Task 10644140

Name 08368581_06_1
Workunit 8137316
Created 17 Jun 2021, 7:08:49 UTC
Sent 17 Jun 2021, 7:32:25 UTC
Report deadline 22 Jun 2021, 7:32:25 UTC
Received 17 Jun 2021, 11:59:51 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status -1073741819 (0xC0000005) STATUS_ACCESS_VIOLATION
Computer ID 11577
Run time 36 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 4.07 GFLOPS
Application version boinc2docker v1.14 (vbox64_mt)
windows_x86_64
Peak working set size 10.57 MB
Peak swap size 6.22 MB
Peak disk usage 499.86 MB

Stderr output

<core_client_version>7.16.11</core_client_version>
<![CDATA[
<message>
(unknown error) - exit code 3221225477 (0xc0000005)</message>
<stderr_txt>
2021-06-17 09:59:00 (10064): Detected: vboxwrapper 26202
2021-06-17 09:59:00 (10064): Detected: BOINC client v7.16.11
2021-06-17 09:59:12 (10064): Detected: VirtualBox VboxManage Interface (Version: 5.2.8)
2021-06-17 09:59:13 (10064): Create VM. (boinc_3c192a2106b87cd3, slot#18)
2021-06-17 09:59:13 (10064): Updating drive controller type and model for desired configuration.
2021-06-17 09:59:13 (10064): Setting Memory Size for VM. (3072MB)
2021-06-17 09:59:14 (10064): Setting CPU Count for VM. (1)
2021-06-17 09:59:14 (10064): Setting Chipset Options for VM.
2021-06-17 09:59:14 (10064): Setting Boot Options for VM.
2021-06-17 09:59:14 (10064): Setting Network Configuration for NAT.
2021-06-17 09:59:15 (10064): Enabling VM Network Access.
2021-06-17 09:59:15 (10064): Disabling USB Support for VM.
2021-06-17 09:59:15 (10064): Disabling COM Port Support for VM.
2021-06-17 09:59:15 (10064): Disabling LPT Port Support for VM.
2021-06-17 09:59:16 (10064): Disabling Audio Support for VM.
2021-06-17 09:59:16 (10064): Disabling Clipboard Support for VM.
2021-06-17 09:59:16 (10064): Disabling Drag and Drop Support for VM.
2021-06-17 09:59:17 (10064): Adding storage controller(s) to VM.
2021-06-17 09:59:17 (10064): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso)
2021-06-17 09:59:17 (10064): Adding VirtualBox Guest Additions to VM.
2021-06-17 09:59:17 (10064): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2021-06-17 09:59:18 (10064): Enabling shared directory for VM.
2021-06-17 09:59:18 (10064): Starting VM using VBoxManage interface. (boinc_3c192a2106b87cd3, slot#18)
2021-06-17 09:59:22 (10064): Error in start VM for VM: -1073741819
Command:
VBoxManage -q startvm "boinc_3c192a2106b87cd3" --type headless
Output:
Waiting for VM "boinc_3c192a2106b87cd3" to power on...
VBoxManage.exe: error: The virtual machine 'boinc_3c192a2106b87cd3' has terminated unexpectedly during startup with exit code -1073741819 (0xc0000005)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine

2021-06-17 09:59:22 (10064): VM failed to start.
2021-06-17 09:59:22 (10064): Could not start 
2021-06-17 09:59:22 (10064): ERROR: VM failed to start
2021-06-17 09:59:22 (10064): Powering off VM.
2021-06-17 09:59:22 (10064): Deregistering VM. (boinc_3c192a2106b87cd3, slot#18)
2021-06-17 09:59:23 (10064): Removing network bandwidth throttle group from VM.
2021-06-17 09:59:23 (10064): Removing VM from VirtualBox.
2021-06-17 09:59:23 (10064): Removing virtual ISO 9660 disk from VirtualBox.

    Hypervisor System Log:

00:00:10.264286            C:\WINDOWS\system32\DRIVERS\VBoxNetAdp6.sys (Version: 5.2.8.21009)
00:00:10.267285          Loading settings file "C:\vms\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:10.545250          netIfIsWireless: CreateFile on '\\.\{C14D2952-A0DF-41DC-88C7-73905601DABA}' failed with rcWin=2 (0x2) - ignoring
00:00:10.574272          HostDnsMonitor: old information
00:00:10.574272            no server entries
00:00:10.574272            no domain set
00:00:10.574272            no search string entries
00:00:10.574272          HostDnsMonitor: new information
00:00:10.574272            server 1: 192.168.178.1
00:00:10.574272            domain: fritz.box
00:00:10.574272            no search string entries
00:00:10.574272          HostDnsMonitorProxy::notify
00:00:10.748261          SUPR0QueryVTCaps -> VERR_VMX_MSR_ALL_VMX_DISABLED
00:00:10.754259          VD: VDInit finished with VINF_SUCCESS
00:00:10.756258          Loading settings file "C:\Users\harry\appdata\roaming\sys00_1\sys00_1.vbox" with version "1.16-windows"
00:00:10.758257          VirtualBox: object created
00:00:11.442038          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={9570b9d5-f1a1-448a-10c5-e12f5285adad} aComponent={VirtualBoxWrap} aText={Could not find a registered machine named 'boinc_3c192a2106b87cd3'}, preserve=false aResultDetail=0
00:00:11.711952          ERROR [COM]: aRC=VBOX_E_FILE_ERROR (0x80bb0004) aIID={4afe423b-43e0-e9d0-82e8-ceb307940dda} aComponent={MediumWrap} aText={Could not find file for the medium 'C:\ProgramData\BOINC\slots\18\vm_image.vdi' (VERR_FILE_NOT_FOUND)}, preserve=false aResultDetail=0
00:00:12.009855          Saving settings file "C:\ProgramData\BOINC\slots\18\boinc_3c192a2106b87cd3\boinc_3c192a2106b87cd3.vbox" with version "1.16-windows"
00:00:12.015853          Saving settings file "C:\vms\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:12.288766          Saving settings file "C:\ProgramData\BOINC\slots\18\boinc_3c192a2106b87cd3\boinc_3c192a2106b87cd3.vbox" with version "1.16-windows"
00:00:12.563678          Saving settings file "C:\ProgramData\BOINC\slots\18\boinc_3c192a2106b87cd3\boinc_3c192a2106b87cd3.vbox" with version "1.16-windows"
00:00:12.840773          Saving settings file "C:\ProgramData\BOINC\slots\18\boinc_3c192a2106b87cd3\boinc_3c192a2106b87cd3.vbox" with version "1.16-windows"
00:00:13.123683          Saving settings file "C:\ProgramData\BOINC\slots\18\boinc_3c192a2106b87cd3\boinc_3c192a2106b87cd3.vbox" with version "1.16-windows"
00:00:13.392596          Saving settings file "C:\ProgramData\BOINC\slots\18\boinc_3c192a2106b87cd3\boinc_3c192a2106b87cd3.vbox" with version "1.16-windows"
00:00:13.673506          Saving settings file "C:\ProgramData\BOINC\slots\18\boinc_3c192a2106b87cd3\boinc_3c192a2106b87cd3.vbox" with version "1.16-windows"
00:00:13.936422          Saving settings file "C:\ProgramData\BOINC\slots\18\boinc_3c192a2106b87cd3\boinc_3c192a2106b87cd3.vbox" with version "1.16-windows"
00:00:14.239324          Saving settings file "C:\ProgramData\BOINC\slots\18\boinc_3c192a2106b87cd3\boinc_3c192a2106b87cd3.vbox" with version "1.16-windows"
00:00:14.511236          Saving settings file "C:\ProgramData\BOINC\slots\18\boinc_3c192a2106b87cd3\boinc_3c192a2106b87cd3.vbox" with version "1.16-windows"
00:00:14.790147          Saving settings file "C:\ProgramData\BOINC\slots\18\boinc_3c192a2106b87cd3\boinc_3c192a2106b87cd3.vbox" with version "1.16-windows"
00:00:15.062060          Saving settings file "C:\ProgramData\BOINC\slots\18\boinc_3c192a2106b87cd3\boinc_3c192a2106b87cd3.vbox" with version "1.16-windows"
00:00:15.336972          Saving settings file "C:\ProgramData\BOINC\slots\18\boinc_3c192a2106b87cd3\boinc_3c192a2106b87cd3.vbox" with version "1.16-windows"
00:00:15.622884          Saving settings file "C:\ProgramData\BOINC\slots\18\boinc_3c192a2106b87cd3\boinc_3c192a2106b87cd3.vbox" with version "1.16-windows"
00:00:15.896302          Saving settings file "C:\ProgramData\BOINC\slots\18\boinc_3c192a2106b87cd3\boinc_3c192a2106b87cd3.vbox" with version "1.16-windows"
00:00:16.171214          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85cd948e-a71f-4289-281e-0ca7ad48cd89} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:16.175213          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85cd948e-a71f-4289-281e-0ca7ad48cd89} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:16.176212          Saving settings file "C:\ProgramData\BOINC\slots\18\boinc_3c192a2106b87cd3\boinc_3c192a2106b87cd3.vbox" with version "1.16-windows"
00:00:16.458122          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85cd948e-a71f-4289-281e-0ca7ad48cd89} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:16.462120          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85cd948e-a71f-4289-281e-0ca7ad48cd89} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:16.463120          Saving settings file "C:\ProgramData\BOINC\slots\18\boinc_3c192a2106b87cd3\boinc_3c192a2106b87cd3.vbox" with version "1.16-windows"
00:00:16.750028          Saving settings file "C:\ProgramData\BOINC\slots\18\boinc_3c192a2106b87cd3\boinc_3c192a2106b87cd3.vbox" with version "1.16-windows"
00:00:17.023940          Saving settings file "C:\ProgramData\BOINC\slots\18\boinc_3c192a2106b87cd3\boinc_3c192a2106b87cd3.vbox" with version "1.16-windows"
00:00:17.331347          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85cd948e-a71f-4289-281e-0ca7ad48cd89} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:17.331347          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85cd948e-a71f-4289-281e-0ca7ad48cd89} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:17.342343          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85cd948e-a71f-4289-281e-0ca7ad48cd89} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:21.587996 Watcher  ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85cd948e-a71f-4289-281e-0ca7ad48cd89} aComponent={MachineWrap} aText={The virtual machine 'boinc_3c192a2106b87cd3' has terminated unexpectedly during startup with exit code -1073741819 (0xc0000005)}, preserve=false aResultDetail=0
00:00:21.717953          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85cd948e-a71f-4289-281e-0ca7ad48cd89} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:21.826919          Saving settings file "C:\ProgramData\BOINC\slots\18\boinc_3c192a2106b87cd3\boinc_3c192a2106b87cd3.vbox" with version "1.16-windows"
00:00:22.123328          Saving settings file "C:\vms\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:27.437140 main     VirtualBox: object deletion starts
00:00:27.437140 main     ERROR [COM]: aRC=VBOX_E_OBJECT_IN_USE (0x80bb000c) aIID={4afe423b-43e0-e9d0-82e8-ceb307940dda} aComponent={MediumWrap} aText={Medium 'C:\Users\harry\appdata\roaming\sys00_1\sys00-disk001.vmdk' cannot be closed because it is still attached to 1 virtual machines}, preserve=false aResultDetail=0
00:00:27.440139 Watcher  ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={9570b9d5-f1a1-448a-10c5-e12f5285adad} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0
00:00:27.440139 main     VirtualBox: object deleted

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

     255
Maximum Devices per SAS Port:    1
Maximum NVMe PIIX3 Controllers:  1
Maximum NVMe ICH9 Controllers:   8
Maximum NVMe Port count:         255
Maximum Devices per NVMe Port:   1
Maximum PIIX3 Floppy Controllers:1
Maximum ICH9 Floppy Controllers: 1
Maximum Floppy Port count:       1
Maximum Devices per Floppy Port: 2
Default machine folder:          C:\Users\harry\appdata\roaming
Raw-mode Supported:              yes
Exclusive HW virtualization use: off
Default hard disk format:        VDI
VRDE auth library:               VBoxAuth
Webservice auth. library:        VBoxAuth
Remote desktop ExtPack:          
Log history count:               3
Default frontend:                
Default audio driver:            DirectSound
Autostart database path:         
Default Guest Additions ISO:     C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso
Logging Level:                   all

2021-06-17 09:59:12 (10064): 
Command: VBoxManage -q list hostinfo 
Exit Code: 0
Output:
Host Information:

Host time: 2021-06-17T07:59:12.380000000Z
Processor online count: 12
Processor count: 12
Processor online core count: 6
Processor core count: 6
Processor supports HW virtualization: no
Processor supports PAE: yes
Processor supports long mode: yes
Processor supports nested paging: no
Processor#0 speed: unknown
Processor#0 description: Intel(R) Core(TM) i7-5820K CPU @ 3.30GHz
Processor#1 speed: unknown
Processor#1 description: Intel(R) Core(TM) i7-5820K CPU @ 3.30GHz
Processor#2 speed: unknown
Processor#2 description: Intel(R) Core(TM) i7-5820K CPU @ 3.30GHz
Processor#3 speed: unknown
Processor#3 description: Intel(R) Core(TM) i7-5820K CPU @ 3.30GHz
Processor#4 speed: unknown
Processor#4 description: Intel(R) Core(TM) i7-5820K CPU @ 3.30GHz
Processor#5 speed: unknown
Processor#5 description: Intel(R) Core(TM) i7-5820K CPU @ 3.30GHz
Processor#6 speed: unknown
Processor#6 description: Intel(R) Core(TM) i7-5820K CPU @ 3.30GHz
Processor#7 speed: unknown
Processor#7 description: Intel(R) Core(TM) i7-5820K CPU @ 3.30GHz
Processor#8 speed: unknown
Processor#8 description: Intel(R) Core(TM) i7-5820K CPU @ 3.30GHz
Processor#9 speed: unknown
Processor#9 description: Intel(R) Core(TM) i7-5820K CPU @ 3.30GHz
Processor#10 speed: unknown
Processor#10 description: Intel(R) Core(TM) i7-5820K CPU @ 3.30GHz
Processor#11 speed: unknown
Processor#11 description: Intel(R) Core(TM) i7-5820K CPU @ 3.30GHz
Memory size: 48989 MByte
Memory available: 35570 MByte
Operating system: Windows 10
Operating system version: 10.0.19042

2021-06-17 09:59:12 (10064): 
Command: VBoxManage -q showvminfo "boinc_3c192a2106b87cd3" --machinereadable 
Exit Code: -2135228415
Output:
VBoxManage.exe: error: Could not find a registered machine named 'boinc_3c192a2106b87cd3'
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown
VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2834 of file VBoxManageInfo.cpp

2021-06-17 09:59:13 (10064): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\18/vm_image.vdi" 
Exit Code: -2135228412
Output:
VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\18\vm_image.vdi' (VERR_FILE_NOT_FOUND)
VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 179 of file VBoxManageDisk.cpp

2021-06-17 09:59:13 (10064): 
Command: VBoxManage -q createvm --name "boinc_3c192a2106b87cd3" --basefolder "C:\ProgramData\BOINC\slots\18" --ostype "Linux26_64" --register
Exit Code: 0
Output:
Virtual machine 'boinc_3c192a2106b87cd3' is created and registered.
UUID: 7eb8040f-103d-4916-9cf6-81fefcb8a8c1
Settings file: 'C:\ProgramData\BOINC\slots\18\boinc_3c192a2106b87cd3\boinc_3c192a2106b87cd3.vbox'

2021-06-17 09:59:13 (10064): 
Command: VBoxManage -q modifyvm "boinc_3c192a2106b87cd3" --description "08368581_06_1" 
Exit Code: 0
Output:

2021-06-17 09:59:14 (10064): 
Command: VBoxManage -q modifyvm "boinc_3c192a2106b87cd3" --memory 3072 
Exit Code: 0
Output:

2021-06-17 09:59:14 (10064): 
Command: VBoxManage -q modifyvm "boinc_3c192a2106b87cd3" --cpus 1 
Exit Code: 0
Output:

2021-06-17 09:59:14 (10064): 
Command: VBoxManage -q modifyvm "boinc_3c192a2106b87cd3" --acpi on --ioapic on 
Exit Code: 0
Output:

2021-06-17 09:59:14 (10064): 
Command: VBoxManage -q modifyvm "boinc_3c192a2106b87cd3" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2021-06-17 09:59:15 (10064): 
Command: VBoxManage -q modifyvm "boinc_3c192a2106b87cd3" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2021-06-17 09:59:15 (10064): 
Command: VBoxManage -q modifyvm "boinc_3c192a2106b87cd3" --cableconnected1 on 
Exit Code: 0
Output:

2021-06-17 09:59:15 (10064): 
Command: VBoxManage -q modifyvm "boinc_3c192a2106b87cd3" --usb off 
Exit Code: 0
Output:

2021-06-17 09:59:15 (10064): 
Command: VBoxManage -q modifyvm "boinc_3c192a2106b87cd3" --uart1 off --uart2 off 
Exit Code: 0
Output:

2021-06-17 09:59:16 (10064): 
Command: VBoxManage -q modifyvm "boinc_3c192a2106b87cd3" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2021-06-17 09:59:16 (10064): 
Command: VBoxManage -q modifyvm "boinc_3c192a2106b87cd3" --audio none 
Exit Code: 0
Output:

2021-06-17 09:59:16 (10064): 
Command: VBoxManage -q modifyvm "boinc_3c192a2106b87cd3" --clipboard disabled 
Exit Code: 0
Output:

2021-06-17 09:59:17 (10064): 
Command: VBoxManage -q modifyvm "boinc_3c192a2106b87cd3" --draganddrop disabled 
Exit Code: 0
Output:

2021-06-17 09:59:17 (10064): 
Command: VBoxManage -q storagectl "boinc_3c192a2106b87cd3" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2021-06-17 09:59:17 (10064): 
Command: VBoxManage -q storageattach "boinc_3c192a2106b87cd3" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\ProgramData\BOINC\slots\18/vm_isocontext.iso" 
Exit Code: 0
Output:

2021-06-17 09:59:17 (10064): 
Command: VBoxManage -q storageattach "boinc_3c192a2106b87cd3" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2021-06-17 09:59:18 (10064): 
Command: VBoxManage -q bandwidthctl "boinc_3c192a2106b87cd3" add "boinc_3c192a2106b87cd3_net" --type network --limit 1024G 
Exit Code: 0
Output:

2021-06-17 09:59:18 (10064): 
Command: VBoxManage -q sharedfolder add "boinc_3c192a2106b87cd3" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\18/shared"
Exit Code: 0
Output:

2021-06-17 09:59:22 (10064): 
Command: VBoxManage -q startvm "boinc_3c192a2106b87cd3" --type headless
Exit Code: -1073741819
Output:
Waiting for VM "boinc_3c192a2106b87cd3" to power on...
VBoxManage.exe: error: The virtual machine 'boinc_3c192a2106b87cd3' has terminated unexpectedly during startup with exit code -1073741819 (0xc0000005)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine

2021-06-17 09:59:22 (10064): 
Command: VBoxManage -q snapshot "boinc_3c192a2106b87cd3" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2021-06-17 09:59:23 (10064): 
Command: VBoxManage -q bandwidthctl "boinc_3c192a2106b87cd3" remove "boinc_3c192a2106b87cd3_net" 
Exit Code: 0
Output:

2021-06-17 09:59:23 (10064): 
Command: VBoxManage -q unregistervm "boinc_3c192a2106b87cd3" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

2021-06-17 09:59:23 (10064): 
Command: VBoxManage -q closemedium dvd "C:\ProgramData\BOINC\slots\18/vm_isocontext.iso" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

09:59:34 (10064): called boinc_finish(-1073741819)

</stderr_txt>
]]>


©2024 COPYRIGHT 2017-2018 NCN