Task 10171532

Name 08280038_08_1
Workunit 7927125
Created 15 Apr 2021, 7:02:26 UTC
Sent 15 Apr 2021, 7:03:39 UTC
Report deadline 20 Apr 2021, 7:03:39 UTC
Received 15 Apr 2021, 9:41:35 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status 1 (0x00000001) Unknown error code
Computer ID 10669
Run time 21 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 5.09 GFLOPS
Application version boinc2docker v1.14 (vbox64_mt)
windows_x86_64
Peak working set size 10.88 MB
Peak swap size 6.21 MB
Peak disk usage 227.21 MB

Stderr output

<core_client_version>7.16.11</core_client_version>
<![CDATA[
<message>
Funzione non corretta.
 (0x1) - exit code 1 (0x1)</message>
<stderr_txt>
2021-04-15 11:05:14 (5472): Detected: vboxwrapper 26202
2021-04-15 11:05:14 (5472): Detected: BOINC client v7.16.11
2021-04-15 11:05:14 (5472): Detected: VirtualBox VboxManage Interface (Version: 6.1.12)
2021-04-15 11:05:15 (5472): Create VM. (boinc_6e51e5456a68fe06, slot#13)
2021-04-15 11:05:15 (5472): Updating drive controller type and model for desired configuration.
2021-04-15 11:05:16 (5472): Setting Memory Size for VM. (3072MB)
2021-04-15 11:05:16 (5472): Setting CPU Count for VM. (1)
2021-04-15 11:05:16 (5472): Setting Chipset Options for VM.
2021-04-15 11:05:17 (5472): Setting Boot Options for VM.
2021-04-15 11:05:17 (5472): Setting Network Configuration for NAT.
2021-04-15 11:05:17 (5472): Enabling VM Network Access.
2021-04-15 11:05:17 (5472): Disabling USB Support for VM.
2021-04-15 11:05:18 (5472): Disabling COM Port Support for VM.
2021-04-15 11:05:18 (5472): Disabling LPT Port Support for VM.
2021-04-15 11:05:18 (5472): Disabling Audio Support for VM.
2021-04-15 11:05:18 (5472): Disabling Clipboard Support for VM.
2021-04-15 11:05:19 (5472): Disabling Drag and Drop Support for VM.
2021-04-15 11:05:19 (5472): Adding storage controller(s) to VM.
2021-04-15 11:05:19 (5472): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso)
2021-04-15 11:05:19 (5472): Adding VirtualBox Guest Additions to VM.
2021-04-15 11:05:20 (5472): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2021-04-15 11:05:20 (5472): Enabling shared directory for VM.
2021-04-15 11:05:20 (5472): Starting VM using VBoxManage interface. (boinc_6e51e5456a68fe06, slot#13)
2021-04-15 11:05:22 (5472): Error in start VM for VM: 1
Command:
VBoxManage -q startvm "boinc_6e51e5456a68fe06" --type headless
Output:
Waiting for VM "boinc_6e51e5456a68fe06" to power on...
VBoxManage.exe: error: The virtual machine 'boinc_6e51e5456a68fe06' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\13\boinc_6e51e5456a68fe06\Logs\VBoxHardening.log'
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine

2021-04-15 11:05:22 (5472): VM failed to start.
2021-04-15 11:05:22 (5472): Could not start 
2021-04-15 11:05:22 (5472): ERROR: VM failed to start
2021-04-15 11:05:22 (5472): Powering off VM.
2021-04-15 11:05:22 (5472): Deregistering VM. (boinc_6e51e5456a68fe06, slot#13)
2021-04-15 11:05:22 (5472): Removing network bandwidth throttle group from VM.
2021-04-15 11:05:22 (5472): Removing VM from VirtualBox.
2021-04-15 11:05:23 (5472): Removing virtual ISO 9660 disk from VirtualBox.

    Hypervisor System Log:

02:02:29.744244          Saving settings file "C:\ProgramData\BOINC\slots\12\boinc_5b56e05c842aee4a\boinc_5b56e05c842aee4a.vbox" with version "1.16-windows"
02:02:29.996042          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
02:02:29.996148          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
02:02:30.003096          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
02:02:30.252648          Launched VM: 74411760 pid: 14180 (0x3764) frontend: headless name: boinc_5b56e05c842aee4a
02:02:35.930721          Saving settings file "C:\ProgramData\BOINC\slots\12\boinc_5b56e05c842aee4a\boinc_5b56e05c842aee4a.vbox" with version "1.16-windows"
02:02:37.889251          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={Could not find a registered machine named 'boinc_6e51e5456a68fe06'}, preserve=false aResultDetail=0
02:02:38.138603          ERROR [COM]: aRC=VBOX_E_FILE_ERROR (0x80bb0004) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Could not find file for the medium 'C:\ProgramData\BOINC\slots\13\vm_image.vdi' (VERR_FILE_NOT_FOUND)}, preserve=false aResultDetail=-102
02:02:38.401598          Saving settings file "C:\ProgramData\BOINC\slots\13\boinc_6e51e5456a68fe06\boinc_6e51e5456a68fe06.vbox" with version "1.16-windows"
02:02:38.411267          Saving settings file "C:\Users\DadoQUATER\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
02:02:38.654857          Saving settings file "C:\ProgramData\BOINC\slots\13\boinc_6e51e5456a68fe06\boinc_6e51e5456a68fe06.vbox" with version "1.16-windows"
02:02:38.919762          Saving settings file "C:\ProgramData\BOINC\slots\13\boinc_6e51e5456a68fe06\boinc_6e51e5456a68fe06.vbox" with version "1.16-windows"
02:02:39.173233          Saving settings file "C:\ProgramData\BOINC\slots\13\boinc_6e51e5456a68fe06\boinc_6e51e5456a68fe06.vbox" with version "1.16-windows"
02:02:39.416720          Saving settings file "C:\ProgramData\BOINC\slots\13\boinc_6e51e5456a68fe06\boinc_6e51e5456a68fe06.vbox" with version "1.16-windows"
02:02:39.669995          Saving settings file "C:\ProgramData\BOINC\slots\13\boinc_6e51e5456a68fe06\boinc_6e51e5456a68fe06.vbox" with version "1.16-windows"
02:02:39.926741          Saving settings file "C:\ProgramData\BOINC\slots\13\boinc_6e51e5456a68fe06\boinc_6e51e5456a68fe06.vbox" with version "1.16-windows"
02:02:40.178163          Saving settings file "C:\ProgramData\BOINC\slots\13\boinc_6e51e5456a68fe06\boinc_6e51e5456a68fe06.vbox" with version "1.16-windows"
02:02:40.433987          Saving settings file "C:\ProgramData\BOINC\slots\13\boinc_6e51e5456a68fe06\boinc_6e51e5456a68fe06.vbox" with version "1.16-windows"
02:02:40.706978          Saving settings file "C:\ProgramData\BOINC\slots\13\boinc_6e51e5456a68fe06\boinc_6e51e5456a68fe06.vbox" with version "1.16-windows"
02:02:40.957376          Saving settings file "C:\ProgramData\BOINC\slots\13\boinc_6e51e5456a68fe06\boinc_6e51e5456a68fe06.vbox" with version "1.16-windows"
02:02:41.277512          Saving settings file "C:\ProgramData\BOINC\slots\13\boinc_6e51e5456a68fe06\boinc_6e51e5456a68fe06.vbox" with version "1.16-windows"
02:02:41.459000          Saving settings file "C:\ProgramData\BOINC\slots\13\boinc_6e51e5456a68fe06\boinc_6e51e5456a68fe06.vbox" with version "1.16-windows"
02:02:41.715329          Saving settings file "C:\ProgramData\BOINC\slots\13\boinc_6e51e5456a68fe06\boinc_6e51e5456a68fe06.vbox" with version "1.16-windows"
02:02:41.961084          Saving settings file "C:\ProgramData\BOINC\slots\13\boinc_6e51e5456a68fe06\boinc_6e51e5456a68fe06.vbox" with version "1.16-windows"
02:02:42.213945          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
02:02:42.215850          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
02:02:42.216078          Saving settings file "C:\Users\DadoQUATER\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
02:02:42.221166          Saving settings file "C:\Users\DadoQUATER\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
02:02:42.224194          Saving settings file "C:\ProgramData\BOINC\slots\13\boinc_6e51e5456a68fe06\boinc_6e51e5456a68fe06.vbox" with version "1.16-windows"
02:02:42.466102          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
02:02:42.466425          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
02:02:42.466836          Saving settings file "C:\ProgramData\BOINC\slots\13\boinc_6e51e5456a68fe06\boinc_6e51e5456a68fe06.vbox" with version "1.16-windows"
02:02:42.719443          Saving settings file "C:\ProgramData\BOINC\slots\13\boinc_6e51e5456a68fe06\boinc_6e51e5456a68fe06.vbox" with version "1.16-windows"
02:02:42.974042          Saving settings file "C:\ProgramData\BOINC\slots\13\boinc_6e51e5456a68fe06\boinc_6e51e5456a68fe06.vbox" with version "1.16-windows"
02:02:43.234105          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
02:02:43.234227          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
02:02:43.240247          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
02:02:43.496015          Launched VM: 82774608 pid: 9736 (0x2608) frontend: headless name: boinc_6e51e5456a68fe06
02:02:45.176547 Watcher  ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={The virtual machine 'boinc_6e51e5456a68fe06' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\13\boinc_6e51e5456a68fe06\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0
02:02:45.227738          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
02:02:45.277563          Saving settings file "C:\ProgramData\BOINC\slots\13\boinc_6e51e5456a68fe06\boinc_6e51e5456a68fe06.vbox" with version "1.16-windows"
02:02:45.523654          Saving settings file "C:\Users\DadoQUATER\.VirtualBox\VirtualBox.xml" with version "1.12-windows"

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

emote desktop ExtPack:          
Log history count:               3
Default frontend:                
Default audio driver:            DirectSound
Autostart database path:         
Default Guest Additions ISO:     C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso
Logging Level:                   all
Proxy Mode:                      System
Proxy URL:                       

2021-04-15 11:05:15 (5472): 
Command: VBoxManage -q list hostinfo 
Exit Code: 0
Output:
Host Information:

Host time: 2021-04-15T09:05:14.851000000Z
Processor online count: 16
Processor count: 16
Processor online core count: 8
Processor core count: 8
Processor supports HW virtualization: yes
Processor supports PAE: yes
Processor supports long mode: yes
Processor supports nested paging: yes
Processor supports unrestricted guest: yes
Processor supports nested HW virtualization: yes
Processor#0 speed: unknown
Processor#0 description: Intel(R) Core(TM) i9-9900 CPU @ 3.10GHz
Processor#1 speed: unknown
Processor#1 description: Intel(R) Core(TM) i9-9900 CPU @ 3.10GHz
Processor#2 speed: unknown
Processor#2 description: Intel(R) Core(TM) i9-9900 CPU @ 3.10GHz
Processor#3 speed: unknown
Processor#3 description: Intel(R) Core(TM) i9-9900 CPU @ 3.10GHz
Processor#4 speed: unknown
Processor#4 description: Intel(R) Core(TM) i9-9900 CPU @ 3.10GHz
Processor#5 speed: unknown
Processor#5 description: Intel(R) Core(TM) i9-9900 CPU @ 3.10GHz
Processor#6 speed: unknown
Processor#6 description: Intel(R) Core(TM) i9-9900 CPU @ 3.10GHz
Processor#7 speed: unknown
Processor#7 description: Intel(R) Core(TM) i9-9900 CPU @ 3.10GHz
Processor#8 speed: unknown
Processor#8 description: Intel(R) Core(TM) i9-9900 CPU @ 3.10GHz
Processor#9 speed: unknown
Processor#9 description: Intel(R) Core(TM) i9-9900 CPU @ 3.10GHz
Processor#10 speed: unknown
Processor#10 description: Intel(R) Core(TM) i9-9900 CPU @ 3.10GHz
Processor#11 speed: unknown
Processor#11 description: Intel(R) Core(TM) i9-9900 CPU @ 3.10GHz
Processor#12 speed: unknown
Processor#12 description: Intel(R) Core(TM) i9-9900 CPU @ 3.10GHz
Processor#13 speed: unknown
Processor#13 description: Intel(R) Core(TM) i9-9900 CPU @ 3.10GHz
Processor#14 speed: unknown
Processor#14 description: Intel(R) Core(TM) i9-9900 CPU @ 3.10GHz
Processor#15 speed: unknown
Processor#15 description: Intel(R) Core(TM) i9-9900 CPU @ 3.10GHz
Memory size: 32610 MByte
Memory available: 6952 MByte
Operating system: Windows 10
Operating system version: 10.0.19042

2021-04-15 11:05:15 (5472): 
Command: VBoxManage -q showvminfo "boinc_6e51e5456a68fe06" --machinereadable 
Exit Code: -2135228415
Output:
VBoxManage.exe: error: Could not find a registered machine named 'boinc_6e51e5456a68fe06'
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown
VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2715 of file VBoxManageInfo.cpp

2021-04-15 11:05:15 (5472): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\13/vm_image.vdi" 
Exit Code: -2135228412
Output:
VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\13\vm_image.vdi' (VERR_FILE_NOT_FOUND)
VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp

2021-04-15 11:05:15 (5472): 
Command: VBoxManage -q createvm --name "boinc_6e51e5456a68fe06" --basefolder "C:\ProgramData\BOINC\slots\13" --ostype "Linux26_64" --register
Exit Code: 0
Output:
Virtual machine 'boinc_6e51e5456a68fe06' is created and registered.
UUID: 1cff0449-87a1-4e47-a851-94147b517618
Settings file: 'C:\ProgramData\BOINC\slots\13\boinc_6e51e5456a68fe06\boinc_6e51e5456a68fe06.vbox'

2021-04-15 11:05:16 (5472): 
Command: VBoxManage -q modifyvm "boinc_6e51e5456a68fe06" --description "08280038_08_1" 
Exit Code: 0
Output:

2021-04-15 11:05:16 (5472): 
Command: VBoxManage -q modifyvm "boinc_6e51e5456a68fe06" --memory 3072 
Exit Code: 0
Output:

2021-04-15 11:05:16 (5472): 
Command: VBoxManage -q modifyvm "boinc_6e51e5456a68fe06" --cpus 1 
Exit Code: 0
Output:

2021-04-15 11:05:17 (5472): 
Command: VBoxManage -q modifyvm "boinc_6e51e5456a68fe06" --acpi on --ioapic on 
Exit Code: 0
Output:

2021-04-15 11:05:17 (5472): 
Command: VBoxManage -q modifyvm "boinc_6e51e5456a68fe06" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2021-04-15 11:05:17 (5472): 
Command: VBoxManage -q modifyvm "boinc_6e51e5456a68fe06" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2021-04-15 11:05:17 (5472): 
Command: VBoxManage -q modifyvm "boinc_6e51e5456a68fe06" --cableconnected1 on 
Exit Code: 0
Output:

2021-04-15 11:05:18 (5472): 
Command: VBoxManage -q modifyvm "boinc_6e51e5456a68fe06" --usb off 
Exit Code: 0
Output:

2021-04-15 11:05:18 (5472): 
Command: VBoxManage -q modifyvm "boinc_6e51e5456a68fe06" --uart1 off --uart2 off 
Exit Code: 0
Output:

2021-04-15 11:05:18 (5472): 
Command: VBoxManage -q modifyvm "boinc_6e51e5456a68fe06" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2021-04-15 11:05:18 (5472): 
Command: VBoxManage -q modifyvm "boinc_6e51e5456a68fe06" --audio none 
Exit Code: 0
Output:

2021-04-15 11:05:19 (5472): 
Command: VBoxManage -q modifyvm "boinc_6e51e5456a68fe06" --clipboard disabled 
Exit Code: 0
Output:

2021-04-15 11:05:19 (5472): 
Command: VBoxManage -q modifyvm "boinc_6e51e5456a68fe06" --draganddrop disabled 
Exit Code: 0
Output:

2021-04-15 11:05:19 (5472): 
Command: VBoxManage -q storagectl "boinc_6e51e5456a68fe06" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2021-04-15 11:05:19 (5472): 
Command: VBoxManage -q storageattach "boinc_6e51e5456a68fe06" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\ProgramData\BOINC\slots\13/vm_isocontext.iso" 
Exit Code: 0
Output:

2021-04-15 11:05:20 (5472): 
Command: VBoxManage -q storageattach "boinc_6e51e5456a68fe06" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2021-04-15 11:05:20 (5472): 
Command: VBoxManage -q bandwidthctl "boinc_6e51e5456a68fe06" add "boinc_6e51e5456a68fe06_net" --type network --limit 1024G 
Exit Code: 0
Output:

2021-04-15 11:05:20 (5472): 
Command: VBoxManage -q sharedfolder add "boinc_6e51e5456a68fe06" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\13/shared"
Exit Code: 0
Output:

2021-04-15 11:05:22 (5472): 
Command: VBoxManage -q startvm "boinc_6e51e5456a68fe06" --type headless
Exit Code: 1
Output:
Waiting for VM "boinc_6e51e5456a68fe06" to power on...
VBoxManage.exe: error: The virtual machine 'boinc_6e51e5456a68fe06' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\13\boinc_6e51e5456a68fe06\Logs\VBoxHardening.log'
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine

2021-04-15 11:05:22 (5472): 
Command: VBoxManage -q snapshot "boinc_6e51e5456a68fe06" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2021-04-15 11:05:22 (5472): 
Command: VBoxManage -q bandwidthctl "boinc_6e51e5456a68fe06" remove "boinc_6e51e5456a68fe06_net" 
Exit Code: 0
Output:

2021-04-15 11:05:23 (5472): 
Command: VBoxManage -q unregistervm "boinc_6e51e5456a68fe06" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

2021-04-15 11:05:23 (5472): 
Command: VBoxManage -q closemedium dvd "C:\ProgramData\BOINC\slots\13/vm_isocontext.iso" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

11:05:33 (5472): called boinc_finish(1)

</stderr_txt>
]]>


©2024 COPYRIGHT 2017-2018 NCN