Task 10464398

Name 08368304_22_1
Workunit 8130347
Created 12 Jun 2021, 14:59:09 UTC
Sent 12 Jun 2021, 15:02:35 UTC
Report deadline 17 Jun 2021, 15:02:35 UTC
Received 13 Jun 2021, 16:43:04 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status -2147467259 (0x80004005) Unknown error code
Computer ID 11360
Run time 22 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 4.47 GFLOPS
Application version boinc2docker v1.14 (vbox64_mt)
windows_x86_64
Peak working set size 10.96 MB
Peak swap size 6.22 MB
Peak disk usage 228.57 MB

Stderr output

<core_client_version>7.16.11</core_client_version>
<![CDATA[
<message>
Unspecified error
 (0x80004005) - exit code 2147500037 (0x80004005)</message>
<stderr_txt>
2021-06-12 10:07:42 (18356): Detected: vboxwrapper 26202
2021-06-12 10:07:42 (18356): Detected: BOINC client v7.16.11
2021-06-12 10:07:42 (18356): Detected: VirtualBox VboxManage Interface (Version: 6.1.12)
2021-06-12 10:07:43 (18356): Create VM. (boinc_46cf87bbc80e4474, slot#1)
2021-06-12 10:07:43 (18356): Updating drive controller type and model for desired configuration.
2021-06-12 10:07:44 (18356): Setting Memory Size for VM. (3072MB)
2021-06-12 10:07:44 (18356): Setting CPU Count for VM. (1)
2021-06-12 10:07:44 (18356): Setting Chipset Options for VM.
2021-06-12 10:07:45 (18356): Setting Boot Options for VM.
2021-06-12 10:07:45 (18356): Setting Network Configuration for NAT.
2021-06-12 10:07:45 (18356): Enabling VM Network Access.
2021-06-12 10:07:45 (18356): Disabling USB Support for VM.
2021-06-12 10:07:46 (18356): Disabling COM Port Support for VM.
2021-06-12 10:07:46 (18356): Disabling LPT Port Support for VM.
2021-06-12 10:07:46 (18356): Disabling Audio Support for VM.
2021-06-12 10:07:46 (18356): Disabling Clipboard Support for VM.
2021-06-12 10:07:47 (18356): Disabling Drag and Drop Support for VM.
2021-06-12 10:07:47 (18356): Adding storage controller(s) to VM.
2021-06-12 10:07:47 (18356): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso)
2021-06-12 10:07:48 (18356): Adding VirtualBox Guest Additions to VM.
2021-06-12 10:07:48 (18356): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2021-06-12 10:07:48 (18356): Enabling shared directory for VM.
2021-06-12 10:07:49 (18356): Starting VM using VBoxManage interface. (boinc_46cf87bbc80e4474, slot#1)
2021-06-12 10:07:51 (18356): Error in start VM for VM: -2147467259
Command:
VBoxManage -q startvm "boinc_46cf87bbc80e4474" --type headless
Output:
Waiting for VM "boinc_46cf87bbc80e4474" to power on...
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole

2021-06-12 10:07:51 (18356): VM failed to start.
2021-06-12 10:07:51 (18356): Could not start 
2021-06-12 10:07:51 (18356): ERROR: VM failed to start
2021-06-12 10:07:51 (18356): Powering off VM.
2021-06-12 10:07:51 (18356): Deregistering VM. (boinc_46cf87bbc80e4474, slot#1)
2021-06-12 10:07:51 (18356): Removing network bandwidth throttle group from VM.
2021-06-12 10:07:51 (18356): Removing VM from VirtualBox.
2021-06-12 10:07:51 (18356): Removing virtual ISO 9660 disk from VirtualBox.

    Hypervisor System Log:

00:01:55.023946          Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_507800e6c86e487c\boinc_507800e6c86e487c.vbox" with version "1.16-windows"
00:01:55.124462          Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_58ed63b0908e46ec\boinc_58ed63b0908e46ec.vbox" with version "1.16-windows"
00:01:55.214358          Launched VM: 61947120 pid: 4808 (0x12c8) frontend: headless name: boinc_4e380f929c29f9ad
00:01:55.296711          Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_507800e6c86e487c\boinc_507800e6c86e487c.vbox" with version "1.16-windows"
00:01:55.385654          Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_58ed63b0908e46ec\boinc_58ed63b0908e46ec.vbox" with version "1.16-windows"
00:01:55.554517          Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_507800e6c86e487c\boinc_507800e6c86e487c.vbox" with version "1.16-windows"
00:01:55.651459          Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_58ed63b0908e46ec\boinc_58ed63b0908e46ec.vbox" with version "1.16-windows"
00:01:55.818161          Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_507800e6c86e487c\boinc_507800e6c86e487c.vbox" with version "1.16-windows"
00:01:55.913186          Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_58ed63b0908e46ec\boinc_58ed63b0908e46ec.vbox" with version "1.16-windows"
00:01:56.087042          Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_507800e6c86e487c\boinc_507800e6c86e487c.vbox" with version "1.16-windows"
00:01:56.227746          Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_58ed63b0908e46ec\boinc_58ed63b0908e46ec.vbox" with version "1.16-windows"
00:01:56.350658          Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_507800e6c86e487c\boinc_507800e6c86e487c.vbox" with version "1.16-windows"
00:01:56.438776          Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_58ed63b0908e46ec\boinc_58ed63b0908e46ec.vbox" with version "1.16-windows"
00:01:56.611768          Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_507800e6c86e487c\boinc_507800e6c86e487c.vbox" with version "1.16-windows"
00:01:56.696457          Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_58ed63b0908e46ec\boinc_58ed63b0908e46ec.vbox" with version "1.16-windows"
00:01:56.862243          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:01:56.863249          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:01:56.863377          Saving settings file "C:\Users\Owner\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:01:56.869560          Saving settings file "C:\Users\Owner\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:01:56.874792          Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_507800e6c86e487c\boinc_507800e6c86e487c.vbox" with version "1.16-windows"
00:01:56.948904          Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_58ed63b0908e46ec\boinc_58ed63b0908e46ec.vbox" with version "1.16-windows"
00:01:57.120350          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:01:57.120666          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:01:57.121057          Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_507800e6c86e487c\boinc_507800e6c86e487c.vbox" with version "1.16-windows"
00:01:57.201467          Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_58ed63b0908e46ec\boinc_58ed63b0908e46ec.vbox" with version "1.16-windows"
00:01:57.339810          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_4e380f929c29f9ad\boinc_4e380f929c29f9ad.vbox" with version "1.16-windows"
00:01:57.379892          Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_507800e6c86e487c\boinc_507800e6c86e487c.vbox" with version "1.16-windows"
00:01:57.412816          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:01:57.461097          Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_58ed63b0908e46ec\boinc_58ed63b0908e46ec.vbox" with version "1.16-windows"
00:01:57.638725          Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_507800e6c86e487c\boinc_507800e6c86e487c.vbox" with version "1.16-windows"
00:01:57.734854          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:01:57.735901          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:01:57.736029          Saving settings file "C:\Users\Owner\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:01:57.741632          Saving settings file "C:\Users\Owner\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:01:57.746736          Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_58ed63b0908e46ec\boinc_58ed63b0908e46ec.vbox" with version "1.16-windows"
00:01:57.751755          Saving settings file "C:\Users\Owner\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:01:57.902998          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:01:57.903101          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:01:57.908345          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:01:57.989647          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:01:57.989970          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:01:57.990437          Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_58ed63b0908e46ec\boinc_58ed63b0908e46ec.vbox" with version "1.16-windows"
00:01:58.152058          Launched VM: 61555392 pid: 17956 (0x4624) frontend: headless name: boinc_507800e6c86e487c
00:01:58.249363          Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_58ed63b0908e46ec\boinc_58ed63b0908e46ec.vbox" with version "1.16-windows"
00:01:58.513313          Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_58ed63b0908e46ec\boinc_58ed63b0908e46ec.vbox" with version "1.16-windows"

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

Devices per SCSI Port:   1
Maximum SAS PIIX3 Controllers:   1
Maximum SAS ICH9 Controllers:    8
Maximum SAS Port count:          255
Maximum Devices per SAS Port:    1
Maximum NVMe PIIX3 Controllers:  1
Maximum NVMe ICH9 Controllers:   8
Maximum NVMe Port count:         255
Maximum Devices per NVMe Port:   1
Maximum virtio-scsi PIIX3 Controllers:  1
Maximum virtio-scsi ICH9 Controllers:   8
Maximum virtio-scsi Port count:         256
Maximum Devices per virtio-scsi Port:   1
Maximum PIIX3 Floppy Controllers:1
Maximum ICH9 Floppy Controllers: 1
Maximum Floppy Port count:       1
Maximum Devices per Floppy Port: 2
Default machine folder:          C:\Users\Owner\VirtualBox VMs
Raw-mode Supported:              no
Exclusive HW virtualization use: off
Default hard disk format:        VDI
VRDE auth library:               VBoxAuth
Webservice auth. library:        VBoxAuth
Remote desktop ExtPack:          
Log history count:               3
Default frontend:                
Default audio driver:            DirectSound
Autostart database path:         
Default Guest Additions ISO:     C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso
Logging Level:                   all
Proxy Mode:                      System
Proxy URL:                       

2021-06-12 10:07:43 (18356): 
Command: VBoxManage -q list hostinfo 
Exit Code: 0
Output:
Host Information:

Host time: 2021-06-12T15:07:42.828000000Z
Processor online count: 6
Processor count: 6
Processor online core count: 6
Processor core count: 6
Processor supports HW virtualization: no
Processor supports PAE: yes
Processor supports long mode: yes
Processor supports nested paging: no
Processor supports unrestricted guest: no
Processor supports nested HW virtualization: no
Processor#0 speed: unknown
Processor#0 description: Intel(R) Core(TM) i5-8400 CPU @ 2.80GHz
Processor#1 speed: unknown
Processor#1 description: Intel(R) Core(TM) i5-8400 CPU @ 2.80GHz
Processor#2 speed: unknown
Processor#2 description: Intel(R) Core(TM) i5-8400 CPU @ 2.80GHz
Processor#3 speed: unknown
Processor#3 description: Intel(R) Core(TM) i5-8400 CPU @ 2.80GHz
Processor#4 speed: unknown
Processor#4 description: Intel(R) Core(TM) i5-8400 CPU @ 2.80GHz
Processor#5 speed: unknown
Processor#5 description: Intel(R) Core(TM) i5-8400 CPU @ 2.80GHz
Memory size: 16303 MByte
Memory available: 8410 MByte
Operating system: Windows 10
Operating system version: 10.0.19041

2021-06-12 10:07:43 (18356): 
Command: VBoxManage -q showvminfo "boinc_46cf87bbc80e4474" --machinereadable 
Exit Code: -2135228415
Output:
VBoxManage.exe: error: Could not find a registered machine named 'boinc_46cf87bbc80e4474'
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown
VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2715 of file VBoxManageInfo.cpp

2021-06-12 10:07:43 (18356): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\1/vm_image.vdi" 
Exit Code: -2135228412
Output:
VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\1\vm_image.vdi' (VERR_FILE_NOT_FOUND)
VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp

2021-06-12 10:07:44 (18356): 
Command: VBoxManage -q createvm --name "boinc_46cf87bbc80e4474" --basefolder "C:\ProgramData\BOINC\slots\1" --ostype "Linux26_64" --register
Exit Code: 0
Output:
Virtual machine 'boinc_46cf87bbc80e4474' is created and registered.
UUID: 510b1866-b16a-4762-8d22-d92c9ba8ec1c
Settings file: 'C:\ProgramData\BOINC\slots\1\boinc_46cf87bbc80e4474\boinc_46cf87bbc80e4474.vbox'

2021-06-12 10:07:44 (18356): 
Command: VBoxManage -q modifyvm "boinc_46cf87bbc80e4474" --description "08368304_22_1" 
Exit Code: 0
Output:

2021-06-12 10:07:44 (18356): 
Command: VBoxManage -q modifyvm "boinc_46cf87bbc80e4474" --memory 3072 
Exit Code: 0
Output:

2021-06-12 10:07:44 (18356): 
Command: VBoxManage -q modifyvm "boinc_46cf87bbc80e4474" --cpus 1 
Exit Code: 0
Output:

2021-06-12 10:07:45 (18356): 
Command: VBoxManage -q modifyvm "boinc_46cf87bbc80e4474" --acpi on --ioapic on 
Exit Code: 0
Output:

2021-06-12 10:07:45 (18356): 
Command: VBoxManage -q modifyvm "boinc_46cf87bbc80e4474" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2021-06-12 10:07:45 (18356): 
Command: VBoxManage -q modifyvm "boinc_46cf87bbc80e4474" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2021-06-12 10:07:45 (18356): 
Command: VBoxManage -q modifyvm "boinc_46cf87bbc80e4474" --cableconnected1 on 
Exit Code: 0
Output:

2021-06-12 10:07:46 (18356): 
Command: VBoxManage -q modifyvm "boinc_46cf87bbc80e4474" --usb off 
Exit Code: 0
Output:

2021-06-12 10:07:46 (18356): 
Command: VBoxManage -q modifyvm "boinc_46cf87bbc80e4474" --uart1 off --uart2 off 
Exit Code: 0
Output:

2021-06-12 10:07:46 (18356): 
Command: VBoxManage -q modifyvm "boinc_46cf87bbc80e4474" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2021-06-12 10:07:46 (18356): 
Command: VBoxManage -q modifyvm "boinc_46cf87bbc80e4474" --audio none 
Exit Code: 0
Output:

2021-06-12 10:07:47 (18356): 
Command: VBoxManage -q modifyvm "boinc_46cf87bbc80e4474" --clipboard disabled 
Exit Code: 0
Output:

2021-06-12 10:07:47 (18356): 
Command: VBoxManage -q modifyvm "boinc_46cf87bbc80e4474" --draganddrop disabled 
Exit Code: 0
Output:

2021-06-12 10:07:47 (18356): 
Command: VBoxManage -q storagectl "boinc_46cf87bbc80e4474" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2021-06-12 10:07:48 (18356): 
Command: VBoxManage -q storageattach "boinc_46cf87bbc80e4474" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\ProgramData\BOINC\slots\1/vm_isocontext.iso" 
Exit Code: 0
Output:

2021-06-12 10:07:48 (18356): 
Command: VBoxManage -q storageattach "boinc_46cf87bbc80e4474" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2021-06-12 10:07:48 (18356): 
Command: VBoxManage -q bandwidthctl "boinc_46cf87bbc80e4474" add "boinc_46cf87bbc80e4474_net" --type network --limit 1024G 
Exit Code: 0
Output:

2021-06-12 10:07:48 (18356): 
Command: VBoxManage -q sharedfolder add "boinc_46cf87bbc80e4474" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\1/shared"
Exit Code: 0
Output:

2021-06-12 10:07:51 (18356): 
Command: VBoxManage -q startvm "boinc_46cf87bbc80e4474" --type headless
Exit Code: -2147467259
Output:
Waiting for VM "boinc_46cf87bbc80e4474" to power on...
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole

2021-06-12 10:07:51 (18356): 
Command: VBoxManage -q snapshot "boinc_46cf87bbc80e4474" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2021-06-12 10:07:51 (18356): 
Command: VBoxManage -q bandwidthctl "boinc_46cf87bbc80e4474" remove "boinc_46cf87bbc80e4474_net" 
Exit Code: 0
Output:
VBoxManage.exe: error: Bandwidth groups cannot be deleted while the VM is running

2021-06-12 10:07:51 (18356): 
Command: VBoxManage -q unregistervm "boinc_46cf87bbc80e4474" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

2021-06-12 10:07:52 (18356): 
Command: VBoxManage -q closemedium dvd "C:\ProgramData\BOINC\slots\1/vm_isocontext.iso" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

10:08:02 (18356): called boinc_finish(-2147467259)

</stderr_txt>
]]>


©2024 COPYRIGHT 2017-2018 NCN