Task 10304678

Name 08281192_35_1
Workunit 7947051
Created 19 Apr 2021, 22:41:35 UTC
Sent 19 Apr 2021, 22:43:07 UTC
Report deadline 24 Apr 2021, 22:43:07 UTC
Received 19 Apr 2021, 22:50:08 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status -2147467259 (0x80004005) Unknown error code
Computer ID 10660
Run time 44 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 3.34 GFLOPS
Application version boinc2docker v1.14 (vbox64_mt)
windows_x86_64
Peak working set size 10.39 MB
Peak swap size 6.23 MB
Peak disk usage 499.00 MB

Stderr output

<core_client_version>7.16.11</core_client_version>
<![CDATA[
<message>
Unspecified error
 (0x80004005) - exit code 2147500037 (0x80004005)</message>
<stderr_txt>
2021-04-19 17:44:53 (17412): Detected: vboxwrapper 26202
2021-04-19 17:44:53 (17412): Detected: BOINC client v7.16.11
2021-04-19 17:44:56 (17412): Detected: VirtualBox VboxManage Interface (Version: 6.1.12)
2021-04-19 17:44:58 (17412): Create VM. (boinc_299818a1172dbc53, slot#0)
2021-04-19 17:44:58 (17412): Updating drive controller type and model for desired configuration.
2021-04-19 17:44:59 (17412): Setting Memory Size for VM. (3072MB)
2021-04-19 17:45:01 (17412): Setting CPU Count for VM. (1)
2021-04-19 17:45:02 (17412): Setting Chipset Options for VM.
2021-04-19 17:45:03 (17412): Setting Boot Options for VM.
2021-04-19 17:45:03 (17412): Setting Network Configuration for NAT.
2021-04-19 17:45:04 (17412): Enabling VM Network Access.
2021-04-19 17:45:05 (17412): Disabling USB Support for VM.
2021-04-19 17:45:06 (17412): Disabling COM Port Support for VM.
2021-04-19 17:45:06 (17412): Disabling LPT Port Support for VM.
2021-04-19 17:45:07 (17412): Disabling Audio Support for VM.
2021-04-19 17:45:08 (17412): Disabling Clipboard Support for VM.
2021-04-19 17:45:08 (17412): Disabling Drag and Drop Support for VM.
2021-04-19 17:45:09 (17412): Adding storage controller(s) to VM.
2021-04-19 17:45:10 (17412): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso)
2021-04-19 17:45:11 (17412): Adding VirtualBox Guest Additions to VM.
2021-04-19 17:45:13 (17412): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2021-04-19 17:45:14 (17412): Enabling shared directory for VM.
2021-04-19 17:45:15 (17412): Starting VM using VBoxManage interface. (boinc_299818a1172dbc53, slot#0)
2021-04-19 17:45:22 (17412): Error in start VM for VM: -2147467259
Command:
VBoxManage -q startvm "boinc_299818a1172dbc53" --type headless
Output:
Waiting for VM "boinc_299818a1172dbc53" to power on...
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole

2021-04-19 17:45:22 (17412): VM failed to start.
2021-04-19 17:45:22 (17412): Could not start 
2021-04-19 17:45:22 (17412): ERROR: VM failed to start
2021-04-19 17:45:23 (17412): Powering off VM.
2021-04-19 17:45:23 (17412): Deregistering VM. (boinc_299818a1172dbc53, slot#0)
2021-04-19 17:45:23 (17412): Removing network bandwidth throttle group from VM.
2021-04-19 17:45:23 (17412): Removing VM from VirtualBox.
2021-04-19 17:45:24 (17412): Removing virtual ISO 9660 disk from VirtualBox.

    Hypervisor System Log:

00:00:21.721290          Saving settings file "C:\Users\Dave's PC\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:21.788458          Saving settings file "C:\Users\Dave's PC\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:21.879829          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_309bce55eed36da5\boinc_309bce55eed36da5.vbox" with version "1.16-windows"
00:00:22.108716          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_49847633b23f3943\boinc_49847633b23f3943.vbox" with version "1.16-windows"
00:00:22.247513          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:22.251080          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:22.252059          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_309bce55eed36da5\boinc_309bce55eed36da5.vbox" with version "1.16-windows"
00:00:22.539823          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_309bce55eed36da5\boinc_309bce55eed36da5.vbox" with version "1.16-windows"
00:00:22.667367          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_49847633b23f3943\boinc_49847633b23f3943.vbox" with version "1.16-windows"
00:00:23.104713          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_309bce55eed36da5\boinc_309bce55eed36da5.vbox" with version "1.16-windows"
00:00:23.264674          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_49847633b23f3943\boinc_49847633b23f3943.vbox" with version "1.16-windows"
00:00:23.666733          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:23.669404          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:23.717204          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:23.740815          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_49847633b23f3943\boinc_49847633b23f3943.vbox" with version "1.16-windows"
00:00:24.189177          Launched VM: 64502144 pid: 9260 (0x242c) frontend: headless name: boinc_309bce55eed36da5
00:00:24.265428          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_49847633b23f3943\boinc_49847633b23f3943.vbox" with version "1.16-windows"
00:00:24.808696          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_49847633b23f3943\boinc_49847633b23f3943.vbox" with version "1.16-windows"
00:00:25.392054          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:25.404108          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:25.404394          Saving settings file "C:\Users\Dave's PC\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:25.479661          Saving settings file "C:\Users\Dave's PC\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:25.586737          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_49847633b23f3943\boinc_49847633b23f3943.vbox" with version "1.16-windows"
00:00:26.120381          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:26.122150          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:26.128768          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_49847633b23f3943\boinc_49847633b23f3943.vbox" with version "1.16-windows"
00:00:26.639624          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_49847633b23f3943\boinc_49847633b23f3943.vbox" with version "1.16-windows"
00:00:27.189214          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_49847633b23f3943\boinc_49847633b23f3943.vbox" with version "1.16-windows"
00:00:27.757887          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:27.758169          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:27.808660          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:28.289237          Launched VM: 64299936 pid: 12448 (0x30a0) frontend: headless name: boinc_49847633b23f3943
00:00:28.316465          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_299818a1172dbc53\boinc_299818a1172dbc53.vbox" with version "1.16-windows"
00:00:28.811874          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:29.045882          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_299818a1172dbc53\boinc_299818a1172dbc53.vbox" with version "1.16-windows"
00:00:29.331480          Saving settings file "C:\Users\Dave's PC\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:31.835895          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_309bce55eed36da5\boinc_309bce55eed36da5.vbox" with version "1.16-windows"
00:00:32.193240          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:32.470616          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_309bce55eed36da5\boinc_309bce55eed36da5.vbox" with version "1.16-windows"
00:00:33.006535          Saving settings file "C:\Users\Dave's PC\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:35.661369          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_49847633b23f3943\boinc_49847633b23f3943.vbox" with version "1.16-windows"
00:00:35.997359          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:36.222134          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_49847633b23f3943\boinc_49847633b23f3943.vbox" with version "1.16-windows"
00:00:36.774295          Saving settings file "C:\Users\Dave's PC\.VirtualBox\VirtualBox.xml" with version "1.12-windows"

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

count:          255
Maximum Devices per SAS Port:    1
Maximum NVMe PIIX3 Controllers:  1
Maximum NVMe ICH9 Controllers:   8
Maximum NVMe Port count:         255
Maximum Devices per NVMe Port:   1
Maximum virtio-scsi PIIX3 Controllers:  1
Maximum virtio-scsi ICH9 Controllers:   8
Maximum virtio-scsi Port count:         256
Maximum Devices per virtio-scsi Port:   1
Maximum PIIX3 Floppy Controllers:1
Maximum ICH9 Floppy Controllers: 1
Maximum Floppy Port count:       1
Maximum Devices per Floppy Port: 2
Default machine folder:          C:\Users\Dave's PC\VirtualBox VMs
Raw-mode Supported:              no
Exclusive HW virtualization use: off
Default hard disk format:        VDI
VRDE auth library:               VBoxAuth
Webservice auth. library:        VBoxAuth
Remote desktop ExtPack:          
Log history count:               3
Default frontend:                
Default audio driver:            DirectSound
Autostart database path:         
Default Guest Additions ISO:     C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso
Logging Level:                   all
Proxy Mode:                      System
Proxy URL:                       

2021-04-19 17:44:57 (17412): 
Command: VBoxManage -q list hostinfo 
Exit Code: 0
Output:
Host Information:

Host time: 2021-04-19T22:44:57.166000000Z
Processor online count: 8
Processor count: 8
Processor online core count: 4
Processor core count: 4
Processor supports HW virtualization: no
Processor supports PAE: yes
Processor supports long mode: yes
Processor supports nested paging: no
Processor supports unrestricted guest: no
Processor supports nested HW virtualization: no
Processor#0 speed: unknown
Processor#0 description: Intel(R) Core(TM) i5-8250U CPU @ 1.60GHz
Processor#1 speed: unknown
Processor#1 description: Intel(R) Core(TM) i5-8250U CPU @ 1.60GHz
Processor#2 speed: unknown
Processor#2 description: Intel(R) Core(TM) i5-8250U CPU @ 1.60GHz
Processor#3 speed: unknown
Processor#3 description: Intel(R) Core(TM) i5-8250U CPU @ 1.60GHz
Processor#4 speed: unknown
Processor#4 description: Intel(R) Core(TM) i5-8250U CPU @ 1.60GHz
Processor#5 speed: unknown
Processor#5 description: Intel(R) Core(TM) i5-8250U CPU @ 1.60GHz
Processor#6 speed: unknown
Processor#6 description: Intel(R) Core(TM) i5-8250U CPU @ 1.60GHz
Processor#7 speed: unknown
Processor#7 description: Intel(R) Core(TM) i5-8250U CPU @ 1.60GHz
Memory size: 12168 MByte
Memory available: 6248 MByte
Operating system: Windows 10
Operating system version: 10.0.19041

2021-04-19 17:44:57 (17412): 
Command: VBoxManage -q showvminfo "boinc_299818a1172dbc53" --machinereadable 
Exit Code: -2135228415
Output:
VBoxManage.exe: error: Could not find a registered machine named 'boinc_299818a1172dbc53'
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown
VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2715 of file VBoxManageInfo.cpp

2021-04-19 17:44:58 (17412): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\0/vm_image.vdi" 
Exit Code: -2135228412
Output:
VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\0\vm_image.vdi' (VERR_FILE_NOT_FOUND)
VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp

2021-04-19 17:44:59 (17412): 
Command: VBoxManage -q createvm --name "boinc_299818a1172dbc53" --basefolder "C:\ProgramData\BOINC\slots\0" --ostype "Linux26_64" --register
Exit Code: 0
Output:
Virtual machine 'boinc_299818a1172dbc53' is created and registered.
UUID: ef85ea41-594a-4e38-8d75-0da99f13b248
Settings file: 'C:\ProgramData\BOINC\slots\0\boinc_299818a1172dbc53\boinc_299818a1172dbc53.vbox'

2021-04-19 17:44:59 (17412): 
Command: VBoxManage -q modifyvm "boinc_299818a1172dbc53" --description "08281192_35_1" 
Exit Code: 0
Output:

2021-04-19 17:45:01 (17412): 
Command: VBoxManage -q modifyvm "boinc_299818a1172dbc53" --memory 3072 
Exit Code: 0
Output:

2021-04-19 17:45:02 (17412): 
Command: VBoxManage -q modifyvm "boinc_299818a1172dbc53" --cpus 1 
Exit Code: 0
Output:

2021-04-19 17:45:03 (17412): 
Command: VBoxManage -q modifyvm "boinc_299818a1172dbc53" --acpi on --ioapic on 
Exit Code: 0
Output:

2021-04-19 17:45:03 (17412): 
Command: VBoxManage -q modifyvm "boinc_299818a1172dbc53" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2021-04-19 17:45:04 (17412): 
Command: VBoxManage -q modifyvm "boinc_299818a1172dbc53" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2021-04-19 17:45:05 (17412): 
Command: VBoxManage -q modifyvm "boinc_299818a1172dbc53" --cableconnected1 on 
Exit Code: 0
Output:

2021-04-19 17:45:06 (17412): 
Command: VBoxManage -q modifyvm "boinc_299818a1172dbc53" --usb off 
Exit Code: 0
Output:

2021-04-19 17:45:06 (17412): 
Command: VBoxManage -q modifyvm "boinc_299818a1172dbc53" --uart1 off --uart2 off 
Exit Code: 0
Output:

2021-04-19 17:45:07 (17412): 
Command: VBoxManage -q modifyvm "boinc_299818a1172dbc53" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2021-04-19 17:45:08 (17412): 
Command: VBoxManage -q modifyvm "boinc_299818a1172dbc53" --audio none 
Exit Code: 0
Output:

2021-04-19 17:45:08 (17412): 
Command: VBoxManage -q modifyvm "boinc_299818a1172dbc53" --clipboard disabled 
Exit Code: 0
Output:

2021-04-19 17:45:09 (17412): 
Command: VBoxManage -q modifyvm "boinc_299818a1172dbc53" --draganddrop disabled 
Exit Code: 0
Output:

2021-04-19 17:45:10 (17412): 
Command: VBoxManage -q storagectl "boinc_299818a1172dbc53" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2021-04-19 17:45:11 (17412): 
Command: VBoxManage -q storageattach "boinc_299818a1172dbc53" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\ProgramData\BOINC\slots\0/vm_isocontext.iso" 
Exit Code: 0
Output:

2021-04-19 17:45:13 (17412): 
Command: VBoxManage -q storageattach "boinc_299818a1172dbc53" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2021-04-19 17:45:14 (17412): 
Command: VBoxManage -q bandwidthctl "boinc_299818a1172dbc53" add "boinc_299818a1172dbc53_net" --type network --limit 1024G 
Exit Code: 0
Output:

2021-04-19 17:45:14 (17412): 
Command: VBoxManage -q sharedfolder add "boinc_299818a1172dbc53" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\0/shared"
Exit Code: 0
Output:

2021-04-19 17:45:22 (17412): 
Command: VBoxManage -q startvm "boinc_299818a1172dbc53" --type headless
Exit Code: -2147467259
Output:
Waiting for VM "boinc_299818a1172dbc53" to power on...
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole

2021-04-19 17:45:23 (17412): 
Command: VBoxManage -q snapshot "boinc_299818a1172dbc53" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2021-04-19 17:45:23 (17412): 
Command: VBoxManage -q bandwidthctl "boinc_299818a1172dbc53" remove "boinc_299818a1172dbc53_net" 
Exit Code: 0
Output:

2021-04-19 17:45:24 (17412): 
Command: VBoxManage -q unregistervm "boinc_299818a1172dbc53" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

2021-04-19 17:45:24 (17412): 
Command: VBoxManage -q closemedium dvd "C:\ProgramData\BOINC\slots\0/vm_isocontext.iso" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

17:45:35 (17412): called boinc_finish(-2147467259)

</stderr_txt>
]]>


©2024 COPYRIGHT 2017-2018 NCN