Task 10232134

Name 08283440_30_1
Workunit 7993578
Created 16 Apr 2021, 9:22:17 UTC
Sent 16 Apr 2021, 9:25:38 UTC
Report deadline 21 Apr 2021, 9:25:38 UTC
Received 16 Apr 2021, 9:45:35 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status 1 (0x00000001) Unknown error code
Computer ID 10225
Run time 20 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 2.94 GFLOPS
Application version boinc2docker v1.14 (vbox64_mt)
windows_x86_64
Peak working set size 7.32 MB
Peak swap size 2.36 MB
Peak disk usage 227.37 MB

Stderr output

<core_client_version>7.16.11</core_client_version>
<![CDATA[
<message>
Incorrect function.
 (0x1) - exit code 1 (0x1)</message>
<stderr_txt>
2021-04-16 02:28:24 (4784): Detected: vboxwrapper 26202
2021-04-16 02:28:24 (4784): Detected: BOINC client v7.16.11
2021-04-16 02:28:25 (4784): Detected: VirtualBox VboxManage Interface (Version: 6.1.12)
2021-04-16 02:28:26 (4784): Create VM. (boinc_b13c06a9bd0b7557, slot#1)
2021-04-16 02:28:26 (4784): Updating drive controller type and model for desired configuration.
2021-04-16 02:28:27 (4784): Setting Memory Size for VM. (3072MB)
2021-04-16 02:28:28 (4784): Setting CPU Count for VM. (1)
2021-04-16 02:28:28 (4784): Setting Chipset Options for VM.
2021-04-16 02:28:28 (4784): Setting Boot Options for VM.
2021-04-16 02:28:28 (4784): Setting Network Configuration for NAT.
2021-04-16 02:28:29 (4784): Enabling VM Network Access.
2021-04-16 02:28:29 (4784): Disabling USB Support for VM.
2021-04-16 02:28:29 (4784): Disabling COM Port Support for VM.
2021-04-16 02:28:30 (4784): Disabling LPT Port Support for VM.
2021-04-16 02:28:30 (4784): Disabling Audio Support for VM.
2021-04-16 02:28:30 (4784): Disabling Clipboard Support for VM.
2021-04-16 02:28:31 (4784): Disabling Drag and Drop Support for VM.
2021-04-16 02:28:31 (4784): Adding storage controller(s) to VM.
2021-04-16 02:28:31 (4784): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso)
2021-04-16 02:28:32 (4784): Adding VirtualBox Guest Additions to VM.
2021-04-16 02:28:32 (4784): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2021-04-16 02:28:32 (4784): Enabling shared directory for VM.
2021-04-16 02:28:33 (4784): Starting VM using VBoxManage interface. (boinc_b13c06a9bd0b7557, slot#1)
2021-04-16 02:28:34 (4784): Error in start VM for VM: 1
Command:
VBoxManage -q startvm "boinc_b13c06a9bd0b7557" --type headless
Output:
Waiting for VM "boinc_b13c06a9bd0b7557" to power on...
VBoxManage.exe: error: The virtual machine 'boinc_b13c06a9bd0b7557' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\1\boinc_b13c06a9bd0b7557\Logs\VBoxHardening.log'
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine

2021-04-16 02:28:34 (4784): VM failed to start.
2021-04-16 02:28:34 (4784): Could not start 
2021-04-16 02:28:34 (4784): ERROR: VM failed to start
2021-04-16 02:28:34 (4784): Powering off VM.
2021-04-16 02:28:34 (4784): Deregistering VM. (boinc_b13c06a9bd0b7557, slot#1)
2021-04-16 02:28:34 (4784): Removing network bandwidth throttle group from VM.
2021-04-16 02:28:35 (4784): Removing VM from VirtualBox.
2021-04-16 02:28:35 (4784): Removing virtual ISO 9660 disk from VirtualBox.

    Hypervisor System Log:

00:00:07.378813          Saving settings file "C:\Users\wjs\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:07.394413          Saving settings file "C:\Users\wjs\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:07.394413          Saving settings file "C:\Users\wjs\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:07.410013          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_b13c06a9bd0b7557\boinc_b13c06a9bd0b7557.vbox" with version "1.16-windows"
00:00:07.410013          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_232da50686c7c50b\boinc_232da50686c7c50b.vbox" with version "1.16-windows"
00:00:07.659613          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.659613          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.659613          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.659613          Saving settings file "C:\Users\wjs\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:07.659613          ERROR [COM]: aRC=E_INVALIDARG (0x80070057) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={Cannot register the DVD image 'C:\Program Files\Oracle\VirtualBox\VBoxGuestAdditions.iso' {53d894f1-d2a4-4599-a4a9-e50625a65971} because a CD/DVD image 'C:\Program Files\Oracle\VirtualBox\VBoxGuestAdditions.iso' with UUID {bccd019c-82e6-4fe8-8101-764837b81e05} already exists}, preserve=false aResultDetail=0
00:00:07.675213          Saving settings file "C:\Users\wjs\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:07.722013          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_b13c06a9bd0b7557\boinc_b13c06a9bd0b7557.vbox" with version "1.16-windows"
00:00:07.924813          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_b13c06a9bd0b7557\boinc_b13c06a9bd0b7557.vbox" with version "1.16-windows"
00:00:08.221214          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_b13c06a9bd0b7557\boinc_b13c06a9bd0b7557.vbox" with version "1.16-windows"
00:00:08.798415          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.798415          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.798415          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:08.954415          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.954415          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.954415          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_232da50686c7c50b\boinc_232da50686c7c50b.vbox" with version "1.16-windows"
00:00:09.110416          Launched VM: 68428384 pid: 3624 (0xe28) frontend: headless name: boinc_b13c06a9bd0b7557
00:00:09.250816          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_232da50686c7c50b\boinc_232da50686c7c50b.vbox" with version "1.16-windows"
00:00:09.562816          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_232da50686c7c50b\boinc_232da50686c7c50b.vbox" with version "1.16-windows"
00:00:09.812417          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:09.812417          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:09.812417          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:10.046417 Watcher  ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={The virtual machine 'boinc_b13c06a9bd0b7557' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\1\boinc_b13c06a9bd0b7557\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0
00:00:10.046417 Watcher  Reaper: Pid 3624 (e28) exited normally: 1 (0x1)
00:00:10.140017          Launched VM: 68428816 pid: 5264 (0x1490) frontend: headless name: boinc_232da50686c7c50b
00:00:10.264818          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:10.420818          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_b13c06a9bd0b7557\boinc_b13c06a9bd0b7557.vbox" with version "1.16-windows"
00:00:10.717218          Saving settings file "C:\Users\wjs\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:11.076019 Watcher  ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={The virtual machine 'boinc_232da50686c7c50b' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\0\boinc_232da50686c7c50b\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0
00:00:11.076019 Watcher  Reaper: Pid 5264 (1490) exited normally: 1 (0x1)
00:00:11.263219          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:11.419220          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_232da50686c7c50b\boinc_232da50686c7c50b.vbox" with version "1.16-windows"
00:00:11.715620          Saving settings file "C:\Users\wjs\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:17.019629 main     VirtualBox: object deletion starts
00:00:17.019629 main     ERROR [COM]: aRC=VBOX_E_OBJECT_IN_USE (0x80bb000c) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Medium 'C:\Users\wjs\VirtualBox VMs\zardoz\zardoz.vdi' cannot be closed because it is still attached to 1 virtual machines}, preserve=false aResultDetail=0
00:00:17.019629 main     HostDnsMonitor: shutting down ...
00:00:17.019629 main     HostDnsMonitor: shut down
00:00:17.019629 Watcher  ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0
00:00:17.019629 main     VirtualBox: object deleted

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

mum ICH9 SATA Controllers:   8
Maximum SATA Port count:         30
Maximum Devices per SATA Port:   1
Maximum PIIX3 SCSI Controllers:  1
Maximum ICH9 SCSI Controllers:   8
Maximum SCSI Port count:         16
Maximum Devices per SCSI Port:   1
Maximum SAS PIIX3 Controllers:   1
Maximum SAS ICH9 Controllers:    8
Maximum SAS Port count:          255
Maximum Devices per SAS Port:    1
Maximum NVMe PIIX3 Controllers:  1
Maximum NVMe ICH9 Controllers:   8
Maximum NVMe Port count:         255
Maximum Devices per NVMe Port:   1
Maximum virtio-scsi PIIX3 Controllers:  1
Maximum virtio-scsi ICH9 Controllers:   8
Maximum virtio-scsi Port count:         256
Maximum Devices per virtio-scsi Port:   1
Maximum PIIX3 Floppy Controllers:1
Maximum ICH9 Floppy Controllers: 1
Maximum Floppy Port count:       1
Maximum Devices per Floppy Port: 2
Default machine folder:          C:\Users\wjs\VirtualBox VMs
Raw-mode Supported:              no
Exclusive HW virtualization use: off
Default hard disk format:        VDI
VRDE auth library:               VBoxAuth
Webservice auth. library:        VBoxAuth
Remote desktop ExtPack:          
Log history count:               3
Default frontend:                
Default audio driver:            DirectSound
Autostart database path:         
Default Guest Additions ISO:     C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso
Logging Level:                   all
Proxy Mode:                      System
Proxy URL:                       

2021-04-16 02:28:26 (4784): 
Command: VBoxManage -q list hostinfo 
Exit Code: 0
Output:
Host Information:

Host time: 2021-04-16T09:28:26.144000000Z
Processor online count: 4
Processor count: 4
Processor online core count: 4
Processor core count: 4
Processor supports HW virtualization: yes
Processor supports PAE: yes
Processor supports long mode: yes
Processor supports nested paging: no
Processor supports unrestricted guest: no
Processor supports nested HW virtualization: no
Processor#0 speed: unknown
Processor#0 description: Intel(R) Core(TM)2 Quad CPU    Q8300  @ 2.50GHz
Processor#1 speed: unknown
Processor#1 description: Intel(R) Core(TM)2 Quad CPU    Q8300  @ 2.50GHz
Processor#2 speed: unknown
Processor#2 description: Intel(R) Core(TM)2 Quad CPU    Q8300  @ 2.50GHz
Processor#3 speed: unknown
Processor#3 description: Intel(R) Core(TM)2 Quad CPU    Q8300  @ 2.50GHz
Memory size: 6143 MByte
Memory available: 3592 MByte
Operating system: Windows 7
Operating system version: 6.1.7601sp1

2021-04-16 02:28:26 (4784): 
Command: VBoxManage -q showvminfo "boinc_b13c06a9bd0b7557" --machinereadable 
Exit Code: -2135228415
Output:
VBoxManage.exe: error: Could not find a registered machine named 'boinc_b13c06a9bd0b7557'
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown
VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2715 of file VBoxManageInfo.cpp

2021-04-16 02:28:26 (4784): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\1/vm_image.vdi" 
Exit Code: -2135228412
Output:
VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\1\vm_image.vdi' (VERR_FILE_NOT_FOUND)
VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp

2021-04-16 02:28:27 (4784): 
Command: VBoxManage -q createvm --name "boinc_b13c06a9bd0b7557" --basefolder "C:\ProgramData\BOINC\slots\1" --ostype "Linux26_64" --register
Exit Code: 0
Output:
Virtual machine 'boinc_b13c06a9bd0b7557' is created and registered.
UUID: bb9db960-bf72-446e-9b7b-329ae14db145
Settings file: 'C:\ProgramData\BOINC\slots\1\boinc_b13c06a9bd0b7557\boinc_b13c06a9bd0b7557.vbox'

2021-04-16 02:28:27 (4784): 
Command: VBoxManage -q modifyvm "boinc_b13c06a9bd0b7557" --description "08283440_30_1" 
Exit Code: 0
Output:

2021-04-16 02:28:28 (4784): 
Command: VBoxManage -q modifyvm "boinc_b13c06a9bd0b7557" --memory 3072 
Exit Code: 0
Output:

2021-04-16 02:28:28 (4784): 
Command: VBoxManage -q modifyvm "boinc_b13c06a9bd0b7557" --cpus 1 
Exit Code: 0
Output:

2021-04-16 02:28:28 (4784): 
Command: VBoxManage -q modifyvm "boinc_b13c06a9bd0b7557" --acpi on --ioapic on 
Exit Code: 0
Output:

2021-04-16 02:28:28 (4784): 
Command: VBoxManage -q modifyvm "boinc_b13c06a9bd0b7557" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2021-04-16 02:28:29 (4784): 
Command: VBoxManage -q modifyvm "boinc_b13c06a9bd0b7557" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2021-04-16 02:28:29 (4784): 
Command: VBoxManage -q modifyvm "boinc_b13c06a9bd0b7557" --cableconnected1 on 
Exit Code: 0
Output:

2021-04-16 02:28:29 (4784): 
Command: VBoxManage -q modifyvm "boinc_b13c06a9bd0b7557" --usb off 
Exit Code: 0
Output:

2021-04-16 02:28:30 (4784): 
Command: VBoxManage -q modifyvm "boinc_b13c06a9bd0b7557" --uart1 off --uart2 off 
Exit Code: 0
Output:

2021-04-16 02:28:30 (4784): 
Command: VBoxManage -q modifyvm "boinc_b13c06a9bd0b7557" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2021-04-16 02:28:30 (4784): 
Command: VBoxManage -q modifyvm "boinc_b13c06a9bd0b7557" --audio none 
Exit Code: 0
Output:

2021-04-16 02:28:31 (4784): 
Command: VBoxManage -q modifyvm "boinc_b13c06a9bd0b7557" --clipboard disabled 
Exit Code: 0
Output:

2021-04-16 02:28:31 (4784): 
Command: VBoxManage -q modifyvm "boinc_b13c06a9bd0b7557" --draganddrop disabled 
Exit Code: 0
Output:

2021-04-16 02:28:31 (4784): 
Command: VBoxManage -q storagectl "boinc_b13c06a9bd0b7557" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2021-04-16 02:28:32 (4784): 
Command: VBoxManage -q storageattach "boinc_b13c06a9bd0b7557" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\ProgramData\BOINC\slots\1/vm_isocontext.iso" 
Exit Code: 0
Output:

2021-04-16 02:28:32 (4784): 
Command: VBoxManage -q storageattach "boinc_b13c06a9bd0b7557" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2021-04-16 02:28:32 (4784): 
Command: VBoxManage -q bandwidthctl "boinc_b13c06a9bd0b7557" add "boinc_b13c06a9bd0b7557_net" --type network --limit 1024G 
Exit Code: 0
Output:

2021-04-16 02:28:33 (4784): 
Command: VBoxManage -q sharedfolder add "boinc_b13c06a9bd0b7557" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\1/shared"
Exit Code: 0
Output:

2021-04-16 02:28:34 (4784): 
Command: VBoxManage -q startvm "boinc_b13c06a9bd0b7557" --type headless
Exit Code: 1
Output:
Waiting for VM "boinc_b13c06a9bd0b7557" to power on...
VBoxManage.exe: error: The virtual machine 'boinc_b13c06a9bd0b7557' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\1\boinc_b13c06a9bd0b7557\Logs\VBoxHardening.log'
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine

2021-04-16 02:28:34 (4784): 
Command: VBoxManage -q snapshot "boinc_b13c06a9bd0b7557" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2021-04-16 02:28:35 (4784): 
Command: VBoxManage -q bandwidthctl "boinc_b13c06a9bd0b7557" remove "boinc_b13c06a9bd0b7557_net" 
Exit Code: 0
Output:

2021-04-16 02:28:35 (4784): 
Command: VBoxManage -q unregistervm "boinc_b13c06a9bd0b7557" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

2021-04-16 02:28:35 (4784): 
Command: VBoxManage -q closemedium dvd "C:\ProgramData\BOINC\slots\1/vm_isocontext.iso" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

02:28:42 (4784): called boinc_finish(1)

</stderr_txt>
]]>