Name | 08281195_17_1 |
Workunit | 7947082 |
Created | 19 Apr 2021, 22:42:05 UTC |
Sent | 19 Apr 2021, 22:43:07 UTC |
Report deadline | 24 Apr 2021, 22:43:07 UTC |
Received | 19 Apr 2021, 22:56:00 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | -2147467259 (0x80004005) Unknown error code |
Computer ID | 10660 |
Run time | 32 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 3.34 GFLOPS |
Application version | boinc2docker v1.14 (vbox64_mt) windows_x86_64 |
Peak working set size | 10.89 MB |
Peak swap size | 6.23 MB |
Peak disk usage | 507.18 MB |
<core_client_version>7.16.11</core_client_version> <![CDATA[ <message> Unspecified error (0x80004005) - exit code 2147500037 (0x80004005)</message> <stderr_txt> 2021-04-19 17:51:57 (10140): Detected: vboxwrapper 26202 2021-04-19 17:51:57 (10140): Detected: BOINC client v7.16.11 2021-04-19 17:51:57 (10140): Detected: VirtualBox VboxManage Interface (Version: 6.1.12) 2021-04-19 17:51:58 (10140): Create VM. (boinc_e83a5166787865e2, slot#1) 2021-04-19 17:51:58 (10140): Updating drive controller type and model for desired configuration. 2021-04-19 17:52:00 (10140): Setting Memory Size for VM. (3072MB) 2021-04-19 17:52:01 (10140): Setting CPU Count for VM. (1) 2021-04-19 17:52:02 (10140): Setting Chipset Options for VM. 2021-04-19 17:52:03 (10140): Setting Boot Options for VM. 2021-04-19 17:52:04 (10140): Setting Network Configuration for NAT. 2021-04-19 17:52:05 (10140): Enabling VM Network Access. 2021-04-19 17:52:05 (10140): Disabling USB Support for VM. 2021-04-19 17:52:06 (10140): Disabling COM Port Support for VM. 2021-04-19 17:52:06 (10140): Disabling LPT Port Support for VM. 2021-04-19 17:52:07 (10140): Disabling Audio Support for VM. 2021-04-19 17:52:07 (10140): Disabling Clipboard Support for VM. 2021-04-19 17:52:08 (10140): Disabling Drag and Drop Support for VM. 2021-04-19 17:52:08 (10140): Adding storage controller(s) to VM. 2021-04-19 17:52:09 (10140): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso) 2021-04-19 17:52:09 (10140): Adding VirtualBox Guest Additions to VM. 2021-04-19 17:52:10 (10140): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2021-04-19 17:52:10 (10140): Enabling shared directory for VM. 2021-04-19 17:52:11 (10140): Starting VM using VBoxManage interface. (boinc_e83a5166787865e2, slot#1) 2021-04-19 17:52:19 (10140): Error in start VM for VM: -2147467259 Command: VBoxManage -q startvm "boinc_e83a5166787865e2" --type headless Output: Waiting for VM "boinc_e83a5166787865e2" to power on... VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2021-04-19 17:52:19 (10140): VM failed to start. 2021-04-19 17:52:19 (10140): Could not start 2021-04-19 17:52:19 (10140): ERROR: VM failed to start 2021-04-19 17:52:19 (10140): Powering off VM. 2021-04-19 17:52:19 (10140): Deregistering VM. (boinc_e83a5166787865e2, slot#1) 2021-04-19 17:52:19 (10140): Removing network bandwidth throttle group from VM. 2021-04-19 17:52:20 (10140): Removing VM from VirtualBox. 2021-04-19 17:52:20 (10140): Removing virtual ISO 9660 disk from VirtualBox. Hypervisor System Log: 00:00:17.473302 Saving settings file "C:\Users\Dave's PC\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:17.515185 Saving settings file "C:\Users\Dave's PC\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:17.555117 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_e5cfafa3d6b18ec0\boinc_e5cfafa3d6b18ec0.vbox" with version "1.16-windows" 00:00:17.939386 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:17.940202 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_e83a5166787865e2\boinc_e83a5166787865e2.vbox" with version "1.16-windows" 00:00:17.941540 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:17.944808 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_e5cfafa3d6b18ec0\boinc_e5cfafa3d6b18ec0.vbox" with version "1.16-windows" 00:00:18.456031 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_e83a5166787865e2\boinc_e83a5166787865e2.vbox" with version "1.16-windows" 00:00:18.518523 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_e5cfafa3d6b18ec0\boinc_e5cfafa3d6b18ec0.vbox" with version "1.16-windows" 00:00:18.739874 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_e83a5166787865e2\boinc_e83a5166787865e2.vbox" with version "1.16-windows" 00:00:19.051452 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_e5cfafa3d6b18ec0\boinc_e5cfafa3d6b18ec0.vbox" with version "1.16-windows" 00:00:19.264667 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:19.298647 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:19.299240 Saving settings file "C:\Users\Dave's PC\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:19.379445 Saving settings file "C:\Users\Dave's PC\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:19.417995 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_e83a5166787865e2\boinc_e83a5166787865e2.vbox" with version "1.16-windows" 00:00:19.607074 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:19.607421 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:19.659704 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:19.839411 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:19.840229 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:19.841271 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_e83a5166787865e2\boinc_e83a5166787865e2.vbox" with version "1.16-windows" 00:00:20.145624 Launched VM: 68555888 pid: 9520 (0x2530) frontend: headless name: boinc_e5cfafa3d6b18ec0 00:00:20.157748 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_e83a5166787865e2\boinc_e83a5166787865e2.vbox" with version "1.16-windows" 00:00:20.684323 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_e83a5166787865e2\boinc_e83a5166787865e2.vbox" with version "1.16-windows" 00:00:21.229430 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:21.231506 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:21.288246 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:21.760772 Launched VM: 68446912 pid: 5028 (0x13a4) frontend: headless name: boinc_e83a5166787865e2 00:00:25.133848 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_e3860262e74e17d0\boinc_e3860262e74e17d0.vbox" with version "1.16-windows" 00:00:25.519823 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:25.749066 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_e3860262e74e17d0\boinc_e3860262e74e17d0.vbox" with version "1.16-windows" 00:00:26.259031 Saving settings file "C:\Users\Dave's PC\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:27.606296 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_e5cfafa3d6b18ec0\boinc_e5cfafa3d6b18ec0.vbox" with version "1.16-windows" 00:00:27.926590 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:28.188823 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_e5cfafa3d6b18ec0\boinc_e5cfafa3d6b18ec0.vbox" with version "1.16-windows" 00:00:28.420292 Saving settings file "C:\Users\Dave's PC\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:29.255040 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_e83a5166787865e2\boinc_e83a5166787865e2.vbox" with version "1.16-windows" 00:00:29.558423 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:29.783934 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_e83a5166787865e2\boinc_e83a5166787865e2.vbox" with version "1.16-windows" 00:00:30.316394 Saving settings file "C:\Users\Dave's PC\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:35.620862 main VirtualBox: object deletion starts 00:00:35.621782 main HostDnsMonitor: shutting down ... 00:00:35.621880 main HostDnsMonitor: shut down 00:00:35.624869 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:35.625185 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: count: 255 Maximum Devices per SAS Port: 1 Maximum NVMe PIIX3 Controllers: 1 Maximum NVMe ICH9 Controllers: 8 Maximum NVMe Port count: 255 Maximum Devices per NVMe Port: 1 Maximum virtio-scsi PIIX3 Controllers: 1 Maximum virtio-scsi ICH9 Controllers: 8 Maximum virtio-scsi Port count: 256 Maximum Devices per virtio-scsi Port: 1 Maximum PIIX3 Floppy Controllers:1 Maximum ICH9 Floppy Controllers: 1 Maximum Floppy Port count: 1 Maximum Devices per Floppy Port: 2 Default machine folder: C:\Users\Dave's PC\VirtualBox VMs Raw-mode Supported: no Exclusive HW virtualization use: off Default hard disk format: VDI VRDE auth library: VBoxAuth Webservice auth. library: VBoxAuth Remote desktop ExtPack: Log history count: 3 Default frontend: Default audio driver: DirectSound Autostart database path: Default Guest Additions ISO: C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso Logging Level: all Proxy Mode: System Proxy URL: 2021-04-19 17:51:58 (10140): Command: VBoxManage -q list hostinfo Exit Code: 0 Output: Host Information: Host time: 2021-04-19T22:51:57.896000000Z Processor online count: 8 Processor count: 8 Processor online core count: 4 Processor core count: 4 Processor supports HW virtualization: no Processor supports PAE: yes Processor supports long mode: yes Processor supports nested paging: no Processor supports unrestricted guest: no Processor supports nested HW virtualization: no Processor#0 speed: unknown Processor#0 description: Intel(R) Core(TM) i5-8250U CPU @ 1.60GHz Processor#1 speed: unknown Processor#1 description: Intel(R) Core(TM) i5-8250U CPU @ 1.60GHz Processor#2 speed: unknown Processor#2 description: Intel(R) Core(TM) i5-8250U CPU @ 1.60GHz Processor#3 speed: unknown Processor#3 description: Intel(R) Core(TM) i5-8250U CPU @ 1.60GHz Processor#4 speed: unknown Processor#4 description: Intel(R) Core(TM) i5-8250U CPU @ 1.60GHz Processor#5 speed: unknown Processor#5 description: Intel(R) Core(TM) i5-8250U CPU @ 1.60GHz Processor#6 speed: unknown Processor#6 description: Intel(R) Core(TM) i5-8250U CPU @ 1.60GHz Processor#7 speed: unknown Processor#7 description: Intel(R) Core(TM) i5-8250U CPU @ 1.60GHz Memory size: 12168 MByte Memory available: 6249 MByte Operating system: Windows 10 Operating system version: 10.0.19041 2021-04-19 17:51:58 (10140): Command: VBoxManage -q showvminfo "boinc_e83a5166787865e2" --machinereadable Exit Code: -2135228415 Output: VBoxManage.exe: error: Could not find a registered machine named 'boinc_e83a5166787865e2' VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2715 of file VBoxManageInfo.cpp 2021-04-19 17:51:58 (10140): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\1/vm_image.vdi" Exit Code: -2135228412 Output: VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\1\vm_image.vdi' (VERR_FILE_NOT_FOUND) VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp 2021-04-19 17:52:00 (10140): Command: VBoxManage -q createvm --name "boinc_e83a5166787865e2" --basefolder "C:\ProgramData\BOINC\slots\1" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_e83a5166787865e2' is created and registered. UUID: 5c7e52c8-d782-44e0-ad91-3ac6c744f677 Settings file: 'C:\ProgramData\BOINC\slots\1\boinc_e83a5166787865e2\boinc_e83a5166787865e2.vbox' 2021-04-19 17:52:00 (10140): Command: VBoxManage -q modifyvm "boinc_e83a5166787865e2" --description "08281195_17_1" Exit Code: 0 Output: 2021-04-19 17:52:01 (10140): Command: VBoxManage -q modifyvm "boinc_e83a5166787865e2" --memory 3072 Exit Code: 0 Output: 2021-04-19 17:52:02 (10140): Command: VBoxManage -q modifyvm "boinc_e83a5166787865e2" --cpus 1 Exit Code: 0 Output: 2021-04-19 17:52:03 (10140): Command: VBoxManage -q modifyvm "boinc_e83a5166787865e2" --acpi on --ioapic on Exit Code: 0 Output: 2021-04-19 17:52:04 (10140): Command: VBoxManage -q modifyvm "boinc_e83a5166787865e2" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2021-04-19 17:52:05 (10140): Command: VBoxManage -q modifyvm "boinc_e83a5166787865e2" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2021-04-19 17:52:05 (10140): Command: VBoxManage -q modifyvm "boinc_e83a5166787865e2" --cableconnected1 on Exit Code: 0 Output: 2021-04-19 17:52:06 (10140): Command: VBoxManage -q modifyvm "boinc_e83a5166787865e2" --usb off Exit Code: 0 Output: 2021-04-19 17:52:06 (10140): Command: VBoxManage -q modifyvm "boinc_e83a5166787865e2" --uart1 off --uart2 off Exit Code: 0 Output: 2021-04-19 17:52:07 (10140): Command: VBoxManage -q modifyvm "boinc_e83a5166787865e2" --lpt1 off --lpt2 off Exit Code: 0 Output: 2021-04-19 17:52:07 (10140): Command: VBoxManage -q modifyvm "boinc_e83a5166787865e2" --audio none Exit Code: 0 Output: 2021-04-19 17:52:08 (10140): Command: VBoxManage -q modifyvm "boinc_e83a5166787865e2" --clipboard disabled Exit Code: 0 Output: 2021-04-19 17:52:08 (10140): Command: VBoxManage -q modifyvm "boinc_e83a5166787865e2" --draganddrop disabled Exit Code: 0 Output: 2021-04-19 17:52:09 (10140): Command: VBoxManage -q storagectl "boinc_e83a5166787865e2" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2021-04-19 17:52:09 (10140): Command: VBoxManage -q storageattach "boinc_e83a5166787865e2" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\ProgramData\BOINC\slots\1/vm_isocontext.iso" Exit Code: 0 Output: 2021-04-19 17:52:10 (10140): Command: VBoxManage -q storageattach "boinc_e83a5166787865e2" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2021-04-19 17:52:10 (10140): Command: VBoxManage -q bandwidthctl "boinc_e83a5166787865e2" add "boinc_e83a5166787865e2_net" --type network --limit 1024G Exit Code: 0 Output: 2021-04-19 17:52:11 (10140): Command: VBoxManage -q sharedfolder add "boinc_e83a5166787865e2" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\1/shared" Exit Code: 0 Output: 2021-04-19 17:52:19 (10140): Command: VBoxManage -q startvm "boinc_e83a5166787865e2" --type headless Exit Code: -2147467259 Output: Waiting for VM "boinc_e83a5166787865e2" to power on... VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2021-04-19 17:52:19 (10140): Command: VBoxManage -q snapshot "boinc_e83a5166787865e2" list Exit Code: -108 Output: This machine does not have any snapshots 2021-04-19 17:52:20 (10140): Command: VBoxManage -q bandwidthctl "boinc_e83a5166787865e2" remove "boinc_e83a5166787865e2_net" Exit Code: 0 Output: 2021-04-19 17:52:20 (10140): Command: VBoxManage -q unregistervm "boinc_e83a5166787865e2" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 2021-04-19 17:52:20 (10140): Command: VBoxManage -q closemedium dvd "C:\ProgramData\BOINC\slots\1/vm_isocontext.iso" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 17:52:26 (10140): called boinc_finish(-2147467259) </stderr_txt> ]]>
©2025 COPYRIGHT 2017-2018 NCN