Name | 08282713_09_1 |
Workunit | 7976431 |
Created | 15 Apr 2021, 22:05:09 UTC |
Sent | 15 Apr 2021, 22:18:38 UTC |
Report deadline | 20 Apr 2021, 22:18:38 UTC |
Received | 16 Apr 2021, 22:33:20 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | -2147467259 (0x80004005) Unknown error code |
Computer ID | 10216 |
Run time | 18 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 4.44 GFLOPS |
Application version | boinc2docker v1.14 (vbox64_mt) windows_x86_64 |
Peak working set size | 11.46 MB |
Peak swap size | 6.21 MB |
Peak disk usage | 498.95 MB |
<core_client_version>7.16.11</core_client_version> <![CDATA[ <message> Unspecified error (0x80004005) - exit code 2147500037 (0x80004005)</message> <stderr_txt> 2021-04-15 17:26:20 (3292): Detected: vboxwrapper 26202 2021-04-15 17:26:20 (3292): Detected: BOINC client v7.16.11 2021-04-15 17:26:21 (3292): Detected: VirtualBox VboxManage Interface (Version: 6.1.12) 2021-04-15 17:26:22 (3292): Create VM. (boinc_3b9f8370fe781234, slot#8) 2021-04-15 17:26:22 (3292): Updating drive controller type and model for desired configuration. 2021-04-15 17:26:22 (3292): Setting Memory Size for VM. (3072MB) 2021-04-15 17:26:22 (3292): Setting CPU Count for VM. (1) 2021-04-15 17:26:23 (3292): Setting Chipset Options for VM. 2021-04-15 17:26:23 (3292): Setting Boot Options for VM. 2021-04-15 17:26:23 (3292): Setting Network Configuration for NAT. 2021-04-15 17:26:23 (3292): Enabling VM Network Access. 2021-04-15 17:26:24 (3292): Disabling USB Support for VM. 2021-04-15 17:26:24 (3292): Disabling COM Port Support for VM. 2021-04-15 17:26:24 (3292): Disabling LPT Port Support for VM. 2021-04-15 17:26:25 (3292): Disabling Audio Support for VM. 2021-04-15 17:26:25 (3292): Disabling Clipboard Support for VM. 2021-04-15 17:26:25 (3292): Disabling Drag and Drop Support for VM. 2021-04-15 17:26:25 (3292): Adding storage controller(s) to VM. 2021-04-15 17:26:26 (3292): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso) 2021-04-15 17:26:26 (3292): Adding VirtualBox Guest Additions to VM. 2021-04-15 17:26:26 (3292): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2021-04-15 17:26:27 (3292): Enabling shared directory for VM. 2021-04-15 17:26:27 (3292): Starting VM using VBoxManage interface. (boinc_3b9f8370fe781234, slot#8) 2021-04-15 17:26:30 (3292): Error in start VM for VM: -2147467259 Command: VBoxManage -q startvm "boinc_3b9f8370fe781234" --type headless Output: Waiting for VM "boinc_3b9f8370fe781234" to power on... VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2021-04-15 17:26:30 (3292): VM failed to start. 2021-04-15 17:26:30 (3292): Could not start 2021-04-15 17:26:30 (3292): ERROR: VM failed to start 2021-04-15 17:26:30 (3292): Powering off VM. 2021-04-15 17:26:30 (3292): Deregistering VM. (boinc_3b9f8370fe781234, slot#8) 2021-04-15 17:26:30 (3292): Removing network bandwidth throttle group from VM. 2021-04-15 17:26:30 (3292): Removing VM from VirtualBox. 2021-04-15 17:26:31 (3292): Removing virtual ISO 9660 disk from VirtualBox. Hypervisor System Log: 00:00:00.253864 HostDnsMonitor: initializing 00:00:00.261598 HostDnsMonitor: updating information 00:00:00.261635 HostDnsMonitor: old information 00:00:00.261637 no server entries 00:00:00.261638 no domain set 00:00:00.261639 no search string entries 00:00:00.261639 HostDnsMonitor: new information 00:00:00.261640 server 1: 192.168.110.1 00:00:00.261641 domain: lan1 00:00:00.261641 no search string entries 00:00:00.343589 SUPR0QueryVTCaps -> VERR_VMX_MSR_ALL_VMX_DISABLED 00:00:00.344767 VD: VDInit finished with VINF_SUCCESS 00:00:00.346396 VirtualBox: object created 00:00:00.784802 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={Could not find a registered machine named 'boinc_3b9f8370fe781234'}, preserve=false aResultDetail=0 00:00:01.019938 ERROR [COM]: aRC=VBOX_E_FILE_ERROR (0x80bb0004) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Could not find file for the medium 'C:\ProgramData\BOINC\slots\8\vm_image.vdi' (VERR_FILE_NOT_FOUND)}, preserve=false aResultDetail=-102 00:00:01.291242 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_3b9f8370fe781234\boinc_3b9f8370fe781234.vbox" with version "1.16-windows" 00:00:01.297242 Saving settings file "C:\Users\Administrator.SANITATIONDESKT\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:01.567167 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_3b9f8370fe781234\boinc_3b9f8370fe781234.vbox" with version "1.16-windows" 00:00:01.870524 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_3b9f8370fe781234\boinc_3b9f8370fe781234.vbox" with version "1.16-windows" 00:00:02.147104 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_3b9f8370fe781234\boinc_3b9f8370fe781234.vbox" with version "1.16-windows" 00:00:02.413265 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_3b9f8370fe781234\boinc_3b9f8370fe781234.vbox" with version "1.16-windows" 00:00:02.668383 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_3b9f8370fe781234\boinc_3b9f8370fe781234.vbox" with version "1.16-windows" 00:00:02.941317 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_3b9f8370fe781234\boinc_3b9f8370fe781234.vbox" with version "1.16-windows" 00:00:03.213014 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_3b9f8370fe781234\boinc_3b9f8370fe781234.vbox" with version "1.16-windows" 00:00:03.511741 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_3b9f8370fe781234\boinc_3b9f8370fe781234.vbox" with version "1.16-windows" 00:00:03.793208 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_3b9f8370fe781234\boinc_3b9f8370fe781234.vbox" with version "1.16-windows" 00:00:04.051772 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_3b9f8370fe781234\boinc_3b9f8370fe781234.vbox" with version "1.16-windows" 00:00:04.323192 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_3b9f8370fe781234\boinc_3b9f8370fe781234.vbox" with version "1.16-windows" 00:00:04.585323 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_3b9f8370fe781234\boinc_3b9f8370fe781234.vbox" with version "1.16-windows" 00:00:04.873807 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_3b9f8370fe781234\boinc_3b9f8370fe781234.vbox" with version "1.16-windows" 00:00:05.147619 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_3b9f8370fe781234\boinc_3b9f8370fe781234.vbox" with version "1.16-windows" 00:00:05.473961 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:05.475658 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:05.475866 Saving settings file "C:\Users\Administrator.SANITATIONDESKT\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:05.478617 Saving settings file "C:\Users\Administrator.SANITATIONDESKT\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:05.481193 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_3b9f8370fe781234\boinc_3b9f8370fe781234.vbox" with version "1.16-windows" 00:00:05.717320 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:05.719022 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:05.719229 Saving settings file "C:\Users\Administrator.SANITATIONDESKT\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:05.721856 Saving settings file "C:\Users\Administrator.SANITATIONDESKT\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:05.724263 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_3b9f8370fe781234\boinc_3b9f8370fe781234.vbox" with version "1.16-windows" 00:00:06.011191 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_3b9f8370fe781234\boinc_3b9f8370fe781234.vbox" with version "1.16-windows" 00:00:06.288910 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_3b9f8370fe781234\boinc_3b9f8370fe781234.vbox" with version "1.16-windows" 00:00:06.573911 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:06.574168 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:06.582259 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:06.829732 Launched VM: 65800736 pid: 7988 (0x1f34) frontend: headless name: boinc_3b9f8370fe781234 00:00:09.609429 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_3b9f8370fe781234\boinc_3b9f8370fe781234.vbox" with version "1.16-windows" 00:00:09.692876 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:09.778384 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_3b9f8370fe781234\boinc_3b9f8370fe781234.vbox" with version "1.16-windows" 00:00:10.054742 Saving settings file "C:\Users\Administrator.SANITATIONDESKT\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:15.339807 main VirtualBox: object deletion starts 00:00:15.340402 main HostDnsMonitor: shutting down ... 00:00:15.340434 main HostDnsMonitor: shut down 00:00:15.341372 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:15.341555 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: aximum SAS Port count: 255 Maximum Devices per SAS Port: 1 Maximum NVMe PIIX3 Controllers: 1 Maximum NVMe ICH9 Controllers: 8 Maximum NVMe Port count: 255 Maximum Devices per NVMe Port: 1 Maximum virtio-scsi PIIX3 Controllers: 1 Maximum virtio-scsi ICH9 Controllers: 8 Maximum virtio-scsi Port count: 256 Maximum Devices per virtio-scsi Port: 1 Maximum PIIX3 Floppy Controllers:1 Maximum ICH9 Floppy Controllers: 1 Maximum Floppy Port count: 1 Maximum Devices per Floppy Port: 2 Default machine folder: C:\Users\Administrator.SANITATIONDESKT\VirtualBox VMs Raw-mode Supported: no Exclusive HW virtualization use: off Default hard disk format: VDI VRDE auth library: VBoxAuth Webservice auth. library: VBoxAuth Remote desktop ExtPack: Log history count: 3 Default frontend: Default audio driver: DirectSound Autostart database path: Default Guest Additions ISO: C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso Logging Level: all Proxy Mode: System Proxy URL: 2021-04-15 17:26:21 (3292): Command: VBoxManage -q list hostinfo Exit Code: 0 Output: Host Information: Host time: 2021-04-15T22:26:21.289000000Z Processor online count: 8 Processor count: 8 Processor online core count: 4 Processor core count: 4 Processor supports HW virtualization: no Processor supports PAE: yes Processor supports long mode: yes Processor supports nested paging: no Processor supports unrestricted guest: no Processor supports nested HW virtualization: no Processor#0 speed: unknown Processor#0 description: Intel(R) Core(TM) i7-7700 CPU @ 3.60GHz Processor#1 speed: unknown Processor#1 description: Intel(R) Core(TM) i7-7700 CPU @ 3.60GHz Processor#2 speed: unknown Processor#2 description: Intel(R) Core(TM) i7-7700 CPU @ 3.60GHz Processor#3 speed: unknown Processor#3 description: Intel(R) Core(TM) i7-7700 CPU @ 3.60GHz Processor#4 speed: unknown Processor#4 description: Intel(R) Core(TM) i7-7700 CPU @ 3.60GHz Processor#5 speed: unknown Processor#5 description: Intel(R) Core(TM) i7-7700 CPU @ 3.60GHz Processor#6 speed: unknown Processor#6 description: Intel(R) Core(TM) i7-7700 CPU @ 3.60GHz Processor#7 speed: unknown Processor#7 description: Intel(R) Core(TM) i7-7700 CPU @ 3.60GHz Memory size: 8098 MByte Memory available: 4040 MByte Operating system: Windows 10 Operating system version: 10.0.19041 2021-04-15 17:26:21 (3292): Command: VBoxManage -q showvminfo "boinc_3b9f8370fe781234" --machinereadable Exit Code: -2135228415 Output: VBoxManage.exe: error: Could not find a registered machine named 'boinc_3b9f8370fe781234' VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2715 of file VBoxManageInfo.cpp 2021-04-15 17:26:22 (3292): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\8/vm_image.vdi" Exit Code: -2135228412 Output: VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\8\vm_image.vdi' (VERR_FILE_NOT_FOUND) VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp 2021-04-15 17:26:22 (3292): Command: VBoxManage -q createvm --name "boinc_3b9f8370fe781234" --basefolder "C:\ProgramData\BOINC\slots\8" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_3b9f8370fe781234' is created and registered. UUID: 02768d58-fc12-4a35-880d-c4ee6d451150 Settings file: 'C:\ProgramData\BOINC\slots\8\boinc_3b9f8370fe781234\boinc_3b9f8370fe781234.vbox' 2021-04-15 17:26:22 (3292): Command: VBoxManage -q modifyvm "boinc_3b9f8370fe781234" --description "08282713_09_1" Exit Code: 0 Output: 2021-04-15 17:26:22 (3292): Command: VBoxManage -q modifyvm "boinc_3b9f8370fe781234" --memory 3072 Exit Code: 0 Output: 2021-04-15 17:26:23 (3292): Command: VBoxManage -q modifyvm "boinc_3b9f8370fe781234" --cpus 1 Exit Code: 0 Output: 2021-04-15 17:26:23 (3292): Command: VBoxManage -q modifyvm "boinc_3b9f8370fe781234" --acpi on --ioapic on Exit Code: 0 Output: 2021-04-15 17:26:23 (3292): Command: VBoxManage -q modifyvm "boinc_3b9f8370fe781234" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2021-04-15 17:26:23 (3292): Command: VBoxManage -q modifyvm "boinc_3b9f8370fe781234" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2021-04-15 17:26:24 (3292): Command: VBoxManage -q modifyvm "boinc_3b9f8370fe781234" --cableconnected1 on Exit Code: 0 Output: 2021-04-15 17:26:24 (3292): Command: VBoxManage -q modifyvm "boinc_3b9f8370fe781234" --usb off Exit Code: 0 Output: 2021-04-15 17:26:24 (3292): Command: VBoxManage -q modifyvm "boinc_3b9f8370fe781234" --uart1 off --uart2 off Exit Code: 0 Output: 2021-04-15 17:26:25 (3292): Command: VBoxManage -q modifyvm "boinc_3b9f8370fe781234" --lpt1 off --lpt2 off Exit Code: 0 Output: 2021-04-15 17:26:25 (3292): Command: VBoxManage -q modifyvm "boinc_3b9f8370fe781234" --audio none Exit Code: 0 Output: 2021-04-15 17:26:25 (3292): Command: VBoxManage -q modifyvm "boinc_3b9f8370fe781234" --clipboard disabled Exit Code: 0 Output: 2021-04-15 17:26:25 (3292): Command: VBoxManage -q modifyvm "boinc_3b9f8370fe781234" --draganddrop disabled Exit Code: 0 Output: 2021-04-15 17:26:26 (3292): Command: VBoxManage -q storagectl "boinc_3b9f8370fe781234" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2021-04-15 17:26:26 (3292): Command: VBoxManage -q storageattach "boinc_3b9f8370fe781234" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\ProgramData\BOINC\slots\8/vm_isocontext.iso" Exit Code: 0 Output: 2021-04-15 17:26:26 (3292): Command: VBoxManage -q storageattach "boinc_3b9f8370fe781234" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2021-04-15 17:26:27 (3292): Command: VBoxManage -q bandwidthctl "boinc_3b9f8370fe781234" add "boinc_3b9f8370fe781234_net" --type network --limit 1024G Exit Code: 0 Output: 2021-04-15 17:26:27 (3292): Command: VBoxManage -q sharedfolder add "boinc_3b9f8370fe781234" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\8/shared" Exit Code: 0 Output: 2021-04-15 17:26:30 (3292): Command: VBoxManage -q startvm "boinc_3b9f8370fe781234" --type headless Exit Code: -2147467259 Output: Waiting for VM "boinc_3b9f8370fe781234" to power on... VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2021-04-15 17:26:30 (3292): Command: VBoxManage -q snapshot "boinc_3b9f8370fe781234" list Exit Code: -108 Output: This machine does not have any snapshots 2021-04-15 17:26:30 (3292): Command: VBoxManage -q bandwidthctl "boinc_3b9f8370fe781234" remove "boinc_3b9f8370fe781234_net" Exit Code: 0 Output: 2021-04-15 17:26:31 (3292): Command: VBoxManage -q unregistervm "boinc_3b9f8370fe781234" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 2021-04-15 17:26:31 (3292): Command: VBoxManage -q closemedium dvd "C:\ProgramData\BOINC\slots\8/vm_isocontext.iso" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 17:26:36 (3292): called boinc_finish(-2147467259) </stderr_txt> ]]>
©2025 COPYRIGHT 2017-2018 NCN