Task 10511564

Name 08368819_08_1
Workunit 8145230
Created 13 Jun 2021, 6:14:06 UTC
Sent 13 Jun 2021, 6:17:16 UTC
Report deadline 18 Jun 2021, 6:17:16 UTC
Received 13 Jun 2021, 8:12:43 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status -2147467259 (0x80004005) Unknown error code
Computer ID 10651
Run time 21 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 3.93 GFLOPS
Application version boinc2docker v1.14 (vbox64_mt)
windows_x86_64
Peak working set size 9.98 MB
Peak swap size 2.09 MB
Peak disk usage 227.18 MB

Stderr output

<core_client_version>7.16.11</core_client_version>
<![CDATA[
<message>
Unspecified error
 (0x80004005) - exit code 2147500037 (0x80004005)</message>
<stderr_txt>
2021-06-13 02:30:00 (6908): Detected: vboxwrapper 26202
2021-06-13 02:30:00 (6908): Detected: BOINC client v7.16.11
2021-06-13 02:30:01 (6908): Detected: VirtualBox VboxManage Interface (Version: 6.1.12)
2021-06-13 02:30:02 (6908): Create VM. (boinc_75e6ebc617cf95ba, slot#2)
2021-06-13 02:30:02 (6908): Updating drive controller type and model for desired configuration.
2021-06-13 02:30:03 (6908): Setting Memory Size for VM. (3072MB)
2021-06-13 02:30:03 (6908): Setting CPU Count for VM. (1)
2021-06-13 02:30:03 (6908): Setting Chipset Options for VM.
2021-06-13 02:30:03 (6908): Setting Boot Options for VM.
2021-06-13 02:30:04 (6908): Setting Network Configuration for NAT.
2021-06-13 02:30:04 (6908): Enabling VM Network Access.
2021-06-13 02:30:04 (6908): Disabling USB Support for VM.
2021-06-13 02:30:04 (6908): Disabling COM Port Support for VM.
2021-06-13 02:30:05 (6908): Disabling LPT Port Support for VM.
2021-06-13 02:30:05 (6908): Disabling Audio Support for VM.
2021-06-13 02:30:05 (6908): Disabling Clipboard Support for VM.
2021-06-13 02:30:06 (6908): Disabling Drag and Drop Support for VM.
2021-06-13 02:30:06 (6908): Adding storage controller(s) to VM.
2021-06-13 02:30:06 (6908): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso)
2021-06-13 02:30:06 (6908): Adding VirtualBox Guest Additions to VM.
2021-06-13 02:30:07 (6908): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2021-06-13 02:30:07 (6908): Enabling shared directory for VM.
2021-06-13 02:30:08 (6908): Starting VM using VBoxManage interface. (boinc_75e6ebc617cf95ba, slot#2)
2021-06-13 02:30:11 (6908): Error in start VM for VM: -2147467259
Command:
VBoxManage -q startvm "boinc_75e6ebc617cf95ba" --type headless
Output:
Waiting for VM "boinc_75e6ebc617cf95ba" to power on...
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole

2021-06-13 02:30:12 (6908): VM failed to start.
2021-06-13 02:30:12 (6908): Could not start 
2021-06-13 02:30:12 (6908): ERROR: VM failed to start
2021-06-13 02:30:12 (6908): Powering off VM.
2021-06-13 02:30:12 (6908): Deregistering VM. (boinc_75e6ebc617cf95ba, slot#2)
2021-06-13 02:30:12 (6908): Removing network bandwidth throttle group from VM.
2021-06-13 02:30:12 (6908): Removing VM from VirtualBox.
2021-06-13 02:30:13 (6908): Removing virtual ISO 9660 disk from VirtualBox.

    Hypervisor System Log:

00:00:00.390250          netIfIsWireless: CreateFile on '\\.\{363DB734-2727-4479-89BA-3F4767567B3B}' failed with rcWin=2 (0x2) - ignoring
00:00:00.401793          HostDnsMonitor: initializing
00:00:00.412975          HostDnsMonitor: updating information
00:00:00.413019          HostDnsMonitor: old information
00:00:00.413020            no server entries
00:00:00.413021            no domain set
00:00:00.413022            no search string entries
00:00:00.413023          HostDnsMonitor: new information
00:00:00.413024            server 1: 192.168.0.1
00:00:00.413025            no domain set
00:00:00.413026            no search string entries
00:00:00.535162          SUPR0QueryVTCaps -> VERR_VMX_MSR_ALL_VMX_DISABLED
00:00:00.535906          VD: VDInit finished with VINF_SUCCESS
00:00:00.537484          VirtualBox: object created
00:00:01.039386          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={Could not find a registered machine named 'boinc_75e6ebc617cf95ba'}, preserve=false aResultDetail=0
00:00:01.302920          ERROR [COM]: aRC=VBOX_E_FILE_ERROR (0x80bb0004) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Could not find file for the medium 'C:\ProgramData\BOINC\slots\2\vm_image.vdi' (VERR_FILE_NOT_FOUND)}, preserve=false aResultDetail=-102
00:00:01.572127          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_75e6ebc617cf95ba\boinc_75e6ebc617cf95ba.vbox" with version "1.16-windows"
00:00:01.575079          Saving settings file "C:\Users\USER\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:01.855345          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_75e6ebc617cf95ba\boinc_75e6ebc617cf95ba.vbox" with version "1.16-windows"
00:00:02.150387          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_75e6ebc617cf95ba\boinc_75e6ebc617cf95ba.vbox" with version "1.16-windows"
00:00:02.414758          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_75e6ebc617cf95ba\boinc_75e6ebc617cf95ba.vbox" with version "1.16-windows"
00:00:02.695202          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_75e6ebc617cf95ba\boinc_75e6ebc617cf95ba.vbox" with version "1.16-windows"
00:00:02.964015          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_75e6ebc617cf95ba\boinc_75e6ebc617cf95ba.vbox" with version "1.16-windows"
00:00:03.238744          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_75e6ebc617cf95ba\boinc_75e6ebc617cf95ba.vbox" with version "1.16-windows"
00:00:03.491899          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_75e6ebc617cf95ba\boinc_75e6ebc617cf95ba.vbox" with version "1.16-windows"
00:00:03.795942          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_75e6ebc617cf95ba\boinc_75e6ebc617cf95ba.vbox" with version "1.16-windows"
00:00:04.060085          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_75e6ebc617cf95ba\boinc_75e6ebc617cf95ba.vbox" with version "1.16-windows"
00:00:04.333118          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_75e6ebc617cf95ba\boinc_75e6ebc617cf95ba.vbox" with version "1.16-windows"
00:00:04.605816          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_75e6ebc617cf95ba\boinc_75e6ebc617cf95ba.vbox" with version "1.16-windows"
00:00:04.890689          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_75e6ebc617cf95ba\boinc_75e6ebc617cf95ba.vbox" with version "1.16-windows"
00:00:05.166522          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_75e6ebc617cf95ba\boinc_75e6ebc617cf95ba.vbox" with version "1.16-windows"
00:00:05.434791          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_75e6ebc617cf95ba\boinc_75e6ebc617cf95ba.vbox" with version "1.16-windows"
00:00:05.700276          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:05.702678          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:05.702885          Saving settings file "C:\Users\USER\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:05.707341          Saving settings file "C:\Users\USER\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:05.711788          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_75e6ebc617cf95ba\boinc_75e6ebc617cf95ba.vbox" with version "1.16-windows"
00:00:06.006260          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.008263          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.008426          Saving settings file "C:\Users\USER\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:06.012308          Saving settings file "C:\Users\USER\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:06.016379          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_75e6ebc617cf95ba\boinc_75e6ebc617cf95ba.vbox" with version "1.16-windows"
00:00:06.273498          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_75e6ebc617cf95ba\boinc_75e6ebc617cf95ba.vbox" with version "1.16-windows"
00:00:06.547922          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_75e6ebc617cf95ba\boinc_75e6ebc617cf95ba.vbox" with version "1.16-windows"
00:00:06.819811          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.820093          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.831254          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:07.092821          Launched VM: 71941200 pid: 17456 (0x4430) frontend: headless name: boinc_75e6ebc617cf95ba
00:00:10.970794          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_75e6ebc617cf95ba\boinc_75e6ebc617cf95ba.vbox" with version "1.16-windows"
00:00:11.070482          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:11.409119          ERROR [COM]: aRC=VBOX_E_INVALID_OBJECT_STATE (0x80bb0007) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={Cannot unregister the machine 'boinc_75e6ebc617cf95ba' while it is locked}, preserve=false aResultDetail=0
00:00:12.702467          Saving settings file "C:\Users\USER\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:18.000394 main     VirtualBox: object deletion starts
00:00:18.001474 main     HostDnsMonitor: shutting down ...
00:00:18.001509 main     HostDnsMonitor: shut down
00:00:18.004265 Watcher  ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0
00:00:18.004554 main     VirtualBox: object deleted

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

ox VMs
Raw-mode Supported:              no
Exclusive HW virtualization use: off
Default hard disk format:        VDI
VRDE auth library:               VBoxAuth
Webservice auth. library:        VBoxAuth
Remote desktop ExtPack:          
Log history count:               3
Default frontend:                
Default audio driver:            DirectSound
Autostart database path:         
Default Guest Additions ISO:     C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso
Logging Level:                   all
Proxy Mode:                      System
Proxy URL:                       

2021-06-13 02:30:01 (6908): 
Command: VBoxManage -q list hostinfo 
Exit Code: 0
Output:
Host Information:

Host time: 2021-06-13T06:30:01.781000000Z
Processor online count: 8
Processor count: 8
Processor online core count: 4
Processor core count: 4
Processor supports HW virtualization: no
Processor supports PAE: yes
Processor supports long mode: yes
Processor supports nested paging: no
Processor supports unrestricted guest: no
Processor supports nested HW virtualization: no
Processor#0 speed: unknown
Processor#0 description: Intel(R) Core(TM) i7-3770 CPU @ 3.40GHz
Processor#1 speed: unknown
Processor#1 description: Intel(R) Core(TM) i7-3770 CPU @ 3.40GHz
Processor#2 speed: unknown
Processor#2 description: Intel(R) Core(TM) i7-3770 CPU @ 3.40GHz
Processor#3 speed: unknown
Processor#3 description: Intel(R) Core(TM) i7-3770 CPU @ 3.40GHz
Processor#4 speed: unknown
Processor#4 description: Intel(R) Core(TM) i7-3770 CPU @ 3.40GHz
Processor#5 speed: unknown
Processor#5 description: Intel(R) Core(TM) i7-3770 CPU @ 3.40GHz
Processor#6 speed: unknown
Processor#6 description: Intel(R) Core(TM) i7-3770 CPU @ 3.40GHz
Processor#7 speed: unknown
Processor#7 description: Intel(R) Core(TM) i7-3770 CPU @ 3.40GHz
Memory size: 16346 MByte
Memory available: 8609 MByte
Operating system: Windows 10
Operating system version: 10.0.19041

2021-06-13 02:30:02 (6908): 
Command: VBoxManage -q showvminfo "boinc_75e6ebc617cf95ba" --machinereadable 
Exit Code: -2135228415
Output:
VBoxManage.exe: error: Could not find a registered machine named 'boinc_75e6ebc617cf95ba'
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown
VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2715 of file VBoxManageInfo.cpp

2021-06-13 02:30:02 (6908): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\2/vm_image.vdi" 
Exit Code: -2135228412
Output:
VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\2\vm_image.vdi' (VERR_FILE_NOT_FOUND)
VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp

2021-06-13 02:30:02 (6908): 
Command: VBoxManage -q createvm --name "boinc_75e6ebc617cf95ba" --basefolder "C:\ProgramData\BOINC\slots\2" --ostype "Linux26_64" --register
Exit Code: 0
Output:
Virtual machine 'boinc_75e6ebc617cf95ba' is created and registered.
UUID: 78c80324-6dd7-49f3-91d8-b5648b6b04bb
Settings file: 'C:\ProgramData\BOINC\slots\2\boinc_75e6ebc617cf95ba\boinc_75e6ebc617cf95ba.vbox'

2021-06-13 02:30:03 (6908): 
Command: VBoxManage -q modifyvm "boinc_75e6ebc617cf95ba" --description "08368819_08_1" 
Exit Code: 0
Output:

2021-06-13 02:30:03 (6908): 
Command: VBoxManage -q modifyvm "boinc_75e6ebc617cf95ba" --memory 3072 
Exit Code: 0
Output:

2021-06-13 02:30:03 (6908): 
Command: VBoxManage -q modifyvm "boinc_75e6ebc617cf95ba" --cpus 1 
Exit Code: 0
Output:

2021-06-13 02:30:03 (6908): 
Command: VBoxManage -q modifyvm "boinc_75e6ebc617cf95ba" --acpi on --ioapic on 
Exit Code: 0
Output:

2021-06-13 02:30:04 (6908): 
Command: VBoxManage -q modifyvm "boinc_75e6ebc617cf95ba" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2021-06-13 02:30:04 (6908): 
Command: VBoxManage -q modifyvm "boinc_75e6ebc617cf95ba" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2021-06-13 02:30:04 (6908): 
Command: VBoxManage -q modifyvm "boinc_75e6ebc617cf95ba" --cableconnected1 on 
Exit Code: 0
Output:

2021-06-13 02:30:04 (6908): 
Command: VBoxManage -q modifyvm "boinc_75e6ebc617cf95ba" --usb off 
Exit Code: 0
Output:

2021-06-13 02:30:05 (6908): 
Command: VBoxManage -q modifyvm "boinc_75e6ebc617cf95ba" --uart1 off --uart2 off 
Exit Code: 0
Output:

2021-06-13 02:30:05 (6908): 
Command: VBoxManage -q modifyvm "boinc_75e6ebc617cf95ba" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2021-06-13 02:30:05 (6908): 
Command: VBoxManage -q modifyvm "boinc_75e6ebc617cf95ba" --audio none 
Exit Code: 0
Output:

2021-06-13 02:30:06 (6908): 
Command: VBoxManage -q modifyvm "boinc_75e6ebc617cf95ba" --clipboard disabled 
Exit Code: 0
Output:

2021-06-13 02:30:06 (6908): 
Command: VBoxManage -q modifyvm "boinc_75e6ebc617cf95ba" --draganddrop disabled 
Exit Code: 0
Output:

2021-06-13 02:30:06 (6908): 
Command: VBoxManage -q storagectl "boinc_75e6ebc617cf95ba" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2021-06-13 02:30:06 (6908): 
Command: VBoxManage -q storageattach "boinc_75e6ebc617cf95ba" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\ProgramData\BOINC\slots\2/vm_isocontext.iso" 
Exit Code: 0
Output:

2021-06-13 02:30:07 (6908): 
Command: VBoxManage -q storageattach "boinc_75e6ebc617cf95ba" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2021-06-13 02:30:07 (6908): 
Command: VBoxManage -q bandwidthctl "boinc_75e6ebc617cf95ba" add "boinc_75e6ebc617cf95ba_net" --type network --limit 1024G 
Exit Code: 0
Output:

2021-06-13 02:30:07 (6908): 
Command: VBoxManage -q sharedfolder add "boinc_75e6ebc617cf95ba" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\2/shared"
Exit Code: 0
Output:

2021-06-13 02:30:11 (6908): 
Command: VBoxManage -q startvm "boinc_75e6ebc617cf95ba" --type headless
Exit Code: -2147467259
Output:
Waiting for VM "boinc_75e6ebc617cf95ba" to power on...
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole

2021-06-13 02:30:12 (6908): 
Command: VBoxManage -q snapshot "boinc_75e6ebc617cf95ba" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2021-06-13 02:30:12 (6908): 
Command: VBoxManage -q bandwidthctl "boinc_75e6ebc617cf95ba" remove "boinc_75e6ebc617cf95ba_net" 
Exit Code: 0
Output:
VBoxManage.exe: error: Bandwidth groups cannot be deleted while the VM is running

2021-06-13 02:30:12 (6908): 
Command: VBoxManage -q unregistervm "boinc_75e6ebc617cf95ba" --delete 
Exit Code: -2135228409
Output:
VBoxManage.exe: error: Cannot unregister the machine 'boinc_75e6ebc617cf95ba' while it is locked
VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component MachineWrap, interface IMachine, callee IUnknown
VBoxManage.exe: error: Context: "Unregister(CleanupMode_DetachAllReturnHardDisksOnly, ComSafeArrayAsOutParam(aMedia))" at line 154 of file VBoxManageMisc.cpp

2021-06-13 02:30:13 (6908): 
Command: VBoxManage -q unregistervm "boinc_75e6ebc617cf95ba" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

2021-06-13 02:30:14 (6908): 
Command: VBoxManage -q closemedium dvd "C:\ProgramData\BOINC\slots\2/vm_isocontext.iso" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

02:30:19 (6908): called boinc_finish(-2147467259)

</stderr_txt>
]]>


©2024 COPYRIGHT 2017-2018 NCN