Task 10491351

Name 08370552_36_0
Workunit 8199109
Created 12 Jun 2021, 22:09:28 UTC
Sent 13 Jun 2021, 0:55:47 UTC
Report deadline 18 Jun 2021, 0:55:47 UTC
Received 14 Jun 2021, 21:24:15 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status -2147467259 (0x80004005) Unknown error code
Computer ID 9481
Run time 19 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 1.91 GFLOPS
Application version boinc2docker v1.14 (vbox64_mt)
windows_x86_64
Peak working set size 11.49 MB
Peak swap size 6.22 MB
Peak disk usage 499.00 MB

Stderr output

<core_client_version>7.16.11</core_client_version>
<![CDATA[
<message>
Unspecified error
 (0x80004005) - exit code 2147500037 (0x80004005)</message>
<stderr_txt>
2021-06-12 17:59:07 (8600): Detected: vboxwrapper 26202
2021-06-12 17:59:07 (8600): Detected: BOINC client v7.16.11
2021-06-12 17:59:08 (8600): Detected: VirtualBox VboxManage Interface (Version: 6.1.12)
2021-06-12 17:59:09 (8600): Create VM. (boinc_87d74df900f46e70, slot#6)
2021-06-12 17:59:09 (8600): Updating drive controller type and model for desired configuration.
2021-06-12 17:59:09 (8600): Setting Memory Size for VM. (3072MB)
2021-06-12 17:59:09 (8600): Setting CPU Count for VM. (1)
2021-06-12 17:59:10 (8600): Setting Chipset Options for VM.
2021-06-12 17:59:10 (8600): Setting Boot Options for VM.
2021-06-12 17:59:10 (8600): Setting Network Configuration for NAT.
2021-06-12 17:59:10 (8600): Enabling VM Network Access.
2021-06-12 17:59:11 (8600): Disabling USB Support for VM.
2021-06-12 17:59:11 (8600): Disabling COM Port Support for VM.
2021-06-12 17:59:11 (8600): Disabling LPT Port Support for VM.
2021-06-12 17:59:11 (8600): Disabling Audio Support for VM.
2021-06-12 17:59:12 (8600): Disabling Clipboard Support for VM.
2021-06-12 17:59:12 (8600): Disabling Drag and Drop Support for VM.
2021-06-12 17:59:12 (8600): Adding storage controller(s) to VM.
2021-06-12 17:59:13 (8600): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso)
2021-06-12 17:59:13 (8600): Adding VirtualBox Guest Additions to VM.
2021-06-12 17:59:13 (8600): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2021-06-12 17:59:13 (8600): Enabling shared directory for VM.
2021-06-12 17:59:15 (8600): Starting VM using VBoxManage interface. (boinc_87d74df900f46e70, slot#6)
2021-06-12 17:59:18 (8600): Error in start VM for VM: -2147467259
Command:
VBoxManage -q startvm "boinc_87d74df900f46e70" --type headless
Output:
Waiting for VM "boinc_87d74df900f46e70" to power on...
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: AMD-V is disabled in the BIOS (or by the host OS) (VERR_SVM_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole

2021-06-12 17:59:18 (8600): VM failed to start.
2021-06-12 17:59:18 (8600): Could not start 
2021-06-12 17:59:18 (8600): ERROR: VM failed to start
2021-06-12 17:59:18 (8600): Powering off VM.
2021-06-12 17:59:18 (8600): Deregistering VM. (boinc_87d74df900f46e70, slot#6)
2021-06-12 17:59:18 (8600): Removing network bandwidth throttle group from VM.
2021-06-12 17:59:18 (8600): Removing VM from VirtualBox.
2021-06-12 17:59:19 (8600): Removing virtual ISO 9660 disk from VirtualBox.

    Hypervisor System Log:

00:00:06.263843          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:06.401605          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.401817          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.402258          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.402554          Saving settings file "C:\Users\stal0\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:06.402634          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.405842          Saving settings file "C:\Users\stal0\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:06.406009          Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_83d52f39a33311f5\boinc_83d52f39a33311f5.vbox" with version "1.16-windows"
00:00:06.408397          Saving settings file "C:\ProgramData\BOINC\slots\6\boinc_87d74df900f46e70\boinc_87d74df900f46e70.vbox" with version "1.16-windows"
00:00:06.417359          Launched VM: 70780640 pid: 9436 (0x24dc) frontend: headless name: boinc_80a547ed608b11ed
00:00:06.508683          Launched VM: 70585904 pid: 8228 (0x2024) frontend: headless name: boinc_8216f490e3420aad
00:00:06.654220          Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_83d52f39a33311f5\boinc_83d52f39a33311f5.vbox" with version "1.16-windows"
00:00:06.654578          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.654939          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.655339          Saving settings file "C:\ProgramData\BOINC\slots\6\boinc_87d74df900f46e70\boinc_87d74df900f46e70.vbox" with version "1.16-windows"
00:00:06.924572          Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_83d52f39a33311f5\boinc_83d52f39a33311f5.vbox" with version "1.16-windows"
00:00:06.924726          Saving settings file "C:\ProgramData\BOINC\slots\6\boinc_87d74df900f46e70\boinc_87d74df900f46e70.vbox" with version "1.16-windows"
00:00:07.180905          Saving settings file "C:\ProgramData\BOINC\slots\6\boinc_87d74df900f46e70\boinc_87d74df900f46e70.vbox" with version "1.16-windows"
00:00:07.184774          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.184979          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.192885          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:08.280552          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.280685          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.286364          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:08.706321          Launched VM: 70871344 pid: 10304 (0x2840) frontend: headless name: boinc_83d52f39a33311f5
00:00:08.861478          Launched VM: 70860768 pid: 6432 (0x1920) frontend: headless name: boinc_87d74df900f46e70
00:00:08.921555 Watcher  ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={The virtual machine 'boinc_8216f490e3420aad' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\7\boinc_8216f490e3420aad\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0
00:00:08.922073 Watcher  Reaper: Pid 8228 (2024) exited normally: 1 (0x1)
00:00:08.979908          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:09.024604          Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_8216f490e3420aad\boinc_8216f490e3420aad.vbox" with version "1.16-windows"
00:00:09.278464          Saving settings file "C:\Users\stal0\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:09.368254          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_80a547ed608b11ed\boinc_80a547ed608b11ed.vbox" with version "1.16-windows"
00:00:09.421265          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:10.560490          Saving settings file "C:\Users\stal0\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:11.582998          Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_83d52f39a33311f5\boinc_83d52f39a33311f5.vbox" with version "1.16-windows"
00:00:11.634231          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:11.927881          Saving settings file "C:\Users\stal0\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:12.003859          Saving settings file "C:\ProgramData\BOINC\slots\6\boinc_87d74df900f46e70\boinc_87d74df900f46e70.vbox" with version "1.16-windows"
00:00:12.054657          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:12.358840          Saving settings file "C:\Users\stal0\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:17.621317 main     VirtualBox: object deletion starts
00:00:17.621715 main     HostDnsMonitor: shutting down ...
00:00:17.621732 main     HostDnsMonitor: shut down
00:00:17.625099 Watcher  ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0
00:00:17.625203 main     VirtualBox: object deleted

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

ices per virtio-scsi Port:   1
Maximum PIIX3 Floppy Controllers:1
Maximum ICH9 Floppy Controllers: 1
Maximum Floppy Port count:       1
Maximum Devices per Floppy Port: 2
Default machine folder:          C:\Users\stal0\VirtualBox VMs
Raw-mode Supported:              no
Exclusive HW virtualization use: off
Default hard disk format:        VDI
VRDE auth library:               VBoxAuth
Webservice auth. library:        VBoxAuth
Remote desktop ExtPack:          
Log history count:               3
Default frontend:                
Default audio driver:            DirectSound
Autostart database path:         
Default Guest Additions ISO:     C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso
Logging Level:                   all
Proxy Mode:                      System
Proxy URL:                       

2021-06-12 17:59:08 (8600): 
Command: VBoxManage -q list hostinfo 
Exit Code: 0
Output:
Host Information:

Host time: 2021-06-13T00:59:08.413000000Z
Processor online count: 12
Processor count: 12
Processor online core count: 6
Processor core count: 6
Processor supports HW virtualization: no
Processor supports PAE: yes
Processor supports long mode: yes
Processor supports nested paging: no
Processor supports unrestricted guest: no
Processor supports nested HW virtualization: no
Processor#0 speed: unknown
Processor#0 description: AMD Ryzen 5 3600 6-Core Processor
Processor#1 speed: unknown
Processor#1 description: AMD Ryzen 5 3600 6-Core Processor
Processor#2 speed: unknown
Processor#2 description: AMD Ryzen 5 3600 6-Core Processor
Processor#3 speed: unknown
Processor#3 description: AMD Ryzen 5 3600 6-Core Processor
Processor#4 speed: unknown
Processor#4 description: AMD Ryzen 5 3600 6-Core Processor
Processor#5 speed: unknown
Processor#5 description: AMD Ryzen 5 3600 6-Core Processor
Processor#6 speed: unknown
Processor#6 description: AMD Ryzen 5 3600 6-Core Processor
Processor#7 speed: unknown
Processor#7 description: AMD Ryzen 5 3600 6-Core Processor
Processor#8 speed: unknown
Processor#8 description: AMD Ryzen 5 3600 6-Core Processor
Processor#9 speed: unknown
Processor#9 description: AMD Ryzen 5 3600 6-Core Processor
Processor#10 speed: unknown
Processor#10 description: AMD Ryzen 5 3600 6-Core Processor
Processor#11 speed: unknown
Processor#11 description: AMD Ryzen 5 3600 6-Core Processor
Memory size: 16291 MByte
Memory available: 9983 MByte
Operating system: Windows 10
Operating system version: 10.0.19042

2021-06-12 17:59:08 (8600): 
Command: VBoxManage -q showvminfo "boinc_87d74df900f46e70" --machinereadable 
Exit Code: -2135228415
Output:
VBoxManage.exe: error: Could not find a registered machine named 'boinc_87d74df900f46e70'
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown
VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2715 of file VBoxManageInfo.cpp

2021-06-12 17:59:09 (8600): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\6/vm_image.vdi" 
Exit Code: -2135228412
Output:
VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\6\vm_image.vdi' (VERR_FILE_NOT_FOUND)
VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp

2021-06-12 17:59:09 (8600): 
Command: VBoxManage -q createvm --name "boinc_87d74df900f46e70" --basefolder "C:\ProgramData\BOINC\slots\6" --ostype "Linux26_64" --register
Exit Code: 0
Output:
Virtual machine 'boinc_87d74df900f46e70' is created and registered.
UUID: e148d6a9-5a99-4207-8445-283d205e983f
Settings file: 'C:\ProgramData\BOINC\slots\6\boinc_87d74df900f46e70\boinc_87d74df900f46e70.vbox'

2021-06-12 17:59:09 (8600): 
Command: VBoxManage -q modifyvm "boinc_87d74df900f46e70" --description "08370552_36_0" 
Exit Code: 0
Output:

2021-06-12 17:59:09 (8600): 
Command: VBoxManage -q modifyvm "boinc_87d74df900f46e70" --memory 3072 
Exit Code: 0
Output:

2021-06-12 17:59:10 (8600): 
Command: VBoxManage -q modifyvm "boinc_87d74df900f46e70" --cpus 1 
Exit Code: 0
Output:

2021-06-12 17:59:10 (8600): 
Command: VBoxManage -q modifyvm "boinc_87d74df900f46e70" --acpi on --ioapic on 
Exit Code: 0
Output:

2021-06-12 17:59:10 (8600): 
Command: VBoxManage -q modifyvm "boinc_87d74df900f46e70" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2021-06-12 17:59:10 (8600): 
Command: VBoxManage -q modifyvm "boinc_87d74df900f46e70" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2021-06-12 17:59:11 (8600): 
Command: VBoxManage -q modifyvm "boinc_87d74df900f46e70" --cableconnected1 on 
Exit Code: 0
Output:

2021-06-12 17:59:11 (8600): 
Command: VBoxManage -q modifyvm "boinc_87d74df900f46e70" --usb off 
Exit Code: 0
Output:

2021-06-12 17:59:11 (8600): 
Command: VBoxManage -q modifyvm "boinc_87d74df900f46e70" --uart1 off --uart2 off 
Exit Code: 0
Output:

2021-06-12 17:59:11 (8600): 
Command: VBoxManage -q modifyvm "boinc_87d74df900f46e70" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2021-06-12 17:59:12 (8600): 
Command: VBoxManage -q modifyvm "boinc_87d74df900f46e70" --audio none 
Exit Code: 0
Output:

2021-06-12 17:59:12 (8600): 
Command: VBoxManage -q modifyvm "boinc_87d74df900f46e70" --clipboard disabled 
Exit Code: 0
Output:

2021-06-12 17:59:12 (8600): 
Command: VBoxManage -q modifyvm "boinc_87d74df900f46e70" --draganddrop disabled 
Exit Code: 0
Output:

2021-06-12 17:59:13 (8600): 
Command: VBoxManage -q storagectl "boinc_87d74df900f46e70" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2021-06-12 17:59:13 (8600): 
Command: VBoxManage -q storageattach "boinc_87d74df900f46e70" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\ProgramData\BOINC\slots\6/vm_isocontext.iso" 
Exit Code: 0
Output:

2021-06-12 17:59:13 (8600): 
Command: VBoxManage -q storageattach "boinc_87d74df900f46e70" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2021-06-12 17:59:13 (8600): 
Command: VBoxManage -q bandwidthctl "boinc_87d74df900f46e70" add "boinc_87d74df900f46e70_net" --type network --limit 1024G 
Exit Code: 0
Output:

2021-06-12 17:59:14 (8600): 
Command: VBoxManage -q sharedfolder add "boinc_87d74df900f46e70" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\6/shared"
Exit Code: 0
Output:

2021-06-12 17:59:18 (8600): 
Command: VBoxManage -q startvm "boinc_87d74df900f46e70" --type headless
Exit Code: -2147467259
Output:
Waiting for VM "boinc_87d74df900f46e70" to power on...
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: AMD-V is disabled in the BIOS (or by the host OS) (VERR_SVM_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole

2021-06-12 17:59:18 (8600): 
Command: VBoxManage -q snapshot "boinc_87d74df900f46e70" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2021-06-12 17:59:18 (8600): 
Command: VBoxManage -q bandwidthctl "boinc_87d74df900f46e70" remove "boinc_87d74df900f46e70_net" 
Exit Code: 0
Output:
VBoxManage.exe: error: Bandwidth groups cannot be deleted while the VM is running

2021-06-12 17:59:19 (8600): 
Command: VBoxManage -q unregistervm "boinc_87d74df900f46e70" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

2021-06-12 17:59:19 (8600): 
Command: VBoxManage -q closemedium dvd "C:\ProgramData\BOINC\slots\6/vm_isocontext.iso" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

17:59:24 (8600): called boinc_finish(-2147467259)

</stderr_txt>
]]>


©2024 COPYRIGHT 2017-2018 NCN