Name | 08281192_27_2 |
Workunit | 7947043 |
Created | 19 Apr 2021, 23:04:45 UTC |
Sent | 19 Apr 2021, 23:06:08 UTC |
Report deadline | 24 Apr 2021, 23:06:08 UTC |
Received | 20 Apr 2021, 10:10:44 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | -2147467259 (0x80004005) Unknown error code |
Computer ID | 10553 |
Run time | 21 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 2.82 GFLOPS |
Application version | boinc2docker v1.14 (vbox64_mt) windows_x86_64 |
Peak working set size | 10.60 MB |
Peak swap size | 6.45 MB |
Peak disk usage | 499.02 MB |
<core_client_version>7.16.11</core_client_version> <![CDATA[ <message> Erreur non sp�cifi�e (0x80004005) - exit code 2147500037 (0x80004005)</message> <stderr_txt> 2021-04-20 11:12:08 (14000): Detected: vboxwrapper 26202 2021-04-20 11:12:08 (14000): Detected: BOINC client v7.16.11 2021-04-20 11:12:09 (14000): Detected: VirtualBox VboxManage Interface (Version: 6.1.12) 2021-04-20 11:12:10 (14000): Create VM. (boinc_eeaccc3abf1e02d6, slot#2) 2021-04-20 11:12:10 (14000): Updating drive controller type and model for desired configuration. 2021-04-20 11:12:10 (14000): Setting Memory Size for VM. (3072MB) 2021-04-20 11:12:10 (14000): Setting CPU Count for VM. (1) 2021-04-20 11:12:11 (14000): Setting Chipset Options for VM. 2021-04-20 11:12:11 (14000): Setting Boot Options for VM. 2021-04-20 11:12:11 (14000): Setting Network Configuration for NAT. 2021-04-20 11:12:12 (14000): Enabling VM Network Access. 2021-04-20 11:12:12 (14000): Disabling USB Support for VM. 2021-04-20 11:12:12 (14000): Disabling COM Port Support for VM. 2021-04-20 11:12:12 (14000): Disabling LPT Port Support for VM. 2021-04-20 11:12:13 (14000): Disabling Audio Support for VM. 2021-04-20 11:12:13 (14000): Disabling Clipboard Support for VM. 2021-04-20 11:12:13 (14000): Disabling Drag and Drop Support for VM. 2021-04-20 11:12:13 (14000): Adding storage controller(s) to VM. 2021-04-20 11:12:14 (14000): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso) 2021-04-20 11:12:14 (14000): Adding VirtualBox Guest Additions to VM. 2021-04-20 11:12:14 (14000): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2021-04-20 11:12:15 (14000): Enabling shared directory for VM. 2021-04-20 11:12:15 (14000): Starting VM using VBoxManage interface. (boinc_eeaccc3abf1e02d6, slot#2) 2021-04-20 11:12:20 (14000): Error in start VM for VM: -2147467259 Command: VBoxManage -q startvm "boinc_eeaccc3abf1e02d6" --type headless Output: Waiting for VM "boinc_eeaccc3abf1e02d6" to power on... VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2021-04-20 11:12:20 (14000): VM failed to start. 2021-04-20 11:12:20 (14000): Could not start 2021-04-20 11:12:20 (14000): ERROR: VM failed to start 2021-04-20 11:12:20 (14000): Powering off VM. 2021-04-20 11:12:20 (14000): Deregistering VM. (boinc_eeaccc3abf1e02d6, slot#2) 2021-04-20 11:12:20 (14000): Removing network bandwidth throttle group from VM. 2021-04-20 11:12:20 (14000): Removing VM from VirtualBox. 2021-04-20 11:12:20 (14000): Removing virtual ISO 9660 disk from VirtualBox. Hypervisor System Log: 00:00:00.215929 usbLibGetDevices: Found 3 USB devices, 0 captured 00:00:00.216066 USB: Unknown USB device detected (idVendor: 0x8087, idProduct: 0x07dc) 00:00:00.390938 HostDnsMonitor: initializing 00:00:00.402728 HostDnsMonitor: updating information 00:00:00.402766 HostDnsMonitor: old information 00:00:00.402768 no server entries 00:00:00.402769 no domain set 00:00:00.402769 no search string entries 00:00:00.402770 HostDnsMonitor: new information 00:00:00.402771 server 1: 208.91.112.53 00:00:00.402772 server 2: 208.91.112.52 00:00:00.402773 no domain set 00:00:00.402773 no search string entries 00:00:00.504889 SUPR0QueryVTCaps -> VERR_VMX_MSR_ALL_VMX_DISABLED 00:00:00.506009 VD: VDInit finished with VINF_SUCCESS 00:00:00.508298 VirtualBox: object created 00:00:00.965635 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={Could not find a registered machine named 'boinc_eeaccc3abf1e02d6'}, preserve=false aResultDetail=0 00:00:01.224726 ERROR [COM]: aRC=VBOX_E_FILE_ERROR (0x80bb0004) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Could not find file for the medium 'C:\ProgramData\BOINC\slots\2\vm_image.vdi' (VERR_FILE_NOT_FOUND)}, preserve=false aResultDetail=-102 00:00:01.501373 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_eeaccc3abf1e02d6\boinc_eeaccc3abf1e02d6.vbox" with version "1.16-windows" 00:00:01.506907 Saving settings file "C:\Users\chap\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:01.789303 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_eeaccc3abf1e02d6\boinc_eeaccc3abf1e02d6.vbox" with version "1.16-windows" 00:00:02.044847 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_eeaccc3abf1e02d6\boinc_eeaccc3abf1e02d6.vbox" with version "1.16-windows" 00:00:02.309194 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_eeaccc3abf1e02d6\boinc_eeaccc3abf1e02d6.vbox" with version "1.16-windows" 00:00:02.588872 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_eeaccc3abf1e02d6\boinc_eeaccc3abf1e02d6.vbox" with version "1.16-windows" 00:00:02.848667 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_eeaccc3abf1e02d6\boinc_eeaccc3abf1e02d6.vbox" with version "1.16-windows" 00:00:03.110124 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_eeaccc3abf1e02d6\boinc_eeaccc3abf1e02d6.vbox" with version "1.16-windows" 00:00:03.379557 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_eeaccc3abf1e02d6\boinc_eeaccc3abf1e02d6.vbox" with version "1.16-windows" 00:00:03.643469 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_eeaccc3abf1e02d6\boinc_eeaccc3abf1e02d6.vbox" with version "1.16-windows" 00:00:03.920884 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_eeaccc3abf1e02d6\boinc_eeaccc3abf1e02d6.vbox" with version "1.16-windows" 00:00:04.197116 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_eeaccc3abf1e02d6\boinc_eeaccc3abf1e02d6.vbox" with version "1.16-windows" 00:00:04.468522 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_eeaccc3abf1e02d6\boinc_eeaccc3abf1e02d6.vbox" with version "1.16-windows" 00:00:04.739412 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_eeaccc3abf1e02d6\boinc_eeaccc3abf1e02d6.vbox" with version "1.16-windows" 00:00:05.010151 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_eeaccc3abf1e02d6\boinc_eeaccc3abf1e02d6.vbox" with version "1.16-windows" 00:00:05.283714 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_eeaccc3abf1e02d6\boinc_eeaccc3abf1e02d6.vbox" with version "1.16-windows" 00:00:05.555332 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:05.561264 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:05.561555 Saving settings file "C:\Users\chap\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:05.567127 Saving settings file "C:\Users\chap\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:05.572132 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_eeaccc3abf1e02d6\boinc_eeaccc3abf1e02d6.vbox" with version "1.16-windows" 00:00:05.826760 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:05.829198 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:05.829446 Saving settings file "C:\Users\chap\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:05.849252 Saving settings file "C:\Users\chap\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:05.857508 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_eeaccc3abf1e02d6\boinc_eeaccc3abf1e02d6.vbox" with version "1.16-windows" 00:00:06.094057 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_eeaccc3abf1e02d6\boinc_eeaccc3abf1e02d6.vbox" with version "1.16-windows" 00:00:06.373164 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_eeaccc3abf1e02d6\boinc_eeaccc3abf1e02d6.vbox" with version "1.16-windows" 00:00:06.644364 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:06.644562 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:06.658430 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:06.907185 Launched VM: 59948848 pid: 17360 (0x43d0) frontend: headless name: boinc_eeaccc3abf1e02d6 00:00:11.500204 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_eeaccc3abf1e02d6\boinc_eeaccc3abf1e02d6.vbox" with version "1.16-windows" 00:00:11.628293 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:11.720414 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_eeaccc3abf1e02d6\boinc_eeaccc3abf1e02d6.vbox" with version "1.16-windows" 00:00:12.016072 Saving settings file "C:\Users\chap\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:17.293623 main VirtualBox: object deletion starts 00:00:17.294819 main HostDnsMonitor: shutting down ... 00:00:17.294920 main HostDnsMonitor: shut down 00:00:17.297541 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:17.297925 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: 2 Maximum PIIX3 SATA Controllers: 1 Maximum ICH9 SATA Controllers: 8 Maximum SATA Port count: 30 Maximum Devices per SATA Port: 1 Maximum PIIX3 SCSI Controllers: 1 Maximum ICH9 SCSI Controllers: 8 Maximum SCSI Port count: 16 Maximum Devices per SCSI Port: 1 Maximum SAS PIIX3 Controllers: 1 Maximum SAS ICH9 Controllers: 8 Maximum SAS Port count: 255 Maximum Devices per SAS Port: 1 Maximum NVMe PIIX3 Controllers: 1 Maximum NVMe ICH9 Controllers: 8 Maximum NVMe Port count: 255 Maximum Devices per NVMe Port: 1 Maximum virtio-scsi PIIX3 Controllers: 1 Maximum virtio-scsi ICH9 Controllers: 8 Maximum virtio-scsi Port count: 256 Maximum Devices per virtio-scsi Port: 1 Maximum PIIX3 Floppy Controllers:1 Maximum ICH9 Floppy Controllers: 1 Maximum Floppy Port count: 1 Maximum Devices per Floppy Port: 2 Default machine folder: C:\Users\chap\VirtualBox VMs Raw-mode Supported: no Exclusive HW virtualization use: off Default hard disk format: VDI VRDE auth library: VBoxAuth Webservice auth. library: VBoxAuth Remote desktop ExtPack: Log history count: 3 Default frontend: Default audio driver: DirectSound Autostart database path: Default Guest Additions ISO: C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso Logging Level: all Proxy Mode: System Proxy URL: 2021-04-20 11:12:09 (14000): Command: VBoxManage -q list hostinfo Exit Code: 0 Output: Host Information: Host time: 2021-04-20T09:12:09.450000000Z Processor online count: 4 Processor count: 4 Processor online core count: 2 Processor core count: 2 Processor supports HW virtualization: no Processor supports PAE: yes Processor supports long mode: yes Processor supports nested paging: no Processor supports unrestricted guest: no Processor supports nested HW virtualization: no Processor#0 speed: unknown Processor#0 description: Intel(R) Core(TM) i5-4300U CPU @ 1.90GHz Processor#1 speed: unknown Processor#1 description: Intel(R) Core(TM) i5-4300U CPU @ 1.90GHz Processor#2 speed: unknown Processor#2 description: Intel(R) Core(TM) i5-4300U CPU @ 1.90GHz Processor#3 speed: unknown Processor#3 description: Intel(R) Core(TM) i5-4300U CPU @ 1.90GHz Memory size: 7879 MByte Memory available: 2572 MByte Operating system: Windows 10 Operating system version: 10.0.17763 2021-04-20 11:12:09 (14000): Command: VBoxManage -q showvminfo "boinc_eeaccc3abf1e02d6" --machinereadable Exit Code: -2135228415 Output: VBoxManage.exe: error: Could not find a registered machine named 'boinc_eeaccc3abf1e02d6' VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2715 of file VBoxManageInfo.cpp 2021-04-20 11:12:10 (14000): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\2/vm_image.vdi" Exit Code: -2135228412 Output: VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\2\vm_image.vdi' (VERR_FILE_NOT_FOUND) VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp 2021-04-20 11:12:10 (14000): Command: VBoxManage -q createvm --name "boinc_eeaccc3abf1e02d6" --basefolder "C:\ProgramData\BOINC\slots\2" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_eeaccc3abf1e02d6' is created and registered. UUID: 23374f30-bdf3-4b0c-b41d-457292bff3de Settings file: 'C:\ProgramData\BOINC\slots\2\boinc_eeaccc3abf1e02d6\boinc_eeaccc3abf1e02d6.vbox' 2021-04-20 11:12:10 (14000): Command: VBoxManage -q modifyvm "boinc_eeaccc3abf1e02d6" --description "08281192_27_2" Exit Code: 0 Output: 2021-04-20 11:12:10 (14000): Command: VBoxManage -q modifyvm "boinc_eeaccc3abf1e02d6" --memory 3072 Exit Code: 0 Output: 2021-04-20 11:12:11 (14000): Command: VBoxManage -q modifyvm "boinc_eeaccc3abf1e02d6" --cpus 1 Exit Code: 0 Output: 2021-04-20 11:12:11 (14000): Command: VBoxManage -q modifyvm "boinc_eeaccc3abf1e02d6" --acpi on --ioapic on Exit Code: 0 Output: 2021-04-20 11:12:11 (14000): Command: VBoxManage -q modifyvm "boinc_eeaccc3abf1e02d6" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2021-04-20 11:12:12 (14000): Command: VBoxManage -q modifyvm "boinc_eeaccc3abf1e02d6" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2021-04-20 11:12:12 (14000): Command: VBoxManage -q modifyvm "boinc_eeaccc3abf1e02d6" --cableconnected1 on Exit Code: 0 Output: 2021-04-20 11:12:12 (14000): Command: VBoxManage -q modifyvm "boinc_eeaccc3abf1e02d6" --usb off Exit Code: 0 Output: 2021-04-20 11:12:12 (14000): Command: VBoxManage -q modifyvm "boinc_eeaccc3abf1e02d6" --uart1 off --uart2 off Exit Code: 0 Output: 2021-04-20 11:12:13 (14000): Command: VBoxManage -q modifyvm "boinc_eeaccc3abf1e02d6" --lpt1 off --lpt2 off Exit Code: 0 Output: 2021-04-20 11:12:13 (14000): Command: VBoxManage -q modifyvm "boinc_eeaccc3abf1e02d6" --audio none Exit Code: 0 Output: 2021-04-20 11:12:13 (14000): Command: VBoxManage -q modifyvm "boinc_eeaccc3abf1e02d6" --clipboard disabled Exit Code: 0 Output: 2021-04-20 11:12:13 (14000): Command: VBoxManage -q modifyvm "boinc_eeaccc3abf1e02d6" --draganddrop disabled Exit Code: 0 Output: 2021-04-20 11:12:14 (14000): Command: VBoxManage -q storagectl "boinc_eeaccc3abf1e02d6" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2021-04-20 11:12:14 (14000): Command: VBoxManage -q storageattach "boinc_eeaccc3abf1e02d6" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\ProgramData\BOINC\slots\2/vm_isocontext.iso" Exit Code: 0 Output: 2021-04-20 11:12:14 (14000): Command: VBoxManage -q storageattach "boinc_eeaccc3abf1e02d6" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2021-04-20 11:12:15 (14000): Command: VBoxManage -q bandwidthctl "boinc_eeaccc3abf1e02d6" add "boinc_eeaccc3abf1e02d6_net" --type network --limit 1024G Exit Code: 0 Output: 2021-04-20 11:12:15 (14000): Command: VBoxManage -q sharedfolder add "boinc_eeaccc3abf1e02d6" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\2/shared" Exit Code: 0 Output: 2021-04-20 11:12:20 (14000): Command: VBoxManage -q startvm "boinc_eeaccc3abf1e02d6" --type headless Exit Code: -2147467259 Output: Waiting for VM "boinc_eeaccc3abf1e02d6" to power on... VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2021-04-20 11:12:20 (14000): Command: VBoxManage -q snapshot "boinc_eeaccc3abf1e02d6" list Exit Code: -108 Output: This machine does not have any snapshots 2021-04-20 11:12:20 (14000): Command: VBoxManage -q bandwidthctl "boinc_eeaccc3abf1e02d6" remove "boinc_eeaccc3abf1e02d6_net" Exit Code: 0 Output: 2021-04-20 11:12:20 (14000): Command: VBoxManage -q unregistervm "boinc_eeaccc3abf1e02d6" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 2021-04-20 11:12:21 (14000): Command: VBoxManage -q closemedium dvd "C:\ProgramData\BOINC\slots\2/vm_isocontext.iso" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 11:12:26 (14000): called boinc_finish(-2147467259) </stderr_txt> ]]>
©2025 COPYRIGHT 2017-2018 NCN