Name | 08283097_43_1 |
Workunit | 7983594 |
Created | 20 Apr 2021, 12:14:03 UTC |
Sent | 20 Apr 2021, 12:14:37 UTC |
Report deadline | 25 Apr 2021, 12:14:37 UTC |
Received | 21 Apr 2021, 4:00:04 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | -2135228415 (0x80BB0001) Unknown error code |
Computer ID | 11435 |
Run time | 3 min 13 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 3.53 GFLOPS |
Application version | boinc2docker v1.14 (vbox64_mt) windows_x86_64 |
Peak working set size | 10.89 MB |
Peak swap size | 6.21 MB |
Peak disk usage | 273.82 MB |
<core_client_version>7.16.11</core_client_version> <![CDATA[ <message> (unknown error) - exit code 2159738881 (0x80bb0001)</message> <stderr_txt> 2021-04-20 21:54:19 (46392): Detected: vboxwrapper 26202 2021-04-20 21:54:35 (46392): Detected: BOINC client v7.16.11 2021-04-20 21:54:54 (46392): Detected: VirtualBox VboxManage Interface (Version: 6.1.12) 2021-04-20 21:55:25 (46392): Error in registration for VM: -108 Arguments: VBoxManage -q showvminfo "boinc_b7daef5d44aede54" --machinereadable Output: 2021-04-20 21:55:27 (46392): Starting VM using VBoxManage interface. (boinc_b7daef5d44aede54, slot#2) 2021-04-20 21:56:14 (46392): Error in start VM for VM: -2135228415 Command: VBoxManage -q startvm "boinc_b7daef5d44aede54" --type headless Output: VBoxManage.exe: error: Could not find a registered machine named 'boinc_b7daef5d44aede54' VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown VBoxManage.exe: error: Context: "FindMachine(Bstr(pszVM).raw(), machine.asOutParam())" at line 722 of file VBoxManageMisc.cpp 2021-04-20 21:56:14 (46392): VM failed to start. 2021-04-20 21:56:14 (46392): Could not start 2021-04-20 21:56:14 (46392): ERROR: VM failed to start 2021-04-20 21:56:14 (46392): Powering off VM. 2021-04-20 21:56:14 (46392): Deregistering VM. (boinc_b7daef5d44aede54, slot#2) 2021-04-20 21:56:16 (46392): Removing network bandwidth throttle group from VM. 2021-04-20 21:56:18 (46392): Removing VM from VirtualBox. 2021-04-20 21:56:29 (46392): Removing virtual ISO 9660 disk from VirtualBox. Hypervisor System Log: 145:19:32.418197 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_aab598653dc431fe\boinc_aab598653dc431fe.vbox" with version "1.16-windows" 145:19:33.181465 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_aab598653dc431fe\boinc_aab598653dc431fe.vbox" with version "1.16-windows" 145:19:33.462964 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 145:19:33.463511 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 145:19:33.464635 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_aab598653dc431fe\boinc_aab598653dc431fe.vbox" with version "1.16-windows" 145:19:34.144866 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 145:19:34.145442 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 145:19:34.146772 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_aab598653dc431fe\boinc_aab598653dc431fe.vbox" with version "1.16-windows" 145:19:34.405037 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_aab598653dc431fe\boinc_aab598653dc431fe.vbox" with version "1.16-windows" 145:19:34.705941 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_aab598653dc431fe\boinc_aab598653dc431fe.vbox" with version "1.16-windows" 145:19:35.288086 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 145:19:35.288251 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 145:19:35.297431 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 145:19:35.479133 Launched VM: 109333296 pid: 30492 (0x771c) frontend: headless name: boinc_aab598653dc431fe 145:19:58.317180 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_aab598653dc431fe\boinc_aab598653dc431fe.vbox" with version "1.16-windows" 145:25:06.441941 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_aab598653dc431fe\boinc_aab598653dc431fe.vbox" with version "1.16-windows" 145:25:09.223104 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 145:25:36.522828 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_aab598653dc431fe\boinc_aab598653dc431fe.vbox" with version "1.16-windows" 145:26:33.301829 Saving settings file "C:\Users\User\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 145:29:48.188819 ERROR [COM]: aRC=VBOX_E_OBJECT_IN_USE (0x80bb000c) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Cannot delete storage: medium 'C:\ProgramData\BOINC\slots\2\vm_isocontext.iso' is still attached to the following 12 virtual machine(s): 8cd32490-3242-4089-9248-704049bc404e, 4a16cc61-2a2d-4f95-9fc2-2bbc11ac97a1, 13179f67-f831-4aca-a884-e9fb993d0693, 0e85eb43-ffc6-4d15-af6e-ff07bd3a8c77, ab60b683-7dab-44b9-be5b-306ad629105b, 99eb0d9c-2341-4322-b665-b577639b566e, 5a07ac42-2171-42cf-91be-a1b01267e8b6, 601f469e-65cf-4112-9ed1-fd71ff6d1484, 0700e632-01c5-43cd-a63c-f6f98f640b9e, 521e70ee-fe40-4e5e-98d1-3b29ac0c287a, 7792d3a2-c545-479a-84ad-8e087bc46202, f9e33de9-b332-4c41-b204-8c5251363734}, preserve=false aResultDetail=0 145:29:48.189004 ERROR [COM]: aRC=VBOX_E_INVALID_OBJECT_STATE (0x80bb0007) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Storage for the medium 'C:\ProgramData\BOINC\slots\2\vm_isocontext.iso' is already created}, preserve=false aResultDetail=0 145:29:48.195835 ERROR [COM]: aRC=VBOX_E_OBJECT_IN_USE (0x80bb000c) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Medium 'C:\ProgramData\BOINC\slots\2\vm_isocontext.iso' cannot be closed because it is still attached to 12 virtual machines}, preserve=false aResultDetail=0 145:33:18.041682 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={Could not find a registered machine named 'boinc_b7daef5d44aede54'}, preserve=false aResultDetail=0 145:33:28.860239 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={Could not find a registered machine named 'boinc_b7daef5d44aede54'}, preserve=false aResultDetail=0 145:33:35.699558 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={Could not find a registered machine named 'boinc_b7daef5d44aede54'}, preserve=false aResultDetail=0 145:34:16.763320 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={Could not find a registered machine named 'boinc_b7daef5d44aede54'}, preserve=false aResultDetail=0 145:34:19.274824 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={Could not find a registered machine named 'boinc_b7daef5d44aede54'}, preserve=false aResultDetail=0 145:34:22.043442 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={Could not find a registered machine named 'boinc_b7daef5d44aede54'}, preserve=false aResultDetail=0 145:34:32.619551 ERROR [COM]: aRC=VBOX_E_OBJECT_IN_USE (0x80bb000c) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Cannot delete storage: medium 'C:\ProgramData\BOINC\slots\2\vm_isocontext.iso' is still attached to the following 12 virtual machine(s): 8cd32490-3242-4089-9248-704049bc404e, 4a16cc61-2a2d-4f95-9fc2-2bbc11ac97a1, 13179f67-f831-4aca-a884-e9fb993d0693, 0e85eb43-ffc6-4d15-af6e-ff07bd3a8c77, ab60b683-7dab-44b9-be5b-306ad629105b, 99eb0d9c-2341-4322-b665-b577639b566e, 5a07ac42-2171-42cf-91be-a1b01267e8b6, 601f469e-65cf-4112-9ed1-fd71ff6d1484, 0700e632-01c5-43cd-a63c-f6f98f640b9e, 521e70ee-fe40-4e5e-98d1-3b29ac0c287a, 7792d3a2-c545-479a-84ad-8e087bc46202, f9e33de9-b332-4c41-b204-8c5251363734}, preserve=false aResultDetail=0 145:34:32.619776 ERROR [COM]: aRC=VBOX_E_INVALID_OBJECT_STATE (0x80bb0007) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Storage for the medium 'C:\ProgramData\BOINC\slots\2\vm_isocontext.iso' is already created}, preserve=false aResultDetail=0 145:34:32.623135 ERROR [COM]: aRC=VBOX_E_OBJECT_IN_USE (0x80bb000c) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Medium 'C:\ProgramData\BOINC\slots\2\vm_isocontext.iso' cannot be closed because it is still attached to 12 virtual machines}, preserve=false aResultDetail=0 VM Execution Log: VM Startup Log: VM Trace Log: 2021-04-20 21:54:42 (46392): Command: VBoxManage -q --version Exit Code: 0 Output: 6.1.12r139181 2021-04-20 21:54:54 (46392): Command: VBoxManage -q list systemproperties Exit Code: 0 Output: API version: 6_1 Minimum guest RAM size: 4 Megabytes Maximum guest RAM size: 2097152 Megabytes Minimum video RAM size: 0 Megabytes Maximum video RAM size: 256 Megabytes Maximum guest monitor count: 64 Minimum guest CPU count: 1 Maximum guest CPU count: 32 Virtual disk limit (info): 2199022206976 Bytes Maximum Serial Port count: 4 Maximum Parallel Port count: 2 Maximum Boot Position: 4 Maximum PIIX3 Network Adapter count: 8 Maximum ICH9 Network Adapter count: 36 Maximum PIIX3 IDE Controllers: 1 Maximum ICH9 IDE Controllers: 1 Maximum IDE Port count: 2 Maximum Devices per IDE Port: 2 Maximum PIIX3 SATA Controllers: 1 Maximum ICH9 SATA Controllers: 8 Maximum SATA Port count: 30 Maximum Devices per SATA Port: 1 Maximum PIIX3 SCSI Controllers: 1 Maximum ICH9 SCSI Controllers: 8 Maximum SCSI Port count: 16 Maximum Devices per SCSI Port: 1 Maximum SAS PIIX3 Controllers: 1 Maximum SAS ICH9 Controllers: 8 Maximum SAS Port count: 255 Maximum Devices per SAS Port: 1 Maximum NVMe PIIX3 Controllers: 1 Maximum NVMe ICH9 Controllers: 8 Maximum NVMe Port count: 255 Maximum Devices per NVMe Port: 1 Maximum virtio-scsi PIIX3 Controllers: 1 Maximum virtio-scsi ICH9 Controllers: 8 Maximum virtio-scsi Port count: 256 Maximum Devices per virtio-scsi Port: 1 Maximum PIIX3 Floppy Controllers:1 Maximum ICH9 Floppy Controllers: 1 Maximum Floppy Port count: 1 Maximum Devices per Floppy Port: 2 Default machine folder: C:\Users\User\VirtualBox VMs Raw-mode Supported: no Exclusive HW virtualization use: off Default hard disk format: VDI VRDE auth library: VBoxAuth Webservice auth. library: VBoxAuth Remote desktop ExtPack: Log history count: 3 Default frontend: Default audio driver: DirectSound Autostart database path: Default Guest Additions ISO: C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso Logging Level: all Proxy Mode: System Proxy URL: 2021-04-20 21:55:08 (46392): Command: VBoxManage -q list hostinfo Exit Code: 0 Output: Host Information: Host time: 2021-04-21T03:54:59.601000000Z Processor online count: 4 Processor count: 4 Processor online core count: 2 Processor core count: 2 Processor supports HW virtualization: yes Processor supports PAE: yes Processor supports long mode: yes Processor supports nested paging: yes Processor supports unrestricted guest: yes Processor supports nested HW virtualization: yes Processor#0 speed: unknown Processor#0 description: Intel(R) Core(TM) i7-4610M CPU @ 3.00GHz Processor#1 speed: unknown Processor#1 description: Intel(R) Core(TM) i7-4610M CPU @ 3.00GHz Processor#2 speed: unknown Processor#2 description: Intel(R) Core(TM) i7-4610M CPU @ 3.00GHz Processor#3 speed: unknown Processor#3 description: Intel(R) Core(TM) i7-4610M CPU @ 3.00GHz Memory size: 16289 MByte Memory available: 3189 MByte Operating system: Windows 10 Operating system version: 10.0.19042 2021-04-20 21:55:25 (46392): Command: VBoxManage -q showvminfo "boinc_b7daef5d44aede54" --machinereadable Exit Code: -108 Output: 2021-04-20 21:56:12 (46392): Command: VBoxManage -q startvm "boinc_b7daef5d44aede54" --type headless Exit Code: -2135228415 Output: VBoxManage.exe: error: Could not find a registered machine named 'boinc_b7daef5d44aede54' VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown VBoxManage.exe: error: Context: "FindMachine(Bstr(pszVM).raw(), machine.asOutParam())" at line 722 of file VBoxManageMisc.cpp 2021-04-20 21:56:16 (46392): Command: VBoxManage -q snapshot "boinc_b7daef5d44aede54" list Exit Code: -2135228415 Output: VBoxManage.exe: error: Could not find a registered machine named 'boinc_b7daef5d44aede54' VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown VBoxManage.exe: error: Context: "FindMachine(bstrMachine.raw(), pMachine.asOutParam())" at line 333 of file VBoxManageSnapshot.cpp 2021-04-20 21:56:18 (46392): Command: VBoxManage -q bandwidthctl "boinc_b7daef5d44aede54" remove "boinc_b7daef5d44aede54_net" Exit Code: -2135228415 Output: VBoxManage.exe: error: Could not find a registered machine named 'boinc_b7daef5d44aede54' VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown VBoxManage.exe: error: Context: "FindMachine(Bstr(a->argv[0]).raw(), machine.asOutParam())" at line 320 of file VBoxManageBandwidthControl.cpp 2021-04-20 21:56:29 (46392): Command: VBoxManage -q unregistervm "boinc_b7daef5d44aede54" --delete Exit Code: -2135228415 Output: VBoxManage.exe: error: Could not find a registered machine named 'boinc_b7daef5d44aede54' VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown VBoxManage.exe: error: Context: "FindMachine(Bstr(VMName).raw(), machine.asOutParam())" at line 150 of file VBoxManageMisc.cpp 2021-04-20 21:56:55 (46392): Command: VBoxManage -q closemedium dvd "C:\ProgramData\BOINC\slots\2/vm_isocontext.iso" --delete Exit Code: -2135228404 Output: VBoxManage.exe: error: Cannot delete storage: medium 'C:\ProgramData\BOINC\slots\2\vm_isocontext.iso' is still attached to the following 12 virtual machine(s): 8cd32490-3242-4089-9248-704049bc404e, 4a16cc61-2a2d-4f95-9fc2-2bbc11ac97a1, 13179f67-f831-4aca-a884-e9fb993d0693, 0e85eb43-ffc6-4d15-af6e-ff07bd3a8c77, ab60b683-7dab-44b9-be5b-306ad629105b, 99eb0d9c-2341-4322-b665-b577639b566e, 5a07ac42-2171-42cf-91be-a1b01267e8b6, 601f469e-65cf-4112-9ed1-fd71ff6d1484, 0700e632-01c5-43cd-a63c-f6f98f640b9e, 521e70ee-fe40-4e5e-98d1-3b29ac0c287a, 7792d3a2-c545-479a-84ad-8e087bc46202, f9e33de9-b332-4c41-b204-8c5251363734 VBoxManage.exe: error: Details: code VBOX_E_OBJECT_IN_USE (0x80bb000c), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "DeleteStorage(pProgress.asOutParam())" at line 1727 of file VBoxManageDisk.cpp VBoxManage.exe: error: Failed to delete medium. Error code Unknown Status -2135228404 (0x80bb000c) VBoxManage.exe: error: Medium 'C:\ProgramData\BOINC\slots\2\vm_isocontext.iso' cannot be closed because it is still attached to 12 virtual machines VBoxManage.exe: error: Details: code VBOX_E_OBJECT_IN_USE (0x80bb000c), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "Close()" at line 1736 of file VBoxManageDisk.cpp 21:57:14 (46392): called boinc_finish(-2135228415) </stderr_txt> ]]>
©2024 COPYRIGHT 2017-2018 NCN