Name | 08282944_04_2 |
Workunit | 7981382 |
Created | 16 Apr 2021, 22:28:04 UTC |
Sent | 16 Apr 2021, 22:33:20 UTC |
Report deadline | 21 Apr 2021, 22:33:20 UTC |
Received | 17 Apr 2021, 22:37:00 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | -2147467259 (0x80004005) Unknown error code |
Computer ID | 10216 |
Run time | 18 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 4.44 GFLOPS |
Application version | boinc2docker v1.14 (vbox64_mt) windows_x86_64 |
Peak working set size | 11.47 MB |
Peak swap size | 6.21 MB |
Peak disk usage | 273.82 MB |
<core_client_version>7.16.11</core_client_version> <![CDATA[ <message> Unspecified error (0x80004005) - exit code 2147500037 (0x80004005)</message> <stderr_txt> 2021-04-16 17:35:53 (6060): Detected: vboxwrapper 26202 2021-04-16 17:35:53 (6060): Detected: BOINC client v7.16.11 2021-04-16 17:35:54 (6060): Detected: VirtualBox VboxManage Interface (Version: 6.1.12) 2021-04-16 17:35:55 (6060): Create VM. (boinc_d8084953bea6ed0d, slot#10) 2021-04-16 17:35:55 (6060): Updating drive controller type and model for desired configuration. 2021-04-16 17:35:55 (6060): Setting Memory Size for VM. (3072MB) 2021-04-16 17:35:55 (6060): Setting CPU Count for VM. (1) 2021-04-16 17:35:56 (6060): Setting Chipset Options for VM. 2021-04-16 17:35:56 (6060): Setting Boot Options for VM. 2021-04-16 17:35:56 (6060): Setting Network Configuration for NAT. 2021-04-16 17:35:56 (6060): Enabling VM Network Access. 2021-04-16 17:35:57 (6060): Disabling USB Support for VM. 2021-04-16 17:35:57 (6060): Disabling COM Port Support for VM. 2021-04-16 17:35:57 (6060): Disabling LPT Port Support for VM. 2021-04-16 17:35:57 (6060): Disabling Audio Support for VM. 2021-04-16 17:35:58 (6060): Disabling Clipboard Support for VM. 2021-04-16 17:35:58 (6060): Disabling Drag and Drop Support for VM. 2021-04-16 17:35:58 (6060): Adding storage controller(s) to VM. 2021-04-16 17:35:58 (6060): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso) 2021-04-16 17:35:59 (6060): Adding VirtualBox Guest Additions to VM. 2021-04-16 17:35:59 (6060): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2021-04-16 17:35:59 (6060): Enabling shared directory for VM. 2021-04-16 17:36:00 (6060): Starting VM using VBoxManage interface. (boinc_d8084953bea6ed0d, slot#10) 2021-04-16 17:36:02 (6060): Error in start VM for VM: -2147467259 Command: VBoxManage -q startvm "boinc_d8084953bea6ed0d" --type headless Output: Waiting for VM "boinc_d8084953bea6ed0d" to power on... VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2021-04-16 17:36:02 (6060): VM failed to start. 2021-04-16 17:36:02 (6060): Could not start 2021-04-16 17:36:02 (6060): ERROR: VM failed to start 2021-04-16 17:36:02 (6060): Powering off VM. 2021-04-16 17:36:02 (6060): Deregistering VM. (boinc_d8084953bea6ed0d, slot#10) 2021-04-16 17:36:02 (6060): Removing network bandwidth throttle group from VM. 2021-04-16 17:36:02 (6060): Removing VM from VirtualBox. 2021-04-16 17:36:02 (6060): Removing virtual ISO 9660 disk from VirtualBox. Hypervisor System Log: 00:00:06.305871 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:06.311150 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:06.319307 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:06.319401 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:06.323682 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:06.362632 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:06.363382 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:06.363495 Saving settings file "C:\Users\Administrator.SANITATIONDESKT\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:06.365668 Saving settings file "C:\Users\Administrator.SANITATIONDESKT\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:06.367832 Saving settings file "C:\ProgramData\BOINC\slots\9\boinc_ced2c4e06e2fcf6e\boinc_ced2c4e06e2fcf6e.vbox" with version "1.16-windows" 00:00:06.471961 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_b43d72119bb72235\boinc_b43d72119bb72235.vbox" with version "1.16-windows" 00:00:06.568010 Launched VM: 69226144 pid: 8496 (0x2130) frontend: headless name: boinc_d8084953bea6ed0d 00:00:06.583758 Launched VM: 69284272 pid: 3924 (0xf54) frontend: headless name: boinc_d8ff8c18ab3e3f72 00:00:06.630034 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:06.630284 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:06.630615 Saving settings file "C:\ProgramData\BOINC\slots\9\boinc_ced2c4e06e2fcf6e\boinc_ced2c4e06e2fcf6e.vbox" with version "1.16-windows" 00:00:06.739393 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:06.739482 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:06.743343 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:06.893034 Saving settings file "C:\ProgramData\BOINC\slots\9\boinc_ced2c4e06e2fcf6e\boinc_ced2c4e06e2fcf6e.vbox" with version "1.16-windows" 00:00:07.003354 Launched VM: 69312048 pid: 2660 (0xa64) frontend: headless name: boinc_b43d72119bb72235 00:00:07.160692 Saving settings file "C:\ProgramData\BOINC\slots\9\boinc_ced2c4e06e2fcf6e\boinc_ced2c4e06e2fcf6e.vbox" with version "1.16-windows" 00:00:07.436409 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.436518 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.440554 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:07.689642 Launched VM: 69312000 pid: 8952 (0x22f8) frontend: headless name: boinc_ced2c4e06e2fcf6e 00:00:08.603493 Saving settings file "C:\ProgramData\BOINC\slots\10\boinc_d8084953bea6ed0d\boinc_d8084953bea6ed0d.vbox" with version "1.16-windows" 00:00:08.657970 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:08.670177 Saving settings file "C:\ProgramData\BOINC\slots\11\boinc_d8ff8c18ab3e3f72\boinc_d8ff8c18ab3e3f72.vbox" with version "1.16-windows" 00:00:08.723584 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:08.945488 Saving settings file "C:\Users\Administrator.SANITATIONDESKT\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:09.013498 Saving settings file "C:\Users\Administrator.SANITATIONDESKT\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:09.102118 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_b43d72119bb72235\boinc_b43d72119bb72235.vbox" with version "1.16-windows" 00:00:09.145621 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:09.437544 Saving settings file "C:\Users\Administrator.SANITATIONDESKT\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:09.763472 Saving settings file "C:\ProgramData\BOINC\slots\9\boinc_ced2c4e06e2fcf6e\boinc_ced2c4e06e2fcf6e.vbox" with version "1.16-windows" 00:00:09.810391 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:10.108667 Saving settings file "C:\Users\Administrator.SANITATIONDESKT\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:15.389469 main VirtualBox: object deletion starts 00:00:15.390414 main HostDnsMonitor: shutting down ... 00:00:15.390509 main HostDnsMonitor: shut down 00:00:15.392131 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:15.392305 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: 3 Controllers: 1 Maximum NVMe ICH9 Controllers: 8 Maximum NVMe Port count: 255 Maximum Devices per NVMe Port: 1 Maximum virtio-scsi PIIX3 Controllers: 1 Maximum virtio-scsi ICH9 Controllers: 8 Maximum virtio-scsi Port count: 256 Maximum Devices per virtio-scsi Port: 1 Maximum PIIX3 Floppy Controllers:1 Maximum ICH9 Floppy Controllers: 1 Maximum Floppy Port count: 1 Maximum Devices per Floppy Port: 2 Default machine folder: C:\Users\Administrator.SANITATIONDESKT\VirtualBox VMs Raw-mode Supported: no Exclusive HW virtualization use: off Default hard disk format: VDI VRDE auth library: VBoxAuth Webservice auth. library: VBoxAuth Remote desktop ExtPack: Log history count: 3 Default frontend: Default audio driver: DirectSound Autostart database path: Default Guest Additions ISO: C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso Logging Level: all Proxy Mode: System Proxy URL: 2021-04-16 17:35:54 (6060): Command: VBoxManage -q list hostinfo Exit Code: 0 Output: Host Information: Host time: 2021-04-16T22:35:54.245000000Z Processor online count: 8 Processor count: 8 Processor online core count: 4 Processor core count: 4 Processor supports HW virtualization: no Processor supports PAE: yes Processor supports long mode: yes Processor supports nested paging: no Processor supports unrestricted guest: no Processor supports nested HW virtualization: no Processor#0 speed: unknown Processor#0 description: Intel(R) Core(TM) i7-7700 CPU @ 3.60GHz Processor#1 speed: unknown Processor#1 description: Intel(R) Core(TM) i7-7700 CPU @ 3.60GHz Processor#2 speed: unknown Processor#2 description: Intel(R) Core(TM) i7-7700 CPU @ 3.60GHz Processor#3 speed: unknown Processor#3 description: Intel(R) Core(TM) i7-7700 CPU @ 3.60GHz Processor#4 speed: unknown Processor#4 description: Intel(R) Core(TM) i7-7700 CPU @ 3.60GHz Processor#5 speed: unknown Processor#5 description: Intel(R) Core(TM) i7-7700 CPU @ 3.60GHz Processor#6 speed: unknown Processor#6 description: Intel(R) Core(TM) i7-7700 CPU @ 3.60GHz Processor#7 speed: unknown Processor#7 description: Intel(R) Core(TM) i7-7700 CPU @ 3.60GHz Memory size: 8098 MByte Memory available: 4706 MByte Operating system: Windows 10 Operating system version: 10.0.19041 2021-04-16 17:35:54 (6060): Command: VBoxManage -q showvminfo "boinc_d8084953bea6ed0d" --machinereadable Exit Code: -2135228415 Output: VBoxManage.exe: error: Could not find a registered machine named 'boinc_d8084953bea6ed0d' VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2715 of file VBoxManageInfo.cpp 2021-04-16 17:35:55 (6060): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\10/vm_image.vdi" Exit Code: -2135228412 Output: VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\10\vm_image.vdi' (VERR_FILE_NOT_FOUND) VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp 2021-04-16 17:35:55 (6060): Command: VBoxManage -q createvm --name "boinc_d8084953bea6ed0d" --basefolder "C:\ProgramData\BOINC\slots\10" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_d8084953bea6ed0d' is created and registered. UUID: b161c05d-425e-4826-9d70-f144d608a1a9 Settings file: 'C:\ProgramData\BOINC\slots\10\boinc_d8084953bea6ed0d\boinc_d8084953bea6ed0d.vbox' 2021-04-16 17:35:55 (6060): Command: VBoxManage -q modifyvm "boinc_d8084953bea6ed0d" --description "08282944_04_2" Exit Code: 0 Output: 2021-04-16 17:35:55 (6060): Command: VBoxManage -q modifyvm "boinc_d8084953bea6ed0d" --memory 3072 Exit Code: 0 Output: 2021-04-16 17:35:56 (6060): Command: VBoxManage -q modifyvm "boinc_d8084953bea6ed0d" --cpus 1 Exit Code: 0 Output: 2021-04-16 17:35:56 (6060): Command: VBoxManage -q modifyvm "boinc_d8084953bea6ed0d" --acpi on --ioapic on Exit Code: 0 Output: 2021-04-16 17:35:56 (6060): Command: VBoxManage -q modifyvm "boinc_d8084953bea6ed0d" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2021-04-16 17:35:56 (6060): Command: VBoxManage -q modifyvm "boinc_d8084953bea6ed0d" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2021-04-16 17:35:57 (6060): Command: VBoxManage -q modifyvm "boinc_d8084953bea6ed0d" --cableconnected1 on Exit Code: 0 Output: 2021-04-16 17:35:57 (6060): Command: VBoxManage -q modifyvm "boinc_d8084953bea6ed0d" --usb off Exit Code: 0 Output: 2021-04-16 17:35:57 (6060): Command: VBoxManage -q modifyvm "boinc_d8084953bea6ed0d" --uart1 off --uart2 off Exit Code: 0 Output: 2021-04-16 17:35:57 (6060): Command: VBoxManage -q modifyvm "boinc_d8084953bea6ed0d" --lpt1 off --lpt2 off Exit Code: 0 Output: 2021-04-16 17:35:58 (6060): Command: VBoxManage -q modifyvm "boinc_d8084953bea6ed0d" --audio none Exit Code: 0 Output: 2021-04-16 17:35:58 (6060): Command: VBoxManage -q modifyvm "boinc_d8084953bea6ed0d" --clipboard disabled Exit Code: 0 Output: 2021-04-16 17:35:58 (6060): Command: VBoxManage -q modifyvm "boinc_d8084953bea6ed0d" --draganddrop disabled Exit Code: 0 Output: 2021-04-16 17:35:58 (6060): Command: VBoxManage -q storagectl "boinc_d8084953bea6ed0d" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2021-04-16 17:35:59 (6060): Command: VBoxManage -q storageattach "boinc_d8084953bea6ed0d" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\ProgramData\BOINC\slots\10/vm_isocontext.iso" Exit Code: 0 Output: 2021-04-16 17:35:59 (6060): Command: VBoxManage -q storageattach "boinc_d8084953bea6ed0d" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2021-04-16 17:35:59 (6060): Command: VBoxManage -q bandwidthctl "boinc_d8084953bea6ed0d" add "boinc_d8084953bea6ed0d_net" --type network --limit 1024G Exit Code: 0 Output: 2021-04-16 17:36:00 (6060): Command: VBoxManage -q sharedfolder add "boinc_d8084953bea6ed0d" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\10/shared" Exit Code: 0 Output: 2021-04-16 17:36:02 (6060): Command: VBoxManage -q startvm "boinc_d8084953bea6ed0d" --type headless Exit Code: -2147467259 Output: Waiting for VM "boinc_d8084953bea6ed0d" to power on... VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2021-04-16 17:36:02 (6060): Command: VBoxManage -q snapshot "boinc_d8084953bea6ed0d" list Exit Code: -108 Output: This machine does not have any snapshots 2021-04-16 17:36:02 (6060): Command: VBoxManage -q bandwidthctl "boinc_d8084953bea6ed0d" remove "boinc_d8084953bea6ed0d_net" Exit Code: 0 Output: VBoxManage.exe: error: Bandwidth groups cannot be deleted while the VM is running 2021-04-16 17:36:02 (6060): Command: VBoxManage -q unregistervm "boinc_d8084953bea6ed0d" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 2021-04-16 17:36:03 (6060): Command: VBoxManage -q closemedium dvd "C:\ProgramData\BOINC\slots\10/vm_isocontext.iso" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 17:36:09 (6060): called boinc_finish(-2147467259) </stderr_txt> ]]>
©2025 COPYRIGHT 2017-2018 NCN