Task 10214208

Name 08280632_07_2
Workunit 7938014
Created 16 Apr 2021, 0:58:25 UTC
Sent 16 Apr 2021, 1:02:50 UTC
Report deadline 21 Apr 2021, 1:02:50 UTC
Received 17 Apr 2021, 1:27:44 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status 1 (0x00000001) Unknown error code
Computer ID 8974
Run time 18 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 4.18 GFLOPS
Application version boinc2docker v1.14 (vbox64_mt)
windows_x86_64
Peak working set size 7.69 MB
Peak swap size 2.56 MB
Peak disk usage 239.33 MB

Stderr output

<core_client_version>7.16.11</core_client_version>
<![CDATA[
<message>
Incorrect function.
 (0x1) - exit code 1 (0x1)</message>
<stderr_txt>
2021-04-16 02:27:11 (1408): Detected: vboxwrapper 26202
2021-04-16 02:27:11 (1408): Detected: BOINC client v7.16.11
2021-04-16 02:27:12 (1408): Detected: VirtualBox VboxManage Interface (Version: 6.1.12)
2021-04-16 02:27:13 (1408): Create VM. (boinc_ef3d5802bf012a72, slot#8)
2021-04-16 02:27:13 (1408): Updating drive controller type and model for desired configuration.
2021-04-16 02:27:13 (1408): Setting Memory Size for VM. (3072MB)
2021-04-16 02:27:14 (1408): Setting CPU Count for VM. (1)
2021-04-16 02:27:14 (1408): Setting Chipset Options for VM.
2021-04-16 02:27:14 (1408): Setting Boot Options for VM.
2021-04-16 02:27:15 (1408): Setting Network Configuration for NAT.
2021-04-16 02:27:15 (1408): Enabling VM Network Access.
2021-04-16 02:27:15 (1408): Disabling USB Support for VM.
2021-04-16 02:27:15 (1408): Disabling COM Port Support for VM.
2021-04-16 02:27:16 (1408): Disabling LPT Port Support for VM.
2021-04-16 02:27:16 (1408): Disabling Audio Support for VM.
2021-04-16 02:27:16 (1408): Disabling Clipboard Support for VM.
2021-04-16 02:27:17 (1408): Disabling Drag and Drop Support for VM.
2021-04-16 02:27:17 (1408): Adding storage controller(s) to VM.
2021-04-16 02:27:17 (1408): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso)
2021-04-16 02:27:17 (1408): Adding VirtualBox Guest Additions to VM.
2021-04-16 02:27:18 (1408): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2021-04-16 02:27:18 (1408): Enabling shared directory for VM.
2021-04-16 02:27:18 (1408): Starting VM using VBoxManage interface. (boinc_ef3d5802bf012a72, slot#8)
2021-04-16 02:27:20 (1408): Error in start VM for VM: 1
Command:
VBoxManage -q startvm "boinc_ef3d5802bf012a72" --type headless
Output:
Waiting for VM "boinc_ef3d5802bf012a72" to power on...
VBoxManage.exe: error: The virtual machine 'boinc_ef3d5802bf012a72' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\8\boinc_ef3d5802bf012a72\Logs\VBoxHardening.log'
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine

2021-04-16 02:27:20 (1408): VM failed to start.
2021-04-16 02:27:20 (1408): Could not start 
2021-04-16 02:27:20 (1408): ERROR: VM failed to start
2021-04-16 02:27:20 (1408): Powering off VM.
2021-04-16 02:27:20 (1408): Deregistering VM. (boinc_ef3d5802bf012a72, slot#8)
2021-04-16 02:27:20 (1408): Removing network bandwidth throttle group from VM.
2021-04-16 02:27:21 (1408): Removing VM from VirtualBox.
2021-04-16 02:27:21 (1408): Removing virtual ISO 9660 disk from VirtualBox.

    Hypervisor System Log:

00:00:05.963105          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:05.963386          Saving settings file "C:\Users\terry\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:05.976314          Saving settings file "C:\Users\terry\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:05.989777          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_dc1b8cbad6cb793f\boinc_dc1b8cbad6cb793f.vbox" with version "1.16-windows"
00:00:06.080721          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.086103          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.086324          Saving settings file "C:\Users\terry\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:06.098809          Saving settings file "C:\Users\terry\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:06.111724          Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_ef3d5802bf012a72\boinc_ef3d5802bf012a72.vbox" with version "1.16-windows"
00:00:06.233449          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.239583          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.239841          Saving settings file "C:\Users\terry\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:06.250180          Saving settings file "C:\Users\terry\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:06.260801          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_dc1b8cbad6cb793f\boinc_dc1b8cbad6cb793f.vbox" with version "1.16-windows"
00:00:06.355572          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.356220          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.356860          Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_ef3d5802bf012a72\boinc_ef3d5802bf012a72.vbox" with version "1.16-windows"
00:00:06.514660          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_dc1b8cbad6cb793f\boinc_dc1b8cbad6cb793f.vbox" with version "1.16-windows"
00:00:06.638004          Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_ef3d5802bf012a72\boinc_ef3d5802bf012a72.vbox" with version "1.16-windows"
00:00:06.809033          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_dc1b8cbad6cb793f\boinc_dc1b8cbad6cb793f.vbox" with version "1.16-windows"
00:00:06.911651          Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_ef3d5802bf012a72\boinc_ef3d5802bf012a72.vbox" with version "1.16-windows"
00:00:07.083641          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.083895          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.095447          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:07.198017          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.198279          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.207719          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:07.369087          Launched VM: 68049760 pid: 24048 (0x5df0) frontend: headless name: boinc_dc1b8cbad6cb793f
00:00:07.500901          Launched VM: 67952640 pid: 8080 (0x1f90) frontend: headless name: boinc_ef3d5802bf012a72
00:00:08.880811 Watcher  ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={The virtual machine 'boinc_dc1b8cbad6cb793f' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\3\boinc_dc1b8cbad6cb793f\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0
00:00:08.881737 Watcher  Reaper: Pid 24048 (5df0) exited normally: 1 (0x1)
00:00:09.026712 Watcher  ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={The virtual machine 'boinc_ef3d5802bf012a72' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\8\boinc_ef3d5802bf012a72\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0
00:00:09.027207 Watcher  Reaper: Pid 8080 (1f90) exited normally: 1 (0x1)
00:00:09.044109          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:09.187250          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_dc1b8cbad6cb793f\boinc_dc1b8cbad6cb793f.vbox" with version "1.16-windows"
00:00:09.202147          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:09.350439          Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_ef3d5802bf012a72\boinc_ef3d5802bf012a72.vbox" with version "1.16-windows"
00:00:09.449126          Saving settings file "C:\Users\terry\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:09.633570          Saving settings file "C:\Users\terry\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:14.923283 main     VirtualBox: object deletion starts
00:00:14.924118 main     HostDnsMonitor: shutting down ...
00:00:14.924218 main     HostDnsMonitor: shut down
00:00:14.926807 Watcher  ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0
00:00:14.927155 main     VirtualBox: object deleted

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

 library:        VBoxAuth
Remote desktop ExtPack:          
Log history count:               3
Default frontend:                
Default audio driver:            DirectSound
Autostart database path:         
Default Guest Additions ISO:     C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso
Logging Level:                   all
Proxy Mode:                      System
Proxy URL:                       

2021-04-16 02:27:12 (1408): 
Command: VBoxManage -q list hostinfo 
Exit Code: 0
Output:
Host Information:

Host time: 2021-04-16T01:27:12.664000000Z
Processor online count: 16
Processor count: 16
Processor online core count: 8
Processor core count: 8
Processor supports HW virtualization: no
Processor supports PAE: yes
Processor supports long mode: yes
Processor supports nested paging: no
Processor supports unrestricted guest: no
Processor supports nested HW virtualization: no
Processor#0 speed: unknown
Processor#0 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#1 speed: unknown
Processor#1 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#2 speed: unknown
Processor#2 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#3 speed: unknown
Processor#3 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#4 speed: unknown
Processor#4 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#5 speed: unknown
Processor#5 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#6 speed: unknown
Processor#6 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#7 speed: unknown
Processor#7 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#8 speed: unknown
Processor#8 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#9 speed: unknown
Processor#9 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#10 speed: unknown
Processor#10 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#11 speed: unknown
Processor#11 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#12 speed: unknown
Processor#12 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#13 speed: unknown
Processor#13 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#14 speed: unknown
Processor#14 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#15 speed: unknown
Processor#15 description: AMD Ryzen 7 1800X Eight-Core Processor
Memory size: 16313 MByte
Memory available: 6409 MByte
Operating system: Windows 10
Operating system version: 10.0.19041

2021-04-16 02:27:13 (1408): 
Command: VBoxManage -q showvminfo "boinc_ef3d5802bf012a72" --machinereadable 
Exit Code: -2135228415
Output:
VBoxManage.exe: error: Could not find a registered machine named 'boinc_ef3d5802bf012a72'
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown
VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2715 of file VBoxManageInfo.cpp

2021-04-16 02:27:13 (1408): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\8/vm_image.vdi" 
Exit Code: -2135228412
Output:
VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\8\vm_image.vdi' (VERR_FILE_NOT_FOUND)
VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp

2021-04-16 02:27:13 (1408): 
Command: VBoxManage -q createvm --name "boinc_ef3d5802bf012a72" --basefolder "C:\ProgramData\BOINC\slots\8" --ostype "Linux26_64" --register
Exit Code: 0
Output:
Virtual machine 'boinc_ef3d5802bf012a72' is created and registered.
UUID: 195bb617-83e7-498c-8aa9-94b2812c75e7
Settings file: 'C:\ProgramData\BOINC\slots\8\boinc_ef3d5802bf012a72\boinc_ef3d5802bf012a72.vbox'

2021-04-16 02:27:13 (1408): 
Command: VBoxManage -q modifyvm "boinc_ef3d5802bf012a72" --description "08280632_07_2" 
Exit Code: 0
Output:

2021-04-16 02:27:14 (1408): 
Command: VBoxManage -q modifyvm "boinc_ef3d5802bf012a72" --memory 3072 
Exit Code: 0
Output:

2021-04-16 02:27:14 (1408): 
Command: VBoxManage -q modifyvm "boinc_ef3d5802bf012a72" --cpus 1 
Exit Code: 0
Output:

2021-04-16 02:27:14 (1408): 
Command: VBoxManage -q modifyvm "boinc_ef3d5802bf012a72" --acpi on --ioapic on 
Exit Code: 0
Output:

2021-04-16 02:27:15 (1408): 
Command: VBoxManage -q modifyvm "boinc_ef3d5802bf012a72" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2021-04-16 02:27:15 (1408): 
Command: VBoxManage -q modifyvm "boinc_ef3d5802bf012a72" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2021-04-16 02:27:15 (1408): 
Command: VBoxManage -q modifyvm "boinc_ef3d5802bf012a72" --cableconnected1 on 
Exit Code: 0
Output:

2021-04-16 02:27:15 (1408): 
Command: VBoxManage -q modifyvm "boinc_ef3d5802bf012a72" --usb off 
Exit Code: 0
Output:

2021-04-16 02:27:16 (1408): 
Command: VBoxManage -q modifyvm "boinc_ef3d5802bf012a72" --uart1 off --uart2 off 
Exit Code: 0
Output:

2021-04-16 02:27:16 (1408): 
Command: VBoxManage -q modifyvm "boinc_ef3d5802bf012a72" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2021-04-16 02:27:16 (1408): 
Command: VBoxManage -q modifyvm "boinc_ef3d5802bf012a72" --audio none 
Exit Code: 0
Output:

2021-04-16 02:27:17 (1408): 
Command: VBoxManage -q modifyvm "boinc_ef3d5802bf012a72" --clipboard disabled 
Exit Code: 0
Output:

2021-04-16 02:27:17 (1408): 
Command: VBoxManage -q modifyvm "boinc_ef3d5802bf012a72" --draganddrop disabled 
Exit Code: 0
Output:

2021-04-16 02:27:17 (1408): 
Command: VBoxManage -q storagectl "boinc_ef3d5802bf012a72" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2021-04-16 02:27:17 (1408): 
Command: VBoxManage -q storageattach "boinc_ef3d5802bf012a72" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\ProgramData\BOINC\slots\8/vm_isocontext.iso" 
Exit Code: 0
Output:

2021-04-16 02:27:18 (1408): 
Command: VBoxManage -q storageattach "boinc_ef3d5802bf012a72" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2021-04-16 02:27:18 (1408): 
Command: VBoxManage -q bandwidthctl "boinc_ef3d5802bf012a72" add "boinc_ef3d5802bf012a72_net" --type network --limit 1024G 
Exit Code: 0
Output:

2021-04-16 02:27:18 (1408): 
Command: VBoxManage -q sharedfolder add "boinc_ef3d5802bf012a72" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\8/shared"
Exit Code: 0
Output:

2021-04-16 02:27:20 (1408): 
Command: VBoxManage -q startvm "boinc_ef3d5802bf012a72" --type headless
Exit Code: 1
Output:
Waiting for VM "boinc_ef3d5802bf012a72" to power on...
VBoxManage.exe: error: The virtual machine 'boinc_ef3d5802bf012a72' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\8\boinc_ef3d5802bf012a72\Logs\VBoxHardening.log'
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine

2021-04-16 02:27:20 (1408): 
Command: VBoxManage -q snapshot "boinc_ef3d5802bf012a72" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2021-04-16 02:27:21 (1408): 
Command: VBoxManage -q bandwidthctl "boinc_ef3d5802bf012a72" remove "boinc_ef3d5802bf012a72_net" 
Exit Code: 0
Output:

2021-04-16 02:27:21 (1408): 
Command: VBoxManage -q unregistervm "boinc_ef3d5802bf012a72" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

2021-04-16 02:27:21 (1408): 
Command: VBoxManage -q closemedium dvd "C:\ProgramData\BOINC\slots\8/vm_isocontext.iso" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

02:27:27 (1408): called boinc_finish(1)

</stderr_txt>
]]>


©2024 COPYRIGHT 2017-2018 NCN