Task 10529485

Name 08369510_17_1
Workunit 8167233
Created 13 Jun 2021, 15:01:32 UTC
Sent 13 Jun 2021, 15:03:57 UTC
Report deadline 18 Jun 2021, 15:03:57 UTC
Received 13 Jun 2021, 19:15:38 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status -2147467259 (0x80004005) Unknown error code
Computer ID 4935
Run time 14 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 2.96 GFLOPS
Application version boinc2docker v1.14 (vbox64_mt)
windows_x86_64
Peak working set size 11.48 MB
Peak swap size 6.22 MB
Peak disk usage 274.64 MB

Stderr output

<core_client_version>7.16.11</core_client_version>
<![CDATA[
<message>
Erreur non sp�cifi�e
 (0x80004005) - exit code 2147500037 (0x80004005)</message>
<stderr_txt>
2021-06-13 17:18:50 (8572): Detected: vboxwrapper 26202
2021-06-13 17:18:50 (8572): Detected: BOINC client v7.16.11
2021-06-13 17:18:52 (8572): Detected: VirtualBox VboxManage Interface (Version: 6.1.12)
2021-06-13 17:18:53 (8572): Create VM. (boinc_e081357bdb114af7, slot#3)
2021-06-13 17:18:53 (8572): Updating drive controller type and model for desired configuration.
2021-06-13 17:18:53 (8572): Setting Memory Size for VM. (3072MB)
2021-06-13 17:18:54 (8572): Setting CPU Count for VM. (1)
2021-06-13 17:18:54 (8572): Setting Chipset Options for VM.
2021-06-13 17:18:54 (8572): Setting Boot Options for VM.
2021-06-13 17:18:55 (8572): Setting Network Configuration for NAT.
2021-06-13 17:18:55 (8572): Enabling VM Network Access.
2021-06-13 17:18:55 (8572): Disabling USB Support for VM.
2021-06-13 17:18:56 (8572): Disabling COM Port Support for VM.
2021-06-13 17:18:56 (8572): Disabling LPT Port Support for VM.
2021-06-13 17:18:56 (8572): Disabling Audio Support for VM.
2021-06-13 17:18:57 (8572): Disabling Clipboard Support for VM.
2021-06-13 17:18:57 (8572): Disabling Drag and Drop Support for VM.
2021-06-13 17:18:57 (8572): Adding storage controller(s) to VM.
2021-06-13 17:18:58 (8572): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso)
2021-06-13 17:18:58 (8572): Adding VirtualBox Guest Additions to VM.
2021-06-13 17:18:59 (8572): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2021-06-13 17:18:59 (8572): Enabling shared directory for VM.
2021-06-13 17:18:59 (8572): Starting VM using VBoxManage interface. (boinc_e081357bdb114af7, slot#3)
2021-06-13 17:19:03 (8572): Error in start VM for VM: -2147467259
Command:
VBoxManage -q startvm "boinc_e081357bdb114af7" --type headless
Output:
Waiting for VM "boinc_e081357bdb114af7" to power on...
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole

2021-06-13 17:19:03 (8572): VM failed to start.
2021-06-13 17:19:03 (8572): Could not start 
2021-06-13 17:19:03 (8572): ERROR: VM failed to start
2021-06-13 17:19:03 (8572): Powering off VM.
2021-06-13 17:19:03 (8572): Deregistering VM. (boinc_e081357bdb114af7, slot#3)
2021-06-13 17:19:03 (8572): Removing network bandwidth throttle group from VM.
2021-06-13 17:19:04 (8572): Removing VM from VirtualBox.
2021-06-13 17:19:04 (8572): Removing virtual ISO 9660 disk from VirtualBox.

    Hypervisor System Log:

00:00:00.200845            C:\WINDOWS\system32\DRIVERS\VBoxNetAdp6.sys (Version: 6.1.12.39181)
00:00:00.207908          Loading settings file "C:\Users\margu\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:00.210623          usbLibGetDevices: Starting USB device enumeration
00:00:00.400192          usbLibGetDevices: Found 1 USB devices, 0 captured
00:00:00.914968          HostDnsMonitor: initializing
00:00:00.924473          HostDnsMonitor: updating information
00:00:00.924514          HostDnsMonitor: old information
00:00:00.924516            no server entries
00:00:00.924518            no domain set
00:00:00.924519            no search string entries
00:00:00.924521          HostDnsMonitor: new information
00:00:00.924522            server 1: 192.168.1.1
00:00:00.924524            domain: home
00:00:00.924526            no search string entries
00:00:01.039065          SUPR0QueryVTCaps -> VERR_VMX_MSR_ALL_VMX_DISABLED
00:00:01.040000          VD: VDInit finished with VINF_SUCCESS
00:00:01.041854          VirtualBox: object created
00:00:01.772478          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={Could not find a registered machine named 'boinc_e081357bdb114af7'}, preserve=false aResultDetail=0
00:00:02.065595          ERROR [COM]: aRC=VBOX_E_FILE_ERROR (0x80bb0004) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Could not find file for the medium 'C:\ProgramData\BOINC\slots\3\vm_image.vdi' (VERR_FILE_NOT_FOUND)}, preserve=false aResultDetail=-102
00:00:02.399875          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_e081357bdb114af7\boinc_e081357bdb114af7.vbox" with version "1.16-windows"
00:00:02.427118          Saving settings file "C:\Users\margu\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:02.744927          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_e081357bdb114af7\boinc_e081357bdb114af7.vbox" with version "1.16-windows"
00:00:03.061472          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_e081357bdb114af7\boinc_e081357bdb114af7.vbox" with version "1.16-windows"
00:00:03.385033          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_e081357bdb114af7\boinc_e081357bdb114af7.vbox" with version "1.16-windows"
00:00:03.723503          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_e081357bdb114af7\boinc_e081357bdb114af7.vbox" with version "1.16-windows"
00:00:04.083381          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_e081357bdb114af7\boinc_e081357bdb114af7.vbox" with version "1.16-windows"
00:00:04.409870          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_e081357bdb114af7\boinc_e081357bdb114af7.vbox" with version "1.16-windows"
00:00:04.751713          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_e081357bdb114af7\boinc_e081357bdb114af7.vbox" with version "1.16-windows"
00:00:05.078031          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_e081357bdb114af7\boinc_e081357bdb114af7.vbox" with version "1.16-windows"
00:00:05.394314          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_e081357bdb114af7\boinc_e081357bdb114af7.vbox" with version "1.16-windows"
00:00:05.764823          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_e081357bdb114af7\boinc_e081357bdb114af7.vbox" with version "1.16-windows"
00:00:06.099209          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_e081357bdb114af7\boinc_e081357bdb114af7.vbox" with version "1.16-windows"
00:00:06.443647          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_e081357bdb114af7\boinc_e081357bdb114af7.vbox" with version "1.16-windows"
00:00:06.787919          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_e081357bdb114af7\boinc_e081357bdb114af7.vbox" with version "1.16-windows"
00:00:07.114262          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_e081357bdb114af7\boinc_e081357bdb114af7.vbox" with version "1.16-windows"
00:00:07.449123          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.451780          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.452058          Saving settings file "C:\Users\margu\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:07.478531          Saving settings file "C:\Users\margu\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:07.493522          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_e081357bdb114af7\boinc_e081357bdb114af7.vbox" with version "1.16-windows"
00:00:07.836096          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.838371          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.838591          Saving settings file "C:\Users\margu\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:07.871521          Saving settings file "C:\Users\margu\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:07.892629          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_e081357bdb114af7\boinc_e081357bdb114af7.vbox" with version "1.16-windows"
00:00:08.163539          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_e081357bdb114af7\boinc_e081357bdb114af7.vbox" with version "1.16-windows"
00:00:08.484908          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_e081357bdb114af7\boinc_e081357bdb114af7.vbox" with version "1.16-windows"
00:00:08.863900          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.864122          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.874754          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:09.138690          Launched VM: 59637088 pid: 1908 (0x774) frontend: headless name: boinc_e081357bdb114af7
00:00:12.652583          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_e081357bdb114af7\boinc_e081357bdb114af7.vbox" with version "1.16-windows"
00:00:12.888904          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:13.390090          Saving settings file "C:\Users\margu\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:18.752442 main     VirtualBox: object deletion starts
00:00:18.753355 main     HostDnsMonitor: shutting down ...
00:00:18.753413 main     HostDnsMonitor: shut down
00:00:18.755390 Watcher  ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0
00:00:18.755644 main     VirtualBox: object deleted

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

Controllers:   1
Maximum ICH9 IDE Controllers:    1
Maximum IDE Port count:          2
Maximum Devices per IDE Port:    2
Maximum PIIX3 SATA Controllers:  1
Maximum ICH9 SATA Controllers:   8
Maximum SATA Port count:         30
Maximum Devices per SATA Port:   1
Maximum PIIX3 SCSI Controllers:  1
Maximum ICH9 SCSI Controllers:   8
Maximum SCSI Port count:         16
Maximum Devices per SCSI Port:   1
Maximum SAS PIIX3 Controllers:   1
Maximum SAS ICH9 Controllers:    8
Maximum SAS Port count:          255
Maximum Devices per SAS Port:    1
Maximum NVMe PIIX3 Controllers:  1
Maximum NVMe ICH9 Controllers:   8
Maximum NVMe Port count:         255
Maximum Devices per NVMe Port:   1
Maximum virtio-scsi PIIX3 Controllers:  1
Maximum virtio-scsi ICH9 Controllers:   8
Maximum virtio-scsi Port count:         256
Maximum Devices per virtio-scsi Port:   1
Maximum PIIX3 Floppy Controllers:1
Maximum ICH9 Floppy Controllers: 1
Maximum Floppy Port count:       1
Maximum Devices per Floppy Port: 2
Default machine folder:          C:\Users\margu\VirtualBox VMs
Raw-mode Supported:              no
Exclusive HW virtualization use: off
Default hard disk format:        VDI
VRDE auth library:               VBoxAuth
Webservice auth. library:        VBoxAuth
Remote desktop ExtPack:          
Log history count:               3
Default frontend:                
Default audio driver:            DirectSound
Autostart database path:         
Default Guest Additions ISO:     C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso
Logging Level:                   all
Proxy Mode:                      System
Proxy URL:                       

2021-06-13 17:18:52 (8572): 
Command: VBoxManage -q list hostinfo 
Exit Code: 0
Output:
Host Information:

Host time: 2021-06-13T15:18:52.335000000Z
Processor online count: 2
Processor count: 2
Processor online core count: 2
Processor core count: 2
Processor supports HW virtualization: no
Processor supports PAE: yes
Processor supports long mode: yes
Processor supports nested paging: no
Processor supports unrestricted guest: no
Processor supports nested HW virtualization: no
Processor#0 speed: unknown
Processor#0 description: Pentium(R) Dual-Core  CPU      E5300  @ 2.60GHz
Processor#1 speed: unknown
Processor#1 description: Pentium(R) Dual-Core  CPU      E5300  @ 2.60GHz
Memory size: 3963 MByte
Memory available: 1570 MByte
Operating system: Windows 10
Operating system version: 10.0.19043

2021-06-13 17:18:52 (8572): 
Command: VBoxManage -q showvminfo "boinc_e081357bdb114af7" --machinereadable 
Exit Code: -2135228415
Output:
VBoxManage.exe: error: Could not find a registered machine named 'boinc_e081357bdb114af7'
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown
VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2715 of file VBoxManageInfo.cpp

2021-06-13 17:18:53 (8572): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\3/vm_image.vdi" 
Exit Code: -2135228412
Output:
VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\3\vm_image.vdi' (VERR_FILE_NOT_FOUND)
VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp

2021-06-13 17:18:53 (8572): 
Command: VBoxManage -q createvm --name "boinc_e081357bdb114af7" --basefolder "C:\ProgramData\BOINC\slots\3" --ostype "Linux26_64" --register
Exit Code: 0
Output:
Virtual machine 'boinc_e081357bdb114af7' is created and registered.
UUID: de010243-dded-4960-a2c9-664b6eda2b27
Settings file: 'C:\ProgramData\BOINC\slots\3\boinc_e081357bdb114af7\boinc_e081357bdb114af7.vbox'

2021-06-13 17:18:53 (8572): 
Command: VBoxManage -q modifyvm "boinc_e081357bdb114af7" --description "08369510_17_1" 
Exit Code: 0
Output:

2021-06-13 17:18:54 (8572): 
Command: VBoxManage -q modifyvm "boinc_e081357bdb114af7" --memory 3072 
Exit Code: 0
Output:

2021-06-13 17:18:54 (8572): 
Command: VBoxManage -q modifyvm "boinc_e081357bdb114af7" --cpus 1 
Exit Code: 0
Output:

2021-06-13 17:18:54 (8572): 
Command: VBoxManage -q modifyvm "boinc_e081357bdb114af7" --acpi on --ioapic on 
Exit Code: 0
Output:

2021-06-13 17:18:55 (8572): 
Command: VBoxManage -q modifyvm "boinc_e081357bdb114af7" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2021-06-13 17:18:55 (8572): 
Command: VBoxManage -q modifyvm "boinc_e081357bdb114af7" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2021-06-13 17:18:55 (8572): 
Command: VBoxManage -q modifyvm "boinc_e081357bdb114af7" --cableconnected1 on 
Exit Code: 0
Output:

2021-06-13 17:18:56 (8572): 
Command: VBoxManage -q modifyvm "boinc_e081357bdb114af7" --usb off 
Exit Code: 0
Output:

2021-06-13 17:18:56 (8572): 
Command: VBoxManage -q modifyvm "boinc_e081357bdb114af7" --uart1 off --uart2 off 
Exit Code: 0
Output:

2021-06-13 17:18:56 (8572): 
Command: VBoxManage -q modifyvm "boinc_e081357bdb114af7" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2021-06-13 17:18:57 (8572): 
Command: VBoxManage -q modifyvm "boinc_e081357bdb114af7" --audio none 
Exit Code: 0
Output:

2021-06-13 17:18:57 (8572): 
Command: VBoxManage -q modifyvm "boinc_e081357bdb114af7" --clipboard disabled 
Exit Code: 0
Output:

2021-06-13 17:18:57 (8572): 
Command: VBoxManage -q modifyvm "boinc_e081357bdb114af7" --draganddrop disabled 
Exit Code: 0
Output:

2021-06-13 17:18:58 (8572): 
Command: VBoxManage -q storagectl "boinc_e081357bdb114af7" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2021-06-13 17:18:58 (8572): 
Command: VBoxManage -q storageattach "boinc_e081357bdb114af7" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\ProgramData\BOINC\slots\3/vm_isocontext.iso" 
Exit Code: 0
Output:

2021-06-13 17:18:58 (8572): 
Command: VBoxManage -q storageattach "boinc_e081357bdb114af7" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2021-06-13 17:18:59 (8572): 
Command: VBoxManage -q bandwidthctl "boinc_e081357bdb114af7" add "boinc_e081357bdb114af7_net" --type network --limit 1024G 
Exit Code: 0
Output:

2021-06-13 17:18:59 (8572): 
Command: VBoxManage -q sharedfolder add "boinc_e081357bdb114af7" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\3/shared"
Exit Code: 0
Output:

2021-06-13 17:19:03 (8572): 
Command: VBoxManage -q startvm "boinc_e081357bdb114af7" --type headless
Exit Code: -2147467259
Output:
Waiting for VM "boinc_e081357bdb114af7" to power on...
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole

2021-06-13 17:19:03 (8572): 
Command: VBoxManage -q snapshot "boinc_e081357bdb114af7" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2021-06-13 17:19:04 (8572): 
Command: VBoxManage -q bandwidthctl "boinc_e081357bdb114af7" remove "boinc_e081357bdb114af7_net" 
Exit Code: 0
Output:
VBoxManage.exe: error: Bandwidth groups cannot be deleted while the VM is running

2021-06-13 17:19:04 (8572): 
Command: VBoxManage -q unregistervm "boinc_e081357bdb114af7" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

2021-06-13 17:19:04 (8572): 
Command: VBoxManage -q closemedium dvd "C:\ProgramData\BOINC\slots\3/vm_isocontext.iso" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

17:19:10 (8572): called boinc_finish(-2147467259)

</stderr_txt>
]]>


©2025 COPYRIGHT 2017-2018 NCN