Task 10196651

Name 08283636_02_0
Workunit 7994981
Created 15 Apr 2021, 16:43:14 UTC
Sent 15 Apr 2021, 19:12:51 UTC
Report deadline 20 Apr 2021, 19:12:51 UTC
Received 15 Apr 2021, 23:08:50 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status -2147467259 (0x80004005) Unknown error code
Computer ID 11308
Run time 17 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 1.00 GFLOPS
Application version boinc2docker v1.14 (vbox64_mt)
windows_x86_64
Peak working set size 11.49 MB
Peak swap size 6.23 MB
Peak disk usage 600.50 MB

Stderr output

<core_client_version>7.16.11</core_client_version>
<![CDATA[
<message>
Unspecified error
 (0x80004005) - exit code 2147500037 (0x80004005)</message>
<stderr_txt>
2021-04-15 12:17:43 (2636): Detected: vboxwrapper 26202
2021-04-15 12:17:43 (2636): Detected: BOINC client v7.16.11
2021-04-15 12:17:44 (2636): Detected: VirtualBox VboxManage Interface (Version: 6.1.12)
2021-04-15 12:17:44 (2636): Create VM. (boinc_7a952d0756a79e18, slot#0)
2021-04-15 12:17:44 (2636): Updating drive controller type and model for desired configuration.
2021-04-15 12:17:45 (2636): Setting Memory Size for VM. (3072MB)
2021-04-15 12:17:45 (2636): Setting CPU Count for VM. (1)
2021-04-15 12:17:45 (2636): Setting Chipset Options for VM.
2021-04-15 12:17:46 (2636): Setting Boot Options for VM.
2021-04-15 12:17:46 (2636): Setting Network Configuration for NAT.
2021-04-15 12:17:46 (2636): Enabling VM Network Access.
2021-04-15 12:17:47 (2636): Disabling USB Support for VM.
2021-04-15 12:17:47 (2636): Disabling COM Port Support for VM.
2021-04-15 12:17:47 (2636): Disabling LPT Port Support for VM.
2021-04-15 12:17:47 (2636): Disabling Audio Support for VM.
2021-04-15 12:17:48 (2636): Disabling Clipboard Support for VM.
2021-04-15 12:17:48 (2636): Disabling Drag and Drop Support for VM.
2021-04-15 12:17:48 (2636): Adding storage controller(s) to VM.
2021-04-15 12:17:48 (2636): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso)
2021-04-15 12:17:49 (2636): Adding VirtualBox Guest Additions to VM.
2021-04-15 12:17:49 (2636): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2021-04-15 12:17:49 (2636): Enabling shared directory for VM.
2021-04-15 12:17:50 (2636): Starting VM using VBoxManage interface. (boinc_7a952d0756a79e18, slot#0)
2021-04-15 12:17:52 (2636): Error in start VM for VM: -2147467259
Command:
VBoxManage -q startvm "boinc_7a952d0756a79e18" --type headless
Output:
Waiting for VM "boinc_7a952d0756a79e18" to power on...
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole

2021-04-15 12:17:52 (2636): VM failed to start.
2021-04-15 12:17:52 (2636): Could not start 
2021-04-15 12:17:52 (2636): ERROR: VM failed to start
2021-04-15 12:17:52 (2636): Powering off VM.
2021-04-15 12:17:52 (2636): Deregistering VM. (boinc_7a952d0756a79e18, slot#0)
2021-04-15 12:17:52 (2636): Removing network bandwidth throttle group from VM.
2021-04-15 12:17:52 (2636): Removing VM from VirtualBox.
2021-04-15 12:17:53 (2636): Removing virtual ISO 9660 disk from VirtualBox.

    Hypervisor System Log:

00:00:00.373870          HostDnsMonitor: initializing
00:00:00.380931          HostDnsMonitor: updating information
00:00:00.380981          HostDnsMonitor: old information
00:00:00.380982            no server entries
00:00:00.380983            no domain set
00:00:00.380984            no search string entries
00:00:00.380984          HostDnsMonitor: new information
00:00:00.380985            server 1: 68.105.28.11
00:00:00.380986            server 2: 68.105.29.11
00:00:00.380986            server 3: 68.105.28.12
00:00:00.380987            no domain set
00:00:00.380987            no search string entries
00:00:00.447938          SUPR0QueryVTCaps -> VERR_VMX_MSR_ALL_VMX_DISABLED
00:00:00.448451          VD: VDInit finished with VINF_SUCCESS
00:00:00.449479          VirtualBox: object created
00:00:00.955034          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={Could not find a registered machine named 'boinc_7a952d0756a79e18'}, preserve=false aResultDetail=0
00:00:01.219229          ERROR [COM]: aRC=VBOX_E_FILE_ERROR (0x80bb0004) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Could not find file for the medium 'C:\ProgramData\BOINC\slots\0\vm_image.vdi' (VERR_FILE_NOT_FOUND)}, preserve=false aResultDetail=-102
00:00:01.492884          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_7a952d0756a79e18\boinc_7a952d0756a79e18.vbox" with version "1.16-windows"
00:00:01.526803          Saving settings file "C:\Users\StarTop 3\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:01.759436          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_7a952d0756a79e18\boinc_7a952d0756a79e18.vbox" with version "1.16-windows"
00:00:02.021624          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_7a952d0756a79e18\boinc_7a952d0756a79e18.vbox" with version "1.16-windows"
00:00:02.287354          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_7a952d0756a79e18\boinc_7a952d0756a79e18.vbox" with version "1.16-windows"
00:00:02.553334          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_7a952d0756a79e18\boinc_7a952d0756a79e18.vbox" with version "1.16-windows"
00:00:02.822663          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_7a952d0756a79e18\boinc_7a952d0756a79e18.vbox" with version "1.16-windows"
00:00:03.084617          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_7a952d0756a79e18\boinc_7a952d0756a79e18.vbox" with version "1.16-windows"
00:00:03.350625          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_7a952d0756a79e18\boinc_7a952d0756a79e18.vbox" with version "1.16-windows"
00:00:03.634446          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_7a952d0756a79e18\boinc_7a952d0756a79e18.vbox" with version "1.16-windows"
00:00:03.880523          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_7a952d0756a79e18\boinc_7a952d0756a79e18.vbox" with version "1.16-windows"
00:00:04.147455          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_7a952d0756a79e18\boinc_7a952d0756a79e18.vbox" with version "1.16-windows"
00:00:04.412324          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_7a952d0756a79e18\boinc_7a952d0756a79e18.vbox" with version "1.16-windows"
00:00:04.680591          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_7a952d0756a79e18\boinc_7a952d0756a79e18.vbox" with version "1.16-windows"
00:00:04.944432          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_7a952d0756a79e18\boinc_7a952d0756a79e18.vbox" with version "1.16-windows"
00:00:05.209812          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_7a952d0756a79e18\boinc_7a952d0756a79e18.vbox" with version "1.16-windows"
00:00:05.474812          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:05.476256          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:05.476418          Saving settings file "C:\Users\StarTop 3\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:05.495692          Saving settings file "C:\Users\StarTop 3\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:05.512564          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_7a952d0756a79e18\boinc_7a952d0756a79e18.vbox" with version "1.16-windows"
00:00:05.743969          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:05.745174          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:05.745329          Saving settings file "C:\Users\StarTop 3\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:05.814023          Saving settings file "C:\Users\StarTop 3\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:05.839266          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_7a952d0756a79e18\boinc_7a952d0756a79e18.vbox" with version "1.16-windows"
00:00:06.005131          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_7a952d0756a79e18\boinc_7a952d0756a79e18.vbox" with version "1.16-windows"
00:00:06.269777          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_7a952d0756a79e18\boinc_7a952d0756a79e18.vbox" with version "1.16-windows"
00:00:06.540795          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.540944          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.549575          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:06.798336          Launched VM: 40166912 pid: 7584 (0x1da0) frontend: headless name: boinc_7a952d0756a79e18
00:00:09.106002          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_7a952d0756a79e18\boinc_7a952d0756a79e18.vbox" with version "1.16-windows"
00:00:09.238254          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:09.311334          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_7a952d0756a79e18\boinc_7a952d0756a79e18.vbox" with version "1.16-windows"
00:00:09.555912          Saving settings file "C:\Users\StarTop 3\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:14.834976 main     VirtualBox: object deletion starts
00:00:14.835526 main     HostDnsMonitor: shutting down ...
00:00:14.835610 main     HostDnsMonitor: shut down
00:00:14.837658 Watcher  ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0
00:00:14.837840 main     VirtualBox: object deleted

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

 Devices per IDE Port:    2
Maximum PIIX3 SATA Controllers:  1
Maximum ICH9 SATA Controllers:   8
Maximum SATA Port count:         30
Maximum Devices per SATA Port:   1
Maximum PIIX3 SCSI Controllers:  1
Maximum ICH9 SCSI Controllers:   8
Maximum SCSI Port count:         16
Maximum Devices per SCSI Port:   1
Maximum SAS PIIX3 Controllers:   1
Maximum SAS ICH9 Controllers:    8
Maximum SAS Port count:          255
Maximum Devices per SAS Port:    1
Maximum NVMe PIIX3 Controllers:  1
Maximum NVMe ICH9 Controllers:   8
Maximum NVMe Port count:         255
Maximum Devices per NVMe Port:   1
Maximum virtio-scsi PIIX3 Controllers:  1
Maximum virtio-scsi ICH9 Controllers:   8
Maximum virtio-scsi Port count:         256
Maximum Devices per virtio-scsi Port:   1
Maximum PIIX3 Floppy Controllers:1
Maximum ICH9 Floppy Controllers: 1
Maximum Floppy Port count:       1
Maximum Devices per Floppy Port: 2
Default machine folder:          C:\Users\StarTop 3\VirtualBox VMs
Raw-mode Supported:              no
Exclusive HW virtualization use: off
Default hard disk format:        VDI
VRDE auth library:               VBoxAuth
Webservice auth. library:        VBoxAuth
Remote desktop ExtPack:          
Log history count:               3
Default frontend:                
Default audio driver:            DirectSound
Autostart database path:         
Default Guest Additions ISO:     C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso
Logging Level:                   all
Proxy Mode:                      System
Proxy URL:                       

2021-04-15 12:17:44 (2636): 
Command: VBoxManage -q list hostinfo 
Exit Code: 0
Output:
Host Information:

Host time: 2021-04-15T19:17:44.139000000Z
Processor online count: 4
Processor count: 4
Processor online core count: 2
Processor core count: 2
Processor supports HW virtualization: no
Processor supports PAE: yes
Processor supports long mode: yes
Processor supports nested paging: no
Processor supports unrestricted guest: no
Processor supports nested HW virtualization: no
Processor#0 speed: unknown
Processor#0 description: Intel(R) Core(TM) i5-4200M CPU @ 2.50GHz
Processor#1 speed: unknown
Processor#1 description: Intel(R) Core(TM) i5-4200M CPU @ 2.50GHz
Processor#2 speed: unknown
Processor#2 description: Intel(R) Core(TM) i5-4200M CPU @ 2.50GHz
Processor#3 speed: unknown
Processor#3 description: Intel(R) Core(TM) i5-4200M CPU @ 2.50GHz
Memory size: 3810 MByte
Memory available: 1638 MByte
Operating system: Windows 10
Operating system version: 10.0.19042

2021-04-15 12:17:44 (2636): 
Command: VBoxManage -q showvminfo "boinc_7a952d0756a79e18" --machinereadable 
Exit Code: -2135228415
Output:
VBoxManage.exe: error: Could not find a registered machine named 'boinc_7a952d0756a79e18'
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown
VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2715 of file VBoxManageInfo.cpp

2021-04-15 12:17:44 (2636): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\0/vm_image.vdi" 
Exit Code: -2135228412
Output:
VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\0\vm_image.vdi' (VERR_FILE_NOT_FOUND)
VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp

2021-04-15 12:17:45 (2636): 
Command: VBoxManage -q createvm --name "boinc_7a952d0756a79e18" --basefolder "C:\ProgramData\BOINC\slots\0" --ostype "Linux26_64" --register
Exit Code: 0
Output:
Virtual machine 'boinc_7a952d0756a79e18' is created and registered.
UUID: 2858af32-1e84-4d70-b2e4-9126aa9cbbfe
Settings file: 'C:\ProgramData\BOINC\slots\0\boinc_7a952d0756a79e18\boinc_7a952d0756a79e18.vbox'

2021-04-15 12:17:45 (2636): 
Command: VBoxManage -q modifyvm "boinc_7a952d0756a79e18" --description "08283636_02_0" 
Exit Code: 0
Output:

2021-04-15 12:17:45 (2636): 
Command: VBoxManage -q modifyvm "boinc_7a952d0756a79e18" --memory 3072 
Exit Code: 0
Output:

2021-04-15 12:17:45 (2636): 
Command: VBoxManage -q modifyvm "boinc_7a952d0756a79e18" --cpus 1 
Exit Code: 0
Output:

2021-04-15 12:17:46 (2636): 
Command: VBoxManage -q modifyvm "boinc_7a952d0756a79e18" --acpi on --ioapic on 
Exit Code: 0
Output:

2021-04-15 12:17:46 (2636): 
Command: VBoxManage -q modifyvm "boinc_7a952d0756a79e18" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2021-04-15 12:17:46 (2636): 
Command: VBoxManage -q modifyvm "boinc_7a952d0756a79e18" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2021-04-15 12:17:47 (2636): 
Command: VBoxManage -q modifyvm "boinc_7a952d0756a79e18" --cableconnected1 on 
Exit Code: 0
Output:

2021-04-15 12:17:47 (2636): 
Command: VBoxManage -q modifyvm "boinc_7a952d0756a79e18" --usb off 
Exit Code: 0
Output:

2021-04-15 12:17:47 (2636): 
Command: VBoxManage -q modifyvm "boinc_7a952d0756a79e18" --uart1 off --uart2 off 
Exit Code: 0
Output:

2021-04-15 12:17:47 (2636): 
Command: VBoxManage -q modifyvm "boinc_7a952d0756a79e18" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2021-04-15 12:17:48 (2636): 
Command: VBoxManage -q modifyvm "boinc_7a952d0756a79e18" --audio none 
Exit Code: 0
Output:

2021-04-15 12:17:48 (2636): 
Command: VBoxManage -q modifyvm "boinc_7a952d0756a79e18" --clipboard disabled 
Exit Code: 0
Output:

2021-04-15 12:17:48 (2636): 
Command: VBoxManage -q modifyvm "boinc_7a952d0756a79e18" --draganddrop disabled 
Exit Code: 0
Output:

2021-04-15 12:17:48 (2636): 
Command: VBoxManage -q storagectl "boinc_7a952d0756a79e18" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2021-04-15 12:17:49 (2636): 
Command: VBoxManage -q storageattach "boinc_7a952d0756a79e18" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\ProgramData\BOINC\slots\0/vm_isocontext.iso" 
Exit Code: 0
Output:

2021-04-15 12:17:49 (2636): 
Command: VBoxManage -q storageattach "boinc_7a952d0756a79e18" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2021-04-15 12:17:49 (2636): 
Command: VBoxManage -q bandwidthctl "boinc_7a952d0756a79e18" add "boinc_7a952d0756a79e18_net" --type network --limit 1024G 
Exit Code: 0
Output:

2021-04-15 12:17:49 (2636): 
Command: VBoxManage -q sharedfolder add "boinc_7a952d0756a79e18" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\0/shared"
Exit Code: 0
Output:

2021-04-15 12:17:52 (2636): 
Command: VBoxManage -q startvm "boinc_7a952d0756a79e18" --type headless
Exit Code: -2147467259
Output:
Waiting for VM "boinc_7a952d0756a79e18" to power on...
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole

2021-04-15 12:17:52 (2636): 
Command: VBoxManage -q snapshot "boinc_7a952d0756a79e18" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2021-04-15 12:17:52 (2636): 
Command: VBoxManage -q bandwidthctl "boinc_7a952d0756a79e18" remove "boinc_7a952d0756a79e18_net" 
Exit Code: 0
Output:

2021-04-15 12:17:53 (2636): 
Command: VBoxManage -q unregistervm "boinc_7a952d0756a79e18" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

2021-04-15 12:17:53 (2636): 
Command: VBoxManage -q closemedium dvd "C:\ProgramData\BOINC\slots\0/vm_isocontext.iso" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

12:17:58 (2636): called boinc_finish(-2147467259)

</stderr_txt>
]]>


©2025 COPYRIGHT 2017-2018 NCN