Task 10550886

Name 08373039_17_0
Workunit 8249508
Created 13 Jun 2021, 23:07:12 UTC
Sent 14 Jun 2021, 3:55:06 UTC
Report deadline 19 Jun 2021, 3:55:06 UTC
Received 14 Jun 2021, 5:41:04 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status -2147467259 (0x80004005) Unknown error code
Computer ID 10985
Run time 21 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 2.89 GFLOPS
Application version boinc2docker v1.14 (vbox64_mt)
windows_x86_64
Peak working set size 10.89 MB
Peak swap size 6.22 MB
Peak disk usage 499.52 MB

Stderr output

<core_client_version>7.16.11</core_client_version>
<![CDATA[
<message>
Unbekannter Fehler
 (0x80004005) - exit code 2147500037 (0x80004005)</message>
<stderr_txt>
2021-06-14 06:01:34 (19084): Detected: vboxwrapper 26202
2021-06-14 06:01:34 (19084): Detected: BOINC client v7.16.11
2021-06-14 06:01:36 (19084): Detected: VirtualBox VboxManage Interface (Version: 6.1.14)
2021-06-14 06:01:37 (19084): Create VM. (boinc_187ff14a542d71df, slot#0)
2021-06-14 06:01:37 (19084): Updating drive controller type and model for desired configuration.
2021-06-14 06:01:37 (19084): Setting Memory Size for VM. (3072MB)
2021-06-14 06:01:37 (19084): Setting CPU Count for VM. (1)
2021-06-14 06:01:38 (19084): Setting Chipset Options for VM.
2021-06-14 06:01:38 (19084): Setting Boot Options for VM.
2021-06-14 06:01:38 (19084): Setting Network Configuration for NAT.
2021-06-14 06:01:39 (19084): Enabling VM Network Access.
2021-06-14 06:01:39 (19084): Disabling USB Support for VM.
2021-06-14 06:01:39 (19084): Disabling COM Port Support for VM.
2021-06-14 06:01:39 (19084): Disabling LPT Port Support for VM.
2021-06-14 06:01:40 (19084): Disabling Audio Support for VM.
2021-06-14 06:01:40 (19084): Disabling Clipboard Support for VM.
2021-06-14 06:01:40 (19084): Disabling Drag and Drop Support for VM.
2021-06-14 06:01:41 (19084): Adding storage controller(s) to VM.
2021-06-14 06:01:41 (19084): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso)
2021-06-14 06:01:41 (19084): Adding VirtualBox Guest Additions to VM.
2021-06-14 06:01:41 (19084): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2021-06-14 06:01:42 (19084): Enabling shared directory for VM.
2021-06-14 06:01:42 (19084): Starting VM using VBoxManage interface. (boinc_187ff14a542d71df, slot#0)
2021-06-14 06:01:46 (19084): Error in start VM for VM: -2147467259
Command:
VBoxManage -q startvm "boinc_187ff14a542d71df" --type headless
Output:
Waiting for VM "boinc_187ff14a542d71df" to power on...
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: AMD-V is disabled in the BIOS (or by the host OS) (VERR_SVM_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole

2021-06-14 06:01:46 (19084): VM failed to start.
2021-06-14 06:01:46 (19084): Could not start 
2021-06-14 06:01:46 (19084): ERROR: VM failed to start
2021-06-14 06:01:46 (19084): Powering off VM.
2021-06-14 06:01:46 (19084): Deregistering VM. (boinc_187ff14a542d71df, slot#0)
2021-06-14 06:01:47 (19084): Removing network bandwidth throttle group from VM.
2021-06-14 06:01:47 (19084): Removing VM from VirtualBox.
2021-06-14 06:01:47 (19084): Removing virtual ISO 9660 disk from VirtualBox.

    Hypervisor System Log:

00:00:05.746863          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_187ff14a542d71df\boinc_187ff14a542d71df.vbox" with version "1.16-windows"
00:00:05.889215          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_19fc7e9543375c68\boinc_19fc7e9543375c68.vbox" with version "1.16-windows"
00:00:06.023705          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.026611          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.026917          Saving settings file "C:\Users\Admin\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:06.036615          Saving settings file "C:\Users\Admin\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:06.045331          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_187ff14a542d71df\boinc_187ff14a542d71df.vbox" with version "1.16-windows"
00:00:06.165536          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.168601          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.168876          Saving settings file "C:\Users\Admin\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:06.178845          Saving settings file "C:\Users\Admin\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:06.187380          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_19fc7e9543375c68\boinc_19fc7e9543375c68.vbox" with version "1.16-windows"
00:00:06.324123          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.326596          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.326901          Saving settings file "C:\Users\Admin\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:06.336583          Saving settings file "C:\Users\Admin\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:06.346412          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_187ff14a542d71df\boinc_187ff14a542d71df.vbox" with version "1.16-windows"
00:00:06.453504          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.454305          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.455345          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_19fc7e9543375c68\boinc_19fc7e9543375c68.vbox" with version "1.16-windows"
00:00:06.591463          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_187ff14a542d71df\boinc_187ff14a542d71df.vbox" with version "1.16-windows"
00:00:06.734100          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_19fc7e9543375c68\boinc_19fc7e9543375c68.vbox" with version "1.16-windows"
00:00:06.876472          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_187ff14a542d71df\boinc_187ff14a542d71df.vbox" with version "1.16-windows"
00:00:07.003148          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_19fc7e9543375c68\boinc_19fc7e9543375c68.vbox" with version "1.16-windows"
00:00:07.169858          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.170241          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.188711          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:07.293354          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.293639          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.310622          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:07.460221          Launched VM: 83443360 pid: 20248 (0x4f18) frontend: headless name: boinc_187ff14a542d71df
00:00:07.609897          Launched VM: 83341904 pid: 10740 (0x29f4) frontend: headless name: boinc_19fc7e9543375c68
00:00:11.466997          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_187ff14a542d71df\boinc_187ff14a542d71df.vbox" with version "1.16-windows"
00:00:11.612167          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_19fc7e9543375c68\boinc_19fc7e9543375c68.vbox" with version "1.16-windows"
00:00:11.657183          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:11.785495          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:11.786510          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_187ff14a542d71df\boinc_187ff14a542d71df.vbox" with version "1.16-windows"
00:00:11.916923          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_19fc7e9543375c68\boinc_19fc7e9543375c68.vbox" with version "1.16-windows"
00:00:12.068570          Saving settings file "C:\Users\Admin\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:12.180089          Saving settings file "C:\Users\Admin\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:17.474025 main     VirtualBox: object deletion starts
00:00:17.476031 main     HostDnsMonitor: shutting down ...
00:00:17.476110 main     HostDnsMonitor: shut down
00:00:17.480352 Watcher  ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0
00:00:17.480630 main     VirtualBox: object deleted

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

   1
Maximum PIIX3 SCSI Controllers:  1
Maximum ICH9 SCSI Controllers:   8
Maximum SCSI Port count:         16
Maximum Devices per SCSI Port:   1
Maximum SAS PIIX3 Controllers:   1
Maximum SAS ICH9 Controllers:    8
Maximum SAS Port count:          255
Maximum Devices per SAS Port:    1
Maximum NVMe PIIX3 Controllers:  1
Maximum NVMe ICH9 Controllers:   8
Maximum NVMe Port count:         255
Maximum Devices per NVMe Port:   1
Maximum virtio-scsi PIIX3 Controllers:  1
Maximum virtio-scsi ICH9 Controllers:   8
Maximum virtio-scsi Port count:         256
Maximum Devices per virtio-scsi Port:   1
Maximum PIIX3 Floppy Controllers:1
Maximum ICH9 Floppy Controllers: 1
Maximum Floppy Port count:       1
Maximum Devices per Floppy Port: 2
Default machine folder:          C:\Users\Admin\VirtualBox VMs
Raw-mode Supported:              no
Exclusive HW virtualization use: off
Default hard disk format:        VDI
VRDE auth library:               VBoxAuth
Webservice auth. library:        VBoxAuth
Remote desktop ExtPack:          
Log history count:               3
Default frontend:                
Default audio driver:            DirectSound
Autostart database path:         
Default Guest Additions ISO:     C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso
Logging Level:                   all
Proxy Mode:                      System
Proxy URL:                       

2021-06-14 06:01:36 (19084): 
Command: VBoxManage -q list hostinfo 
Exit Code: 0
Output:
Host Information:

Host time: 2021-06-14T04:01:36.392000000Z
Processor online count: 6
Processor count: 6
Processor online core count: 3
Processor core count: 3
Processor supports HW virtualization: no
Processor supports PAE: yes
Processor supports long mode: yes
Processor supports nested paging: no
Processor supports unrestricted guest: no
Processor supports nested HW virtualization: no
Processor#0 speed: unknown
Processor#0 description: AMD FX(tm)-6300 Six-Core Processor
Processor#1 speed: unknown
Processor#1 description: AMD FX(tm)-6300 Six-Core Processor
Processor#2 speed: unknown
Processor#2 description: AMD FX(tm)-6300 Six-Core Processor
Processor#3 speed: unknown
Processor#3 description: AMD FX(tm)-6300 Six-Core Processor
Processor#4 speed: unknown
Processor#4 description: AMD FX(tm)-6300 Six-Core Processor
Processor#5 speed: unknown
Processor#5 description: AMD FX(tm)-6300 Six-Core Processor
Memory size: 7661 MByte
Memory available: 2628 MByte
Operating system: Windows 10
Operating system version: 10.0.19042

2021-06-14 06:01:36 (19084): 
Command: VBoxManage -q showvminfo "boinc_187ff14a542d71df" --machinereadable 
Exit Code: -2135228415
Output:
VBoxManage.exe: error: Could not find a registered machine named 'boinc_187ff14a542d71df'
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown
VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2715 of file VBoxManageInfo.cpp

2021-06-14 06:01:37 (19084): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\0/vm_image.vdi" 
Exit Code: -2135228412
Output:
VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\0\vm_image.vdi' (VERR_FILE_NOT_FOUND)
VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp

2021-06-14 06:01:37 (19084): 
Command: VBoxManage -q createvm --name "boinc_187ff14a542d71df" --basefolder "C:\ProgramData\BOINC\slots\0" --ostype "Linux26_64" --register
Exit Code: 0
Output:
Virtual machine 'boinc_187ff14a542d71df' is created and registered.
UUID: 365b474a-6c9e-4f69-b992-798320a3bf31
Settings file: 'C:\ProgramData\BOINC\slots\0\boinc_187ff14a542d71df\boinc_187ff14a542d71df.vbox'

2021-06-14 06:01:37 (19084): 
Command: VBoxManage -q modifyvm "boinc_187ff14a542d71df" --description "08373039_17_0" 
Exit Code: 0
Output:

2021-06-14 06:01:37 (19084): 
Command: VBoxManage -q modifyvm "boinc_187ff14a542d71df" --memory 3072 
Exit Code: 0
Output:

2021-06-14 06:01:38 (19084): 
Command: VBoxManage -q modifyvm "boinc_187ff14a542d71df" --cpus 1 
Exit Code: 0
Output:

2021-06-14 06:01:38 (19084): 
Command: VBoxManage -q modifyvm "boinc_187ff14a542d71df" --acpi on --ioapic on 
Exit Code: 0
Output:

2021-06-14 06:01:38 (19084): 
Command: VBoxManage -q modifyvm "boinc_187ff14a542d71df" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2021-06-14 06:01:39 (19084): 
Command: VBoxManage -q modifyvm "boinc_187ff14a542d71df" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2021-06-14 06:01:39 (19084): 
Command: VBoxManage -q modifyvm "boinc_187ff14a542d71df" --cableconnected1 on 
Exit Code: 0
Output:

2021-06-14 06:01:39 (19084): 
Command: VBoxManage -q modifyvm "boinc_187ff14a542d71df" --usb off 
Exit Code: 0
Output:

2021-06-14 06:01:39 (19084): 
Command: VBoxManage -q modifyvm "boinc_187ff14a542d71df" --uart1 off --uart2 off 
Exit Code: 0
Output:

2021-06-14 06:01:40 (19084): 
Command: VBoxManage -q modifyvm "boinc_187ff14a542d71df" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2021-06-14 06:01:40 (19084): 
Command: VBoxManage -q modifyvm "boinc_187ff14a542d71df" --audio none 
Exit Code: 0
Output:

2021-06-14 06:01:40 (19084): 
Command: VBoxManage -q modifyvm "boinc_187ff14a542d71df" --clipboard disabled 
Exit Code: 0
Output:

2021-06-14 06:01:41 (19084): 
Command: VBoxManage -q modifyvm "boinc_187ff14a542d71df" --draganddrop disabled 
Exit Code: 0
Output:

2021-06-14 06:01:41 (19084): 
Command: VBoxManage -q storagectl "boinc_187ff14a542d71df" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2021-06-14 06:01:41 (19084): 
Command: VBoxManage -q storageattach "boinc_187ff14a542d71df" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\ProgramData\BOINC\slots\0/vm_isocontext.iso" 
Exit Code: 0
Output:

2021-06-14 06:01:41 (19084): 
Command: VBoxManage -q storageattach "boinc_187ff14a542d71df" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2021-06-14 06:01:42 (19084): 
Command: VBoxManage -q bandwidthctl "boinc_187ff14a542d71df" add "boinc_187ff14a542d71df_net" --type network --limit 1024G 
Exit Code: 0
Output:

2021-06-14 06:01:42 (19084): 
Command: VBoxManage -q sharedfolder add "boinc_187ff14a542d71df" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\0/shared"
Exit Code: 0
Output:

2021-06-14 06:01:46 (19084): 
Command: VBoxManage -q startvm "boinc_187ff14a542d71df" --type headless
Exit Code: -2147467259
Output:
Waiting for VM "boinc_187ff14a542d71df" to power on...
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: AMD-V is disabled in the BIOS (or by the host OS) (VERR_SVM_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole

2021-06-14 06:01:47 (19084): 
Command: VBoxManage -q snapshot "boinc_187ff14a542d71df" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2021-06-14 06:01:47 (19084): 
Command: VBoxManage -q bandwidthctl "boinc_187ff14a542d71df" remove "boinc_187ff14a542d71df_net" 
Exit Code: 0
Output:

2021-06-14 06:01:47 (19084): 
Command: VBoxManage -q unregistervm "boinc_187ff14a542d71df" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

2021-06-14 06:01:47 (19084): 
Command: VBoxManage -q closemedium dvd "C:\ProgramData\BOINC\slots\0/vm_isocontext.iso" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

06:01:53 (19084): called boinc_finish(-2147467259)

</stderr_txt>
]]>