Task 10172282

Name 08282845_19_0
Workunit 7978470
Created 15 Apr 2021, 7:43:45 UTC
Sent 15 Apr 2021, 10:02:08 UTC
Report deadline 20 Apr 2021, 10:02:08 UTC
Received 16 Apr 2021, 3:04:29 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status -2147467259 (0x80004005) Unknown error code
Computer ID 9552
Run time 39 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 3.18 GFLOPS
Application version boinc2docker v1.14 (vbox64_mt)
windows_x86_64
Peak working set size 10.90 MB
Peak swap size 6.20 MB
Peak disk usage 278.17 MB

Stderr output

<core_client_version>7.16.11</core_client_version>
<![CDATA[
<message>
Unspecified error
 (0x80004005) - exit code 2147500037 (0x80004005)</message>
<stderr_txt>
2021-04-15 06:41:50 (15060): Detected: vboxwrapper 26202
2021-04-15 06:41:50 (15060): Detected: BOINC client v7.16.11
2021-04-15 06:41:52 (15060): Detected: VirtualBox VboxManage Interface (Version: 6.1.18)
2021-04-15 06:41:54 (15060): Create VM. (boinc_b94ccdd0f7018a05, slot#3)
2021-04-15 06:41:54 (15060): Updating drive controller type and model for desired configuration.
2021-04-15 06:41:56 (15060): Setting Memory Size for VM. (3072MB)
2021-04-15 06:41:56 (15060): Setting CPU Count for VM. (1)
2021-04-15 06:41:56 (15060): Setting Chipset Options for VM.
2021-04-15 06:41:57 (15060): Setting Boot Options for VM.
2021-04-15 06:41:57 (15060): Setting Network Configuration for NAT.
2021-04-15 06:41:57 (15060): Enabling VM Network Access.
2021-04-15 06:41:58 (15060): Disabling USB Support for VM.
2021-04-15 06:41:58 (15060): Disabling COM Port Support for VM.
2021-04-15 06:41:58 (15060): Disabling LPT Port Support for VM.
2021-04-15 06:41:59 (15060): Disabling Audio Support for VM.
2021-04-15 06:41:59 (15060): Disabling Clipboard Support for VM.
2021-04-15 06:41:59 (15060): Disabling Drag and Drop Support for VM.
2021-04-15 06:41:59 (15060): Adding storage controller(s) to VM.
2021-04-15 06:42:00 (15060): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso)
2021-04-15 06:42:00 (15060): Adding VirtualBox Guest Additions to VM.
2021-04-15 06:42:00 (15060): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2021-04-15 06:42:01 (15060): Enabling shared directory for VM.
2021-04-15 06:42:01 (15060): Starting VM using VBoxManage interface. (boinc_b94ccdd0f7018a05, slot#3)
2021-04-15 06:42:07 (15060): Error in start VM for VM: -2147467259
Command:
VBoxManage -q startvm "boinc_b94ccdd0f7018a05" --type headless
Output:
Waiting for VM "boinc_b94ccdd0f7018a05" to power on...
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: AMD-V is disabled in the BIOS (or by the host OS) (VERR_SVM_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole

2021-04-15 06:42:07 (15060): VM failed to start.
2021-04-15 06:42:07 (15060): Could not start 
2021-04-15 06:42:07 (15060): ERROR: VM failed to start
2021-04-15 06:42:07 (15060): Powering off VM.
2021-04-15 06:42:07 (15060): Deregistering VM. (boinc_b94ccdd0f7018a05, slot#3)
2021-04-15 06:42:07 (15060): Removing network bandwidth throttle group from VM.
2021-04-15 06:42:08 (15060): Removing VM from VirtualBox.
2021-04-15 06:42:08 (15060): Removing virtual ISO 9660 disk from VirtualBox.

    Hypervisor System Log:

00:00:10.229271          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_b7501b10738b156e\boinc_b7501b10738b156e.vbox" with version "1.16-windows"
00:00:10.262002          Saving settings file "C:\Users\User\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:10.296729          Saving settings file "C:\Users\User\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:10.346250          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_b94ccdd0f7018a05\boinc_b94ccdd0f7018a05.vbox" with version "1.16-windows"
00:00:10.510641          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_b94ccdd0f7018a05\boinc_b94ccdd0f7018a05.vbox" with version "1.16-windows"
00:00:10.652061          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:10.652882          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:10.653526          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_b88c5fb52318358b\boinc_b88c5fb52318358b.vbox" with version "1.16-windows"
00:00:10.691078          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:10.691669          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:10.692478          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_b7501b10738b156e\boinc_b7501b10738b156e.vbox" with version "1.16-windows"
00:00:10.802386          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_b94ccdd0f7018a05\boinc_b94ccdd0f7018a05.vbox" with version "1.16-windows"
00:00:10.909742          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_b88c5fb52318358b\boinc_b88c5fb52318358b.vbox" with version "1.16-windows"
00:00:10.950707          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_b7501b10738b156e\boinc_b7501b10738b156e.vbox" with version "1.16-windows"
00:00:11.065251          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:11.065438          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:11.074026          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:11.227097          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_b88c5fb52318358b\boinc_b88c5fb52318358b.vbox" with version "1.16-windows"
00:00:11.309613          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_b7501b10738b156e\boinc_b7501b10738b156e.vbox" with version "1.16-windows"
00:00:11.461093          Launched VM: 66720064 pid: 16476 (0x405c) frontend: headless name: boinc_b94ccdd0f7018a05
00:00:11.741541          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:11.741780          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:11.752016          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:11.796923          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:11.797210          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:11.808432          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:11.929267          Launched VM: 66765136 pid: 292 (0x124) frontend: headless name: boinc_b88c5fb52318358b
00:00:12.234084          Launched VM: 66763072 pid: 15776 (0x3da0) frontend: headless name: boinc_b7501b10738b156e
00:00:16.117577          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_b94ccdd0f7018a05\boinc_b94ccdd0f7018a05.vbox" with version "1.16-windows"
00:00:16.588862          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_b88c5fb52318358b\boinc_b88c5fb52318358b.vbox" with version "1.16-windows"
00:00:16.779178          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_b7501b10738b156e\boinc_b7501b10738b156e.vbox" with version "1.16-windows"
00:00:17.078580          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:17.129511          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:17.429380          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_b94ccdd0f7018a05\boinc_b94ccdd0f7018a05.vbox" with version "1.16-windows"
00:00:17.434595          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:17.633561          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_b88c5fb52318358b\boinc_b88c5fb52318358b.vbox" with version "1.16-windows"
00:00:17.898424          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_b7501b10738b156e\boinc_b7501b10738b156e.vbox" with version "1.16-windows"
00:00:18.034857          Saving settings file "C:\Users\User\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:18.095934          Saving settings file "C:\Users\User\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:18.420694          Saving settings file "C:\Users\User\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:23.641957 main     VirtualBox: object deletion starts
00:00:23.643469 main     HostDnsMonitor: shutting down ...
00:00:23.643608 main     HostDnsMonitor: shut down
00:00:23.649252 Watcher  ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0
00:00:23.649574 main     VirtualBox: object deleted

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

aximum PIIX3 SATA Controllers:  1
Maximum ICH9 SATA Controllers:   8
Maximum SATA Port count:         30
Maximum Devices per SATA Port:   1
Maximum PIIX3 SCSI Controllers:  1
Maximum ICH9 SCSI Controllers:   8
Maximum SCSI Port count:         16
Maximum Devices per SCSI Port:   1
Maximum SAS PIIX3 Controllers:   1
Maximum SAS ICH9 Controllers:    8
Maximum SAS Port count:          255
Maximum Devices per SAS Port:    1
Maximum NVMe PIIX3 Controllers:  1
Maximum NVMe ICH9 Controllers:   8
Maximum NVMe Port count:         255
Maximum Devices per NVMe Port:   1
Maximum virtio-scsi PIIX3 Controllers:  1
Maximum virtio-scsi ICH9 Controllers:   8
Maximum virtio-scsi Port count:         256
Maximum Devices per virtio-scsi Port:   1
Maximum PIIX3 Floppy Controllers:1
Maximum ICH9 Floppy Controllers: 1
Maximum Floppy Port count:       1
Maximum Devices per Floppy Port: 2
Default machine folder:          C:\Users\User\VirtualBox VMs
Raw-mode Supported:              no
Exclusive HW virtualization use: off
Default hard disk format:        VDI
VRDE auth library:               VBoxAuth
Webservice auth. library:        VBoxAuth
Remote desktop ExtPack:          
Log history count:               3
Default frontend:                
Default audio driver:            DirectSound
Autostart database path:         
Default Guest Additions ISO:     C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso
Logging Level:                   all
Proxy Mode:                      System
Proxy URL:                       

2021-04-15 06:41:52 (15060): 
Command: VBoxManage -q list hostinfo 
Exit Code: 0
Output:
Host Information:

Host time: 2021-04-15T10:41:52.252000000Z
Processor online count: 4
Processor count: 4
Processor online core count: 2
Processor core count: 2
Processor supports HW virtualization: no
Processor supports PAE: yes
Processor supports long mode: yes
Processor supports nested paging: no
Processor supports unrestricted guest: no
Processor supports nested HW virtualization: no
Processor#0 speed: unknown
Processor#0 description: AMD A10 PRO-7800B R7, 12 Compute Cores 4C+8G
Processor#1 speed: unknown
Processor#1 description: AMD A10 PRO-7800B R7, 12 Compute Cores 4C+8G
Processor#2 speed: unknown
Processor#2 description: AMD A10 PRO-7800B R7, 12 Compute Cores 4C+8G
Processor#3 speed: unknown
Processor#3 description: AMD A10 PRO-7800B R7, 12 Compute Cores 4C+8G
Memory size: 12212 MByte
Memory available: 5533 MByte
Operating system: Windows 10
Operating system version: 10.0.19042

2021-04-15 06:41:54 (15060): 
Command: VBoxManage -q showvminfo "boinc_b94ccdd0f7018a05" --machinereadable 
Exit Code: -2135228415
Output:
VBoxManage.exe: error: Could not find a registered machine named 'boinc_b94ccdd0f7018a05'
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown
VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2715 of file VBoxManageInfo.cpp

2021-04-15 06:41:54 (15060): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\3/vm_image.vdi" 
Exit Code: -2135228412
Output:
VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\3\vm_image.vdi' (VERR_FILE_NOT_FOUND)
VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp

2021-04-15 06:41:55 (15060): 
Command: VBoxManage -q createvm --name "boinc_b94ccdd0f7018a05" --basefolder "C:\ProgramData\BOINC\slots\3" --ostype "Linux26_64" --register
Exit Code: 0
Output:
Virtual machine 'boinc_b94ccdd0f7018a05' is created and registered.
UUID: 0c23c30c-10e4-4d62-97fa-6d6dee864e7c
Settings file: 'C:\ProgramData\BOINC\slots\3\boinc_b94ccdd0f7018a05\boinc_b94ccdd0f7018a05.vbox'

2021-04-15 06:41:56 (15060): 
Command: VBoxManage -q modifyvm "boinc_b94ccdd0f7018a05" --description "08282845_19_0" 
Exit Code: 0
Output:

2021-04-15 06:41:56 (15060): 
Command: VBoxManage -q modifyvm "boinc_b94ccdd0f7018a05" --memory 3072 
Exit Code: 0
Output:

2021-04-15 06:41:56 (15060): 
Command: VBoxManage -q modifyvm "boinc_b94ccdd0f7018a05" --cpus 1 
Exit Code: 0
Output:

2021-04-15 06:41:57 (15060): 
Command: VBoxManage -q modifyvm "boinc_b94ccdd0f7018a05" --acpi on --ioapic on 
Exit Code: 0
Output:

2021-04-15 06:41:57 (15060): 
Command: VBoxManage -q modifyvm "boinc_b94ccdd0f7018a05" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2021-04-15 06:41:57 (15060): 
Command: VBoxManage -q modifyvm "boinc_b94ccdd0f7018a05" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2021-04-15 06:41:58 (15060): 
Command: VBoxManage -q modifyvm "boinc_b94ccdd0f7018a05" --cableconnected1 on 
Exit Code: 0
Output:

2021-04-15 06:41:58 (15060): 
Command: VBoxManage -q modifyvm "boinc_b94ccdd0f7018a05" --usb off 
Exit Code: 0
Output:

2021-04-15 06:41:58 (15060): 
Command: VBoxManage -q modifyvm "boinc_b94ccdd0f7018a05" --uart1 off --uart2 off 
Exit Code: 0
Output:

2021-04-15 06:41:59 (15060): 
Command: VBoxManage -q modifyvm "boinc_b94ccdd0f7018a05" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2021-04-15 06:41:59 (15060): 
Command: VBoxManage -q modifyvm "boinc_b94ccdd0f7018a05" --audio none 
Exit Code: 0
Output:

2021-04-15 06:41:59 (15060): 
Command: VBoxManage -q modifyvm "boinc_b94ccdd0f7018a05" --clipboard disabled 
Exit Code: 0
Output:

2021-04-15 06:41:59 (15060): 
Command: VBoxManage -q modifyvm "boinc_b94ccdd0f7018a05" --draganddrop disabled 
Exit Code: 0
Output:

2021-04-15 06:42:00 (15060): 
Command: VBoxManage -q storagectl "boinc_b94ccdd0f7018a05" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2021-04-15 06:42:00 (15060): 
Command: VBoxManage -q storageattach "boinc_b94ccdd0f7018a05" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\ProgramData\BOINC\slots\3/vm_isocontext.iso" 
Exit Code: 0
Output:

2021-04-15 06:42:00 (15060): 
Command: VBoxManage -q storageattach "boinc_b94ccdd0f7018a05" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2021-04-15 06:42:01 (15060): 
Command: VBoxManage -q bandwidthctl "boinc_b94ccdd0f7018a05" add "boinc_b94ccdd0f7018a05_net" --type network --limit 1024G 
Exit Code: 0
Output:

2021-04-15 06:42:01 (15060): 
Command: VBoxManage -q sharedfolder add "boinc_b94ccdd0f7018a05" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\3/shared"
Exit Code: 0
Output:

2021-04-15 06:42:07 (15060): 
Command: VBoxManage -q startvm "boinc_b94ccdd0f7018a05" --type headless
Exit Code: -2147467259
Output:
Waiting for VM "boinc_b94ccdd0f7018a05" to power on...
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: AMD-V is disabled in the BIOS (or by the host OS) (VERR_SVM_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole

2021-04-15 06:42:07 (15060): 
Command: VBoxManage -q snapshot "boinc_b94ccdd0f7018a05" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2021-04-15 06:42:08 (15060): 
Command: VBoxManage -q bandwidthctl "boinc_b94ccdd0f7018a05" remove "boinc_b94ccdd0f7018a05_net" 
Exit Code: 0
Output:

2021-04-15 06:42:08 (15060): 
Command: VBoxManage -q unregistervm "boinc_b94ccdd0f7018a05" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

2021-04-15 06:42:09 (15060): 
Command: VBoxManage -q closemedium dvd "C:\ProgramData\BOINC\slots\3/vm_isocontext.iso" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

06:42:21 (15060): called boinc_finish(-2147467259)

</stderr_txt>
]]>


©2024 COPYRIGHT 2017-2018 NCN