Name | 08368976_40_2 |
Workunit | 8149815 |
Created | 17 Jun 2021, 10:14:59 UTC |
Sent | 17 Jun 2021, 10:30:11 UTC |
Report deadline | 22 Jun 2021, 10:30:11 UTC |
Received | 17 Jun 2021, 10:53:17 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | -2147467259 (0x80004005) Unknown error code |
Computer ID | 9784 |
Run time | 20 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 4.25 GFLOPS |
Application version | boinc2docker v1.14 (vbox64_mt) windows_x86_64 |
Peak working set size | 10.35 MB |
Peak swap size | 6.20 MB |
Peak disk usage | 600.55 MB |
<core_client_version>7.16.11</core_client_version> <![CDATA[ <message> Unspecified error (0x80004005) - exit code 2147500037 (0x80004005)</message> <stderr_txt> 2021-06-17 03:37:45 (7424): Detected: vboxwrapper 26202 2021-06-17 03:37:45 (7424): Detected: BOINC client v7.16.11 2021-06-17 03:37:46 (7424): Detected: VirtualBox VboxManage Interface (Version: 6.1.12) 2021-06-17 03:37:47 (7424): Create VM. (boinc_d465cb8cff08ebce, slot#2) 2021-06-17 03:37:47 (7424): Updating drive controller type and model for desired configuration. 2021-06-17 03:37:48 (7424): Setting Memory Size for VM. (3072MB) 2021-06-17 03:37:48 (7424): Setting CPU Count for VM. (1) 2021-06-17 03:37:48 (7424): Setting Chipset Options for VM. 2021-06-17 03:37:49 (7424): Setting Boot Options for VM. 2021-06-17 03:37:49 (7424): Setting Network Configuration for NAT. 2021-06-17 03:37:49 (7424): Enabling VM Network Access. 2021-06-17 03:37:49 (7424): Disabling USB Support for VM. 2021-06-17 03:37:50 (7424): Disabling COM Port Support for VM. 2021-06-17 03:37:50 (7424): Disabling LPT Port Support for VM. 2021-06-17 03:37:50 (7424): Disabling Audio Support for VM. 2021-06-17 03:37:51 (7424): Disabling Clipboard Support for VM. 2021-06-17 03:37:51 (7424): Disabling Drag and Drop Support for VM. 2021-06-17 03:37:51 (7424): Adding storage controller(s) to VM. 2021-06-17 03:37:51 (7424): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso) 2021-06-17 03:37:52 (7424): Adding VirtualBox Guest Additions to VM. 2021-06-17 03:37:52 (7424): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2021-06-17 03:37:52 (7424): Enabling shared directory for VM. 2021-06-17 03:37:53 (7424): Starting VM using VBoxManage interface. (boinc_d465cb8cff08ebce, slot#2) 2021-06-17 03:37:56 (7424): Error in start VM for VM: -2147467259 Command: VBoxManage -q startvm "boinc_d465cb8cff08ebce" --type headless Output: Waiting for VM "boinc_d465cb8cff08ebce" to power on... VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2021-06-17 03:37:56 (7424): VM failed to start. 2021-06-17 03:37:56 (7424): Could not start 2021-06-17 03:37:56 (7424): ERROR: VM failed to start 2021-06-17 03:37:56 (7424): Powering off VM. 2021-06-17 03:37:56 (7424): Deregistering VM. (boinc_d465cb8cff08ebce, slot#2) 2021-06-17 03:37:56 (7424): Removing network bandwidth throttle group from VM. 2021-06-17 03:37:56 (7424): Removing VM from VirtualBox. 2021-06-17 03:37:56 (7424): Removing virtual ISO 9660 disk from VirtualBox. Hypervisor System Log: 00:00:00.125614 Loading settings file "C:\Users\User\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:00.129742 usbLibGetDevices: Starting USB device enumeration 00:00:00.155855 usbLibGetDevices: Found 3 USB devices, 0 captured 00:00:00.307464 HostDnsMonitor: initializing 00:00:00.315142 HostDnsMonitor: updating information 00:00:00.315175 HostDnsMonitor: old information 00:00:00.315176 no server entries 00:00:00.315177 no domain set 00:00:00.315178 no search string entries 00:00:00.315178 HostDnsMonitor: new information 00:00:00.315179 server 1: 192.168.1.254 00:00:00.315180 server 2: 75.153.176.9 00:00:00.315180 no domain set 00:00:00.315181 no search string entries 00:00:00.400037 SUPR0QueryVTCaps -> VERR_VMX_MSR_ALL_VMX_DISABLED 00:00:00.400815 VD: VDInit finished with VINF_SUCCESS 00:00:00.402143 VirtualBox: object created 00:00:01.016780 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={Could not find a registered machine named 'boinc_d465cb8cff08ebce'}, preserve=false aResultDetail=0 00:00:01.296692 ERROR [COM]: aRC=VBOX_E_FILE_ERROR (0x80bb0004) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Could not find file for the medium 'C:\ProgramData\BOINC\slots\2\vm_image.vdi' (VERR_FILE_NOT_FOUND)}, preserve=false aResultDetail=-102 00:00:01.569574 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_d465cb8cff08ebce\boinc_d465cb8cff08ebce.vbox" with version "1.16-windows" 00:00:01.812262 Saving settings file "C:\Users\User\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:02.364976 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_d465cb8cff08ebce\boinc_d465cb8cff08ebce.vbox" with version "1.16-windows" 00:00:02.906670 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_d465cb8cff08ebce\boinc_d465cb8cff08ebce.vbox" with version "1.16-windows" 00:00:03.163247 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_d465cb8cff08ebce\boinc_d465cb8cff08ebce.vbox" with version "1.16-windows" 00:00:03.438381 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_d465cb8cff08ebce\boinc_d465cb8cff08ebce.vbox" with version "1.16-windows" 00:00:03.708078 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_d465cb8cff08ebce\boinc_d465cb8cff08ebce.vbox" with version "1.16-windows" 00:00:03.972750 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_d465cb8cff08ebce\boinc_d465cb8cff08ebce.vbox" with version "1.16-windows" 00:00:04.235420 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_d465cb8cff08ebce\boinc_d465cb8cff08ebce.vbox" with version "1.16-windows" 00:00:04.517886 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_d465cb8cff08ebce\boinc_d465cb8cff08ebce.vbox" with version "1.16-windows" 00:00:04.786886 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_d465cb8cff08ebce\boinc_d465cb8cff08ebce.vbox" with version "1.16-windows" 00:00:05.059125 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_d465cb8cff08ebce\boinc_d465cb8cff08ebce.vbox" with version "1.16-windows" 00:00:05.321958 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_d465cb8cff08ebce\boinc_d465cb8cff08ebce.vbox" with version "1.16-windows" 00:00:05.591602 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_d465cb8cff08ebce\boinc_d465cb8cff08ebce.vbox" with version "1.16-windows" 00:00:05.859157 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_d465cb8cff08ebce\boinc_d465cb8cff08ebce.vbox" with version "1.16-windows" 00:00:06.133185 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_d465cb8cff08ebce\boinc_d465cb8cff08ebce.vbox" with version "1.16-windows" 00:00:06.388555 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:06.393706 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:06.393899 Saving settings file "C:\Users\User\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:06.498655 Saving settings file "C:\Users\User\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:06.541641 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_d465cb8cff08ebce\boinc_d465cb8cff08ebce.vbox" with version "1.16-windows" 00:00:06.664992 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:06.667215 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:06.667448 Saving settings file "C:\Users\User\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:06.682971 Saving settings file "C:\Users\User\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:06.694739 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_d465cb8cff08ebce\boinc_d465cb8cff08ebce.vbox" with version "1.16-windows" 00:00:06.930818 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_d465cb8cff08ebce\boinc_d465cb8cff08ebce.vbox" with version "1.16-windows" 00:00:07.196439 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_d465cb8cff08ebce\boinc_d465cb8cff08ebce.vbox" with version "1.16-windows" 00:00:07.466479 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.466638 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.475843 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:07.743621 Launched VM: 70191408 pid: 2524 (0x9dc) frontend: headless name: boinc_d465cb8cff08ebce 00:00:10.753619 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_d465cb8cff08ebce\boinc_d465cb8cff08ebce.vbox" with version "1.16-windows" 00:00:10.851062 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:11.189960 Saving settings file "C:\Users\User\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:16.459486 main VirtualBox: object deletion starts 00:00:16.460113 main HostDnsMonitor: shutting down ... 00:00:16.460179 main HostDnsMonitor: shut down 00:00:16.462223 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:16.462426 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: H9 SATA Controllers: 8 Maximum SATA Port count: 30 Maximum Devices per SATA Port: 1 Maximum PIIX3 SCSI Controllers: 1 Maximum ICH9 SCSI Controllers: 8 Maximum SCSI Port count: 16 Maximum Devices per SCSI Port: 1 Maximum SAS PIIX3 Controllers: 1 Maximum SAS ICH9 Controllers: 8 Maximum SAS Port count: 255 Maximum Devices per SAS Port: 1 Maximum NVMe PIIX3 Controllers: 1 Maximum NVMe ICH9 Controllers: 8 Maximum NVMe Port count: 255 Maximum Devices per NVMe Port: 1 Maximum virtio-scsi PIIX3 Controllers: 1 Maximum virtio-scsi ICH9 Controllers: 8 Maximum virtio-scsi Port count: 256 Maximum Devices per virtio-scsi Port: 1 Maximum PIIX3 Floppy Controllers:1 Maximum ICH9 Floppy Controllers: 1 Maximum Floppy Port count: 1 Maximum Devices per Floppy Port: 2 Default machine folder: C:\Users\User\VirtualBox VMs Raw-mode Supported: no Exclusive HW virtualization use: off Default hard disk format: VDI VRDE auth library: VBoxAuth Webservice auth. library: VBoxAuth Remote desktop ExtPack: Log history count: 3 Default frontend: Default audio driver: DirectSound Autostart database path: Default Guest Additions ISO: C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso Logging Level: all Proxy Mode: System Proxy URL: 2021-06-17 03:37:46 (7424): Command: VBoxManage -q list hostinfo Exit Code: 0 Output: Host Information: Host time: 2021-06-17T10:37:46.241000000Z Processor online count: 4 Processor count: 4 Processor online core count: 4 Processor core count: 4 Processor supports HW virtualization: no Processor supports PAE: yes Processor supports long mode: yes Processor supports nested paging: no Processor supports unrestricted guest: no Processor supports nested HW virtualization: no Processor#0 speed: unknown Processor#0 description: Intel(R) Core(TM) i5-3550 CPU @ 3.30GHz Processor#1 speed: unknown Processor#1 description: Intel(R) Core(TM) i5-3550 CPU @ 3.30GHz Processor#2 speed: unknown Processor#2 description: Intel(R) Core(TM) i5-3550 CPU @ 3.30GHz Processor#3 speed: unknown Processor#3 description: Intel(R) Core(TM) i5-3550 CPU @ 3.30GHz Memory size: 16179 MByte Memory available: 9746 MByte Operating system: Windows 10 Operating system version: 10.0.19041 2021-06-17 03:37:46 (7424): Command: VBoxManage -q showvminfo "boinc_d465cb8cff08ebce" --machinereadable Exit Code: -2135228415 Output: VBoxManage.exe: error: Could not find a registered machine named 'boinc_d465cb8cff08ebce' VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2715 of file VBoxManageInfo.cpp 2021-06-17 03:37:47 (7424): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\2/vm_image.vdi" Exit Code: -2135228412 Output: VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\2\vm_image.vdi' (VERR_FILE_NOT_FOUND) VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp 2021-06-17 03:37:47 (7424): Command: VBoxManage -q createvm --name "boinc_d465cb8cff08ebce" --basefolder "C:\ProgramData\BOINC\slots\2" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_d465cb8cff08ebce' is created and registered. UUID: 0a031f2d-ddb5-4229-bf5d-4f1246066264 Settings file: 'C:\ProgramData\BOINC\slots\2\boinc_d465cb8cff08ebce\boinc_d465cb8cff08ebce.vbox' 2021-06-17 03:37:48 (7424): Command: VBoxManage -q modifyvm "boinc_d465cb8cff08ebce" --description "08368976_40_2" Exit Code: 0 Output: 2021-06-17 03:37:48 (7424): Command: VBoxManage -q modifyvm "boinc_d465cb8cff08ebce" --memory 3072 Exit Code: 0 Output: 2021-06-17 03:37:48 (7424): Command: VBoxManage -q modifyvm "boinc_d465cb8cff08ebce" --cpus 1 Exit Code: 0 Output: 2021-06-17 03:37:49 (7424): Command: VBoxManage -q modifyvm "boinc_d465cb8cff08ebce" --acpi on --ioapic on Exit Code: 0 Output: 2021-06-17 03:37:49 (7424): Command: VBoxManage -q modifyvm "boinc_d465cb8cff08ebce" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2021-06-17 03:37:49 (7424): Command: VBoxManage -q modifyvm "boinc_d465cb8cff08ebce" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2021-06-17 03:37:49 (7424): Command: VBoxManage -q modifyvm "boinc_d465cb8cff08ebce" --cableconnected1 on Exit Code: 0 Output: 2021-06-17 03:37:50 (7424): Command: VBoxManage -q modifyvm "boinc_d465cb8cff08ebce" --usb off Exit Code: 0 Output: 2021-06-17 03:37:50 (7424): Command: VBoxManage -q modifyvm "boinc_d465cb8cff08ebce" --uart1 off --uart2 off Exit Code: 0 Output: 2021-06-17 03:37:50 (7424): Command: VBoxManage -q modifyvm "boinc_d465cb8cff08ebce" --lpt1 off --lpt2 off Exit Code: 0 Output: 2021-06-17 03:37:51 (7424): Command: VBoxManage -q modifyvm "boinc_d465cb8cff08ebce" --audio none Exit Code: 0 Output: 2021-06-17 03:37:51 (7424): Command: VBoxManage -q modifyvm "boinc_d465cb8cff08ebce" --clipboard disabled Exit Code: 0 Output: 2021-06-17 03:37:51 (7424): Command: VBoxManage -q modifyvm "boinc_d465cb8cff08ebce" --draganddrop disabled Exit Code: 0 Output: 2021-06-17 03:37:51 (7424): Command: VBoxManage -q storagectl "boinc_d465cb8cff08ebce" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2021-06-17 03:37:52 (7424): Command: VBoxManage -q storageattach "boinc_d465cb8cff08ebce" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\ProgramData\BOINC\slots\2/vm_isocontext.iso" Exit Code: 0 Output: 2021-06-17 03:37:52 (7424): Command: VBoxManage -q storageattach "boinc_d465cb8cff08ebce" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2021-06-17 03:37:52 (7424): Command: VBoxManage -q bandwidthctl "boinc_d465cb8cff08ebce" add "boinc_d465cb8cff08ebce_net" --type network --limit 1024G Exit Code: 0 Output: 2021-06-17 03:37:52 (7424): Command: VBoxManage -q sharedfolder add "boinc_d465cb8cff08ebce" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\2/shared" Exit Code: 0 Output: 2021-06-17 03:37:56 (7424): Command: VBoxManage -q startvm "boinc_d465cb8cff08ebce" --type headless Exit Code: -2147467259 Output: Waiting for VM "boinc_d465cb8cff08ebce" to power on... VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2021-06-17 03:37:56 (7424): Command: VBoxManage -q snapshot "boinc_d465cb8cff08ebce" list Exit Code: -108 Output: This machine does not have any snapshots 2021-06-17 03:37:56 (7424): Command: VBoxManage -q bandwidthctl "boinc_d465cb8cff08ebce" remove "boinc_d465cb8cff08ebce_net" Exit Code: 0 Output: VBoxManage.exe: error: Bandwidth groups cannot be deleted while the VM is running 2021-06-17 03:37:56 (7424): Command: VBoxManage -q unregistervm "boinc_d465cb8cff08ebce" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 2021-06-17 03:37:57 (7424): Command: VBoxManage -q closemedium dvd "C:\ProgramData\BOINC\slots\2/vm_isocontext.iso" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 03:38:02 (7424): called boinc_finish(-2147467259) </stderr_txt> ]]>
©2025 COPYRIGHT 2017-2018 NCN