Task 10550868

Name 08373036_35_0
Workunit 8249490
Created 13 Jun 2021, 23:06:42 UTC
Sent 14 Jun 2021, 3:54:53 UTC
Report deadline 19 Jun 2021, 3:54:53 UTC
Received 14 Jun 2021, 5:41:04 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status -2147467259 (0x80004005) Unknown error code
Computer ID 10985
Run time 21 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 2.89 GFLOPS
Application version boinc2docker v1.14 (vbox64_mt)
windows_x86_64
Peak working set size 10.89 MB
Peak swap size 6.22 MB
Peak disk usage 498.85 MB

Stderr output

<core_client_version>7.16.11</core_client_version>
<![CDATA[
<message>
Unbekannter Fehler
 (0x80004005) - exit code 2147500037 (0x80004005)</message>
<stderr_txt>
2021-06-14 05:59:56 (8568): Detected: vboxwrapper 26202
2021-06-14 05:59:56 (8568): Detected: BOINC client v7.16.11
2021-06-14 05:59:58 (8568): Detected: VirtualBox VboxManage Interface (Version: 6.1.14)
2021-06-14 05:59:58 (8568): Create VM. (boinc_6c51647164a030ec, slot#0)
2021-06-14 05:59:58 (8568): Updating drive controller type and model for desired configuration.
2021-06-14 05:59:59 (8568): Setting Memory Size for VM. (3072MB)
2021-06-14 05:59:59 (8568): Setting CPU Count for VM. (1)
2021-06-14 05:59:59 (8568): Setting Chipset Options for VM.
2021-06-14 06:00:00 (8568): Setting Boot Options for VM.
2021-06-14 06:00:00 (8568): Setting Network Configuration for NAT.
2021-06-14 06:00:00 (8568): Enabling VM Network Access.
2021-06-14 06:00:01 (8568): Disabling USB Support for VM.
2021-06-14 06:00:01 (8568): Disabling COM Port Support for VM.
2021-06-14 06:00:01 (8568): Disabling LPT Port Support for VM.
2021-06-14 06:00:01 (8568): Disabling Audio Support for VM.
2021-06-14 06:00:02 (8568): Disabling Clipboard Support for VM.
2021-06-14 06:00:02 (8568): Disabling Drag and Drop Support for VM.
2021-06-14 06:00:02 (8568): Adding storage controller(s) to VM.
2021-06-14 06:00:02 (8568): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso)
2021-06-14 06:00:03 (8568): Adding VirtualBox Guest Additions to VM.
2021-06-14 06:00:03 (8568): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2021-06-14 06:00:03 (8568): Enabling shared directory for VM.
2021-06-14 06:00:04 (8568): Starting VM using VBoxManage interface. (boinc_6c51647164a030ec, slot#0)
2021-06-14 06:00:08 (8568): Error in start VM for VM: -2147467259
Command:
VBoxManage -q startvm "boinc_6c51647164a030ec" --type headless
Output:
Waiting for VM "boinc_6c51647164a030ec" to power on...
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: AMD-V is disabled in the BIOS (or by the host OS) (VERR_SVM_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole

2021-06-14 06:00:08 (8568): VM failed to start.
2021-06-14 06:00:08 (8568): Could not start 
2021-06-14 06:00:08 (8568): ERROR: VM failed to start
2021-06-14 06:00:08 (8568): Powering off VM.
2021-06-14 06:00:08 (8568): Deregistering VM. (boinc_6c51647164a030ec, slot#0)
2021-06-14 06:00:08 (8568): Removing network bandwidth throttle group from VM.
2021-06-14 06:00:08 (8568): Removing VM from VirtualBox.
2021-06-14 06:00:09 (8568): Removing virtual ISO 9660 disk from VirtualBox.

    Hypervisor System Log:

00:00:05.661674          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:05.667312          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:05.667621          Saving settings file "C:\Users\Admin\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:05.674695          Saving settings file "C:\Users\Admin\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:05.681983          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_6c51647164a030ec\boinc_6c51647164a030ec.vbox" with version "1.16-windows"
00:00:05.797454          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_8698aa4e9f54cec3\boinc_8698aa4e9f54cec3.vbox" with version "1.16-windows"
00:00:05.950728          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:05.953527          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:05.953862          Saving settings file "C:\Users\Admin\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:05.961066          Saving settings file "C:\Users\Admin\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:05.968835          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_6c51647164a030ec\boinc_6c51647164a030ec.vbox" with version "1.16-windows"
00:00:06.073704          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_8698aa4e9f54cec3\boinc_8698aa4e9f54cec3.vbox" with version "1.16-windows"
00:00:06.221691          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_6c51647164a030ec\boinc_6c51647164a030ec.vbox" with version "1.16-windows"
00:00:06.340592          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.345708          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.346060          Saving settings file "C:\Users\Admin\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:06.354257          Saving settings file "C:\Users\Admin\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:06.361651          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_8698aa4e9f54cec3\boinc_8698aa4e9f54cec3.vbox" with version "1.16-windows"
00:00:06.491268          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_6c51647164a030ec\boinc_6c51647164a030ec.vbox" with version "1.16-windows"
00:00:06.618100          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.618934          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.620139          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_8698aa4e9f54cec3\boinc_8698aa4e9f54cec3.vbox" with version "1.16-windows"
00:00:06.787805          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.788075          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.805406          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:06.896433          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_8698aa4e9f54cec3\boinc_8698aa4e9f54cec3.vbox" with version "1.16-windows"
00:00:07.049037          Launched VM: 77760624 pid: 13908 (0x3654) frontend: headless name: boinc_6c51647164a030ec
00:00:07.250171          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_8698aa4e9f54cec3\boinc_8698aa4e9f54cec3.vbox" with version "1.16-windows"
00:00:07.536259          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.536538          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.552116          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:07.776666          Launched VM: 77716992 pid: 10936 (0x2ab8) frontend: headless name: boinc_8698aa4e9f54cec3
00:00:10.918699          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_6c51647164a030ec\boinc_6c51647164a030ec.vbox" with version "1.16-windows"
00:00:11.078973          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:11.211512          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_6c51647164a030ec\boinc_6c51647164a030ec.vbox" with version "1.16-windows"
00:00:11.476248          Saving settings file "C:\Users\Admin\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:11.772564          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_8698aa4e9f54cec3\boinc_8698aa4e9f54cec3.vbox" with version "1.16-windows"
00:00:11.933439          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:12.077097          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_8698aa4e9f54cec3\boinc_8698aa4e9f54cec3.vbox" with version "1.16-windows"
00:00:12.322823          Saving settings file "C:\Users\Admin\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:17.609405 main     VirtualBox: object deletion starts
00:00:17.611227 main     HostDnsMonitor: shutting down ...
00:00:17.611433 main     HostDnsMonitor: shut down
00:00:17.614692 Watcher  ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0
00:00:17.615054 main     VirtualBox: object deleted

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

imum Devices per SATA Port:   1
Maximum PIIX3 SCSI Controllers:  1
Maximum ICH9 SCSI Controllers:   8
Maximum SCSI Port count:         16
Maximum Devices per SCSI Port:   1
Maximum SAS PIIX3 Controllers:   1
Maximum SAS ICH9 Controllers:    8
Maximum SAS Port count:          255
Maximum Devices per SAS Port:    1
Maximum NVMe PIIX3 Controllers:  1
Maximum NVMe ICH9 Controllers:   8
Maximum NVMe Port count:         255
Maximum Devices per NVMe Port:   1
Maximum virtio-scsi PIIX3 Controllers:  1
Maximum virtio-scsi ICH9 Controllers:   8
Maximum virtio-scsi Port count:         256
Maximum Devices per virtio-scsi Port:   1
Maximum PIIX3 Floppy Controllers:1
Maximum ICH9 Floppy Controllers: 1
Maximum Floppy Port count:       1
Maximum Devices per Floppy Port: 2
Default machine folder:          C:\Users\Admin\VirtualBox VMs
Raw-mode Supported:              no
Exclusive HW virtualization use: off
Default hard disk format:        VDI
VRDE auth library:               VBoxAuth
Webservice auth. library:        VBoxAuth
Remote desktop ExtPack:          
Log history count:               3
Default frontend:                
Default audio driver:            DirectSound
Autostart database path:         
Default Guest Additions ISO:     C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso
Logging Level:                   all
Proxy Mode:                      System
Proxy URL:                       

2021-06-14 05:59:58 (8568): 
Command: VBoxManage -q list hostinfo 
Exit Code: 0
Output:
Host Information:

Host time: 2021-06-14T03:59:58.107000000Z
Processor online count: 6
Processor count: 6
Processor online core count: 3
Processor core count: 3
Processor supports HW virtualization: no
Processor supports PAE: yes
Processor supports long mode: yes
Processor supports nested paging: no
Processor supports unrestricted guest: no
Processor supports nested HW virtualization: no
Processor#0 speed: unknown
Processor#0 description: AMD FX(tm)-6300 Six-Core Processor
Processor#1 speed: unknown
Processor#1 description: AMD FX(tm)-6300 Six-Core Processor
Processor#2 speed: unknown
Processor#2 description: AMD FX(tm)-6300 Six-Core Processor
Processor#3 speed: unknown
Processor#3 description: AMD FX(tm)-6300 Six-Core Processor
Processor#4 speed: unknown
Processor#4 description: AMD FX(tm)-6300 Six-Core Processor
Processor#5 speed: unknown
Processor#5 description: AMD FX(tm)-6300 Six-Core Processor
Memory size: 7661 MByte
Memory available: 2443 MByte
Operating system: Windows 10
Operating system version: 10.0.19042

2021-06-14 05:59:58 (8568): 
Command: VBoxManage -q showvminfo "boinc_6c51647164a030ec" --machinereadable 
Exit Code: -2135228415
Output:
VBoxManage.exe: error: Could not find a registered machine named 'boinc_6c51647164a030ec'
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown
VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2715 of file VBoxManageInfo.cpp

2021-06-14 05:59:58 (8568): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\0/vm_image.vdi" 
Exit Code: -2135228412
Output:
VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\0\vm_image.vdi' (VERR_FILE_NOT_FOUND)
VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp

2021-06-14 05:59:59 (8568): 
Command: VBoxManage -q createvm --name "boinc_6c51647164a030ec" --basefolder "C:\ProgramData\BOINC\slots\0" --ostype "Linux26_64" --register
Exit Code: 0
Output:
Virtual machine 'boinc_6c51647164a030ec' is created and registered.
UUID: 27fd8b5e-96f5-476e-934b-fa033cc0f6ea
Settings file: 'C:\ProgramData\BOINC\slots\0\boinc_6c51647164a030ec\boinc_6c51647164a030ec.vbox'

2021-06-14 05:59:59 (8568): 
Command: VBoxManage -q modifyvm "boinc_6c51647164a030ec" --description "08373036_35_0" 
Exit Code: 0
Output:

2021-06-14 05:59:59 (8568): 
Command: VBoxManage -q modifyvm "boinc_6c51647164a030ec" --memory 3072 
Exit Code: 0
Output:

2021-06-14 05:59:59 (8568): 
Command: VBoxManage -q modifyvm "boinc_6c51647164a030ec" --cpus 1 
Exit Code: 0
Output:

2021-06-14 06:00:00 (8568): 
Command: VBoxManage -q modifyvm "boinc_6c51647164a030ec" --acpi on --ioapic on 
Exit Code: 0
Output:

2021-06-14 06:00:00 (8568): 
Command: VBoxManage -q modifyvm "boinc_6c51647164a030ec" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2021-06-14 06:00:00 (8568): 
Command: VBoxManage -q modifyvm "boinc_6c51647164a030ec" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2021-06-14 06:00:01 (8568): 
Command: VBoxManage -q modifyvm "boinc_6c51647164a030ec" --cableconnected1 on 
Exit Code: 0
Output:

2021-06-14 06:00:01 (8568): 
Command: VBoxManage -q modifyvm "boinc_6c51647164a030ec" --usb off 
Exit Code: 0
Output:

2021-06-14 06:00:01 (8568): 
Command: VBoxManage -q modifyvm "boinc_6c51647164a030ec" --uart1 off --uart2 off 
Exit Code: 0
Output:

2021-06-14 06:00:01 (8568): 
Command: VBoxManage -q modifyvm "boinc_6c51647164a030ec" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2021-06-14 06:00:02 (8568): 
Command: VBoxManage -q modifyvm "boinc_6c51647164a030ec" --audio none 
Exit Code: 0
Output:

2021-06-14 06:00:02 (8568): 
Command: VBoxManage -q modifyvm "boinc_6c51647164a030ec" --clipboard disabled 
Exit Code: 0
Output:

2021-06-14 06:00:02 (8568): 
Command: VBoxManage -q modifyvm "boinc_6c51647164a030ec" --draganddrop disabled 
Exit Code: 0
Output:

2021-06-14 06:00:02 (8568): 
Command: VBoxManage -q storagectl "boinc_6c51647164a030ec" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2021-06-14 06:00:03 (8568): 
Command: VBoxManage -q storageattach "boinc_6c51647164a030ec" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\ProgramData\BOINC\slots\0/vm_isocontext.iso" 
Exit Code: 0
Output:

2021-06-14 06:00:03 (8568): 
Command: VBoxManage -q storageattach "boinc_6c51647164a030ec" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2021-06-14 06:00:03 (8568): 
Command: VBoxManage -q bandwidthctl "boinc_6c51647164a030ec" add "boinc_6c51647164a030ec_net" --type network --limit 1024G 
Exit Code: 0
Output:

2021-06-14 06:00:04 (8568): 
Command: VBoxManage -q sharedfolder add "boinc_6c51647164a030ec" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\0/shared"
Exit Code: 0
Output:

2021-06-14 06:00:08 (8568): 
Command: VBoxManage -q startvm "boinc_6c51647164a030ec" --type headless
Exit Code: -2147467259
Output:
Waiting for VM "boinc_6c51647164a030ec" to power on...
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: AMD-V is disabled in the BIOS (or by the host OS) (VERR_SVM_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole

2021-06-14 06:00:08 (8568): 
Command: VBoxManage -q snapshot "boinc_6c51647164a030ec" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2021-06-14 06:00:08 (8568): 
Command: VBoxManage -q bandwidthctl "boinc_6c51647164a030ec" remove "boinc_6c51647164a030ec_net" 
Exit Code: 0
Output:

2021-06-14 06:00:09 (8568): 
Command: VBoxManage -q unregistervm "boinc_6c51647164a030ec" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

2021-06-14 06:00:09 (8568): 
Command: VBoxManage -q closemedium dvd "C:\ProgramData\BOINC\slots\0/vm_isocontext.iso" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

06:00:15 (8568): called boinc_finish(-2147467259)

</stderr_txt>
]]>


©2024 COPYRIGHT 2017-2018 NCN