command: VBoxManage -q modifyvm "boinc_f51d300cbbe93408" --clipboard disabled 
Exit Code: 0
Output:

2021-04-19 14:11:36 (15608): 
Command: VBoxManage -q modifyvm "boinc_f51d300cbbe93408" --draganddrop disabled 
Exit Code: 0
Output:

2021-04-19 14:11:36 (15608): 
Command: VBoxManage -q storagectl "boinc_f51d300cbbe93408" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2021-04-19 14:11:36 (15608): 
Command: VBoxManage -q storageattach "boinc_f51d300cbbe93408" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\ProgramData\BOINC\slots\1/vm_isocontext.iso" 
Exit Code: 0
Output:

2021-04-19 14:11:37 (15608): 
Command: VBoxManage -q storageattach "boinc_f51d300cbbe93408" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2021-04-19 14:11:37 (15608): 
Command: VBoxManage -q bandwidthctl "boinc_f51d300cbbe93408" add "boinc_f51d300cbbe93408_net" --type network --limit 1024G 
Exit Code: 0
Output:

2021-04-19 14:11:37 (15608): 
Command: VBoxManage -q sharedfolder add "boinc_f51d300cbbe93408" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\1/shared"
Exit Code: 0
Output:

2021-04-19 14:11:41 (15608): 
Command: VBoxManage -q startvm "boinc_f51d300cbbe93408" --type headless
Exit Code: -2147467259
Output:
Waiting for VM "boinc_f51d300cbbe93408" to power on...
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole

2021-04-19 14:11:41 (15608): 
Command: VBoxManage -q snapshot "boinc_f51d300cbbe93408" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2021-04-19 14:11:41 (15608): 
Command: VBoxManage -q bandwidthctl "boinc_f51d300cbbe93408" remove "boinc_f51d300cbbe93408_net" 
Exit Code: 0
Output:

2021-04-19 14:11:41 (15608): 
Command: VBoxManage -q unregistervm "boinc_f51d300cbbe93408" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

2021-04-19 14:11:42 (15608): 
Command: VBoxManage -q closemedium dvd "C:\ProgramData\BOINC\slots\1/vm_isocontext.iso" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

14:11:47 (15608): called boinc_finish(-2147467259)

</stderr_txt>
]]>


©2024 COPYRIGHT 2017-2018 NCN