Name | 08370539_13_1 |
Workunit | 8198457 |
Created | 18 Jun 2021, 0:34:40 UTC |
Sent | 18 Jun 2021, 1:17:27 UTC |
Report deadline | 23 Jun 2021, 1:17:27 UTC |
Received | 18 Jun 2021, 20:01:43 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | -2147467259 (0x80004005) Unknown error code |
Computer ID | 10312 |
Run time | 22 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 2.36 GFLOPS |
Application version | boinc2docker v1.14 (vbox64_mt) windows_x86_64 |
Peak working set size | 4.22 MB |
Peak swap size | 1.75 MB |
Peak disk usage | 228.09 MB |
<core_client_version>7.16.11</core_client_version> <![CDATA[ <message> Unspecified error (0x80004005) - exit code 2147500037 (0x80004005)</message> <stderr_txt> 2021-06-18 11:51:26 (4444): Detected: vboxwrapper 26202 2021-06-18 11:51:26 (4444): Detected: BOINC client v7.16.11 2021-06-18 11:51:27 (4444): Detected: VirtualBox VboxManage Interface (Version: 6.1.12) 2021-06-18 11:51:28 (4444): Create VM. (boinc_9ca02f312e7744e5, slot#8) 2021-06-18 11:51:28 (4444): Updating drive controller type and model for desired configuration. 2021-06-18 11:51:28 (4444): Setting Memory Size for VM. (3072MB) 2021-06-18 11:51:29 (4444): Setting CPU Count for VM. (1) 2021-06-18 11:51:29 (4444): Setting Chipset Options for VM. 2021-06-18 11:51:29 (4444): Setting Boot Options for VM. 2021-06-18 11:51:29 (4444): Setting Network Configuration for NAT. 2021-06-18 11:51:30 (4444): Enabling VM Network Access. 2021-06-18 11:51:30 (4444): Disabling USB Support for VM. 2021-06-18 11:51:30 (4444): Disabling COM Port Support for VM. 2021-06-18 11:51:31 (4444): Disabling LPT Port Support for VM. 2021-06-18 11:51:31 (4444): Disabling Audio Support for VM. 2021-06-18 11:51:31 (4444): Disabling Clipboard Support for VM. 2021-06-18 11:51:31 (4444): Disabling Drag and Drop Support for VM. 2021-06-18 11:51:32 (4444): Adding storage controller(s) to VM. 2021-06-18 11:51:32 (4444): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso) 2021-06-18 11:51:32 (4444): Adding VirtualBox Guest Additions to VM. 2021-06-18 11:51:33 (4444): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2021-06-18 11:51:33 (4444): Enabling shared directory for VM. 2021-06-18 11:51:34 (4444): Starting VM using VBoxManage interface. (boinc_9ca02f312e7744e5, slot#8) 2021-06-18 11:51:38 (4444): Error in start VM for VM: -2147467259 Command: VBoxManage -q startvm "boinc_9ca02f312e7744e5" --type headless Output: Waiting for VM "boinc_9ca02f312e7744e5" to power on... VBoxManage.exe: error: The native API dll was not found (C:\WINDOWS\system32\WinHvPlatform.dll) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2021-06-18 11:51:38 (4444): VM failed to start. 2021-06-18 11:51:38 (4444): Could not start 2021-06-18 11:51:38 (4444): ERROR: VM failed to start 2021-06-18 11:51:38 (4444): Powering off VM. 2021-06-18 11:51:38 (4444): Deregistering VM. (boinc_9ca02f312e7744e5, slot#8) 2021-06-18 11:51:38 (4444): Removing network bandwidth throttle group from VM. 2021-06-18 11:51:39 (4444): Removing VM from VirtualBox. 2021-06-18 11:51:40 (4444): Removing virtual ISO 9660 disk from VirtualBox. Hypervisor System Log: 00:00:07.322980 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.322980 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:07.463606 Saving settings file "C:\ProgramData\BOINC\slots\9\boinc_331eb9743076fec2\boinc_331eb9743076fec2.vbox" with version "1.16-windows" 00:00:07.463606 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.463606 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.463606 Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_dc7126a55f0aaa88\boinc_dc7126a55f0aaa88.vbox" with version "1.16-windows" 00:00:07.588607 Launched VM: 59769648 pid: 3696 (0xe70) frontend: headless name: boinc_9ca02f312e7744e5 00:00:07.744856 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.744856 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.744856 Saving settings file "C:\Users\Ron\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:07.744856 Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_dc7126a55f0aaa88\boinc_dc7126a55f0aaa88.vbox" with version "1.16-windows" 00:00:07.854229 Saving settings file "C:\Users\Ron\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:07.901104 Saving settings file "C:\ProgramData\BOINC\slots\9\boinc_331eb9743076fec2\boinc_331eb9743076fec2.vbox" with version "1.16-windows" 00:00:08.010482 Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_dc7126a55f0aaa88\boinc_dc7126a55f0aaa88.vbox" with version "1.16-windows" 00:00:08.260481 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.260481 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.276107 Saving settings file "C:\ProgramData\BOINC\slots\9\boinc_331eb9743076fec2\boinc_331eb9743076fec2.vbox" with version "1.16-windows" 00:00:08.276107 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.276107 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:08.276107 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:08.526107 Saving settings file "C:\ProgramData\BOINC\slots\9\boinc_331eb9743076fec2\boinc_331eb9743076fec2.vbox" with version "1.16-windows" 00:00:08.557357 Launched VM: 59553728 pid: 1316 (0x524) frontend: headless name: boinc_dc7126a55f0aaa88 00:00:08.791731 Saving settings file "C:\ProgramData\BOINC\slots\9\boinc_331eb9743076fec2\boinc_331eb9743076fec2.vbox" with version "1.16-windows" 00:00:09.057357 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.057357 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.072983 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:09.322982 Launched VM: 59619376 pid: 1320 (0x528) frontend: headless name: boinc_331eb9743076fec2 00:00:11.678029 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_9ca02f312e7744e5\boinc_9ca02f312e7744e5.vbox" with version "1.16-windows" 00:00:11.778610 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:12.119416 ERROR [COM]: aRC=VBOX_E_INVALID_OBJECT_STATE (0x80bb0007) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={Cannot unregister the machine 'boinc_9ca02f312e7744e5' while it is locked}, preserve=false aResultDetail=0 00:00:12.366475 Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_dc7126a55f0aaa88\boinc_dc7126a55f0aaa88.vbox" with version "1.16-windows" 00:00:12.469986 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:12.548107 Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_dc7126a55f0aaa88\boinc_dc7126a55f0aaa88.vbox" with version "1.16-windows" 00:00:12.809815 Saving settings file "C:\Users\Ron\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:13.163314 Saving settings file "C:\ProgramData\BOINC\slots\9\boinc_331eb9743076fec2\boinc_331eb9743076fec2.vbox" with version "1.16-windows" 00:00:13.247416 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:13.325541 Saving settings file "C:\ProgramData\BOINC\slots\9\boinc_331eb9743076fec2\boinc_331eb9743076fec2.vbox" with version "1.16-windows" 00:00:13.372415 Saving settings file "C:\Users\Ron\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:13.591166 Saving settings file "C:\Users\Ron\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:18.872419 main VirtualBox: object deletion starts 00:00:18.872419 main HostDnsMonitor: shutting down ... 00:00:18.872419 main HostDnsMonitor: shut down 00:00:18.872419 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:18.872419 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: i ICH9 Controllers: 8 Maximum virtio-scsi Port count: 256 Maximum Devices per virtio-scsi Port: 1 Maximum PIIX3 Floppy Controllers:1 Maximum ICH9 Floppy Controllers: 1 Maximum Floppy Port count: 1 Maximum Devices per Floppy Port: 2 Default machine folder: C:\Users\Ron\VirtualBox VMs Raw-mode Supported: no Exclusive HW virtualization use: off Default hard disk format: VDI VRDE auth library: VBoxAuth Webservice auth. library: VBoxAuth Remote desktop ExtPack: Log history count: 3 Default frontend: Default audio driver: DirectSound Autostart database path: Default Guest Additions ISO: C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso Logging Level: all Proxy Mode: System Proxy URL: 2021-06-18 11:51:27 (4444): Command: VBoxManage -q list hostinfo Exit Code: 0 Output: Host Information: Host time: 2021-06-18T16:51:27.599000000Z Processor online count: 4 Processor count: 4 Processor online core count: 4 Processor core count: 4 Processor supports HW virtualization: no Processor supports PAE: yes Processor supports long mode: yes Processor supports nested paging: no Processor supports unrestricted guest: no Processor supports nested HW virtualization: no Processor#0 speed: unknown Processor#0 description: Intel(R) Xeon(R) CPU E5405 @ 2.00GHz Processor#1 speed: unknown Processor#1 description: Intel(R) Xeon(R) CPU E5405 @ 2.00GHz Processor#2 speed: unknown Processor#2 description: Intel(R) Xeon(R) CPU E5405 @ 2.00GHz Processor#3 speed: unknown Processor#3 description: Intel(R) Xeon(R) CPU E5405 @ 2.00GHz Memory size: 8186 MByte Memory available: 5915 MByte Operating system: Windows 8.1 Operating system version: 6.3.9600 2021-06-18 11:51:28 (4444): Command: VBoxManage -q showvminfo "boinc_9ca02f312e7744e5" --machinereadable Exit Code: -2135228415 Output: VBoxManage.exe: error: Could not find a registered machine named 'boinc_9ca02f312e7744e5' VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2715 of file VBoxManageInfo.cpp 2021-06-18 11:51:28 (4444): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\8/vm_image.vdi" Exit Code: -2135228412 Output: VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\8\vm_image.vdi' (VERR_FILE_NOT_FOUND) VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp 2021-06-18 11:51:28 (4444): Command: VBoxManage -q createvm --name "boinc_9ca02f312e7744e5" --basefolder "C:\ProgramData\BOINC\slots\8" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_9ca02f312e7744e5' is created and registered. UUID: 68d43b8e-3ed6-4a44-a46b-65e96708df43 Settings file: 'C:\ProgramData\BOINC\slots\8\boinc_9ca02f312e7744e5\boinc_9ca02f312e7744e5.vbox' 2021-06-18 11:51:28 (4444): Command: VBoxManage -q modifyvm "boinc_9ca02f312e7744e5" --description "08370539_13_1" Exit Code: 0 Output: 2021-06-18 11:51:29 (4444): Command: VBoxManage -q modifyvm "boinc_9ca02f312e7744e5" --memory 3072 Exit Code: 0 Output: 2021-06-18 11:51:29 (4444): Command: VBoxManage -q modifyvm "boinc_9ca02f312e7744e5" --cpus 1 Exit Code: 0 Output: 2021-06-18 11:51:29 (4444): Command: VBoxManage -q modifyvm "boinc_9ca02f312e7744e5" --acpi on --ioapic on Exit Code: 0 Output: 2021-06-18 11:51:29 (4444): Command: VBoxManage -q modifyvm "boinc_9ca02f312e7744e5" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2021-06-18 11:51:30 (4444): Command: VBoxManage -q modifyvm "boinc_9ca02f312e7744e5" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2021-06-18 11:51:30 (4444): Command: VBoxManage -q modifyvm "boinc_9ca02f312e7744e5" --cableconnected1 on Exit Code: 0 Output: 2021-06-18 11:51:30 (4444): Command: VBoxManage -q modifyvm "boinc_9ca02f312e7744e5" --usb off Exit Code: 0 Output: 2021-06-18 11:51:31 (4444): Command: VBoxManage -q modifyvm "boinc_9ca02f312e7744e5" --uart1 off --uart2 off Exit Code: 0 Output: 2021-06-18 11:51:31 (4444): Command: VBoxManage -q modifyvm "boinc_9ca02f312e7744e5" --lpt1 off --lpt2 off Exit Code: 0 Output: 2021-06-18 11:51:31 (4444): Command: VBoxManage -q modifyvm "boinc_9ca02f312e7744e5" --audio none Exit Code: 0 Output: 2021-06-18 11:51:31 (4444): Command: VBoxManage -q modifyvm "boinc_9ca02f312e7744e5" --clipboard disabled Exit Code: 0 Output: 2021-06-18 11:51:32 (4444): Command: VBoxManage -q modifyvm "boinc_9ca02f312e7744e5" --draganddrop disabled Exit Code: 0 Output: 2021-06-18 11:51:32 (4444): Command: VBoxManage -q storagectl "boinc_9ca02f312e7744e5" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2021-06-18 11:51:32 (4444): Command: VBoxManage -q storageattach "boinc_9ca02f312e7744e5" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\ProgramData\BOINC\slots\8/vm_isocontext.iso" Exit Code: 0 Output: 2021-06-18 11:51:33 (4444): Command: VBoxManage -q storageattach "boinc_9ca02f312e7744e5" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2021-06-18 11:51:33 (4444): Command: VBoxManage -q bandwidthctl "boinc_9ca02f312e7744e5" add "boinc_9ca02f312e7744e5_net" --type network --limit 1024G Exit Code: 0 Output: 2021-06-18 11:51:34 (4444): Command: VBoxManage -q sharedfolder add "boinc_9ca02f312e7744e5" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\8/shared" Exit Code: 0 Output: 2021-06-18 11:51:38 (4444): Command: VBoxManage -q startvm "boinc_9ca02f312e7744e5" --type headless Exit Code: -2147467259 Output: Waiting for VM "boinc_9ca02f312e7744e5" to power on... VBoxManage.exe: error: The native API dll was not found (C:\WINDOWS\system32\WinHvPlatform.dll) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2021-06-18 11:51:38 (4444): Command: VBoxManage -q snapshot "boinc_9ca02f312e7744e5" list Exit Code: -108 Output: This machine does not have any snapshots 2021-06-18 11:51:39 (4444): Command: VBoxManage -q bandwidthctl "boinc_9ca02f312e7744e5" remove "boinc_9ca02f312e7744e5_net" Exit Code: 0 Output: VBoxManage.exe: error: Bandwidth groups cannot be deleted while the VM is running 2021-06-18 11:51:39 (4444): Command: VBoxManage -q unregistervm "boinc_9ca02f312e7744e5" --delete Exit Code: -2135228409 Output: VBoxManage.exe: error: Cannot unregister the machine 'boinc_9ca02f312e7744e5' while it is locked VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component MachineWrap, interface IMachine, callee IUnknown VBoxManage.exe: error: Context: "Unregister(CleanupMode_DetachAllReturnHardDisksOnly, ComSafeArrayAsOutParam(aMedia))" at line 154 of file VBoxManageMisc.cpp 2021-06-18 11:51:40 (4444): Command: VBoxManage -q unregistervm "boinc_9ca02f312e7744e5" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 2021-06-18 11:51:40 (4444): Command: VBoxManage -q closemedium dvd "C:\ProgramData\BOINC\slots\8/vm_isocontext.iso" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 11:51:47 (4444): called boinc_finish(-2147467259) </stderr_txt> ]]>
©2025 COPYRIGHT 2017-2018 NCN