Name | 08285106_54_0 |
Workunit | 8023034 |
Created | 16 Apr 2021, 10:26:09 UTC |
Sent | 16 Apr 2021, 13:54:55 UTC |
Report deadline | 21 Apr 2021, 13:54:55 UTC |
Received | 16 Apr 2021, 16:18:04 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | 1 (0x00000001) Unknown error code |
Computer ID | 10225 |
Run time | 25 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 2.94 GFLOPS |
Application version | boinc2docker v1.14 (vbox64_mt) windows_x86_64 |
Peak working set size | 4.94 MB |
Peak swap size | 2.04 MB |
Peak disk usage | 278.17 MB |
<core_client_version>7.16.11</core_client_version> <![CDATA[ <message> Incorrect function. (0x1) - exit code 1 (0x1)</message> <stderr_txt> 2021-04-16 06:58:28 (8340): Detected: vboxwrapper 26202 2021-04-16 06:58:28 (8340): Detected: BOINC client v7.16.11 2021-04-16 06:58:30 (8340): Detected: VirtualBox VboxManage Interface (Version: 6.1.12) 2021-04-16 06:58:31 (8340): Create VM. (boinc_ec72637ddd89f684, slot#1) 2021-04-16 06:58:31 (8340): Updating drive controller type and model for desired configuration. 2021-04-16 06:58:34 (8340): Setting Memory Size for VM. (3072MB) 2021-04-16 06:58:35 (8340): Setting CPU Count for VM. (1) 2021-04-16 06:58:36 (8340): Setting Chipset Options for VM. 2021-04-16 06:58:37 (8340): Setting Boot Options for VM. 2021-04-16 06:58:37 (8340): Setting Network Configuration for NAT. 2021-04-16 06:58:37 (8340): Enabling VM Network Access. 2021-04-16 06:58:38 (8340): Disabling USB Support for VM. 2021-04-16 06:58:38 (8340): Disabling COM Port Support for VM. 2021-04-16 06:58:39 (8340): Disabling LPT Port Support for VM. 2021-04-16 06:58:39 (8340): Disabling Audio Support for VM. 2021-04-16 06:58:39 (8340): Disabling Clipboard Support for VM. 2021-04-16 06:58:40 (8340): Disabling Drag and Drop Support for VM. 2021-04-16 06:58:40 (8340): Adding storage controller(s) to VM. 2021-04-16 06:58:40 (8340): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso) 2021-04-16 06:58:41 (8340): Adding VirtualBox Guest Additions to VM. 2021-04-16 06:58:41 (8340): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2021-04-16 06:58:41 (8340): Enabling shared directory for VM. 2021-04-16 06:58:42 (8340): Starting VM using VBoxManage interface. (boinc_ec72637ddd89f684, slot#1) 2021-04-16 06:58:43 (8340): Error in start VM for VM: 1 Command: VBoxManage -q startvm "boinc_ec72637ddd89f684" --type headless Output: Waiting for VM "boinc_ec72637ddd89f684" to power on... VBoxManage.exe: error: The virtual machine 'boinc_ec72637ddd89f684' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\1\boinc_ec72637ddd89f684\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine 2021-04-16 06:58:43 (8340): VM failed to start. 2021-04-16 06:58:43 (8340): Could not start 2021-04-16 06:58:43 (8340): ERROR: VM failed to start 2021-04-16 06:58:43 (8340): Powering off VM. 2021-04-16 06:58:43 (8340): Deregistering VM. (boinc_ec72637ddd89f684, slot#1) 2021-04-16 06:58:43 (8340): Removing network bandwidth throttle group from VM. 2021-04-16 06:58:44 (8340): Removing VM from VirtualBox. 2021-04-16 06:58:44 (8340): Removing virtual ISO 9660 disk from VirtualBox. Hypervisor System Log: 00:00:11.784017 Saving settings file "C:\Users\wjs\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:11.844017 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_ec72637ddd89f684\boinc_ec72637ddd89f684.vbox" with version "1.16-windows" 00:00:12.034018 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_f8c7e066708ce69c\boinc_f8c7e066708ce69c.vbox" with version "1.16-windows" 00:00:12.264018 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:12.284018 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:12.284018 Saving settings file "C:\Users\wjs\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:12.294018 Saving settings file "C:\Users\wjs\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:12.314018 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_ec72637ddd89f684\boinc_ec72637ddd89f684.vbox" with version "1.16-windows" 00:00:12.314018 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:12.324018 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:12.324018 Saving settings file "C:\Users\wjs\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:12.334018 Saving settings file "C:\Users\wjs\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:12.354018 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_f8c7e066708ce69c\boinc_f8c7e066708ce69c.vbox" with version "1.16-windows" 00:00:12.534018 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_ec72637ddd89f684\boinc_ec72637ddd89f684.vbox" with version "1.16-windows" 00:00:12.594019 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:12.594019 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:12.594019 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_f8c7e066708ce69c\boinc_f8c7e066708ce69c.vbox" with version "1.16-windows" 00:00:12.815019 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_ec72637ddd89f684\boinc_ec72637ddd89f684.vbox" with version "1.16-windows" 00:00:12.905019 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_f8c7e066708ce69c\boinc_f8c7e066708ce69c.vbox" with version "1.16-windows" 00:00:13.095019 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:13.105019 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:13.115019 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:13.155019 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_f8c7e066708ce69c\boinc_f8c7e066708ce69c.vbox" with version "1.16-windows" 00:00:13.415020 Launched VM: 68674448 pid: 9192 (0x23e8) frontend: headless name: boinc_ec72637ddd89f684 00:00:13.465020 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:13.465020 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:13.475020 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:13.735020 Launched VM: 68623024 pid: 7276 (0x1c6c) frontend: headless name: boinc_f8c7e066708ce69c 00:00:14.365021 Watcher ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={The virtual machine 'boinc_ec72637ddd89f684' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\1\boinc_ec72637ddd89f684\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0 00:00:14.365021 Watcher Reaper: Pid 9192 (23e8) exited normally: 1 (0x1) 00:00:14.555021 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:14.665021 Watcher ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={The virtual machine 'boinc_f8c7e066708ce69c' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\0\boinc_f8c7e066708ce69c\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0 00:00:14.735022 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_ec72637ddd89f684\boinc_ec72637ddd89f684.vbox" with version "1.16-windows" 00:00:14.855022 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:15.015022 Saving settings file "C:\Users\wjs\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:15.035022 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_f8c7e066708ce69c\boinc_f8c7e066708ce69c.vbox" with version "1.16-windows" 00:00:15.295022 Saving settings file "C:\Users\wjs\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:20.596030 main VirtualBox: object deletion starts 00:00:20.596030 main ERROR [COM]: aRC=VBOX_E_OBJECT_IN_USE (0x80bb000c) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Medium 'C:\Users\wjs\VirtualBox VMs\zardoz\zardoz.vdi' cannot be closed because it is still attached to 1 virtual machines}, preserve=false aResultDetail=0 00:00:20.596030 main HostDnsMonitor: shutting down ... 00:00:20.596030 main HostDnsMonitor: shut down 00:00:20.596030 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:20.596030 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: imum ICH9 SATA Controllers: 8 Maximum SATA Port count: 30 Maximum Devices per SATA Port: 1 Maximum PIIX3 SCSI Controllers: 1 Maximum ICH9 SCSI Controllers: 8 Maximum SCSI Port count: 16 Maximum Devices per SCSI Port: 1 Maximum SAS PIIX3 Controllers: 1 Maximum SAS ICH9 Controllers: 8 Maximum SAS Port count: 255 Maximum Devices per SAS Port: 1 Maximum NVMe PIIX3 Controllers: 1 Maximum NVMe ICH9 Controllers: 8 Maximum NVMe Port count: 255 Maximum Devices per NVMe Port: 1 Maximum virtio-scsi PIIX3 Controllers: 1 Maximum virtio-scsi ICH9 Controllers: 8 Maximum virtio-scsi Port count: 256 Maximum Devices per virtio-scsi Port: 1 Maximum PIIX3 Floppy Controllers:1 Maximum ICH9 Floppy Controllers: 1 Maximum Floppy Port count: 1 Maximum Devices per Floppy Port: 2 Default machine folder: C:\Users\wjs\VirtualBox VMs Raw-mode Supported: no Exclusive HW virtualization use: off Default hard disk format: VDI VRDE auth library: VBoxAuth Webservice auth. library: VBoxAuth Remote desktop ExtPack: Log history count: 3 Default frontend: Default audio driver: DirectSound Autostart database path: Default Guest Additions ISO: C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso Logging Level: all Proxy Mode: System Proxy URL: 2021-04-16 06:58:30 (8340): Command: VBoxManage -q list hostinfo Exit Code: 0 Output: Host Information: Host time: 2021-04-16T13:58:30.737000000Z Processor online count: 4 Processor count: 4 Processor online core count: 4 Processor core count: 4 Processor supports HW virtualization: yes Processor supports PAE: yes Processor supports long mode: yes Processor supports nested paging: no Processor supports unrestricted guest: no Processor supports nested HW virtualization: no Processor#0 speed: unknown Processor#0 description: Intel(R) Core(TM)2 Quad CPU Q8300 @ 2.50GHz Processor#1 speed: unknown Processor#1 description: Intel(R) Core(TM)2 Quad CPU Q8300 @ 2.50GHz Processor#2 speed: unknown Processor#2 description: Intel(R) Core(TM)2 Quad CPU Q8300 @ 2.50GHz Processor#3 speed: unknown Processor#3 description: Intel(R) Core(TM)2 Quad CPU Q8300 @ 2.50GHz Memory size: 6143 MByte Memory available: 966 MByte Operating system: Windows 7 Operating system version: 6.1.7601sp1 2021-04-16 06:58:31 (8340): Command: VBoxManage -q showvminfo "boinc_ec72637ddd89f684" --machinereadable Exit Code: -2135228415 Output: VBoxManage.exe: error: Could not find a registered machine named 'boinc_ec72637ddd89f684' VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2715 of file VBoxManageInfo.cpp 2021-04-16 06:58:31 (8340): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\1/vm_image.vdi" Exit Code: -2135228412 Output: VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\1\vm_image.vdi' (VERR_FILE_NOT_FOUND) VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp 2021-04-16 06:58:32 (8340): Command: VBoxManage -q createvm --name "boinc_ec72637ddd89f684" --basefolder "C:\ProgramData\BOINC\slots\1" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_ec72637ddd89f684' is created and registered. UUID: b50d4d42-8e20-4952-800c-d89c60f30a9c Settings file: 'C:\ProgramData\BOINC\slots\1\boinc_ec72637ddd89f684\boinc_ec72637ddd89f684.vbox' 2021-04-16 06:58:34 (8340): Command: VBoxManage -q modifyvm "boinc_ec72637ddd89f684" --description "08285106_54_0" Exit Code: 0 Output: 2021-04-16 06:58:35 (8340): Command: VBoxManage -q modifyvm "boinc_ec72637ddd89f684" --memory 3072 Exit Code: 0 Output: 2021-04-16 06:58:36 (8340): Command: VBoxManage -q modifyvm "boinc_ec72637ddd89f684" --cpus 1 Exit Code: 0 Output: 2021-04-16 06:58:37 (8340): Command: VBoxManage -q modifyvm "boinc_ec72637ddd89f684" --acpi on --ioapic on Exit Code: 0 Output: 2021-04-16 06:58:37 (8340): Command: VBoxManage -q modifyvm "boinc_ec72637ddd89f684" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2021-04-16 06:58:37 (8340): Command: VBoxManage -q modifyvm "boinc_ec72637ddd89f684" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2021-04-16 06:58:38 (8340): Command: VBoxManage -q modifyvm "boinc_ec72637ddd89f684" --cableconnected1 on Exit Code: 0 Output: 2021-04-16 06:58:38 (8340): Command: VBoxManage -q modifyvm "boinc_ec72637ddd89f684" --usb off Exit Code: 0 Output: 2021-04-16 06:58:39 (8340): Command: VBoxManage -q modifyvm "boinc_ec72637ddd89f684" --uart1 off --uart2 off Exit Code: 0 Output: 2021-04-16 06:58:39 (8340): Command: VBoxManage -q modifyvm "boinc_ec72637ddd89f684" --lpt1 off --lpt2 off Exit Code: 0 Output: 2021-04-16 06:58:39 (8340): Command: VBoxManage -q modifyvm "boinc_ec72637ddd89f684" --audio none Exit Code: 0 Output: 2021-04-16 06:58:40 (8340): Command: VBoxManage -q modifyvm "boinc_ec72637ddd89f684" --clipboard disabled Exit Code: 0 Output: 2021-04-16 06:58:40 (8340): Command: VBoxManage -q modifyvm "boinc_ec72637ddd89f684" --draganddrop disabled Exit Code: 0 Output: 2021-04-16 06:58:40 (8340): Command: VBoxManage -q storagectl "boinc_ec72637ddd89f684" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2021-04-16 06:58:41 (8340): Command: VBoxManage -q storageattach "boinc_ec72637ddd89f684" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\ProgramData\BOINC\slots\1/vm_isocontext.iso" Exit Code: 0 Output: 2021-04-16 06:58:41 (8340): Command: VBoxManage -q storageattach "boinc_ec72637ddd89f684" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2021-04-16 06:58:41 (8340): Command: VBoxManage -q bandwidthctl "boinc_ec72637ddd89f684" add "boinc_ec72637ddd89f684_net" --type network --limit 1024G Exit Code: 0 Output: 2021-04-16 06:58:42 (8340): Command: VBoxManage -q sharedfolder add "boinc_ec72637ddd89f684" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\1/shared" Exit Code: 0 Output: 2021-04-16 06:58:43 (8340): Command: VBoxManage -q startvm "boinc_ec72637ddd89f684" --type headless Exit Code: 1 Output: Waiting for VM "boinc_ec72637ddd89f684" to power on... VBoxManage.exe: error: The virtual machine 'boinc_ec72637ddd89f684' has terminated unexpectedly during startup with exit code 1 (0x1). More details may be available in 'C:\ProgramData\BOINC\slots\1\boinc_ec72637ddd89f684\Logs\VBoxHardening.log' VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine 2021-04-16 06:58:43 (8340): Command: VBoxManage -q snapshot "boinc_ec72637ddd89f684" list Exit Code: -108 Output: This machine does not have any snapshots 2021-04-16 06:58:44 (8340): Command: VBoxManage -q bandwidthctl "boinc_ec72637ddd89f684" remove "boinc_ec72637ddd89f684_net" Exit Code: 0 Output: 2021-04-16 06:58:44 (8340): Command: VBoxManage -q unregistervm "boinc_ec72637ddd89f684" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 2021-04-16 06:58:44 (8340): Command: VBoxManage -q closemedium dvd "C:\ProgramData\BOINC\slots\1/vm_isocontext.iso" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 06:58:50 (8340): called boinc_finish(1) </stderr_txt> ]]>
©2025 COPYRIGHT 2017-2018 NCN