Task 10381361

Name 08283014_36_2
Workunit 7982065
Created 22 Apr 2021, 17:21:15 UTC
Sent 22 Apr 2021, 17:25:05 UTC
Report deadline 27 Apr 2021, 17:25:05 UTC
Received 24 Apr 2021, 10:24:55 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status -2147467259 (0x80004005) Unknown error code
Computer ID 10598
Run time 16 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 3.99 GFLOPS
Application version boinc2docker v1.14 (vbox64_mt)
windows_x86_64
Peak working set size 12.54 MB
Peak swap size 7.20 MB
Peak disk usage 227.37 MB

Stderr output

<core_client_version>7.16.11</core_client_version>
<![CDATA[
<message>
Unspecified error
 (0x80004005) - exit code 2147500037 (0x80004005)</message>
<stderr_txt>
2021-04-22 18:25:24 (17080): Detected: vboxwrapper 26202
2021-04-22 18:25:24 (17080): Detected: BOINC client v7.16.11
2021-04-22 18:25:25 (17080): Detected: VirtualBox VboxManage Interface (Version: 6.1.12)
2021-04-22 18:25:26 (17080): Create VM. (boinc_6cd454c3a541b86b, slot#7)
2021-04-22 18:25:26 (17080): Updating drive controller type and model for desired configuration.
2021-04-22 18:25:26 (17080): Setting Memory Size for VM. (3072MB)
2021-04-22 18:25:26 (17080): Setting CPU Count for VM. (1)
2021-04-22 18:25:27 (17080): Setting Chipset Options for VM.
2021-04-22 18:25:27 (17080): Setting Boot Options for VM.
2021-04-22 18:25:27 (17080): Setting Network Configuration for NAT.
2021-04-22 18:25:27 (17080): Enabling VM Network Access.
2021-04-22 18:25:28 (17080): Disabling USB Support for VM.
2021-04-22 18:25:28 (17080): Disabling COM Port Support for VM.
2021-04-22 18:25:28 (17080): Disabling LPT Port Support for VM.
2021-04-22 18:25:29 (17080): Disabling Audio Support for VM.
2021-04-22 18:25:29 (17080): Disabling Clipboard Support for VM.
2021-04-22 18:25:29 (17080): Disabling Drag and Drop Support for VM.
2021-04-22 18:25:29 (17080): Adding storage controller(s) to VM.
2021-04-22 18:25:30 (17080): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso)
2021-04-22 18:25:30 (17080): Adding VirtualBox Guest Additions to VM.
2021-04-22 18:25:30 (17080): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2021-04-22 18:25:30 (17080): Enabling shared directory for VM.
2021-04-22 18:25:31 (17080): Starting VM using VBoxManage interface. (boinc_6cd454c3a541b86b, slot#7)
2021-04-22 18:25:35 (17080): Error in start VM for VM: -2147467259
Command:
VBoxManage -q startvm "boinc_6cd454c3a541b86b" --type headless
Output:
Waiting for VM "boinc_6cd454c3a541b86b" to power on...
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole

2021-04-22 18:25:35 (17080): VM failed to start.
2021-04-22 18:25:35 (17080): Could not start 
2021-04-22 18:25:35 (17080): ERROR: VM failed to start
2021-04-22 18:25:35 (17080): Powering off VM.
2021-04-22 18:25:35 (17080): Deregistering VM. (boinc_6cd454c3a541b86b, slot#7)
2021-04-22 18:25:35 (17080): Removing network bandwidth throttle group from VM.
2021-04-22 18:25:35 (17080): Removing VM from VirtualBox.
2021-04-22 18:25:35 (17080): Removing virtual ISO 9660 disk from VirtualBox.

    Hypervisor System Log:

00:00:06.756209          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.777391          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:06.819386          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.819669          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.832088          Launched VM: 96898880 pid: 2720 (0xaa0) frontend: headless name: boinc_be4cb1801c464824
00:00:06.842985          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:06.912098          Launched VM: 96979328 pid: 8200 (0x2008) frontend: headless name: boinc_aba4838fd30fc296
00:00:06.915447          Launched VM: 73705072 pid: 10768 (0x2a10) frontend: headless name: boinc_b41fe081029a8cf4
00:00:07.014229          Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_6cd454c3a541b86b\boinc_6cd454c3a541b86b.vbox" with version "1.16-windows"
00:00:07.016029          Launched VM: 72863200 pid: 12576 (0x3120) frontend: headless name: boinc_082ea0e3641649c2
00:00:07.070741          Launched VM: 97059520 pid: 8320 (0x2080) frontend: headless name: boinc_f6d307f899ec3cb7
00:00:07.261177          Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_6cd454c3a541b86b\boinc_6cd454c3a541b86b.vbox" with version "1.16-windows"
00:00:07.533296          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.533627          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.551801          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:07.792613          Launched VM: 90046016 pid: 2360 (0x938) frontend: headless name: boinc_6cd454c3a541b86b
00:00:10.649062          Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_be4cb1801c464824\boinc_be4cb1801c464824.vbox" with version "1.16-windows"
00:00:10.649152          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_34c86221ad9b8662\boinc_34c86221ad9b8662.vbox" with version "1.16-windows"
00:00:10.649206          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_b41fe081029a8cf4\boinc_b41fe081029a8cf4.vbox" with version "1.16-windows"
00:00:10.650344          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_aba4838fd30fc296\boinc_aba4838fd30fc296.vbox" with version "1.16-windows"
00:00:10.729046          Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_082ea0e3641649c2\boinc_082ea0e3641649c2.vbox" with version "1.16-windows"
00:00:10.734683          Saving settings file "C:\ProgramData\BOINC\slots\6\boinc_f6d307f899ec3cb7\boinc_f6d307f899ec3cb7.vbox" with version "1.16-windows"
00:00:10.825599          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:10.830693          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:10.846534          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:10.859458          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:10.913992          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:10.931366          ERROR [COM]: aRC=VBOX_E_VM_ERROR (0x80bb0003) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={Failed to get a console object from the direct session (VBOX_E_INVALID_OBJECT_STATE)}, preserve=false aResultDetail=0
00:00:10.972959          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_34c86221ad9b8662\boinc_34c86221ad9b8662.vbox" with version "1.16-windows"
00:00:10.976768          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_b41fe081029a8cf4\boinc_b41fe081029a8cf4.vbox" with version "1.16-windows"
00:00:10.977152          Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_be4cb1801c464824\boinc_be4cb1801c464824.vbox" with version "1.16-windows"
00:00:11.007428          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_aba4838fd30fc296\boinc_aba4838fd30fc296.vbox" with version "1.16-windows"
00:00:11.047214          Saving settings file "C:\ProgramData\BOINC\slots\6\boinc_f6d307f899ec3cb7\boinc_f6d307f899ec3cb7.vbox" with version "1.16-windows"
00:00:11.047624          Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_082ea0e3641649c2\boinc_082ea0e3641649c2.vbox" with version "1.16-windows"
00:00:11.208224          Saving settings file "C:\Users\nessu\.VirtualBox\VirtualBox.xml" with version "1.14-windows"
00:00:11.217143          Saving settings file "C:\Users\nessu\.VirtualBox\VirtualBox.xml" with version "1.14-windows"
00:00:11.226264          Saving settings file "C:\Users\nessu\.VirtualBox\VirtualBox.xml" with version "1.14-windows"
00:00:11.236521          Saving settings file "C:\Users\nessu\.VirtualBox\VirtualBox.xml" with version "1.14-windows"
00:00:11.302499          Saving settings file "C:\Users\nessu\.VirtualBox\VirtualBox.xml" with version "1.14-windows"
00:00:11.311186          Saving settings file "C:\Users\nessu\.VirtualBox\VirtualBox.xml" with version "1.14-windows"
00:00:11.367932          Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_6cd454c3a541b86b\boinc_6cd454c3a541b86b.vbox" with version "1.16-windows"
00:00:11.487822          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:11.820157          Saving settings file "C:\Users\nessu\.VirtualBox\VirtualBox.xml" with version "1.14-windows"
00:00:17.087055 main     VirtualBox: object deletion starts
00:00:17.101033 main     HostDnsMonitor: shutting down ...
00:00:17.101102 main     HostDnsMonitor: shut down
00:00:17.107280 Watcher  ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0
00:00:17.108636 main     VirtualBox: object deleted

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

 PIIX3 Controllers:  1
Maximum NVMe ICH9 Controllers:   8
Maximum NVMe Port count:         255
Maximum Devices per NVMe Port:   1
Maximum virtio-scsi PIIX3 Controllers:  1
Maximum virtio-scsi ICH9 Controllers:   8
Maximum virtio-scsi Port count:         256
Maximum Devices per virtio-scsi Port:   1
Maximum PIIX3 Floppy Controllers:1
Maximum ICH9 Floppy Controllers: 1
Maximum Floppy Port count:       1
Maximum Devices per Floppy Port: 2
Default machine folder:          C:\Users\nessu\VirtualBox VMs
Raw-mode Supported:              no
Exclusive HW virtualization use: off
Default hard disk format:        VDI
VRDE auth library:               VBoxAuth
Webservice auth. library:        VBoxAuth
Remote desktop ExtPack:          
Log history count:               3
Default frontend:                
Default audio driver:            DirectSound
Autostart database path:         
Default Guest Additions ISO:     C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso
Logging Level:                   all
Proxy Mode:                      System
Proxy URL:                       

2021-04-22 18:25:25 (17080): 
Command: VBoxManage -q list hostinfo 
Exit Code: 0
Output:
Host Information:

Host time: 2021-04-22T17:25:25.431000000Z
Processor online count: 8
Processor count: 8
Processor online core count: 4
Processor core count: 4
Processor supports HW virtualization: no
Processor supports PAE: yes
Processor supports long mode: yes
Processor supports nested paging: no
Processor supports unrestricted guest: no
Processor supports nested HW virtualization: no
Processor#0 speed: unknown
Processor#0 description: Intel(R) Core(TM) i7-6700 CPU @ 3.40GHz
Processor#1 speed: unknown
Processor#1 description: Intel(R) Core(TM) i7-6700 CPU @ 3.40GHz
Processor#2 speed: unknown
Processor#2 description: Intel(R) Core(TM) i7-6700 CPU @ 3.40GHz
Processor#3 speed: unknown
Processor#3 description: Intel(R) Core(TM) i7-6700 CPU @ 3.40GHz
Processor#4 speed: unknown
Processor#4 description: Intel(R) Core(TM) i7-6700 CPU @ 3.40GHz
Processor#5 speed: unknown
Processor#5 description: Intel(R) Core(TM) i7-6700 CPU @ 3.40GHz
Processor#6 speed: unknown
Processor#6 description: Intel(R) Core(TM) i7-6700 CPU @ 3.40GHz
Processor#7 speed: unknown
Processor#7 description: Intel(R) Core(TM) i7-6700 CPU @ 3.40GHz
Memory size: 65455 MByte
Memory available: 58774 MByte
Operating system: Windows 8
Operating system version: 6.2.9200

2021-04-22 18:25:25 (17080): 
Command: VBoxManage -q showvminfo "boinc_6cd454c3a541b86b" --machinereadable 
Exit Code: -2135228415
Output:
VBoxManage.exe: error: Could not find a registered machine named 'boinc_6cd454c3a541b86b'
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown
VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2715 of file VBoxManageInfo.cpp

2021-04-22 18:25:26 (17080): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\7/vm_image.vdi" 
Exit Code: -2135228412
Output:
VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\7\vm_image.vdi' (VERR_FILE_NOT_FOUND)
VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp

2021-04-22 18:25:26 (17080): 
Command: VBoxManage -q createvm --name "boinc_6cd454c3a541b86b" --basefolder "C:\ProgramData\BOINC\slots\7" --ostype "Linux26_64" --register
Exit Code: 0
Output:
Virtual machine 'boinc_6cd454c3a541b86b' is created and registered.
UUID: e499e4b2-000a-4725-862a-bb441afc5441
Settings file: 'C:\ProgramData\BOINC\slots\7\boinc_6cd454c3a541b86b\boinc_6cd454c3a541b86b.vbox'

2021-04-22 18:25:26 (17080): 
Command: VBoxManage -q modifyvm "boinc_6cd454c3a541b86b" --description "08283014_36_2" 
Exit Code: 0
Output:

2021-04-22 18:25:26 (17080): 
Command: VBoxManage -q modifyvm "boinc_6cd454c3a541b86b" --memory 3072 
Exit Code: 0
Output:

2021-04-22 18:25:27 (17080): 
Command: VBoxManage -q modifyvm "boinc_6cd454c3a541b86b" --cpus 1 
Exit Code: 0
Output:

2021-04-22 18:25:27 (17080): 
Command: VBoxManage -q modifyvm "boinc_6cd454c3a541b86b" --acpi on --ioapic on 
Exit Code: 0
Output:

2021-04-22 18:25:27 (17080): 
Command: VBoxManage -q modifyvm "boinc_6cd454c3a541b86b" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2021-04-22 18:25:27 (17080): 
Command: VBoxManage -q modifyvm "boinc_6cd454c3a541b86b" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2021-04-22 18:25:28 (17080): 
Command: VBoxManage -q modifyvm "boinc_6cd454c3a541b86b" --cableconnected1 on 
Exit Code: 0
Output:

2021-04-22 18:25:28 (17080): 
Command: VBoxManage -q modifyvm "boinc_6cd454c3a541b86b" --usb off 
Exit Code: 0
Output:

2021-04-22 18:25:28 (17080): 
Command: VBoxManage -q modifyvm "boinc_6cd454c3a541b86b" --uart1 off --uart2 off 
Exit Code: 0
Output:

2021-04-22 18:25:29 (17080): 
Command: VBoxManage -q modifyvm "boinc_6cd454c3a541b86b" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2021-04-22 18:25:29 (17080): 
Command: VBoxManage -q modifyvm "boinc_6cd454c3a541b86b" --audio none 
Exit Code: 0
Output:

2021-04-22 18:25:29 (17080): 
Command: VBoxManage -q modifyvm "boinc_6cd454c3a541b86b" --clipboard disabled 
Exit Code: 0
Output:

2021-04-22 18:25:29 (17080): 
Command: VBoxManage -q modifyvm "boinc_6cd454c3a541b86b" --draganddrop disabled 
Exit Code: 0
Output:

2021-04-22 18:25:30 (17080): 
Command: VBoxManage -q storagectl "boinc_6cd454c3a541b86b" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2021-04-22 18:25:30 (17080): 
Command: VBoxManage -q storageattach "boinc_6cd454c3a541b86b" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\ProgramData\BOINC\slots\7/vm_isocontext.iso" 
Exit Code: 0
Output:

2021-04-22 18:25:30 (17080): 
Command: VBoxManage -q storageattach "boinc_6cd454c3a541b86b" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2021-04-22 18:25:30 (17080): 
Command: VBoxManage -q bandwidthctl "boinc_6cd454c3a541b86b" add "boinc_6cd454c3a541b86b_net" --type network --limit 1024G 
Exit Code: 0
Output:

2021-04-22 18:25:31 (17080): 
Command: VBoxManage -q sharedfolder add "boinc_6cd454c3a541b86b" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\7/shared"
Exit Code: 0
Output:

2021-04-22 18:25:35 (17080): 
Command: VBoxManage -q startvm "boinc_6cd454c3a541b86b" --type headless
Exit Code: -2147467259
Output:
Waiting for VM "boinc_6cd454c3a541b86b" to power on...
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole

2021-04-22 18:25:35 (17080): 
Command: VBoxManage -q snapshot "boinc_6cd454c3a541b86b" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2021-04-22 18:25:35 (17080): 
Command: VBoxManage -q bandwidthctl "boinc_6cd454c3a541b86b" remove "boinc_6cd454c3a541b86b_net" 
Exit Code: 0
Output:
VBoxManage.exe: error: Bandwidth groups cannot be deleted while the VM is running

2021-04-22 18:25:35 (17080): 
Command: VBoxManage -q unregistervm "boinc_6cd454c3a541b86b" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

2021-04-22 18:25:35 (17080): 
Command: VBoxManage -q closemedium dvd "C:\ProgramData\BOINC\slots\7/vm_isocontext.iso" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

18:25:41 (17080): called boinc_finish(-2147467259)

</stderr_txt>
]]>


©2024 COPYRIGHT 2017-2018 NCN