Task 10287216

Name 08287007_40_0
Workunit 8062711
Created 17 Apr 2021, 17:44:03 UTC
Sent 17 Apr 2021, 18:41:11 UTC
Report deadline 22 Apr 2021, 18:41:11 UTC
Received 17 Apr 2021, 19:24:06 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status 1 (0x00000001) Unknown error code
Computer ID 8974
Run time 19 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 4.18 GFLOPS
Application version boinc2docker v1.14 (vbox64_mt)
windows_x86_64
Peak working set size 10.84 MB
Peak swap size 2.91 MB
Peak disk usage 290.61 MB

Stderr output

<core_client_version>7.16.11</core_client_version>
<![CDATA[
<message>
Incorrect function.
 (0x1) - exit code 1 (0x1)</message>
<stderr_txt>
2021-04-17 19:59:32 (9128): Detected: vboxwrapper 26202
2021-04-17 19:59:32 (9128): Detected: BOINC client v7.16.11
2021-04-17 19:59:34 (9128): Detected: VirtualBox VboxManage Interface (Version: 6.1.12)
2021-04-17 19:59:34 (9128): Create VM. (boinc_e2520a5bcb5ba339, slot#11)
2021-04-17 19:59:34 (9128): Updating drive controller type and model for desired configuration.
2021-04-17 19:59:35 (9128): Setting Memory Size for VM. (3072MB)
2021-04-17 19:59:35 (9128): Setting CPU Count for VM. (1)
2021-04-17 19:59:36 (9128): Setting Chipset Options for VM.
2021-04-17 19:59:36 (9128): Setting Boot Options for VM.
2021-04-17 19:59:36 (9128): Setting Network Configuration for NAT.
2021-04-17 19:59:36 (9128): Enabling VM Network Access.
2021-04-17 19:59:37 (9128): Disabling USB Support for VM.
2021-04-17 19:59:37 (9128): Disabling COM Port Support for VM.
2021-04-17 19:59:37 (9128): Disabling LPT Port Support for VM.
2021-04-17 19:59:38 (9128): Disabling Audio Support for VM.
2021-04-17 19:59:38 (9128): Disabling Clipboard Support for VM.
2021-04-17 19:59:38 (9128): Disabling Drag and Drop Support for VM.
2021-04-17 19:59:38 (9128): Adding storage controller(s) to VM.
2021-04-17 19:59:39 (9128): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso)
2021-04-17 19:59:39 (9128): Adding VirtualBox Guest Additions to VM.
2021-04-17 19:59:39 (9128): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2021-04-17 19:59:40 (9128): Enabling shared directory for VM.
2021-04-17 19:59:40 (9128): Starting VM using VBoxManage interface. (boinc_e2520a5bcb5ba339, slot#11)
2021-04-17 19:59:42 (9128): Error in start VM for VM: 1
Command:
VBoxManage -q startvm "boinc_e2520a5bcb5ba339" --type headless
Output:
Waiting for VM "boinc_e2520a5bcb5ba339" to power on...
VBoxManage.exe: error: The virtual machine 'boinc_e2520a5bcb5ba339' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\11\boinc_e2520a5bcb5ba339\Logs\VBoxHardening.log'
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine

2021-04-17 19:59:42 (9128): VM failed to start.
2021-04-17 19:59:42 (9128): Could not start 
2021-04-17 19:59:42 (9128): ERROR: VM failed to start
2021-04-17 19:59:42 (9128): Powering off VM.
2021-04-17 19:59:42 (9128): Deregistering VM. (boinc_e2520a5bcb5ba339, slot#11)
2021-04-17 19:59:42 (9128): Removing network bandwidth throttle group from VM.
2021-04-17 19:59:43 (9128): Removing VM from VirtualBox.
2021-04-17 19:59:43 (9128): Removing virtual ISO 9660 disk from VirtualBox.

    Hypervisor System Log:

00:00:00.629300          HostDnsMonitor: old information
00:00:00.629302            no server entries
00:00:00.629304            no domain set
00:00:00.629304            no search string entries
00:00:00.629305          HostDnsMonitor: new information
00:00:00.629306            server 1: 192.168.1.254
00:00:00.629308            domain: home
00:00:00.629308            no search string entries
00:00:00.786197          SUPR0QueryVTCaps -> VERR_SVM_DISABLED
00:00:00.789849          VD: VDInit finished with VINF_SUCCESS
00:00:00.796341          VirtualBox: object created
00:00:01.471463          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={Could not find a registered machine named 'boinc_e2520a5bcb5ba339'}, preserve=false aResultDetail=0
00:00:01.761711          ERROR [COM]: aRC=VBOX_E_FILE_ERROR (0x80bb0004) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Could not find file for the medium 'C:\ProgramData\BOINC\slots\11\vm_image.vdi' (VERR_FILE_NOT_FOUND)}, preserve=false aResultDetail=-102
00:00:02.082120          Saving settings file "C:\ProgramData\BOINC\slots\11\boinc_e2520a5bcb5ba339\boinc_e2520a5bcb5ba339.vbox" with version "1.16-windows"
00:00:02.090898          Saving settings file "C:\Users\terry\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:02.379568          Saving settings file "C:\ProgramData\BOINC\slots\11\boinc_e2520a5bcb5ba339\boinc_e2520a5bcb5ba339.vbox" with version "1.16-windows"
00:00:02.663475          Saving settings file "C:\ProgramData\BOINC\slots\11\boinc_e2520a5bcb5ba339\boinc_e2520a5bcb5ba339.vbox" with version "1.16-windows"
00:00:02.924779          Saving settings file "C:\ProgramData\BOINC\slots\11\boinc_e2520a5bcb5ba339\boinc_e2520a5bcb5ba339.vbox" with version "1.16-windows"
00:00:03.196890          Saving settings file "C:\ProgramData\BOINC\slots\11\boinc_e2520a5bcb5ba339\boinc_e2520a5bcb5ba339.vbox" with version "1.16-windows"
00:00:03.484676          Saving settings file "C:\ProgramData\BOINC\slots\11\boinc_e2520a5bcb5ba339\boinc_e2520a5bcb5ba339.vbox" with version "1.16-windows"
00:00:03.773747          Saving settings file "C:\ProgramData\BOINC\slots\11\boinc_e2520a5bcb5ba339\boinc_e2520a5bcb5ba339.vbox" with version "1.16-windows"
00:00:04.056479          Saving settings file "C:\ProgramData\BOINC\slots\11\boinc_e2520a5bcb5ba339\boinc_e2520a5bcb5ba339.vbox" with version "1.16-windows"
00:00:04.290021          Saving settings file "C:\ProgramData\BOINC\slots\11\boinc_e2520a5bcb5ba339\boinc_e2520a5bcb5ba339.vbox" with version "1.16-windows"
00:00:04.576090          Saving settings file "C:\ProgramData\BOINC\slots\11\boinc_e2520a5bcb5ba339\boinc_e2520a5bcb5ba339.vbox" with version "1.16-windows"
00:00:04.868793          Saving settings file "C:\ProgramData\BOINC\slots\11\boinc_e2520a5bcb5ba339\boinc_e2520a5bcb5ba339.vbox" with version "1.16-windows"
00:00:05.158847          Saving settings file "C:\ProgramData\BOINC\slots\11\boinc_e2520a5bcb5ba339\boinc_e2520a5bcb5ba339.vbox" with version "1.16-windows"
00:00:05.460408          Saving settings file "C:\ProgramData\BOINC\slots\11\boinc_e2520a5bcb5ba339\boinc_e2520a5bcb5ba339.vbox" with version "1.16-windows"
00:00:05.747932          Saving settings file "C:\ProgramData\BOINC\slots\11\boinc_e2520a5bcb5ba339\boinc_e2520a5bcb5ba339.vbox" with version "1.16-windows"
00:00:06.025328          Saving settings file "C:\ProgramData\BOINC\slots\11\boinc_e2520a5bcb5ba339\boinc_e2520a5bcb5ba339.vbox" with version "1.16-windows"
00:00:06.327338          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.339641          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.340103          Saving settings file "C:\Users\terry\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:06.352142          Saving settings file "C:\Users\terry\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:06.362418          Saving settings file "C:\ProgramData\BOINC\slots\11\boinc_e2520a5bcb5ba339\boinc_e2520a5bcb5ba339.vbox" with version "1.16-windows"
00:00:06.596835          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.604310          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.604599          Saving settings file "C:\Users\terry\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:06.617058          Saving settings file "C:\Users\terry\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:06.629343          Saving settings file "C:\ProgramData\BOINC\slots\11\boinc_e2520a5bcb5ba339\boinc_e2520a5bcb5ba339.vbox" with version "1.16-windows"
00:00:06.857371          Saving settings file "C:\ProgramData\BOINC\slots\11\boinc_e2520a5bcb5ba339\boinc_e2520a5bcb5ba339.vbox" with version "1.16-windows"
00:00:07.157741          Saving settings file "C:\ProgramData\BOINC\slots\11\boinc_e2520a5bcb5ba339\boinc_e2520a5bcb5ba339.vbox" with version "1.16-windows"
00:00:07.461379          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.461645          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.473632          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:07.780089          Launched VM: 75709488 pid: 13848 (0x3618) frontend: headless name: boinc_e2520a5bcb5ba339
00:00:09.430609 Watcher  ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={The virtual machine 'boinc_e2520a5bcb5ba339' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\11\boinc_e2520a5bcb5ba339\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0
00:00:09.431518 Watcher  Reaper: Pid 13848 (3618) exited normally: 1 (0x1)
00:00:09.668570          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:09.887787          Saving settings file "C:\ProgramData\BOINC\slots\11\boinc_e2520a5bcb5ba339\boinc_e2520a5bcb5ba339.vbox" with version "1.16-windows"
00:00:10.159829          Saving settings file "C:\Users\terry\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:15.461945 main     VirtualBox: object deletion starts
00:00:15.462830 main     HostDnsMonitor: shutting down ...
00:00:15.462900 main     HostDnsMonitor: shut down
00:00:15.465347 Watcher  ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0
00:00:15.465645 main     VirtualBox: object deleted

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

:        VBoxAuth
Remote desktop ExtPack:          
Log history count:               3
Default frontend:                
Default audio driver:            DirectSound
Autostart database path:         
Default Guest Additions ISO:     C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso
Logging Level:                   all
Proxy Mode:                      System
Proxy URL:                       

2021-04-17 19:59:34 (9128): 
Command: VBoxManage -q list hostinfo 
Exit Code: 0
Output:
Host Information:

Host time: 2021-04-17T18:59:34.248000000Z
Processor online count: 16
Processor count: 16
Processor online core count: 8
Processor core count: 8
Processor supports HW virtualization: no
Processor supports PAE: yes
Processor supports long mode: yes
Processor supports nested paging: no
Processor supports unrestricted guest: no
Processor supports nested HW virtualization: no
Processor#0 speed: unknown
Processor#0 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#1 speed: unknown
Processor#1 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#2 speed: unknown
Processor#2 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#3 speed: unknown
Processor#3 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#4 speed: unknown
Processor#4 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#5 speed: unknown
Processor#5 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#6 speed: unknown
Processor#6 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#7 speed: unknown
Processor#7 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#8 speed: unknown
Processor#8 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#9 speed: unknown
Processor#9 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#10 speed: unknown
Processor#10 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#11 speed: unknown
Processor#11 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#12 speed: unknown
Processor#12 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#13 speed: unknown
Processor#13 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#14 speed: unknown
Processor#14 description: AMD Ryzen 7 1800X Eight-Core Processor
Processor#15 speed: unknown
Processor#15 description: AMD Ryzen 7 1800X Eight-Core Processor
Memory size: 16313 MByte
Memory available: 7554 MByte
Operating system: Windows 10
Operating system version: 10.0.19041

2021-04-17 19:59:34 (9128): 
Command: VBoxManage -q showvminfo "boinc_e2520a5bcb5ba339" --machinereadable 
Exit Code: -2135228415
Output:
VBoxManage.exe: error: Could not find a registered machine named 'boinc_e2520a5bcb5ba339'
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown
VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2715 of file VBoxManageInfo.cpp

2021-04-17 19:59:34 (9128): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\11/vm_image.vdi" 
Exit Code: -2135228412
Output:
VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\11\vm_image.vdi' (VERR_FILE_NOT_FOUND)
VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp

2021-04-17 19:59:35 (9128): 
Command: VBoxManage -q createvm --name "boinc_e2520a5bcb5ba339" --basefolder "C:\ProgramData\BOINC\slots\11" --ostype "Linux26_64" --register
Exit Code: 0
Output:
Virtual machine 'boinc_e2520a5bcb5ba339' is created and registered.
UUID: 244a2e4f-bec7-4d19-994d-6fe112edd397
Settings file: 'C:\ProgramData\BOINC\slots\11\boinc_e2520a5bcb5ba339\boinc_e2520a5bcb5ba339.vbox'

2021-04-17 19:59:35 (9128): 
Command: VBoxManage -q modifyvm "boinc_e2520a5bcb5ba339" --description "08287007_40_0" 
Exit Code: 0
Output:

2021-04-17 19:59:35 (9128): 
Command: VBoxManage -q modifyvm "boinc_e2520a5bcb5ba339" --memory 3072 
Exit Code: 0
Output:

2021-04-17 19:59:36 (9128): 
Command: VBoxManage -q modifyvm "boinc_e2520a5bcb5ba339" --cpus 1 
Exit Code: 0
Output:

2021-04-17 19:59:36 (9128): 
Command: VBoxManage -q modifyvm "boinc_e2520a5bcb5ba339" --acpi on --ioapic on 
Exit Code: 0
Output:

2021-04-17 19:59:36 (9128): 
Command: VBoxManage -q modifyvm "boinc_e2520a5bcb5ba339" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2021-04-17 19:59:36 (9128): 
Command: VBoxManage -q modifyvm "boinc_e2520a5bcb5ba339" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2021-04-17 19:59:37 (9128): 
Command: VBoxManage -q modifyvm "boinc_e2520a5bcb5ba339" --cableconnected1 on 
Exit Code: 0
Output:

2021-04-17 19:59:37 (9128): 
Command: VBoxManage -q modifyvm "boinc_e2520a5bcb5ba339" --usb off 
Exit Code: 0
Output:

2021-04-17 19:59:37 (9128): 
Command: VBoxManage -q modifyvm "boinc_e2520a5bcb5ba339" --uart1 off --uart2 off 
Exit Code: 0
Output:

2021-04-17 19:59:38 (9128): 
Command: VBoxManage -q modifyvm "boinc_e2520a5bcb5ba339" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2021-04-17 19:59:38 (9128): 
Command: VBoxManage -q modifyvm "boinc_e2520a5bcb5ba339" --audio none 
Exit Code: 0
Output:

2021-04-17 19:59:38 (9128): 
Command: VBoxManage -q modifyvm "boinc_e2520a5bcb5ba339" --clipboard disabled 
Exit Code: 0
Output:

2021-04-17 19:59:38 (9128): 
Command: VBoxManage -q modifyvm "boinc_e2520a5bcb5ba339" --draganddrop disabled 
Exit Code: 0
Output:

2021-04-17 19:59:39 (9128): 
Command: VBoxManage -q storagectl "boinc_e2520a5bcb5ba339" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2021-04-17 19:59:39 (9128): 
Command: VBoxManage -q storageattach "boinc_e2520a5bcb5ba339" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\ProgramData\BOINC\slots\11/vm_isocontext.iso" 
Exit Code: 0
Output:

2021-04-17 19:59:39 (9128): 
Command: VBoxManage -q storageattach "boinc_e2520a5bcb5ba339" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2021-04-17 19:59:40 (9128): 
Command: VBoxManage -q bandwidthctl "boinc_e2520a5bcb5ba339" add "boinc_e2520a5bcb5ba339_net" --type network --limit 1024G 
Exit Code: 0
Output:

2021-04-17 19:59:40 (9128): 
Command: VBoxManage -q sharedfolder add "boinc_e2520a5bcb5ba339" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\11/shared"
Exit Code: 0
Output:

2021-04-17 19:59:42 (9128): 
Command: VBoxManage -q startvm "boinc_e2520a5bcb5ba339" --type headless
Exit Code: 1
Output:
Waiting for VM "boinc_e2520a5bcb5ba339" to power on...
VBoxManage.exe: error: The virtual machine 'boinc_e2520a5bcb5ba339' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\11\boinc_e2520a5bcb5ba339\Logs\VBoxHardening.log'
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine

2021-04-17 19:59:42 (9128): 
Command: VBoxManage -q snapshot "boinc_e2520a5bcb5ba339" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2021-04-17 19:59:43 (9128): 
Command: VBoxManage -q bandwidthctl "boinc_e2520a5bcb5ba339" remove "boinc_e2520a5bcb5ba339_net" 
Exit Code: 0
Output:

2021-04-17 19:59:43 (9128): 
Command: VBoxManage -q unregistervm "boinc_e2520a5bcb5ba339" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

2021-04-17 19:59:43 (9128): 
Command: VBoxManage -q closemedium dvd "C:\ProgramData\BOINC\slots\11/vm_isocontext.iso" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

19:59:49 (9128): called boinc_finish(1)

</stderr_txt>
]]>


©2024 COPYRIGHT 2017-2018 NCN