Name | 08368315_33_0 |
Workunit | 8130892 |
Created | 12 Jun 2021, 2:29:11 UTC |
Sent | 12 Jun 2021, 5:15:32 UTC |
Report deadline | 17 Jun 2021, 5:15:32 UTC |
Received | 12 Jun 2021, 16:27:10 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | -2147467259 (0x80004005) Unknown error code |
Computer ID | 10330 |
Run time | 38 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 4.89 GFLOPS |
Application version | boinc2docker v1.14 (vbox64_mt) windows_x86_64 |
Peak working set size | 10.88 MB |
Peak swap size | 6.24 MB |
Peak disk usage | 498.91 MB |
<core_client_version>7.16.11</core_client_version> <![CDATA[ <message> Unspecified error (0x80004005) - exit code 2147500037 (0x80004005)</message> <stderr_txt> 2021-06-11 22:24:58 (7104): Detected: vboxwrapper 26202 2021-06-11 22:24:58 (7104): Detected: BOINC client v7.16.11 2021-06-11 22:24:58 (7104): Detected: VirtualBox VboxManage Interface (Version: 6.1.12) 2021-06-11 22:24:59 (7104): Create VM. (boinc_532cea6b561edab0, slot#2) 2021-06-11 22:24:59 (7104): Updating drive controller type and model for desired configuration. 2021-06-11 22:25:01 (7104): Setting Memory Size for VM. (3072MB) 2021-06-11 22:25:01 (7104): Setting CPU Count for VM. (1) 2021-06-11 22:25:02 (7104): Setting Chipset Options for VM. 2021-06-11 22:25:03 (7104): Setting Boot Options for VM. 2021-06-11 22:25:04 (7104): Setting Network Configuration for NAT. 2021-06-11 22:25:05 (7104): Enabling VM Network Access. 2021-06-11 22:25:09 (7104): Disabling USB Support for VM. 2021-06-11 22:25:16 (7104): Disabling COM Port Support for VM. 2021-06-11 22:25:18 (7104): Disabling LPT Port Support for VM. 2021-06-11 22:25:19 (7104): Disabling Audio Support for VM. 2021-06-11 22:25:21 (7104): Disabling Clipboard Support for VM. 2021-06-11 22:25:22 (7104): Disabling Drag and Drop Support for VM. 2021-06-11 22:25:23 (7104): Adding storage controller(s) to VM. 2021-06-11 22:25:23 (7104): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso) 2021-06-11 22:25:23 (7104): Adding VirtualBox Guest Additions to VM. 2021-06-11 22:25:23 (7104): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2021-06-11 22:25:24 (7104): Enabling shared directory for VM. 2021-06-11 22:25:24 (7104): Starting VM using VBoxManage interface. (boinc_532cea6b561edab0, slot#2) 2021-06-11 22:25:26 (7104): Error in start VM for VM: -2147467259 Command: VBoxManage -q startvm "boinc_532cea6b561edab0" --type headless Output: Waiting for VM "boinc_532cea6b561edab0" to power on... VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2021-06-11 22:25:26 (7104): VM failed to start. 2021-06-11 22:25:26 (7104): Could not start 2021-06-11 22:25:26 (7104): ERROR: VM failed to start 2021-06-11 22:25:26 (7104): Powering off VM. 2021-06-11 22:25:26 (7104): Deregistering VM. (boinc_532cea6b561edab0, slot#2) 2021-06-11 22:25:26 (7104): Removing network bandwidth throttle group from VM. 2021-06-11 22:25:26 (7104): Removing VM from VirtualBox. 2021-06-11 22:25:27 (7104): Removing virtual ISO 9660 disk from VirtualBox. Hypervisor System Log: 00:00:29.757176 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_65159058ee45e75c\boinc_65159058ee45e75c.vbox" with version "1.16-windows" 00:00:29.765657 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:29.765748 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:29.768854 Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_599cc66c90d2c507\boinc_599cc66c90d2c507.vbox" with version "1.16-windows" 00:00:29.770955 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:29.955175 ERROR [COM]: aRC=VBOX_E_INVALID_OBJECT_STATE (0x80bb0007) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={Cannot unregister the machine 'boinc_25b503749c732662' while it is locked}, preserve=false aResultDetail=0 00:00:29.955324 ERROR [COM]: aRC=VBOX_E_INVALID_OBJECT_STATE (0x80bb0007) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={Cannot unregister the machine 'boinc_3c9315a2f8d82903' while it is locked}, preserve=false aResultDetail=0 00:00:30.014473 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:30.015338 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:30.015458 Saving settings file "C:\Users\micha\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:30.183163 Launched VM: 72468768 pid: 9364 (0x2494) frontend: headless name: boinc_53da36b272716e72 00:00:30.188069 Saving settings file "C:\Users\micha\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:30.188508 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:30.188725 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:30.189989 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_532cea6b561edab0\boinc_532cea6b561edab0.vbox" with version "1.16-windows" 00:00:30.195664 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_65159058ee45e75c\boinc_65159058ee45e75c.vbox" with version "1.16-windows" 00:00:30.195707 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:30.245890 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:30.262468 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:30.262738 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:30.263156 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_65159058ee45e75c\boinc_65159058ee45e75c.vbox" with version "1.16-windows" 00:00:30.276485 Launched VM: 72584256 pid: 16512 (0x4080) frontend: headless name: boinc_599cc66c90d2c507 00:00:30.517413 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_65159058ee45e75c\boinc_65159058ee45e75c.vbox" with version "1.16-windows" 00:00:30.547682 Saving settings file "C:\Users\micha\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:30.788346 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_65159058ee45e75c\boinc_65159058ee45e75c.vbox" with version "1.16-windows" 00:00:31.052383 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:31.052470 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:31.057586 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:31.223789 Saving settings file "C:\Users\micha\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:31.316778 Launched VM: 71872336 pid: 15132 (0x3b1c) frontend: headless name: boinc_65159058ee45e75c 00:00:31.352500 Saving settings file "C:\Users\micha\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:32.065863 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_53da36b272716e72\boinc_53da36b272716e72.vbox" with version "1.16-windows" 00:00:32.118443 Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_599cc66c90d2c507\boinc_599cc66c90d2c507.vbox" with version "1.16-windows" 00:00:32.124955 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:32.164442 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:32.423500 Saving settings file "C:\Users\micha\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:32.457802 Saving settings file "C:\Users\micha\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:33.164449 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_65159058ee45e75c\boinc_65159058ee45e75c.vbox" with version "1.16-windows" 00:00:33.208029 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:33.504732 Saving settings file "C:\Users\micha\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:38.785514 main VirtualBox: object deletion starts 00:00:38.785964 main HostDnsMonitor: shutting down ... 00:00:38.785987 main HostDnsMonitor: shut down 00:00:38.787664 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:38.787771 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: Floppy Controllers: 1 Maximum Floppy Port count: 1 Maximum Devices per Floppy Port: 2 Default machine folder: C:\Users\micha\VirtualBox VMs Raw-mode Supported: no Exclusive HW virtualization use: off Default hard disk format: VDI VRDE auth library: VBoxAuth Webservice auth. library: VBoxAuth Remote desktop ExtPack: Log history count: 3 Default frontend: Default audio driver: DirectSound Autostart database path: Default Guest Additions ISO: C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso Logging Level: all Proxy Mode: System Proxy URL: 2021-06-11 22:24:59 (7104): Command: VBoxManage -q list hostinfo Exit Code: 0 Output: Host Information: Host time: 2021-06-12T05:24:58.803000000Z Processor online count: 12 Processor count: 12 Processor online core count: 6 Processor core count: 6 Processor supports HW virtualization: no Processor supports PAE: yes Processor supports long mode: yes Processor supports nested paging: no Processor supports unrestricted guest: no Processor supports nested HW virtualization: no Processor#0 speed: unknown Processor#0 description: Intel(R) Core(TM) i7-8700 CPU @ 3.20GHz Processor#1 speed: unknown Processor#1 description: Intel(R) Core(TM) i7-8700 CPU @ 3.20GHz Processor#2 speed: unknown Processor#2 description: Intel(R) Core(TM) i7-8700 CPU @ 3.20GHz Processor#3 speed: unknown Processor#3 description: Intel(R) Core(TM) i7-8700 CPU @ 3.20GHz Processor#4 speed: unknown Processor#4 description: Intel(R) Core(TM) i7-8700 CPU @ 3.20GHz Processor#5 speed: unknown Processor#5 description: Intel(R) Core(TM) i7-8700 CPU @ 3.20GHz Processor#6 speed: unknown Processor#6 description: Intel(R) Core(TM) i7-8700 CPU @ 3.20GHz Processor#7 speed: unknown Processor#7 description: Intel(R) Core(TM) i7-8700 CPU @ 3.20GHz Processor#8 speed: unknown Processor#8 description: Intel(R) Core(TM) i7-8700 CPU @ 3.20GHz Processor#9 speed: unknown Processor#9 description: Intel(R) Core(TM) i7-8700 CPU @ 3.20GHz Processor#10 speed: unknown Processor#10 description: Intel(R) Core(TM) i7-8700 CPU @ 3.20GHz Processor#11 speed: unknown Processor#11 description: Intel(R) Core(TM) i7-8700 CPU @ 3.20GHz Memory size: 16325 MByte Memory available: 6746 MByte Operating system: Windows 10 Operating system version: 10.0.19041 2021-06-11 22:24:59 (7104): Command: VBoxManage -q showvminfo "boinc_532cea6b561edab0" --machinereadable Exit Code: -2135228415 Output: VBoxManage.exe: error: Could not find a registered machine named 'boinc_532cea6b561edab0' VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2715 of file VBoxManageInfo.cpp 2021-06-11 22:24:59 (7104): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\2/vm_image.vdi" Exit Code: -2135228412 Output: VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\2\vm_image.vdi' (VERR_FILE_NOT_FOUND) VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp 2021-06-11 22:25:01 (7104): Command: VBoxManage -q createvm --name "boinc_532cea6b561edab0" --basefolder "C:\ProgramData\BOINC\slots\2" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_532cea6b561edab0' is created and registered. UUID: 5c375ef8-e6c5-42c0-85e0-0baf6563a1b6 Settings file: 'C:\ProgramData\BOINC\slots\2\boinc_532cea6b561edab0\boinc_532cea6b561edab0.vbox' 2021-06-11 22:25:01 (7104): Command: VBoxManage -q modifyvm "boinc_532cea6b561edab0" --description "08368315_33_0" Exit Code: 0 Output: 2021-06-11 22:25:01 (7104): Command: VBoxManage -q modifyvm "boinc_532cea6b561edab0" --memory 3072 Exit Code: 0 Output: 2021-06-11 22:25:02 (7104): Command: VBoxManage -q modifyvm "boinc_532cea6b561edab0" --cpus 1 Exit Code: 0 Output: 2021-06-11 22:25:03 (7104): Command: VBoxManage -q modifyvm "boinc_532cea6b561edab0" --acpi on --ioapic on Exit Code: 0 Output: 2021-06-11 22:25:04 (7104): Command: VBoxManage -q modifyvm "boinc_532cea6b561edab0" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2021-06-11 22:25:05 (7104): Command: VBoxManage -q modifyvm "boinc_532cea6b561edab0" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2021-06-11 22:25:09 (7104): Command: VBoxManage -q modifyvm "boinc_532cea6b561edab0" --cableconnected1 on Exit Code: 0 Output: 2021-06-11 22:25:16 (7104): Command: VBoxManage -q modifyvm "boinc_532cea6b561edab0" --usb off Exit Code: 0 Output: 2021-06-11 22:25:18 (7104): Command: VBoxManage -q modifyvm "boinc_532cea6b561edab0" --uart1 off --uart2 off Exit Code: 0 Output: 2021-06-11 22:25:19 (7104): Command: VBoxManage -q modifyvm "boinc_532cea6b561edab0" --lpt1 off --lpt2 off Exit Code: 0 Output: 2021-06-11 22:25:21 (7104): Command: VBoxManage -q modifyvm "boinc_532cea6b561edab0" --audio none Exit Code: 0 Output: 2021-06-11 22:25:22 (7104): Command: VBoxManage -q modifyvm "boinc_532cea6b561edab0" --clipboard disabled Exit Code: 0 Output: 2021-06-11 22:25:23 (7104): Command: VBoxManage -q modifyvm "boinc_532cea6b561edab0" --draganddrop disabled Exit Code: 0 Output: 2021-06-11 22:25:23 (7104): Command: VBoxManage -q storagectl "boinc_532cea6b561edab0" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2021-06-11 22:25:23 (7104): Command: VBoxManage -q storageattach "boinc_532cea6b561edab0" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\ProgramData\BOINC\slots\2/vm_isocontext.iso" Exit Code: 0 Output: 2021-06-11 22:25:23 (7104): Command: VBoxManage -q storageattach "boinc_532cea6b561edab0" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2021-06-11 22:25:24 (7104): Command: VBoxManage -q bandwidthctl "boinc_532cea6b561edab0" add "boinc_532cea6b561edab0_net" --type network --limit 1024G Exit Code: 0 Output: 2021-06-11 22:25:24 (7104): Command: VBoxManage -q sharedfolder add "boinc_532cea6b561edab0" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\2/shared" Exit Code: 0 Output: 2021-06-11 22:25:26 (7104): Command: VBoxManage -q startvm "boinc_532cea6b561edab0" --type headless Exit Code: -2147467259 Output: Waiting for VM "boinc_532cea6b561edab0" to power on... VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2021-06-11 22:25:26 (7104): Command: VBoxManage -q snapshot "boinc_532cea6b561edab0" list Exit Code: -108 Output: This machine does not have any snapshots 2021-06-11 22:25:26 (7104): Command: VBoxManage -q bandwidthctl "boinc_532cea6b561edab0" remove "boinc_532cea6b561edab0_net" Exit Code: 0 Output: VBoxManage.exe: error: Bandwidth groups cannot be deleted while the VM is running 2021-06-11 22:25:27 (7104): Command: VBoxManage -q unregistervm "boinc_532cea6b561edab0" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 2021-06-11 22:25:27 (7104): Command: VBoxManage -q closemedium dvd "C:\ProgramData\BOINC\slots\2/vm_isocontext.iso" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 22:25:35 (7104): called boinc_finish(-2147467259) </stderr_txt> ]]>
©2024 COPYRIGHT 2017-2018 NCN