Task 10598389

Name 08374881_36_0
Workunit 8284379
Created 15 Jun 2021, 8:02:46 UTC
Sent 15 Jun 2021, 16:09:26 UTC
Report deadline 20 Jun 2021, 16:09:26 UTC
Received 16 Jun 2021, 11:44:14 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status -2147467259 (0x80004005) Unknown error code
Computer ID 10598
Run time 19 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 4.00 GFLOPS
Application version boinc2docker v1.14 (vbox64_mt)
windows_x86_64
Peak working set size 10.91 MB
Peak swap size 7.16 MB
Peak disk usage 498.84 MB

Stderr output

<core_client_version>7.16.11</core_client_version>
<![CDATA[
<message>
Unspecified error
 (0x80004005) - exit code 2147500037 (0x80004005)</message>
<stderr_txt>
2021-06-15 17:10:03 (2164): Detected: vboxwrapper 26202
2021-06-15 17:10:03 (2164): Detected: BOINC client v7.16.11
2021-06-15 17:10:05 (2164): Detected: VirtualBox VboxManage Interface (Version: 6.1.12)
2021-06-15 17:10:05 (2164): Create VM. (boinc_25ba1b23431cda12, slot#8)
2021-06-15 17:10:05 (2164): Updating drive controller type and model for desired configuration.
2021-06-15 17:10:06 (2164): Setting Memory Size for VM. (3072MB)
2021-06-15 17:10:06 (2164): Setting CPU Count for VM. (1)
2021-06-15 17:10:06 (2164): Setting Chipset Options for VM.
2021-06-15 17:10:07 (2164): Setting Boot Options for VM.
2021-06-15 17:10:07 (2164): Setting Network Configuration for NAT.
2021-06-15 17:10:07 (2164): Enabling VM Network Access.
2021-06-15 17:10:08 (2164): Disabling USB Support for VM.
2021-06-15 17:10:08 (2164): Disabling COM Port Support for VM.
2021-06-15 17:10:08 (2164): Disabling LPT Port Support for VM.
2021-06-15 17:10:08 (2164): Disabling Audio Support for VM.
2021-06-15 17:10:09 (2164): Disabling Clipboard Support for VM.
2021-06-15 17:10:09 (2164): Disabling Drag and Drop Support for VM.
2021-06-15 17:10:09 (2164): Adding storage controller(s) to VM.
2021-06-15 17:10:09 (2164): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso)
2021-06-15 17:10:10 (2164): Adding VirtualBox Guest Additions to VM.
2021-06-15 17:10:10 (2164): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2021-06-15 17:10:10 (2164): Enabling shared directory for VM.
2021-06-15 17:10:11 (2164): Starting VM using VBoxManage interface. (boinc_25ba1b23431cda12, slot#8)
2021-06-15 17:10:14 (2164): Error in start VM for VM: -2147467259
Command:
VBoxManage -q startvm "boinc_25ba1b23431cda12" --type headless
Output:
Waiting for VM "boinc_25ba1b23431cda12" to power on...
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole

2021-06-15 17:10:14 (2164): VM failed to start.
2021-06-15 17:10:14 (2164): Could not start 
2021-06-15 17:10:14 (2164): ERROR: VM failed to start
2021-06-15 17:10:14 (2164): Powering off VM.
2021-06-15 17:10:14 (2164): Deregistering VM. (boinc_25ba1b23431cda12, slot#8)
2021-06-15 17:10:14 (2164): Removing network bandwidth throttle group from VM.
2021-06-15 17:10:15 (2164): Removing VM from VirtualBox.
2021-06-15 17:10:15 (2164): Removing virtual ISO 9660 disk from VirtualBox.

    Hypervisor System Log:

00:00:00.288564          netIfIsWireless: CreateFile on '\\.\{AAE76E7F-85F6-49C6-8001-D34A9AAAA2FB}' failed with rcWin=2 (0x2) - ignoring
00:00:00.308284          HostDnsMonitor: initializing
00:00:00.325180          HostDnsMonitor: updating information
00:00:00.325281          HostDnsMonitor: old information
00:00:00.325282            no server entries
00:00:00.325283            no domain set
00:00:00.325284            no search string entries
00:00:00.325284          HostDnsMonitor: new information
00:00:00.325285            server 1: 192.168.1.1
00:00:00.325286            no domain set
00:00:00.325287            no search string entries
00:00:00.559671          SUPR0QueryVTCaps -> VERR_VMX_MSR_ALL_VMX_DISABLED
00:00:00.560690          VD: VDInit finished with VINF_SUCCESS
00:00:00.568078          VirtualBox: object created
00:00:01.139156          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={Could not find a registered machine named 'boinc_25ba1b23431cda12'}, preserve=false aResultDetail=0
00:00:01.400045          ERROR [COM]: aRC=VBOX_E_FILE_ERROR (0x80bb0004) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Could not find file for the medium 'C:\ProgramData\BOINC\slots\8\vm_image.vdi' (VERR_FILE_NOT_FOUND)}, preserve=false aResultDetail=-102
00:00:01.678490          Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_25ba1b23431cda12\boinc_25ba1b23431cda12.vbox" with version "1.16-windows"
00:00:01.689721          Saving settings file "C:\Users\nessu\.VirtualBox\VirtualBox.xml" with version "1.14-windows"
00:00:01.942079          Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_25ba1b23431cda12\boinc_25ba1b23431cda12.vbox" with version "1.16-windows"
00:00:02.206856          Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_25ba1b23431cda12\boinc_25ba1b23431cda12.vbox" with version "1.16-windows"
00:00:02.471523          Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_25ba1b23431cda12\boinc_25ba1b23431cda12.vbox" with version "1.16-windows"
00:00:02.735820          Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_25ba1b23431cda12\boinc_25ba1b23431cda12.vbox" with version "1.16-windows"
00:00:02.999505          Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_25ba1b23431cda12\boinc_25ba1b23431cda12.vbox" with version "1.16-windows"
00:00:03.265865          Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_25ba1b23431cda12\boinc_25ba1b23431cda12.vbox" with version "1.16-windows"
00:00:03.527578          Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_25ba1b23431cda12\boinc_25ba1b23431cda12.vbox" with version "1.16-windows"
00:00:03.791342          Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_25ba1b23431cda12\boinc_25ba1b23431cda12.vbox" with version "1.16-windows"
00:00:04.057109          Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_25ba1b23431cda12\boinc_25ba1b23431cda12.vbox" with version "1.16-windows"
00:00:04.322576          Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_25ba1b23431cda12\boinc_25ba1b23431cda12.vbox" with version "1.16-windows"
00:00:04.584782          Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_25ba1b23431cda12\boinc_25ba1b23431cda12.vbox" with version "1.16-windows"
00:00:04.846189          Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_25ba1b23431cda12\boinc_25ba1b23431cda12.vbox" with version "1.16-windows"
00:00:05.113874          Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_25ba1b23431cda12\boinc_25ba1b23431cda12.vbox" with version "1.16-windows"
00:00:05.376667          Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_25ba1b23431cda12\boinc_25ba1b23431cda12.vbox" with version "1.16-windows"
00:00:05.639720          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:05.647273          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:05.649279          Saving settings file "C:\Users\nessu\.VirtualBox\VirtualBox.xml" with version "1.14-windows"
00:00:05.660996          Saving settings file "C:\Users\nessu\.VirtualBox\VirtualBox.xml" with version "1.14-windows"
00:00:05.672233          Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_25ba1b23431cda12\boinc_25ba1b23431cda12.vbox" with version "1.16-windows"
00:00:05.918350          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:05.921960          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:05.924070          Saving settings file "C:\Users\nessu\.VirtualBox\VirtualBox.xml" with version "1.14-windows"
00:00:05.936334          Saving settings file "C:\Users\nessu\.VirtualBox\VirtualBox.xml" with version "1.14-windows"
00:00:05.948197          Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_25ba1b23431cda12\boinc_25ba1b23431cda12.vbox" with version "1.16-windows"
00:00:06.176841          Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_25ba1b23431cda12\boinc_25ba1b23431cda12.vbox" with version "1.16-windows"
00:00:06.441757          Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_25ba1b23431cda12\boinc_25ba1b23431cda12.vbox" with version "1.16-windows"
00:00:06.719411          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.719861          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.744337          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:06.970076          Launched VM: 103617968 pid: 15988 (0x3e74) frontend: headless name: boinc_25ba1b23431cda12
00:00:10.490522          Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_25ba1b23431cda12\boinc_25ba1b23431cda12.vbox" with version "1.16-windows"
00:00:10.615539          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:10.731567          Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_25ba1b23431cda12\boinc_25ba1b23431cda12.vbox" with version "1.16-windows"
00:00:10.984442          Saving settings file "C:\Users\nessu\.VirtualBox\VirtualBox.xml" with version "1.14-windows"
00:00:16.252491 main     VirtualBox: object deletion starts
00:00:16.264533 main     HostDnsMonitor: shutting down ...
00:00:16.264697 main     HostDnsMonitor: shut down
00:00:16.271641 Watcher  ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0
00:00:16.272549 main     VirtualBox: object deleted

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

ICH9 Controllers:    8
Maximum SAS Port count:          255
Maximum Devices per SAS Port:    1
Maximum NVMe PIIX3 Controllers:  1
Maximum NVMe ICH9 Controllers:   8
Maximum NVMe Port count:         255
Maximum Devices per NVMe Port:   1
Maximum virtio-scsi PIIX3 Controllers:  1
Maximum virtio-scsi ICH9 Controllers:   8
Maximum virtio-scsi Port count:         256
Maximum Devices per virtio-scsi Port:   1
Maximum PIIX3 Floppy Controllers:1
Maximum ICH9 Floppy Controllers: 1
Maximum Floppy Port count:       1
Maximum Devices per Floppy Port: 2
Default machine folder:          C:\Users\nessu\VirtualBox VMs
Raw-mode Supported:              no
Exclusive HW virtualization use: off
Default hard disk format:        VDI
VRDE auth library:               VBoxAuth
Webservice auth. library:        VBoxAuth
Remote desktop ExtPack:          
Log history count:               3
Default frontend:                
Default audio driver:            DirectSound
Autostart database path:         
Default Guest Additions ISO:     C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso
Logging Level:                   all
Proxy Mode:                      System
Proxy URL:                       

2021-06-15 17:10:05 (2164): 
Command: VBoxManage -q list hostinfo 
Exit Code: 0
Output:
Host Information:

Host time: 2021-06-15T16:10:05.219000000Z
Processor online count: 8
Processor count: 8
Processor online core count: 4
Processor core count: 4
Processor supports HW virtualization: no
Processor supports PAE: yes
Processor supports long mode: yes
Processor supports nested paging: no
Processor supports unrestricted guest: no
Processor supports nested HW virtualization: no
Processor#0 speed: unknown
Processor#0 description: Intel(R) Core(TM) i7-6700 CPU @ 3.40GHz
Processor#1 speed: unknown
Processor#1 description: Intel(R) Core(TM) i7-6700 CPU @ 3.40GHz
Processor#2 speed: unknown
Processor#2 description: Intel(R) Core(TM) i7-6700 CPU @ 3.40GHz
Processor#3 speed: unknown
Processor#3 description: Intel(R) Core(TM) i7-6700 CPU @ 3.40GHz
Processor#4 speed: unknown
Processor#4 description: Intel(R) Core(TM) i7-6700 CPU @ 3.40GHz
Processor#5 speed: unknown
Processor#5 description: Intel(R) Core(TM) i7-6700 CPU @ 3.40GHz
Processor#6 speed: unknown
Processor#6 description: Intel(R) Core(TM) i7-6700 CPU @ 3.40GHz
Processor#7 speed: unknown
Processor#7 description: Intel(R) Core(TM) i7-6700 CPU @ 3.40GHz
Memory size: 65455 MByte
Memory available: 53216 MByte
Operating system: Windows 8
Operating system version: 6.2.9200

2021-06-15 17:10:05 (2164): 
Command: VBoxManage -q showvminfo "boinc_25ba1b23431cda12" --machinereadable 
Exit Code: -2135228415
Output:
VBoxManage.exe: error: Could not find a registered machine named 'boinc_25ba1b23431cda12'
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown
VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2715 of file VBoxManageInfo.cpp

2021-06-15 17:10:05 (2164): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\8/vm_image.vdi" 
Exit Code: -2135228412
Output:
VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\8\vm_image.vdi' (VERR_FILE_NOT_FOUND)
VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp

2021-06-15 17:10:06 (2164): 
Command: VBoxManage -q createvm --name "boinc_25ba1b23431cda12" --basefolder "C:\ProgramData\BOINC\slots\8" --ostype "Linux26_64" --register
Exit Code: 0
Output:
Virtual machine 'boinc_25ba1b23431cda12' is created and registered.
UUID: 7a2835cf-520c-40c9-9c5b-a44a957eafdc
Settings file: 'C:\ProgramData\BOINC\slots\8\boinc_25ba1b23431cda12\boinc_25ba1b23431cda12.vbox'

2021-06-15 17:10:06 (2164): 
Command: VBoxManage -q modifyvm "boinc_25ba1b23431cda12" --description "08374881_36_0" 
Exit Code: 0
Output:

2021-06-15 17:10:06 (2164): 
Command: VBoxManage -q modifyvm "boinc_25ba1b23431cda12" --memory 3072 
Exit Code: 0
Output:

2021-06-15 17:10:06 (2164): 
Command: VBoxManage -q modifyvm "boinc_25ba1b23431cda12" --cpus 1 
Exit Code: 0
Output:

2021-06-15 17:10:07 (2164): 
Command: VBoxManage -q modifyvm "boinc_25ba1b23431cda12" --acpi on --ioapic on 
Exit Code: 0
Output:

2021-06-15 17:10:07 (2164): 
Command: VBoxManage -q modifyvm "boinc_25ba1b23431cda12" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2021-06-15 17:10:07 (2164): 
Command: VBoxManage -q modifyvm "boinc_25ba1b23431cda12" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2021-06-15 17:10:08 (2164): 
Command: VBoxManage -q modifyvm "boinc_25ba1b23431cda12" --cableconnected1 on 
Exit Code: 0
Output:

2021-06-15 17:10:08 (2164): 
Command: VBoxManage -q modifyvm "boinc_25ba1b23431cda12" --usb off 
Exit Code: 0
Output:

2021-06-15 17:10:08 (2164): 
Command: VBoxManage -q modifyvm "boinc_25ba1b23431cda12" --uart1 off --uart2 off 
Exit Code: 0
Output:

2021-06-15 17:10:08 (2164): 
Command: VBoxManage -q modifyvm "boinc_25ba1b23431cda12" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2021-06-15 17:10:09 (2164): 
Command: VBoxManage -q modifyvm "boinc_25ba1b23431cda12" --audio none 
Exit Code: 0
Output:

2021-06-15 17:10:09 (2164): 
Command: VBoxManage -q modifyvm "boinc_25ba1b23431cda12" --clipboard disabled 
Exit Code: 0
Output:

2021-06-15 17:10:09 (2164): 
Command: VBoxManage -q modifyvm "boinc_25ba1b23431cda12" --draganddrop disabled 
Exit Code: 0
Output:

2021-06-15 17:10:09 (2164): 
Command: VBoxManage -q storagectl "boinc_25ba1b23431cda12" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2021-06-15 17:10:10 (2164): 
Command: VBoxManage -q storageattach "boinc_25ba1b23431cda12" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\ProgramData\BOINC\slots\8/vm_isocontext.iso" 
Exit Code: 0
Output:

2021-06-15 17:10:10 (2164): 
Command: VBoxManage -q storageattach "boinc_25ba1b23431cda12" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2021-06-15 17:10:10 (2164): 
Command: VBoxManage -q bandwidthctl "boinc_25ba1b23431cda12" add "boinc_25ba1b23431cda12_net" --type network --limit 1024G 
Exit Code: 0
Output:

2021-06-15 17:10:10 (2164): 
Command: VBoxManage -q sharedfolder add "boinc_25ba1b23431cda12" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\8/shared"
Exit Code: 0
Output:

2021-06-15 17:10:14 (2164): 
Command: VBoxManage -q startvm "boinc_25ba1b23431cda12" --type headless
Exit Code: -2147467259
Output:
Waiting for VM "boinc_25ba1b23431cda12" to power on...
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole

2021-06-15 17:10:14 (2164): 
Command: VBoxManage -q snapshot "boinc_25ba1b23431cda12" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2021-06-15 17:10:15 (2164): 
Command: VBoxManage -q bandwidthctl "boinc_25ba1b23431cda12" remove "boinc_25ba1b23431cda12_net" 
Exit Code: 0
Output:

2021-06-15 17:10:15 (2164): 
Command: VBoxManage -q unregistervm "boinc_25ba1b23431cda12" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

2021-06-15 17:10:15 (2164): 
Command: VBoxManage -q closemedium dvd "C:\ProgramData\BOINC\slots\8/vm_isocontext.iso" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

17:10:20 (2164): called boinc_finish(-2147467259)

</stderr_txt>
]]>


©2024 COPYRIGHT 2017-2018 NCN