Name | 08282845_51_0 |
Workunit | 7978502 |
Created | 15 Apr 2021, 7:43:45 UTC |
Sent | 15 Apr 2021, 10:02:27 UTC |
Report deadline | 20 Apr 2021, 10:02:27 UTC |
Received | 16 Apr 2021, 3:04:29 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | -2147467259 (0x80004005) Unknown error code |
Computer ID | 9552 |
Run time | 27 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 3.18 GFLOPS |
Application version | boinc2docker v1.14 (vbox64_mt) windows_x86_64 |
Peak working set size | 10.92 MB |
Peak swap size | 6.24 MB |
Peak disk usage | 278.17 MB |
<core_client_version>7.16.11</core_client_version> <![CDATA[ <message> Unspecified error (0x80004005) - exit code 2147500037 (0x80004005)</message> <stderr_txt> 2021-04-15 06:46:48 (7344): Detected: vboxwrapper 26202 2021-04-15 06:46:52 (7344): Detected: BOINC client v7.16.11 2021-04-15 06:46:52 (7344): Detected: VirtualBox VboxManage Interface (Version: 6.1.18) 2021-04-15 06:46:54 (7344): Create VM. (boinc_5d371361ad740e79, slot#3) 2021-04-15 06:46:54 (7344): Updating drive controller type and model for desired configuration. 2021-04-15 06:46:54 (7344): Setting Memory Size for VM. (3072MB) 2021-04-15 06:46:55 (7344): Setting CPU Count for VM. (1) 2021-04-15 06:46:55 (7344): Setting Chipset Options for VM. 2021-04-15 06:46:55 (7344): Setting Boot Options for VM. 2021-04-15 06:46:56 (7344): Setting Network Configuration for NAT. 2021-04-15 06:46:56 (7344): Enabling VM Network Access. 2021-04-15 06:46:56 (7344): Disabling USB Support for VM. 2021-04-15 06:46:56 (7344): Disabling COM Port Support for VM. 2021-04-15 06:46:57 (7344): Disabling LPT Port Support for VM. 2021-04-15 06:46:57 (7344): Disabling Audio Support for VM. 2021-04-15 06:46:57 (7344): Disabling Clipboard Support for VM. 2021-04-15 06:46:58 (7344): Disabling Drag and Drop Support for VM. 2021-04-15 06:46:58 (7344): Adding storage controller(s) to VM. 2021-04-15 06:46:58 (7344): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso) 2021-04-15 06:46:59 (7344): Adding VirtualBox Guest Additions to VM. 2021-04-15 06:46:59 (7344): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2021-04-15 06:46:59 (7344): Enabling shared directory for VM. 2021-04-15 06:47:00 (7344): Starting VM using VBoxManage interface. (boinc_5d371361ad740e79, slot#3) 2021-04-15 06:47:05 (7344): Error in start VM for VM: -2147467259 Command: VBoxManage -q startvm "boinc_5d371361ad740e79" --type headless Output: Waiting for VM "boinc_5d371361ad740e79" to power on... VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: AMD-V is disabled in the BIOS (or by the host OS) (VERR_SVM_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2021-04-15 06:47:05 (7344): VM failed to start. 2021-04-15 06:47:05 (7344): Could not start 2021-04-15 06:47:05 (7344): ERROR: VM failed to start 2021-04-15 06:47:05 (7344): Powering off VM. 2021-04-15 06:47:05 (7344): Deregistering VM. (boinc_5d371361ad740e79, slot#3) 2021-04-15 06:47:06 (7344): Removing network bandwidth throttle group from VM. 2021-04-15 06:47:06 (7344): Removing VM from VirtualBox. 2021-04-15 06:47:06 (7344): Removing virtual ISO 9660 disk from VirtualBox. Hypervisor System Log: 00:00:19.288370 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_4e10a964da61dfc4\boinc_4e10a964da61dfc4.vbox" with version "1.16-windows" 00:00:19.398292 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:19.398529 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:19.409822 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:19.470281 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_5d371361ad740e79\boinc_5d371361ad740e79.vbox" with version "1.16-windows" 00:00:19.572863 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_4e10a964da61dfc4\boinc_4e10a964da61dfc4.vbox" with version "1.16-windows" 00:00:19.693092 Launched VM: 61845536 pid: 6868 (0x1ad4) frontend: headless name: boinc_43e7df6ed4ed1656 00:00:19.801496 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_5d371361ad740e79\boinc_5d371361ad740e79.vbox" with version "1.16-windows" 00:00:19.902127 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_4e10a964da61dfc4\boinc_4e10a964da61dfc4.vbox" with version "1.16-windows" 00:00:20.043868 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_5d371361ad740e79\boinc_5d371361ad740e79.vbox" with version "1.16-windows" 00:00:20.159542 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:20.159888 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:20.180116 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:20.325137 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_5d371361ad740e79\boinc_5d371361ad740e79.vbox" with version "1.16-windows" 00:00:20.442878 Launched VM: 62112672 pid: 11380 (0x2c74) frontend: headless name: boinc_4e10a964da61dfc4 00:00:20.751037 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_5d371361ad740e79\boinc_5d371361ad740e79.vbox" with version "1.16-windows" 00:00:21.046022 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:21.053497 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:21.053726 Saving settings file "C:\Users\User\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:21.091438 Saving settings file "C:\Users\User\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:21.119300 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_5d371361ad740e79\boinc_5d371361ad740e79.vbox" with version "1.16-windows" 00:00:21.527806 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:21.528256 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:21.528790 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_5d371361ad740e79\boinc_5d371361ad740e79.vbox" with version "1.16-windows" 00:00:21.901078 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_5d371361ad740e79\boinc_5d371361ad740e79.vbox" with version "1.16-windows" 00:00:22.427077 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_5d371361ad740e79\boinc_5d371361ad740e79.vbox" with version "1.16-windows" 00:00:22.949284 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:22.949496 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:23.008720 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:23.898873 Launched VM: 62022416 pid: 14404 (0x3844) frontend: headless name: boinc_5d371361ad740e79 00:00:23.943846 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_43e7df6ed4ed1656\boinc_43e7df6ed4ed1656.vbox" with version "1.16-windows" 00:00:24.262510 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:24.487429 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_43e7df6ed4ed1656\boinc_43e7df6ed4ed1656.vbox" with version "1.16-windows" 00:00:24.759480 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_4e10a964da61dfc4\boinc_4e10a964da61dfc4.vbox" with version "1.16-windows" 00:00:24.945017 Saving settings file "C:\Users\User\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:24.993163 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:25.394465 Saving settings file "C:\Users\User\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:27.994939 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_5d371361ad740e79\boinc_5d371361ad740e79.vbox" with version "1.16-windows" 00:00:28.147204 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:28.543871 Saving settings file "C:\Users\User\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:33.837347 main VirtualBox: object deletion starts 00:00:33.838233 main HostDnsMonitor: shutting down ... 00:00:33.838279 main HostDnsMonitor: shut down 00:00:33.841205 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:33.841487 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: trollers: 8 Maximum SATA Port count: 30 Maximum Devices per SATA Port: 1 Maximum PIIX3 SCSI Controllers: 1 Maximum ICH9 SCSI Controllers: 8 Maximum SCSI Port count: 16 Maximum Devices per SCSI Port: 1 Maximum SAS PIIX3 Controllers: 1 Maximum SAS ICH9 Controllers: 8 Maximum SAS Port count: 255 Maximum Devices per SAS Port: 1 Maximum NVMe PIIX3 Controllers: 1 Maximum NVMe ICH9 Controllers: 8 Maximum NVMe Port count: 255 Maximum Devices per NVMe Port: 1 Maximum virtio-scsi PIIX3 Controllers: 1 Maximum virtio-scsi ICH9 Controllers: 8 Maximum virtio-scsi Port count: 256 Maximum Devices per virtio-scsi Port: 1 Maximum PIIX3 Floppy Controllers:1 Maximum ICH9 Floppy Controllers: 1 Maximum Floppy Port count: 1 Maximum Devices per Floppy Port: 2 Default machine folder: C:\Users\User\VirtualBox VMs Raw-mode Supported: no Exclusive HW virtualization use: off Default hard disk format: VDI VRDE auth library: VBoxAuth Webservice auth. library: VBoxAuth Remote desktop ExtPack: Log history count: 3 Default frontend: Default audio driver: DirectSound Autostart database path: Default Guest Additions ISO: C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso Logging Level: all Proxy Mode: System Proxy URL: 2021-04-15 06:46:53 (7344): Command: VBoxManage -q list hostinfo Exit Code: 0 Output: Host Information: Host time: 2021-04-15T10:46:52.859000000Z Processor online count: 4 Processor count: 4 Processor online core count: 2 Processor core count: 2 Processor supports HW virtualization: no Processor supports PAE: yes Processor supports long mode: yes Processor supports nested paging: no Processor supports unrestricted guest: no Processor supports nested HW virtualization: no Processor#0 speed: unknown Processor#0 description: AMD A10 PRO-7800B R7, 12 Compute Cores 4C+8G Processor#1 speed: unknown Processor#1 description: AMD A10 PRO-7800B R7, 12 Compute Cores 4C+8G Processor#2 speed: unknown Processor#2 description: AMD A10 PRO-7800B R7, 12 Compute Cores 4C+8G Processor#3 speed: unknown Processor#3 description: AMD A10 PRO-7800B R7, 12 Compute Cores 4C+8G Memory size: 12212 MByte Memory available: 5549 MByte Operating system: Windows 10 Operating system version: 10.0.19042 2021-04-15 06:46:54 (7344): Command: VBoxManage -q showvminfo "boinc_5d371361ad740e79" --machinereadable Exit Code: -2135228415 Output: VBoxManage.exe: error: Could not find a registered machine named 'boinc_5d371361ad740e79' VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2715 of file VBoxManageInfo.cpp 2021-04-15 06:46:54 (7344): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\3/vm_image.vdi" Exit Code: -2135228412 Output: VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\3\vm_image.vdi' (VERR_FILE_NOT_FOUND) VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp 2021-04-15 06:46:54 (7344): Command: VBoxManage -q createvm --name "boinc_5d371361ad740e79" --basefolder "C:\ProgramData\BOINC\slots\3" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_5d371361ad740e79' is created and registered. UUID: d3d761f9-b57b-4b0a-a966-8b85b85c1c4a Settings file: 'C:\ProgramData\BOINC\slots\3\boinc_5d371361ad740e79\boinc_5d371361ad740e79.vbox' 2021-04-15 06:46:54 (7344): Command: VBoxManage -q modifyvm "boinc_5d371361ad740e79" --description "08282845_51_0" Exit Code: 0 Output: 2021-04-15 06:46:55 (7344): Command: VBoxManage -q modifyvm "boinc_5d371361ad740e79" --memory 3072 Exit Code: 0 Output: 2021-04-15 06:46:55 (7344): Command: VBoxManage -q modifyvm "boinc_5d371361ad740e79" --cpus 1 Exit Code: 0 Output: 2021-04-15 06:46:55 (7344): Command: VBoxManage -q modifyvm "boinc_5d371361ad740e79" --acpi on --ioapic on Exit Code: 0 Output: 2021-04-15 06:46:56 (7344): Command: VBoxManage -q modifyvm "boinc_5d371361ad740e79" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2021-04-15 06:46:56 (7344): Command: VBoxManage -q modifyvm "boinc_5d371361ad740e79" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2021-04-15 06:46:56 (7344): Command: VBoxManage -q modifyvm "boinc_5d371361ad740e79" --cableconnected1 on Exit Code: 0 Output: 2021-04-15 06:46:56 (7344): Command: VBoxManage -q modifyvm "boinc_5d371361ad740e79" --usb off Exit Code: 0 Output: 2021-04-15 06:46:57 (7344): Command: VBoxManage -q modifyvm "boinc_5d371361ad740e79" --uart1 off --uart2 off Exit Code: 0 Output: 2021-04-15 06:46:57 (7344): Command: VBoxManage -q modifyvm "boinc_5d371361ad740e79" --lpt1 off --lpt2 off Exit Code: 0 Output: 2021-04-15 06:46:57 (7344): Command: VBoxManage -q modifyvm "boinc_5d371361ad740e79" --audio none Exit Code: 0 Output: 2021-04-15 06:46:58 (7344): Command: VBoxManage -q modifyvm "boinc_5d371361ad740e79" --clipboard disabled Exit Code: 0 Output: 2021-04-15 06:46:58 (7344): Command: VBoxManage -q modifyvm "boinc_5d371361ad740e79" --draganddrop disabled Exit Code: 0 Output: 2021-04-15 06:46:58 (7344): Command: VBoxManage -q storagectl "boinc_5d371361ad740e79" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2021-04-15 06:46:59 (7344): Command: VBoxManage -q storageattach "boinc_5d371361ad740e79" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\ProgramData\BOINC\slots\3/vm_isocontext.iso" Exit Code: 0 Output: 2021-04-15 06:46:59 (7344): Command: VBoxManage -q storageattach "boinc_5d371361ad740e79" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2021-04-15 06:46:59 (7344): Command: VBoxManage -q bandwidthctl "boinc_5d371361ad740e79" add "boinc_5d371361ad740e79_net" --type network --limit 1024G Exit Code: 0 Output: 2021-04-15 06:47:00 (7344): Command: VBoxManage -q sharedfolder add "boinc_5d371361ad740e79" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\3/shared" Exit Code: 0 Output: 2021-04-15 06:47:05 (7344): Command: VBoxManage -q startvm "boinc_5d371361ad740e79" --type headless Exit Code: -2147467259 Output: Waiting for VM "boinc_5d371361ad740e79" to power on... VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: AMD-V is disabled in the BIOS (or by the host OS) (VERR_SVM_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2021-04-15 06:47:06 (7344): Command: VBoxManage -q snapshot "boinc_5d371361ad740e79" list Exit Code: -108 Output: This machine does not have any snapshots 2021-04-15 06:47:06 (7344): Command: VBoxManage -q bandwidthctl "boinc_5d371361ad740e79" remove "boinc_5d371361ad740e79_net" Exit Code: 0 Output: VBoxManage.exe: error: Bandwidth groups cannot be deleted while the VM is running 2021-04-15 06:47:06 (7344): Command: VBoxManage -q unregistervm "boinc_5d371361ad740e79" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 2021-04-15 06:47:06 (7344): Command: VBoxManage -q closemedium dvd "C:\ProgramData\BOINC\slots\3/vm_isocontext.iso" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 06:47:12 (7344): called boinc_finish(-2147467259) </stderr_txt> ]]>
©2025 COPYRIGHT 2017-2018 NCN