Task 10550897

Name 08373039_28_0
Workunit 8249519
Created 13 Jun 2021, 23:07:12 UTC
Sent 14 Jun 2021, 3:55:06 UTC
Report deadline 19 Jun 2021, 3:55:06 UTC
Received 14 Jun 2021, 5:41:04 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status -2147467259 (0x80004005) Unknown error code
Computer ID 10985
Run time 20 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 2.89 GFLOPS
Application version boinc2docker v1.14 (vbox64_mt)
windows_x86_64
Peak working set size 10.89 MB
Peak swap size 6.22 MB
Peak disk usage 499.52 MB

Stderr output

<core_client_version>7.16.11</core_client_version>
<![CDATA[
<message>
Unbekannter Fehler
 (0x80004005) - exit code 2147500037 (0x80004005)</message>
<stderr_txt>
2021-06-14 06:02:50 (8552): Detected: vboxwrapper 26202
2021-06-14 06:02:50 (8552): Detected: BOINC client v7.16.11
2021-06-14 06:02:50 (8552): Detected: VirtualBox VboxManage Interface (Version: 6.1.14)
2021-06-14 06:02:51 (8552): Create VM. (boinc_871bdfeaab3fd787, slot#1)
2021-06-14 06:02:51 (8552): Updating drive controller type and model for desired configuration.
2021-06-14 06:02:52 (8552): Setting Memory Size for VM. (3072MB)
2021-06-14 06:02:52 (8552): Setting CPU Count for VM. (1)
2021-06-14 06:02:52 (8552): Setting Chipset Options for VM.
2021-06-14 06:02:53 (8552): Setting Boot Options for VM.
2021-06-14 06:02:53 (8552): Setting Network Configuration for NAT.
2021-06-14 06:02:53 (8552): Enabling VM Network Access.
2021-06-14 06:02:54 (8552): Disabling USB Support for VM.
2021-06-14 06:02:54 (8552): Disabling COM Port Support for VM.
2021-06-14 06:02:54 (8552): Disabling LPT Port Support for VM.
2021-06-14 06:02:54 (8552): Disabling Audio Support for VM.
2021-06-14 06:02:55 (8552): Disabling Clipboard Support for VM.
2021-06-14 06:02:55 (8552): Disabling Drag and Drop Support for VM.
2021-06-14 06:02:55 (8552): Adding storage controller(s) to VM.
2021-06-14 06:02:55 (8552): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso)
2021-06-14 06:02:56 (8552): Adding VirtualBox Guest Additions to VM.
2021-06-14 06:02:56 (8552): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2021-06-14 06:02:56 (8552): Enabling shared directory for VM.
2021-06-14 06:02:57 (8552): Starting VM using VBoxManage interface. (boinc_871bdfeaab3fd787, slot#1)
2021-06-14 06:03:01 (8552): Error in start VM for VM: -2147467259
Command:
VBoxManage -q startvm "boinc_871bdfeaab3fd787" --type headless
Output:
Waiting for VM "boinc_871bdfeaab3fd787" to power on...
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: AMD-V is disabled in the BIOS (or by the host OS) (VERR_SVM_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole

2021-06-14 06:03:01 (8552): VM failed to start.
2021-06-14 06:03:01 (8552): Could not start 
2021-06-14 06:03:01 (8552): ERROR: VM failed to start
2021-06-14 06:03:01 (8552): Powering off VM.
2021-06-14 06:03:01 (8552): Deregistering VM. (boinc_871bdfeaab3fd787, slot#1)
2021-06-14 06:03:01 (8552): Removing network bandwidth throttle group from VM.
2021-06-14 06:03:02 (8552): Removing VM from VirtualBox.
2021-06-14 06:03:02 (8552): Removing virtual ISO 9660 disk from VirtualBox.

    Hypervisor System Log:

00:00:05.742357          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_74930aab2117c5a7\boinc_74930aab2117c5a7.vbox" with version "1.16-windows"
00:00:05.942978          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_871bdfeaab3fd787\boinc_871bdfeaab3fd787.vbox" with version "1.16-windows"
00:00:06.028997          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.032048          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.032364          Saving settings file "C:\Users\Admin\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:06.040539          Saving settings file "C:\Users\Admin\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:06.047816          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_74930aab2117c5a7\boinc_74930aab2117c5a7.vbox" with version "1.16-windows"
00:00:06.222698          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_871bdfeaab3fd787\boinc_871bdfeaab3fd787.vbox" with version "1.16-windows"
00:00:06.306745          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.309374          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.309687          Saving settings file "C:\Users\Admin\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:06.317917          Saving settings file "C:\Users\Admin\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:06.325208          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_74930aab2117c5a7\boinc_74930aab2117c5a7.vbox" with version "1.16-windows"
00:00:06.509031          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.512305          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.512695          Saving settings file "C:\Users\Admin\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:06.521350          Saving settings file "C:\Users\Admin\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:06.530346          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_871bdfeaab3fd787\boinc_871bdfeaab3fd787.vbox" with version "1.16-windows"
00:00:06.592186          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_74930aab2117c5a7\boinc_74930aab2117c5a7.vbox" with version "1.16-windows"
00:00:06.799592          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.800633          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.802024          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_871bdfeaab3fd787\boinc_871bdfeaab3fd787.vbox" with version "1.16-windows"
00:00:06.866624          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_74930aab2117c5a7\boinc_74930aab2117c5a7.vbox" with version "1.16-windows"
00:00:07.075602          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_871bdfeaab3fd787\boinc_871bdfeaab3fd787.vbox" with version "1.16-windows"
00:00:07.151739          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.152045          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.171424          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:07.343137          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_871bdfeaab3fd787\boinc_871bdfeaab3fd787.vbox" with version "1.16-windows"
00:00:07.427254          Launched VM: 76840208 pid: 17640 (0x44e8) frontend: headless name: boinc_74930aab2117c5a7
00:00:07.696179          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.696470          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.715267          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:08.015262          Launched VM: 77016432 pid: 10208 (0x27e0) frontend: headless name: boinc_871bdfeaab3fd787
00:00:11.627234          Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_74930aab2117c5a7\boinc_74930aab2117c5a7.vbox" with version "1.16-windows"
00:00:11.798448          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:12.201069          Saving settings file "C:\Users\Admin\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:12.243591          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_871bdfeaab3fd787\boinc_871bdfeaab3fd787.vbox" with version "1.16-windows"
00:00:12.421815          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:12.540599          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_871bdfeaab3fd787\boinc_871bdfeaab3fd787.vbox" with version "1.16-windows"
00:00:12.795661          Saving settings file "C:\Users\Admin\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:18.107627 main     VirtualBox: object deletion starts
00:00:18.109653 main     HostDnsMonitor: shutting down ...
00:00:18.109831 main     HostDnsMonitor: shut down
00:00:18.113420 Watcher  ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0
00:00:18.113714 main     VirtualBox: object deleted

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

imum Devices per SATA Port:   1
Maximum PIIX3 SCSI Controllers:  1
Maximum ICH9 SCSI Controllers:   8
Maximum SCSI Port count:         16
Maximum Devices per SCSI Port:   1
Maximum SAS PIIX3 Controllers:   1
Maximum SAS ICH9 Controllers:    8
Maximum SAS Port count:          255
Maximum Devices per SAS Port:    1
Maximum NVMe PIIX3 Controllers:  1
Maximum NVMe ICH9 Controllers:   8
Maximum NVMe Port count:         255
Maximum Devices per NVMe Port:   1
Maximum virtio-scsi PIIX3 Controllers:  1
Maximum virtio-scsi ICH9 Controllers:   8
Maximum virtio-scsi Port count:         256
Maximum Devices per virtio-scsi Port:   1
Maximum PIIX3 Floppy Controllers:1
Maximum ICH9 Floppy Controllers: 1
Maximum Floppy Port count:       1
Maximum Devices per Floppy Port: 2
Default machine folder:          C:\Users\Admin\VirtualBox VMs
Raw-mode Supported:              no
Exclusive HW virtualization use: off
Default hard disk format:        VDI
VRDE auth library:               VBoxAuth
Webservice auth. library:        VBoxAuth
Remote desktop ExtPack:          
Log history count:               3
Default frontend:                
Default audio driver:            DirectSound
Autostart database path:         
Default Guest Additions ISO:     C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso
Logging Level:                   all
Proxy Mode:                      System
Proxy URL:                       

2021-06-14 06:02:51 (8552): 
Command: VBoxManage -q list hostinfo 
Exit Code: 0
Output:
Host Information:

Host time: 2021-06-14T04:02:51.066000000Z
Processor online count: 6
Processor count: 6
Processor online core count: 3
Processor core count: 3
Processor supports HW virtualization: no
Processor supports PAE: yes
Processor supports long mode: yes
Processor supports nested paging: no
Processor supports unrestricted guest: no
Processor supports nested HW virtualization: no
Processor#0 speed: unknown
Processor#0 description: AMD FX(tm)-6300 Six-Core Processor
Processor#1 speed: unknown
Processor#1 description: AMD FX(tm)-6300 Six-Core Processor
Processor#2 speed: unknown
Processor#2 description: AMD FX(tm)-6300 Six-Core Processor
Processor#3 speed: unknown
Processor#3 description: AMD FX(tm)-6300 Six-Core Processor
Processor#4 speed: unknown
Processor#4 description: AMD FX(tm)-6300 Six-Core Processor
Processor#5 speed: unknown
Processor#5 description: AMD FX(tm)-6300 Six-Core Processor
Memory size: 7661 MByte
Memory available: 2660 MByte
Operating system: Windows 10
Operating system version: 10.0.19042

2021-06-14 06:02:51 (8552): 
Command: VBoxManage -q showvminfo "boinc_871bdfeaab3fd787" --machinereadable 
Exit Code: -2135228415
Output:
VBoxManage.exe: error: Could not find a registered machine named 'boinc_871bdfeaab3fd787'
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown
VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2715 of file VBoxManageInfo.cpp

2021-06-14 06:02:51 (8552): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\1/vm_image.vdi" 
Exit Code: -2135228412
Output:
VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\1\vm_image.vdi' (VERR_FILE_NOT_FOUND)
VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp

2021-06-14 06:02:52 (8552): 
Command: VBoxManage -q createvm --name "boinc_871bdfeaab3fd787" --basefolder "C:\ProgramData\BOINC\slots\1" --ostype "Linux26_64" --register
Exit Code: 0
Output:
Virtual machine 'boinc_871bdfeaab3fd787' is created and registered.
UUID: 7fae8b02-60fd-47e2-a308-8896c3b2784a
Settings file: 'C:\ProgramData\BOINC\slots\1\boinc_871bdfeaab3fd787\boinc_871bdfeaab3fd787.vbox'

2021-06-14 06:02:52 (8552): 
Command: VBoxManage -q modifyvm "boinc_871bdfeaab3fd787" --description "08373039_28_0" 
Exit Code: 0
Output:

2021-06-14 06:02:52 (8552): 
Command: VBoxManage -q modifyvm "boinc_871bdfeaab3fd787" --memory 3072 
Exit Code: 0
Output:

2021-06-14 06:02:52 (8552): 
Command: VBoxManage -q modifyvm "boinc_871bdfeaab3fd787" --cpus 1 
Exit Code: 0
Output:

2021-06-14 06:02:53 (8552): 
Command: VBoxManage -q modifyvm "boinc_871bdfeaab3fd787" --acpi on --ioapic on 
Exit Code: 0
Output:

2021-06-14 06:02:53 (8552): 
Command: VBoxManage -q modifyvm "boinc_871bdfeaab3fd787" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2021-06-14 06:02:53 (8552): 
Command: VBoxManage -q modifyvm "boinc_871bdfeaab3fd787" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2021-06-14 06:02:54 (8552): 
Command: VBoxManage -q modifyvm "boinc_871bdfeaab3fd787" --cableconnected1 on 
Exit Code: 0
Output:

2021-06-14 06:02:54 (8552): 
Command: VBoxManage -q modifyvm "boinc_871bdfeaab3fd787" --usb off 
Exit Code: 0
Output:

2021-06-14 06:02:54 (8552): 
Command: VBoxManage -q modifyvm "boinc_871bdfeaab3fd787" --uart1 off --uart2 off 
Exit Code: 0
Output:

2021-06-14 06:02:54 (8552): 
Command: VBoxManage -q modifyvm "boinc_871bdfeaab3fd787" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2021-06-14 06:02:55 (8552): 
Command: VBoxManage -q modifyvm "boinc_871bdfeaab3fd787" --audio none 
Exit Code: 0
Output:

2021-06-14 06:02:55 (8552): 
Command: VBoxManage -q modifyvm "boinc_871bdfeaab3fd787" --clipboard disabled 
Exit Code: 0
Output:

2021-06-14 06:02:55 (8552): 
Command: VBoxManage -q modifyvm "boinc_871bdfeaab3fd787" --draganddrop disabled 
Exit Code: 0
Output:

2021-06-14 06:02:55 (8552): 
Command: VBoxManage -q storagectl "boinc_871bdfeaab3fd787" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2021-06-14 06:02:56 (8552): 
Command: VBoxManage -q storageattach "boinc_871bdfeaab3fd787" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\ProgramData\BOINC\slots\1/vm_isocontext.iso" 
Exit Code: 0
Output:

2021-06-14 06:02:56 (8552): 
Command: VBoxManage -q storageattach "boinc_871bdfeaab3fd787" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2021-06-14 06:02:56 (8552): 
Command: VBoxManage -q bandwidthctl "boinc_871bdfeaab3fd787" add "boinc_871bdfeaab3fd787_net" --type network --limit 1024G 
Exit Code: 0
Output:

2021-06-14 06:02:57 (8552): 
Command: VBoxManage -q sharedfolder add "boinc_871bdfeaab3fd787" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\1/shared"
Exit Code: 0
Output:

2021-06-14 06:03:01 (8552): 
Command: VBoxManage -q startvm "boinc_871bdfeaab3fd787" --type headless
Exit Code: -2147467259
Output:
Waiting for VM "boinc_871bdfeaab3fd787" to power on...
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: AMD-V is disabled in the BIOS (or by the host OS) (VERR_SVM_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole

2021-06-14 06:03:01 (8552): 
Command: VBoxManage -q snapshot "boinc_871bdfeaab3fd787" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2021-06-14 06:03:02 (8552): 
Command: VBoxManage -q bandwidthctl "boinc_871bdfeaab3fd787" remove "boinc_871bdfeaab3fd787_net" 
Exit Code: 0
Output:

2021-06-14 06:03:02 (8552): 
Command: VBoxManage -q unregistervm "boinc_871bdfeaab3fd787" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

2021-06-14 06:03:02 (8552): 
Command: VBoxManage -q closemedium dvd "C:\ProgramData\BOINC\slots\1/vm_isocontext.iso" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

06:03:08 (8552): called boinc_finish(-2147467259)

</stderr_txt>
]]>


©2024 COPYRIGHT 2017-2018 NCN