Name | 08374700_35_2 |
Workunit | 8278903 |
Created | 20 Jun 2021, 19:58:53 UTC |
Sent | 20 Jun 2021, 19:59:12 UTC |
Report deadline | 25 Jun 2021, 19:59:12 UTC |
Received | 21 Jun 2021, 20:06:25 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | -2147467259 (0x80004005) Unknown error code |
Computer ID | 11542 |
Run time | 18 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 4.93 GFLOPS |
Application version | boinc2docker v1.14 (vbox64_mt) windows_x86_64 |
Peak working set size | 10.36 MB |
Peak swap size | 6.21 MB |
Peak disk usage | 273.87 MB |
<core_client_version>7.16.11</core_client_version> <![CDATA[ <message> Unspecified error (0x80004005) - exit code 2147500037 (0x80004005)</message> <stderr_txt> 2021-06-20 16:02:47 (10988): Detected: vboxwrapper 26202 2021-06-20 16:02:47 (10988): Detected: BOINC client v7.16.11 2021-06-20 16:02:47 (10988): Detected: VirtualBox VboxManage Interface (Version: 6.1.12) 2021-06-20 16:02:48 (10988): Create VM. (boinc_b28cea82901b9104, slot#4) 2021-06-20 16:02:48 (10988): Updating drive controller type and model for desired configuration. 2021-06-20 16:02:49 (10988): Setting Memory Size for VM. (3072MB) 2021-06-20 16:02:49 (10988): Setting CPU Count for VM. (1) 2021-06-20 16:02:49 (10988): Setting Chipset Options for VM. 2021-06-20 16:02:49 (10988): Setting Boot Options for VM. 2021-06-20 16:02:50 (10988): Setting Network Configuration for NAT. 2021-06-20 16:02:50 (10988): Enabling VM Network Access. 2021-06-20 16:02:50 (10988): Disabling USB Support for VM. 2021-06-20 16:02:50 (10988): Disabling COM Port Support for VM. 2021-06-20 16:02:51 (10988): Disabling LPT Port Support for VM. 2021-06-20 16:02:51 (10988): Disabling Audio Support for VM. 2021-06-20 16:02:51 (10988): Disabling Clipboard Support for VM. 2021-06-20 16:02:51 (10988): Disabling Drag and Drop Support for VM. 2021-06-20 16:02:52 (10988): Adding storage controller(s) to VM. 2021-06-20 16:02:52 (10988): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso) 2021-06-20 16:02:52 (10988): Adding VirtualBox Guest Additions to VM. 2021-06-20 16:02:53 (10988): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2021-06-20 16:02:53 (10988): Enabling shared directory for VM. 2021-06-20 16:02:53 (10988): Starting VM using VBoxManage interface. (boinc_b28cea82901b9104, slot#4) 2021-06-20 16:02:55 (10988): Error in start VM for VM: -2147467259 Command: VBoxManage -q startvm "boinc_b28cea82901b9104" --type headless Output: Waiting for VM "boinc_b28cea82901b9104" to power on... VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: AMD-V is disabled in the BIOS (or by the host OS) (VERR_SVM_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2021-06-20 16:02:55 (10988): VM failed to start. 2021-06-20 16:02:55 (10988): Could not start 2021-06-20 16:02:55 (10988): ERROR: VM failed to start 2021-06-20 16:02:55 (10988): Powering off VM. 2021-06-20 16:02:55 (10988): Deregistering VM. (boinc_b28cea82901b9104, slot#4) 2021-06-20 16:02:55 (10988): Removing network bandwidth throttle group from VM. 2021-06-20 16:02:55 (10988): Removing VM from VirtualBox. 2021-06-20 16:02:56 (10988): Removing virtual ISO 9660 disk from VirtualBox. Hypervisor System Log: 00:00:07.213676 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.219433 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:07.271460 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_df3a46f3f844c52e\boinc_df3a46f3f844c52e.vbox" with version "1.16-windows" 00:00:07.320773 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_db86dcd3e43dc25b\boinc_db86dcd3e43dc25b.vbox" with version "1.16-windows" 00:00:07.451339 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.451453 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.458648 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:07.465694 Launched VM: 62111920 pid: 3676 (0xe5c) frontend: headless name: boinc_da6544f25c7e2286 00:00:07.527228 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_df3a46f3f844c52e\boinc_df3a46f3f844c52e.vbox" with version "1.16-windows" 00:00:07.579057 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.579170 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.585461 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:07.699224 Launched VM: 61110496 pid: 18080 (0x46a0) frontend: headless name: boinc_d43c4eb6b4b3f331 00:00:07.784841 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.784970 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:07.791034 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:07.829129 Launched VM: 61524416 pid: 9332 (0x2474) frontend: headless name: boinc_db86dcd3e43dc25b 00:00:08.033843 Launched VM: 62088560 pid: 11744 (0x2de0) frontend: headless name: boinc_df3a46f3f844c52e 00:00:08.152506 Saving settings file "C:\ProgramData\BOINC\slots\6\boinc_b8d1c7b714a8377a\boinc_b8d1c7b714a8377a.vbox" with version "1.16-windows" 00:00:08.195261 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:08.231453 Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_b28cea82901b9104\boinc_b28cea82901b9104.vbox" with version "1.16-windows" 00:00:08.277580 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:08.349837 Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_c972c251da86554b\boinc_c972c251da86554b.vbox" with version "1.16-windows" 00:00:08.386656 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:08.485910 Saving settings file "C:\Users\tanne\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:08.558104 Saving settings file "C:\Users\tanne\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:08.664621 Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_d1d1af1ced613053\boinc_d1d1af1ced613053.vbox" with version "1.16-windows" 00:00:08.670323 Saving settings file "C:\Users\tanne\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:08.702687 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:08.987111 Saving settings file "C:\Users\tanne\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:09.268597 Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_da6544f25c7e2286\boinc_da6544f25c7e2286.vbox" with version "1.16-windows" 00:00:09.306446 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:09.455372 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_d43c4eb6b4b3f331\boinc_d43c4eb6b4b3f331.vbox" with version "1.16-windows" 00:00:09.493011 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:09.586865 Saving settings file "C:\Users\tanne\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:09.623525 Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_db86dcd3e43dc25b\boinc_db86dcd3e43dc25b.vbox" with version "1.16-windows" 00:00:09.658248 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:09.755228 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_df3a46f3f844c52e\boinc_df3a46f3f844c52e.vbox" with version "1.16-windows" 00:00:09.772311 Saving settings file "C:\Users\tanne\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:09.790996 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:09.937265 Saving settings file "C:\Users\tanne\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:10.071000 Saving settings file "C:\Users\tanne\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:15.337649 main VirtualBox: object deletion starts 00:00:15.338053 main HostDnsMonitor: shutting down ... 00:00:15.338073 main HostDnsMonitor: shut down 00:00:15.338866 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:15.338974 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: 255 Maximum Devices per SAS Port: 1 Maximum NVMe PIIX3 Controllers: 1 Maximum NVMe ICH9 Controllers: 8 Maximum NVMe Port count: 255 Maximum Devices per NVMe Port: 1 Maximum virtio-scsi PIIX3 Controllers: 1 Maximum virtio-scsi ICH9 Controllers: 8 Maximum virtio-scsi Port count: 256 Maximum Devices per virtio-scsi Port: 1 Maximum PIIX3 Floppy Controllers:1 Maximum ICH9 Floppy Controllers: 1 Maximum Floppy Port count: 1 Maximum Devices per Floppy Port: 2 Default machine folder: C:\Users\tanne\VirtualBox VMs Raw-mode Supported: no Exclusive HW virtualization use: off Default hard disk format: VDI VRDE auth library: VBoxAuth Webservice auth. library: VBoxAuth Remote desktop ExtPack: Log history count: 3 Default frontend: Default audio driver: DirectSound Autostart database path: Default Guest Additions ISO: C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso Logging Level: all Proxy Mode: System Proxy URL: 2021-06-20 16:02:48 (10988): Command: VBoxManage -q list hostinfo Exit Code: 0 Output: Host Information: Host time: 2021-06-20T20:02:47.848000000Z Processor online count: 8 Processor count: 8 Processor online core count: 4 Processor core count: 4 Processor supports HW virtualization: no Processor supports PAE: yes Processor supports long mode: yes Processor supports nested paging: no Processor supports unrestricted guest: no Processor supports nested HW virtualization: no Processor#0 speed: unknown Processor#0 description: AMD Ryzen 3 3100 4-Core Processor Processor#1 speed: unknown Processor#1 description: AMD Ryzen 3 3100 4-Core Processor Processor#2 speed: unknown Processor#2 description: AMD Ryzen 3 3100 4-Core Processor Processor#3 speed: unknown Processor#3 description: AMD Ryzen 3 3100 4-Core Processor Processor#4 speed: unknown Processor#4 description: AMD Ryzen 3 3100 4-Core Processor Processor#5 speed: unknown Processor#5 description: AMD Ryzen 3 3100 4-Core Processor Processor#6 speed: unknown Processor#6 description: AMD Ryzen 3 3100 4-Core Processor Processor#7 speed: unknown Processor#7 description: AMD Ryzen 3 3100 4-Core Processor Memory size: 32716 MByte Memory available: 25468 MByte Operating system: Windows 10 Operating system version: 10.0.19042 2021-06-20 16:02:48 (10988): Command: VBoxManage -q showvminfo "boinc_b28cea82901b9104" --machinereadable Exit Code: -2135228415 Output: VBoxManage.exe: error: Could not find a registered machine named 'boinc_b28cea82901b9104' VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2715 of file VBoxManageInfo.cpp 2021-06-20 16:02:48 (10988): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\4/vm_image.vdi" Exit Code: -2135228412 Output: VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\4\vm_image.vdi' (VERR_FILE_NOT_FOUND) VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp 2021-06-20 16:02:48 (10988): Command: VBoxManage -q createvm --name "boinc_b28cea82901b9104" --basefolder "C:\ProgramData\BOINC\slots\4" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_b28cea82901b9104' is created and registered. UUID: 5884c615-4d2f-4022-8cb9-fa234f0d6de8 Settings file: 'C:\ProgramData\BOINC\slots\4\boinc_b28cea82901b9104\boinc_b28cea82901b9104.vbox' 2021-06-20 16:02:49 (10988): Command: VBoxManage -q modifyvm "boinc_b28cea82901b9104" --description "08374700_35_2" Exit Code: 0 Output: 2021-06-20 16:02:49 (10988): Command: VBoxManage -q modifyvm "boinc_b28cea82901b9104" --memory 3072 Exit Code: 0 Output: 2021-06-20 16:02:49 (10988): Command: VBoxManage -q modifyvm "boinc_b28cea82901b9104" --cpus 1 Exit Code: 0 Output: 2021-06-20 16:02:49 (10988): Command: VBoxManage -q modifyvm "boinc_b28cea82901b9104" --acpi on --ioapic on Exit Code: 0 Output: 2021-06-20 16:02:50 (10988): Command: VBoxManage -q modifyvm "boinc_b28cea82901b9104" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2021-06-20 16:02:50 (10988): Command: VBoxManage -q modifyvm "boinc_b28cea82901b9104" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2021-06-20 16:02:50 (10988): Command: VBoxManage -q modifyvm "boinc_b28cea82901b9104" --cableconnected1 on Exit Code: 0 Output: 2021-06-20 16:02:50 (10988): Command: VBoxManage -q modifyvm "boinc_b28cea82901b9104" --usb off Exit Code: 0 Output: 2021-06-20 16:02:51 (10988): Command: VBoxManage -q modifyvm "boinc_b28cea82901b9104" --uart1 off --uart2 off Exit Code: 0 Output: 2021-06-20 16:02:51 (10988): Command: VBoxManage -q modifyvm "boinc_b28cea82901b9104" --lpt1 off --lpt2 off Exit Code: 0 Output: 2021-06-20 16:02:51 (10988): Command: VBoxManage -q modifyvm "boinc_b28cea82901b9104" --audio none Exit Code: 0 Output: 2021-06-20 16:02:51 (10988): Command: VBoxManage -q modifyvm "boinc_b28cea82901b9104" --clipboard disabled Exit Code: 0 Output: 2021-06-20 16:02:52 (10988): Command: VBoxManage -q modifyvm "boinc_b28cea82901b9104" --draganddrop disabled Exit Code: 0 Output: 2021-06-20 16:02:52 (10988): Command: VBoxManage -q storagectl "boinc_b28cea82901b9104" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2021-06-20 16:02:52 (10988): Command: VBoxManage -q storageattach "boinc_b28cea82901b9104" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\ProgramData\BOINC\slots\4/vm_isocontext.iso" Exit Code: 0 Output: 2021-06-20 16:02:53 (10988): Command: VBoxManage -q storageattach "boinc_b28cea82901b9104" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2021-06-20 16:02:53 (10988): Command: VBoxManage -q bandwidthctl "boinc_b28cea82901b9104" add "boinc_b28cea82901b9104_net" --type network --limit 1024G Exit Code: 0 Output: 2021-06-20 16:02:53 (10988): Command: VBoxManage -q sharedfolder add "boinc_b28cea82901b9104" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\4/shared" Exit Code: 0 Output: 2021-06-20 16:02:55 (10988): Command: VBoxManage -q startvm "boinc_b28cea82901b9104" --type headless Exit Code: -2147467259 Output: Waiting for VM "boinc_b28cea82901b9104" to power on... VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: AMD-V is disabled in the BIOS (or by the host OS) (VERR_SVM_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2021-06-20 16:02:55 (10988): Command: VBoxManage -q snapshot "boinc_b28cea82901b9104" list Exit Code: -108 Output: This machine does not have any snapshots 2021-06-20 16:02:55 (10988): Command: VBoxManage -q bandwidthctl "boinc_b28cea82901b9104" remove "boinc_b28cea82901b9104_net" Exit Code: 0 Output: VBoxManage.exe: error: Bandwidth groups cannot be deleted while the VM is running 2021-06-20 16:02:56 (10988): Command: VBoxManage -q unregistervm "boinc_b28cea82901b9104" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 2021-06-20 16:02:56 (10988): Command: VBoxManage -q closemedium dvd "C:\ProgramData\BOINC\slots\4/vm_isocontext.iso" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 16:03:03 (10988): called boinc_finish(-2147467259) </stderr_txt> ]]>
©2025 COPYRIGHT 2017-2018 NCN