Name | 08282909_06_3 |
Workunit | 7980384 |
Created | 22 Apr 2021, 3:22:27 UTC |
Sent | 22 Apr 2021, 3:42:06 UTC |
Report deadline | 27 Apr 2021, 3:42:06 UTC |
Received | 22 Apr 2021, 7:17:49 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | -2147467259 (0x80004005) Unknown error code |
Computer ID | 11020 |
Run time | 18 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 5.26 GFLOPS |
Application version | boinc2docker v1.14 (vbox64_mt) windows_x86_64 |
Peak working set size | 10.90 MB |
Peak swap size | 6.23 MB |
Peak disk usage | 273.82 MB |
<core_client_version>7.16.11</core_client_version> <![CDATA[ <message> Unspecified error (0x80004005) - exit code 2147500037 (0x80004005)</message> <stderr_txt> 2021-04-22 05:49:57 (13800): Detected: vboxwrapper 26202 2021-04-22 05:49:57 (13800): Detected: BOINC client v7.16.11 2021-04-22 05:49:58 (13800): Detected: VirtualBox VboxManage Interface (Version: 6.1.18) 2021-04-22 05:49:59 (13800): Create VM. (boinc_d79bb0129f2ebc37, slot#10) 2021-04-22 05:49:59 (13800): Updating drive controller type and model for desired configuration. 2021-04-22 05:49:59 (13800): Setting Memory Size for VM. (3072MB) 2021-04-22 05:49:59 (13800): Setting CPU Count for VM. (1) 2021-04-22 05:50:00 (13800): Setting Chipset Options for VM. 2021-04-22 05:50:00 (13800): Setting Boot Options for VM. 2021-04-22 05:50:00 (13800): Setting Network Configuration for NAT. 2021-04-22 05:50:00 (13800): Enabling VM Network Access. 2021-04-22 05:50:01 (13800): Disabling USB Support for VM. 2021-04-22 05:50:01 (13800): Disabling COM Port Support for VM. 2021-04-22 05:50:01 (13800): Disabling LPT Port Support for VM. 2021-04-22 05:50:01 (13800): Disabling Audio Support for VM. 2021-04-22 05:50:02 (13800): Disabling Clipboard Support for VM. 2021-04-22 05:50:02 (13800): Disabling Drag and Drop Support for VM. 2021-04-22 05:50:02 (13800): Adding storage controller(s) to VM. 2021-04-22 05:50:02 (13800): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso) 2021-04-22 05:50:03 (13800): Adding VirtualBox Guest Additions to VM. 2021-04-22 05:50:03 (13800): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2021-04-22 05:50:03 (13800): Enabling shared directory for VM. 2021-04-22 05:50:04 (13800): Starting VM using VBoxManage interface. (boinc_d79bb0129f2ebc37, slot#10) 2021-04-22 05:50:06 (13800): Error in start VM for VM: -2147467259 Command: VBoxManage -q startvm "boinc_d79bb0129f2ebc37" --type headless Output: Waiting for VM "boinc_d79bb0129f2ebc37" to power on... VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: AMD-V is disabled in the BIOS (or by the host OS) (VERR_SVM_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2021-04-22 05:50:06 (13800): VM failed to start. 2021-04-22 05:50:06 (13800): Could not start 2021-04-22 05:50:06 (13800): ERROR: VM failed to start 2021-04-22 05:50:06 (13800): Powering off VM. 2021-04-22 05:50:06 (13800): Deregistering VM. (boinc_d79bb0129f2ebc37, slot#10) 2021-04-22 05:50:06 (13800): Removing network bandwidth throttle group from VM. 2021-04-22 05:50:06 (13800): Removing VM from VirtualBox. 2021-04-22 05:50:07 (13800): Removing virtual ISO 9660 disk from VirtualBox. Hypervisor System Log: 00:00:06.120048 Saving settings file "C:\Users\Matth\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:06.122921 Saving settings file "C:\ProgramData\BOINC\slots\10\boinc_d79bb0129f2ebc37\boinc_d79bb0129f2ebc37.vbox" with version "1.16-windows" 00:00:06.134543 Saving settings file "C:\ProgramData\BOINC\slots\27\boinc_d9e8445bda8e837f\boinc_d9e8445bda8e837f.vbox" with version "1.16-windows" 00:00:06.316012 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:06.316160 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:06.323228 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:06.377987 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:06.378429 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:06.379023 Saving settings file "C:\ProgramData\BOINC\slots\10\boinc_d79bb0129f2ebc37\boinc_d79bb0129f2ebc37.vbox" with version "1.16-windows" 00:00:06.391520 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:06.392577 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:06.392746 Saving settings file "C:\Users\Matth\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:06.395234 Saving settings file "C:\Users\Matth\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:06.398385 Saving settings file "C:\ProgramData\BOINC\slots\27\boinc_d9e8445bda8e837f\boinc_d9e8445bda8e837f.vbox" with version "1.16-windows" 00:00:06.573530 Launched VM: 69421232 pid: 8148 (0x1fd4) frontend: headless name: boinc_d4f48c63f6ef9a70 00:00:06.643394 Saving settings file "C:\ProgramData\BOINC\slots\10\boinc_d79bb0129f2ebc37\boinc_d79bb0129f2ebc37.vbox" with version "1.16-windows" 00:00:06.654978 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:06.655307 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:06.655748 Saving settings file "C:\ProgramData\BOINC\slots\27\boinc_d9e8445bda8e837f\boinc_d9e8445bda8e837f.vbox" with version "1.16-windows" 00:00:06.901038 Saving settings file "C:\ProgramData\BOINC\slots\10\boinc_d79bb0129f2ebc37\boinc_d79bb0129f2ebc37.vbox" with version "1.16-windows" 00:00:06.916164 Saving settings file "C:\ProgramData\BOINC\slots\27\boinc_d9e8445bda8e837f\boinc_d9e8445bda8e837f.vbox" with version "1.16-windows" 00:00:07.169255 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.169423 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.177092 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:07.186118 Saving settings file "C:\ProgramData\BOINC\slots\27\boinc_d9e8445bda8e837f\boinc_d9e8445bda8e837f.vbox" with version "1.16-windows" 00:00:07.433912 Launched VM: 69467968 pid: 17820 (0x459c) frontend: headless name: boinc_d79bb0129f2ebc37 00:00:07.451402 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.451546 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.458914 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:07.708455 Launched VM: 69660080 pid: 15328 (0x3be0) frontend: headless name: boinc_d9e8445bda8e837f 00:00:08.779925 Saving settings file "C:\ProgramData\BOINC\slots\26\boinc_d4f48c63f6ef9a70\boinc_d4f48c63f6ef9a70.vbox" with version "1.16-windows" 00:00:08.840151 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:09.138225 Saving settings file "C:\Users\Matth\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:09.610378 Saving settings file "C:\ProgramData\BOINC\slots\10\boinc_d79bb0129f2ebc37\boinc_d79bb0129f2ebc37.vbox" with version "1.16-windows" 00:00:09.669672 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:09.918691 Saving settings file "C:\ProgramData\BOINC\slots\27\boinc_d9e8445bda8e837f\boinc_d9e8445bda8e837f.vbox" with version "1.16-windows" 00:00:09.974828 Saving settings file "C:\Users\Matth\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:09.976880 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:10.284503 Saving settings file "C:\Users\Matth\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:15.565811 main VirtualBox: object deletion starts 00:00:15.566385 main HostDnsMonitor: shutting down ... 00:00:15.566417 main HostDnsMonitor: shut down 00:00:15.567574 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:15.567862 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: time: 2021-04-22T03:49:58.300000000Z Processor online count: 24 Processor count: 24 Processor online core count: 12 Processor core count: 12 Processor supports HW virtualization: no Processor supports PAE: yes Processor supports long mode: yes Processor supports nested paging: no Processor supports unrestricted guest: no Processor supports nested HW virtualization: no Processor#0 speed: unknown Processor#0 description: AMD Ryzen 9 3900X 12-Core Processor Processor#1 speed: unknown Processor#1 description: AMD Ryzen 9 3900X 12-Core Processor Processor#2 speed: unknown Processor#2 description: AMD Ryzen 9 3900X 12-Core Processor Processor#3 speed: unknown Processor#3 description: AMD Ryzen 9 3900X 12-Core Processor Processor#4 speed: unknown Processor#4 description: AMD Ryzen 9 3900X 12-Core Processor Processor#5 speed: unknown Processor#5 description: AMD Ryzen 9 3900X 12-Core Processor Processor#6 speed: unknown Processor#6 description: AMD Ryzen 9 3900X 12-Core Processor Processor#7 speed: unknown Processor#7 description: AMD Ryzen 9 3900X 12-Core Processor Processor#8 speed: unknown Processor#8 description: AMD Ryzen 9 3900X 12-Core Processor Processor#9 speed: unknown Processor#9 description: AMD Ryzen 9 3900X 12-Core Processor Processor#10 speed: unknown Processor#10 description: AMD Ryzen 9 3900X 12-Core Processor Processor#11 speed: unknown Processor#11 description: AMD Ryzen 9 3900X 12-Core Processor Processor#12 speed: unknown Processor#12 description: AMD Ryzen 9 3900X 12-Core Processor Processor#13 speed: unknown Processor#13 description: AMD Ryzen 9 3900X 12-Core Processor Processor#14 speed: unknown Processor#14 description: AMD Ryzen 9 3900X 12-Core Processor Processor#15 speed: unknown Processor#15 description: AMD Ryzen 9 3900X 12-Core Processor Processor#16 speed: unknown Processor#16 description: AMD Ryzen 9 3900X 12-Core Processor Processor#17 speed: unknown Processor#17 description: AMD Ryzen 9 3900X 12-Core Processor Processor#18 speed: unknown Processor#18 description: AMD Ryzen 9 3900X 12-Core Processor Processor#19 speed: unknown Processor#19 description: AMD Ryzen 9 3900X 12-Core Processor Processor#20 speed: unknown Processor#20 description: AMD Ryzen 9 3900X 12-Core Processor Processor#21 speed: unknown Processor#21 description: AMD Ryzen 9 3900X 12-Core Processor Processor#22 speed: unknown Processor#22 description: AMD Ryzen 9 3900X 12-Core Processor Processor#23 speed: unknown Processor#23 description: AMD Ryzen 9 3900X 12-Core Processor Memory size: 32681 MByte Memory available: 21989 MByte Operating system: Windows 10 Operating system version: 10.0.19042 2021-04-22 05:49:58 (13800): Command: VBoxManage -q showvminfo "boinc_d79bb0129f2ebc37" --machinereadable Exit Code: -2135228415 Output: VBoxManage.exe: error: Could not find a registered machine named 'boinc_d79bb0129f2ebc37' VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2715 of file VBoxManageInfo.cpp 2021-04-22 05:49:59 (13800): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\10/vm_image.vdi" Exit Code: -2135228412 Output: VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\10\vm_image.vdi' (VERR_FILE_NOT_FOUND) VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp 2021-04-22 05:49:59 (13800): Command: VBoxManage -q createvm --name "boinc_d79bb0129f2ebc37" --basefolder "C:\ProgramData\BOINC\slots\10" --ostype "Linux26_64" --register Exit Code: 0 Output: 2021-04-22 05:49:59 (13800): Command: VBoxManage -q modifyvm "boinc_d79bb0129f2ebc37" --description "08282909_06_3" Exit Code: 0 Output: 2021-04-22 05:49:59 (13800): Command: VBoxManage -q modifyvm "boinc_d79bb0129f2ebc37" --memory 3072 Exit Code: 0 Output: 2021-04-22 05:50:00 (13800): Command: VBoxManage -q modifyvm "boinc_d79bb0129f2ebc37" --cpus 1 Exit Code: 0 Output: 2021-04-22 05:50:00 (13800): Command: VBoxManage -q modifyvm "boinc_d79bb0129f2ebc37" --acpi on --ioapic on Exit Code: 0 Output: 2021-04-22 05:50:00 (13800): Command: VBoxManage -q modifyvm "boinc_d79bb0129f2ebc37" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2021-04-22 05:50:00 (13800): Command: VBoxManage -q modifyvm "boinc_d79bb0129f2ebc37" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2021-04-22 05:50:01 (13800): Command: VBoxManage -q modifyvm "boinc_d79bb0129f2ebc37" --cableconnected1 on Exit Code: 0 Output: 2021-04-22 05:50:01 (13800): Command: VBoxManage -q modifyvm "boinc_d79bb0129f2ebc37" --usb off Exit Code: 0 Output: 2021-04-22 05:50:01 (13800): Command: VBoxManage -q modifyvm "boinc_d79bb0129f2ebc37" --uart1 off --uart2 off Exit Code: 0 Output: 2021-04-22 05:50:01 (13800): Command: VBoxManage -q modifyvm "boinc_d79bb0129f2ebc37" --lpt1 off --lpt2 off Exit Code: 0 Output: 2021-04-22 05:50:02 (13800): Command: VBoxManage -q modifyvm "boinc_d79bb0129f2ebc37" --audio none Exit Code: 0 Output: 2021-04-22 05:50:02 (13800): Command: VBoxManage -q modifyvm "boinc_d79bb0129f2ebc37" --clipboard disabled Exit Code: 0 Output: 2021-04-22 05:50:02 (13800): Command: VBoxManage -q modifyvm "boinc_d79bb0129f2ebc37" --draganddrop disabled Exit Code: 0 Output: 2021-04-22 05:50:02 (13800): Command: VBoxManage -q storagectl "boinc_d79bb0129f2ebc37" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2021-04-22 05:50:03 (13800): Command: VBoxManage -q storageattach "boinc_d79bb0129f2ebc37" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\ProgramData\BOINC\slots\10/vm_isocontext.iso" Exit Code: 0 Output: 2021-04-22 05:50:03 (13800): Command: VBoxManage -q storageattach "boinc_d79bb0129f2ebc37" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2021-04-22 05:50:03 (13800): Command: VBoxManage -q bandwidthctl "boinc_d79bb0129f2ebc37" add "boinc_d79bb0129f2ebc37_net" --type network --limit 1024G Exit Code: 0 Output: 2021-04-22 05:50:04 (13800): Command: VBoxManage -q sharedfolder add "boinc_d79bb0129f2ebc37" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\10/shared" Exit Code: 0 Output: 2021-04-22 05:50:06 (13800): Command: VBoxManage -q startvm "boinc_d79bb0129f2ebc37" --type headless Exit Code: -2147467259 Output: Waiting for VM "boinc_d79bb0129f2ebc37" to power on... VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: AMD-V is disabled in the BIOS (or by the host OS) (VERR_SVM_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2021-04-22 05:50:06 (13800): Command: VBoxManage -q snapshot "boinc_d79bb0129f2ebc37" list Exit Code: -108 Output: This machine does not have any snapshots 2021-04-22 05:50:06 (13800): Command: VBoxManage -q bandwidthctl "boinc_d79bb0129f2ebc37" remove "boinc_d79bb0129f2ebc37_net" Exit Code: 0 Output: VBoxManage.exe: error: Bandwidth groups cannot be deleted while the VM is running 2021-04-22 05:50:07 (13800): Command: VBoxManage -q unregistervm "boinc_d79bb0129f2ebc37" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 2021-04-22 05:50:07 (13800): Command: VBoxManage -q closemedium dvd "C:\ProgramData\BOINC\slots\10/vm_isocontext.iso" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 05:50:13 (13800): called boinc_finish(-2147467259) </stderr_txt> ]]>
©2025 COPYRIGHT 2017-2018 NCN