Name | 08282583_02_0 |
Workunit | 7973286 |
Created | 15 Apr 2021, 5:44:40 UTC |
Sent | 15 Apr 2021, 7:25:18 UTC |
Report deadline | 20 Apr 2021, 7:25:18 UTC |
Received | 15 Apr 2021, 10:08:56 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | -2147467259 (0x80004005) Unknown error code |
Computer ID | 11240 |
Run time | 21 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 1.00 GFLOPS |
Application version | boinc2docker v1.14 (vbox64_mt) windows_x86_64 |
Peak working set size | 11.47 MB |
Peak swap size | 6.21 MB |
Peak disk usage | 602.14 MB |
<core_client_version>7.16.11</core_client_version> <![CDATA[ <message> Unspecified error (0x80004005) - exit code 2147500037 (0x80004005)</message> <stderr_txt> 2021-04-15 00:27:29 (6800): Detected: vboxwrapper 26202 2021-04-15 00:27:29 (6800): Detected: BOINC client v7.16.11 2021-04-15 00:27:30 (6800): Detected: VirtualBox VboxManage Interface (Version: 6.1.12) 2021-04-15 00:27:31 (6800): Create VM. (boinc_573d6d0851371fc3, slot#18) 2021-04-15 00:27:31 (6800): Updating drive controller type and model for desired configuration. 2021-04-15 00:27:31 (6800): Setting Memory Size for VM. (3072MB) 2021-04-15 00:27:32 (6800): Setting CPU Count for VM. (1) 2021-04-15 00:27:32 (6800): Setting Chipset Options for VM. 2021-04-15 00:27:32 (6800): Setting Boot Options for VM. 2021-04-15 00:27:32 (6800): Setting Network Configuration for NAT. 2021-04-15 00:27:33 (6800): Enabling VM Network Access. 2021-04-15 00:27:33 (6800): Disabling USB Support for VM. 2021-04-15 00:27:33 (6800): Disabling COM Port Support for VM. 2021-04-15 00:27:33 (6800): Disabling LPT Port Support for VM. 2021-04-15 00:27:34 (6800): Disabling Audio Support for VM. 2021-04-15 00:27:34 (6800): Disabling Clipboard Support for VM. 2021-04-15 00:27:34 (6800): Disabling Drag and Drop Support for VM. 2021-04-15 00:27:34 (6800): Adding storage controller(s) to VM. 2021-04-15 00:27:35 (6800): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso) 2021-04-15 00:27:35 (6800): Adding VirtualBox Guest Additions to VM. 2021-04-15 00:27:35 (6800): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2021-04-15 00:27:36 (6800): Enabling shared directory for VM. 2021-04-15 00:27:36 (6800): Starting VM using VBoxManage interface. (boinc_573d6d0851371fc3, slot#18) 2021-04-15 00:27:39 (6800): Error in start VM for VM: -2147467259 Command: VBoxManage -q startvm "boinc_573d6d0851371fc3" --type headless Output: Waiting for VM "boinc_573d6d0851371fc3" to power on... VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2021-04-15 00:27:39 (6800): VM failed to start. 2021-04-15 00:27:39 (6800): Could not start 2021-04-15 00:27:39 (6800): ERROR: VM failed to start 2021-04-15 00:27:39 (6800): Powering off VM. 2021-04-15 00:27:39 (6800): Deregistering VM. (boinc_573d6d0851371fc3, slot#18) 2021-04-15 00:27:39 (6800): Removing network bandwidth throttle group from VM. 2021-04-15 00:27:40 (6800): Removing VM from VirtualBox. 2021-04-15 00:27:40 (6800): Removing virtual ISO 9660 disk from VirtualBox. Hypervisor System Log: 00:00:07.701580 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.708071 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:07.859152 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.859296 Saving settings file "C:\ProgramData\BOINC\slots\21\boinc_c5fa337e38f83c33\boinc_c5fa337e38f83c33.vbox" with version "1.16-windows" 00:00:07.866598 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.866973 Saving settings file "C:\Users\haris\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:07.870489 Saving settings file "C:\Users\haris\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:07.873288 Saving settings file "C:\ProgramData\BOINC\slots\22\boinc_f47c0a4690947ed8\boinc_f47c0a4690947ed8.vbox" with version "1.16-windows" 00:00:07.967918 Launched VM: 65239808 pid: 13104 (0x3330) frontend: headless name: boinc_b9758202c777656f 00:00:08.130192 Saving settings file "C:\ProgramData\BOINC\slots\21\boinc_c5fa337e38f83c33\boinc_c5fa337e38f83c33.vbox" with version "1.16-windows" 00:00:08.130365 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.130781 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.131342 Saving settings file "C:\ProgramData\BOINC\slots\22\boinc_f47c0a4690947ed8\boinc_f47c0a4690947ed8.vbox" with version "1.16-windows" 00:00:08.426238 Saving settings file "C:\ProgramData\BOINC\slots\22\boinc_f47c0a4690947ed8\boinc_f47c0a4690947ed8.vbox" with version "1.16-windows" 00:00:08.430046 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.430210 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.435367 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:08.678486 Saving settings file "C:\ProgramData\BOINC\slots\22\boinc_f47c0a4690947ed8\boinc_f47c0a4690947ed8.vbox" with version "1.16-windows" 00:00:08.688248 Launched VM: 64195472 pid: 6472 (0x1948) frontend: headless name: boinc_c5fa337e38f83c33 00:00:08.958754 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.958907 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.964388 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:09.219706 Launched VM: 64701088 pid: 15252 (0x3b94) frontend: headless name: boinc_f47c0a4690947ed8 00:00:10.039585 Saving settings file "C:\ProgramData\BOINC\slots\18\boinc_573d6d0851371fc3\boinc_573d6d0851371fc3.vbox" with version "1.16-windows" 00:00:10.039811 Saving settings file "C:\ProgramData\BOINC\slots\17\boinc_494ffdae8af2f130\boinc_494ffdae8af2f130.vbox" with version "1.16-windows" 00:00:10.140826 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:10.146150 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:10.501210 Saving settings file "C:\Users\haris\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:10.505335 Saving settings file "C:\Users\haris\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:10.654805 Saving settings file "C:\ProgramData\BOINC\slots\19\boinc_a28a9d6d1c33c3ce\boinc_a28a9d6d1c33c3ce.vbox" with version "1.16-windows" 00:00:10.744794 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:11.074083 Saving settings file "C:\Users\haris\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:11.167249 Saving settings file "C:\ProgramData\BOINC\slots\20\boinc_b9758202c777656f\boinc_b9758202c777656f.vbox" with version "1.16-windows" 00:00:11.245417 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:11.573353 Saving settings file "C:\Users\haris\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:11.688718 Saving settings file "C:\ProgramData\BOINC\slots\21\boinc_c5fa337e38f83c33\boinc_c5fa337e38f83c33.vbox" with version "1.16-windows" 00:00:11.765258 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:12.088594 Saving settings file "C:\Users\haris\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:12.208151 Saving settings file "C:\ProgramData\BOINC\slots\22\boinc_f47c0a4690947ed8\boinc_f47c0a4690947ed8.vbox" with version "1.16-windows" 00:00:12.288072 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:12.620899 Saving settings file "C:\Users\haris\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:17.899615 main VirtualBox: object deletion starts 00:00:17.900959 main HostDnsMonitor: shutting down ... 00:00:17.901059 main HostDnsMonitor: shut down 00:00:17.902534 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:17.902856 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: 3 Default frontend: Default audio driver: DirectSound Autostart database path: Default Guest Additions ISO: C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso Logging Level: all Proxy Mode: System Proxy URL: 2021-04-15 00:27:30 (6800): Command: VBoxManage -q list hostinfo Exit Code: 0 Output: Host Information: Host time: 2021-04-15T07:27:30.492000000Z Processor online count: 16 Processor count: 16 Processor online core count: 8 Processor core count: 8 Processor supports HW virtualization: no Processor supports PAE: yes Processor supports long mode: yes Processor supports nested paging: no Processor supports unrestricted guest: no Processor supports nested HW virtualization: no Processor#0 speed: unknown Processor#0 description: Intel(R) Core(TM) i7-10700K CPU @ 3.80GHz Processor#1 speed: unknown Processor#1 description: Intel(R) Core(TM) i7-10700K CPU @ 3.80GHz Processor#2 speed: unknown Processor#2 description: Intel(R) Core(TM) i7-10700K CPU @ 3.80GHz Processor#3 speed: unknown Processor#3 description: Intel(R) Core(TM) i7-10700K CPU @ 3.80GHz Processor#4 speed: unknown Processor#4 description: Intel(R) Core(TM) i7-10700K CPU @ 3.80GHz Processor#5 speed: unknown Processor#5 description: Intel(R) Core(TM) i7-10700K CPU @ 3.80GHz Processor#6 speed: unknown Processor#6 description: Intel(R) Core(TM) i7-10700K CPU @ 3.80GHz Processor#7 speed: unknown Processor#7 description: Intel(R) Core(TM) i7-10700K CPU @ 3.80GHz Processor#8 speed: unknown Processor#8 description: Intel(R) Core(TM) i7-10700K CPU @ 3.80GHz Processor#9 speed: unknown Processor#9 description: Intel(R) Core(TM) i7-10700K CPU @ 3.80GHz Processor#10 speed: unknown Processor#10 description: Intel(R) Core(TM) i7-10700K CPU @ 3.80GHz Processor#11 speed: unknown Processor#11 description: Intel(R) Core(TM) i7-10700K CPU @ 3.80GHz Processor#12 speed: unknown Processor#12 description: Intel(R) Core(TM) i7-10700K CPU @ 3.80GHz Processor#13 speed: unknown Processor#13 description: Intel(R) Core(TM) i7-10700K CPU @ 3.80GHz Processor#14 speed: unknown Processor#14 description: Intel(R) Core(TM) i7-10700K CPU @ 3.80GHz Processor#15 speed: unknown Processor#15 description: Intel(R) Core(TM) i7-10700K CPU @ 3.80GHz Memory size: 32616 MByte Memory available: 6812 MByte Operating system: Windows 10 Operating system version: 10.0.19042 2021-04-15 00:27:30 (6800): Command: VBoxManage -q showvminfo "boinc_573d6d0851371fc3" --machinereadable Exit Code: -2135228415 Output: VBoxManage.exe: error: Could not find a registered machine named 'boinc_573d6d0851371fc3' VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2715 of file VBoxManageInfo.cpp 2021-04-15 00:27:31 (6800): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\18/vm_image.vdi" Exit Code: -2135228412 Output: VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\18\vm_image.vdi' (VERR_FILE_NOT_FOUND) VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp 2021-04-15 00:27:31 (6800): Command: VBoxManage -q createvm --name "boinc_573d6d0851371fc3" --basefolder "C:\ProgramData\BOINC\slots\18" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_573d6d0851371fc3' is created and registered. UUID: 7a347e76-c0b2-4356-b76e-bbf40b87f3af Settings file: 'C:\ProgramData\BOINC\slots\18\boinc_573d6d0851371fc3\boinc_573d6d0851371fc3.vbox' 2021-04-15 00:27:31 (6800): Command: VBoxManage -q modifyvm "boinc_573d6d0851371fc3" --description "08282583_02_0" Exit Code: 0 Output: 2021-04-15 00:27:32 (6800): Command: VBoxManage -q modifyvm "boinc_573d6d0851371fc3" --memory 3072 Exit Code: 0 Output: 2021-04-15 00:27:32 (6800): Command: VBoxManage -q modifyvm "boinc_573d6d0851371fc3" --cpus 1 Exit Code: 0 Output: 2021-04-15 00:27:32 (6800): Command: VBoxManage -q modifyvm "boinc_573d6d0851371fc3" --acpi on --ioapic on Exit Code: 0 Output: 2021-04-15 00:27:32 (6800): Command: VBoxManage -q modifyvm "boinc_573d6d0851371fc3" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2021-04-15 00:27:33 (6800): Command: VBoxManage -q modifyvm "boinc_573d6d0851371fc3" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2021-04-15 00:27:33 (6800): Command: VBoxManage -q modifyvm "boinc_573d6d0851371fc3" --cableconnected1 on Exit Code: 0 Output: 2021-04-15 00:27:33 (6800): Command: VBoxManage -q modifyvm "boinc_573d6d0851371fc3" --usb off Exit Code: 0 Output: 2021-04-15 00:27:33 (6800): Command: VBoxManage -q modifyvm "boinc_573d6d0851371fc3" --uart1 off --uart2 off Exit Code: 0 Output: 2021-04-15 00:27:34 (6800): Command: VBoxManage -q modifyvm "boinc_573d6d0851371fc3" --lpt1 off --lpt2 off Exit Code: 0 Output: 2021-04-15 00:27:34 (6800): Command: VBoxManage -q modifyvm "boinc_573d6d0851371fc3" --audio none Exit Code: 0 Output: 2021-04-15 00:27:34 (6800): Command: VBoxManage -q modifyvm "boinc_573d6d0851371fc3" --clipboard disabled Exit Code: 0 Output: 2021-04-15 00:27:34 (6800): Command: VBoxManage -q modifyvm "boinc_573d6d0851371fc3" --draganddrop disabled Exit Code: 0 Output: 2021-04-15 00:27:35 (6800): Command: VBoxManage -q storagectl "boinc_573d6d0851371fc3" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2021-04-15 00:27:35 (6800): Command: VBoxManage -q storageattach "boinc_573d6d0851371fc3" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\ProgramData\BOINC\slots\18/vm_isocontext.iso" Exit Code: 0 Output: 2021-04-15 00:27:35 (6800): Command: VBoxManage -q storageattach "boinc_573d6d0851371fc3" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2021-04-15 00:27:36 (6800): Command: VBoxManage -q bandwidthctl "boinc_573d6d0851371fc3" add "boinc_573d6d0851371fc3_net" --type network --limit 1024G Exit Code: 0 Output: 2021-04-15 00:27:36 (6800): Command: VBoxManage -q sharedfolder add "boinc_573d6d0851371fc3" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\18/shared" Exit Code: 0 Output: 2021-04-15 00:27:39 (6800): Command: VBoxManage -q startvm "boinc_573d6d0851371fc3" --type headless Exit Code: -2147467259 Output: Waiting for VM "boinc_573d6d0851371fc3" to power on... VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2021-04-15 00:27:39 (6800): Command: VBoxManage -q snapshot "boinc_573d6d0851371fc3" list Exit Code: -108 Output: This machine does not have any snapshots 2021-04-15 00:27:40 (6800): Command: VBoxManage -q bandwidthctl "boinc_573d6d0851371fc3" remove "boinc_573d6d0851371fc3_net" Exit Code: 0 Output: VBoxManage.exe: error: Bandwidth groups cannot be deleted while the VM is running 2021-04-15 00:27:40 (6800): Command: VBoxManage -q unregistervm "boinc_573d6d0851371fc3" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 2021-04-15 00:27:40 (6800): Command: VBoxManage -q closemedium dvd "C:\ProgramData\BOINC\slots\18/vm_isocontext.iso" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 00:27:48 (6800): called boinc_finish(-2147467259) </stderr_txt> ]]>
©2025 COPYRIGHT 2017-2018 NCN