Task 10725593

Name 08383889_24_0
Workunit 8344616
Created 25 Jun 2021, 4:03:26 UTC
Sent 25 Jun 2021, 10:08:17 UTC
Report deadline 30 Jun 2021, 10:08:17 UTC
Received 26 Jun 2021, 0:59:03 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status -2147467259 (0x80004005) Unknown error code
Computer ID 11542
Run time 8 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 4.93 GFLOPS
Application version boinc2docker v1.14 (vbox64_mt)
windows_x86_64
Peak working set size 10.90 MB
Peak swap size 6.24 MB
Peak disk usage 228.49 MB

Stderr output

<core_client_version>7.16.11</core_client_version>
<![CDATA[
<message>
Unspecified error
 (0x80004005) - exit code 2147500037 (0x80004005)</message>
<stderr_txt>
2021-06-25 06:08:45 (7512): Detected: vboxwrapper 26202
2021-06-25 06:08:45 (7512): Detected: BOINC client v7.16.11
2021-06-25 06:08:45 (7512): Detected: VirtualBox VboxManage Interface (Version: 6.1.12)
2021-06-25 06:08:46 (7512): Create VM. (boinc_2b7c384214a4a01b, slot#10)
2021-06-25 06:08:46 (7512): Updating drive controller type and model for desired configuration.
2021-06-25 06:08:47 (7512): Setting Memory Size for VM. (3072MB)
2021-06-25 06:08:47 (7512): Setting CPU Count for VM. (1)
2021-06-25 06:08:47 (7512): Setting Chipset Options for VM.
2021-06-25 06:08:47 (7512): Setting Boot Options for VM.
2021-06-25 06:08:48 (7512): Setting Network Configuration for NAT.
2021-06-25 06:08:48 (7512): Enabling VM Network Access.
2021-06-25 06:08:48 (7512): Disabling USB Support for VM.
2021-06-25 06:08:48 (7512): Disabling COM Port Support for VM.
2021-06-25 06:08:49 (7512): Disabling LPT Port Support for VM.
2021-06-25 06:08:49 (7512): Disabling Audio Support for VM.
2021-06-25 06:08:49 (7512): Disabling Clipboard Support for VM.
2021-06-25 06:08:49 (7512): Disabling Drag and Drop Support for VM.
2021-06-25 06:08:50 (7512): Adding storage controller(s) to VM.
2021-06-25 06:08:50 (7512): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso)
2021-06-25 06:08:50 (7512): Adding VirtualBox Guest Additions to VM.
2021-06-25 06:08:50 (7512): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2021-06-25 06:08:51 (7512): Enabling shared directory for VM.
2021-06-25 06:08:51 (7512): Starting VM using VBoxManage interface. (boinc_2b7c384214a4a01b, slot#10)
2021-06-25 06:08:53 (7512): Error in start VM for VM: -2147467259
Command:
VBoxManage -q startvm "boinc_2b7c384214a4a01b" --type headless
Output:
Waiting for VM "boinc_2b7c384214a4a01b" to power on...
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: AMD-V is disabled in the BIOS (or by the host OS) (VERR_SVM_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole

2021-06-25 06:08:53 (7512): VM failed to start.
2021-06-25 06:08:53 (7512): Could not start 
2021-06-25 06:08:53 (7512): ERROR: VM failed to start
2021-06-25 06:08:53 (7512): Powering off VM.
2021-06-25 06:08:53 (7512): Deregistering VM. (boinc_2b7c384214a4a01b, slot#10)
2021-06-25 06:08:53 (7512): Removing network bandwidth throttle group from VM.
2021-06-25 06:08:54 (7512): Removing VM from VirtualBox.
2021-06-25 06:08:54 (7512): Removing virtual ISO 9660 disk from VirtualBox.

    Hypervisor System Log:

00:00:07.449571          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:07.508317          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.508466          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.515947          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:07.542408          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.542529          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.548891          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:07.583796          Saving settings file "C:\ProgramData\BOINC\slots\6\boinc_105c59fd15dbc951\boinc_105c59fd15dbc951.vbox" with version "1.16-windows"
00:00:07.619186          Saving settings file "C:\ProgramData\BOINC\slots\18\boinc_4cf744513371c454\boinc_4cf744513371c454.vbox" with version "1.16-windows"
00:00:07.695550          Launched VM: 68091856 pid: 6336 (0x18c0) frontend: headless name: boinc_2b7c384214a4a01b
00:00:07.758290          Launched VM: 67724304 pid: 8184 (0x1ff8) frontend: headless name: boinc_2b98b97550c2454f
00:00:07.794424          Launched VM: 68019744 pid: 18636 (0x48cc) frontend: headless name: boinc_4ffd2e334434a538
00:00:07.841374          Saving settings file "C:\ProgramData\BOINC\slots\6\boinc_105c59fd15dbc951\boinc_105c59fd15dbc951.vbox" with version "1.16-windows"
00:00:07.874936          Saving settings file "C:\ProgramData\BOINC\slots\18\boinc_4cf744513371c454\boinc_4cf744513371c454.vbox" with version "1.16-windows"
00:00:08.096207          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.096337          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.103412          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:08.130710          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.130825          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.137655          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:08.321976          Saving settings file "C:\ProgramData\BOINC\slots\9\boinc_0455d5b4cba58ffc\boinc_0455d5b4cba58ffc.vbox" with version "1.16-windows"
00:00:08.343440          Launched VM: 68021648 pid: 20348 (0x4f7c) frontend: headless name: boinc_105c59fd15dbc951
00:00:08.366763          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:08.381117          Launched VM: 67941280 pid: 6772 (0x1a74) frontend: headless name: boinc_4cf744513371c454
00:00:08.662814          Saving settings file "C:\Users\tanne\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:09.694014          Saving settings file "C:\ProgramData\BOINC\slots\10\boinc_2b7c384214a4a01b\boinc_2b7c384214a4a01b.vbox" with version "1.16-windows"
00:00:09.742844          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:09.771459          Saving settings file "C:\ProgramData\BOINC\slots\16\boinc_2b98b97550c2454f\boinc_2b98b97550c2454f.vbox" with version "1.16-windows"
00:00:09.772100          Saving settings file "C:\ProgramData\BOINC\slots\42\boinc_4ffd2e334434a538\boinc_4ffd2e334434a538.vbox" with version "1.16-windows"
00:00:09.816982          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:09.817043          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:10.026767          Saving settings file "C:\Users\tanne\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:10.101451          Saving settings file "C:\Users\tanne\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:10.103013          Saving settings file "C:\Users\tanne\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:10.187526          Saving settings file "C:\ProgramData\BOINC\slots\6\boinc_105c59fd15dbc951\boinc_105c59fd15dbc951.vbox" with version "1.16-windows"
00:00:10.210413          Saving settings file "C:\ProgramData\BOINC\slots\18\boinc_4cf744513371c454\boinc_4cf744513371c454.vbox" with version "1.16-windows"
00:00:10.223418          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:10.246686          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:10.503891          Saving settings file "C:\Users\tanne\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:10.527027          Saving settings file "C:\Users\tanne\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:15.808607 main     VirtualBox: object deletion starts
00:00:15.809215 main     HostDnsMonitor: shutting down ...
00:00:15.809247 main     HostDnsMonitor: shut down
00:00:15.810777 Watcher  ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0
00:00:15.810996 main     VirtualBox: object deleted

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

Port count:          255
Maximum Devices per SAS Port:    1
Maximum NVMe PIIX3 Controllers:  1
Maximum NVMe ICH9 Controllers:   8
Maximum NVMe Port count:         255
Maximum Devices per NVMe Port:   1
Maximum virtio-scsi PIIX3 Controllers:  1
Maximum virtio-scsi ICH9 Controllers:   8
Maximum virtio-scsi Port count:         256
Maximum Devices per virtio-scsi Port:   1
Maximum PIIX3 Floppy Controllers:1
Maximum ICH9 Floppy Controllers: 1
Maximum Floppy Port count:       1
Maximum Devices per Floppy Port: 2
Default machine folder:          C:\Users\tanne\VirtualBox VMs
Raw-mode Supported:              no
Exclusive HW virtualization use: off
Default hard disk format:        VDI
VRDE auth library:               VBoxAuth
Webservice auth. library:        VBoxAuth
Remote desktop ExtPack:          
Log history count:               3
Default frontend:                
Default audio driver:            DirectSound
Autostart database path:         
Default Guest Additions ISO:     C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso
Logging Level:                   all
Proxy Mode:                      System
Proxy URL:                       

2021-06-25 06:08:46 (7512): 
Command: VBoxManage -q list hostinfo 
Exit Code: 0
Output:
Host Information:

Host time: 2021-06-25T10:08:45.857000000Z
Processor online count: 8
Processor count: 8
Processor online core count: 4
Processor core count: 4
Processor supports HW virtualization: no
Processor supports PAE: yes
Processor supports long mode: yes
Processor supports nested paging: no
Processor supports unrestricted guest: no
Processor supports nested HW virtualization: no
Processor#0 speed: unknown
Processor#0 description: AMD Ryzen 3 3100 4-Core Processor
Processor#1 speed: unknown
Processor#1 description: AMD Ryzen 3 3100 4-Core Processor
Processor#2 speed: unknown
Processor#2 description: AMD Ryzen 3 3100 4-Core Processor
Processor#3 speed: unknown
Processor#3 description: AMD Ryzen 3 3100 4-Core Processor
Processor#4 speed: unknown
Processor#4 description: AMD Ryzen 3 3100 4-Core Processor
Processor#5 speed: unknown
Processor#5 description: AMD Ryzen 3 3100 4-Core Processor
Processor#6 speed: unknown
Processor#6 description: AMD Ryzen 3 3100 4-Core Processor
Processor#7 speed: unknown
Processor#7 description: AMD Ryzen 3 3100 4-Core Processor
Memory size: 32716 MByte
Memory available: 21099 MByte
Operating system: Windows 10
Operating system version: 10.0.19042

2021-06-25 06:08:46 (7512): 
Command: VBoxManage -q showvminfo "boinc_2b7c384214a4a01b" --machinereadable 
Exit Code: -2135228415
Output:
VBoxManage.exe: error: Could not find a registered machine named 'boinc_2b7c384214a4a01b'
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown
VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2715 of file VBoxManageInfo.cpp

2021-06-25 06:08:46 (7512): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\10/vm_image.vdi" 
Exit Code: -2135228412
Output:
VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\10\vm_image.vdi' (VERR_FILE_NOT_FOUND)
VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp

2021-06-25 06:08:46 (7512): 
Command: VBoxManage -q createvm --name "boinc_2b7c384214a4a01b" --basefolder "C:\ProgramData\BOINC\slots\10" --ostype "Linux26_64" --register
Exit Code: 0
Output:
Virtual machine 'boinc_2b7c384214a4a01b' is created and registered.
UUID: c0c7b05b-8421-43b1-baec-c0959a88a36a
Settings file: 'C:\ProgramData\BOINC\slots\10\boinc_2b7c384214a4a01b\boinc_2b7c384214a4a01b.vbox'

2021-06-25 06:08:47 (7512): 
Command: VBoxManage -q modifyvm "boinc_2b7c384214a4a01b" --description "08383889_24_0" 
Exit Code: 0
Output:

2021-06-25 06:08:47 (7512): 
Command: VBoxManage -q modifyvm "boinc_2b7c384214a4a01b" --memory 3072 
Exit Code: 0
Output:

2021-06-25 06:08:47 (7512): 
Command: VBoxManage -q modifyvm "boinc_2b7c384214a4a01b" --cpus 1 
Exit Code: 0
Output:

2021-06-25 06:08:47 (7512): 
Command: VBoxManage -q modifyvm "boinc_2b7c384214a4a01b" --acpi on --ioapic on 
Exit Code: 0
Output:

2021-06-25 06:08:48 (7512): 
Command: VBoxManage -q modifyvm "boinc_2b7c384214a4a01b" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2021-06-25 06:08:48 (7512): 
Command: VBoxManage -q modifyvm "boinc_2b7c384214a4a01b" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2021-06-25 06:08:48 (7512): 
Command: VBoxManage -q modifyvm "boinc_2b7c384214a4a01b" --cableconnected1 on 
Exit Code: 0
Output:

2021-06-25 06:08:48 (7512): 
Command: VBoxManage -q modifyvm "boinc_2b7c384214a4a01b" --usb off 
Exit Code: 0
Output:

2021-06-25 06:08:49 (7512): 
Command: VBoxManage -q modifyvm "boinc_2b7c384214a4a01b" --uart1 off --uart2 off 
Exit Code: 0
Output:

2021-06-25 06:08:49 (7512): 
Command: VBoxManage -q modifyvm "boinc_2b7c384214a4a01b" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2021-06-25 06:08:49 (7512): 
Command: VBoxManage -q modifyvm "boinc_2b7c384214a4a01b" --audio none 
Exit Code: 0
Output:

2021-06-25 06:08:49 (7512): 
Command: VBoxManage -q modifyvm "boinc_2b7c384214a4a01b" --clipboard disabled 
Exit Code: 0
Output:

2021-06-25 06:08:50 (7512): 
Command: VBoxManage -q modifyvm "boinc_2b7c384214a4a01b" --draganddrop disabled 
Exit Code: 0
Output:

2021-06-25 06:08:50 (7512): 
Command: VBoxManage -q storagectl "boinc_2b7c384214a4a01b" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2021-06-25 06:08:50 (7512): 
Command: VBoxManage -q storageattach "boinc_2b7c384214a4a01b" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\ProgramData\BOINC\slots\10/vm_isocontext.iso" 
Exit Code: 0
Output:

2021-06-25 06:08:50 (7512): 
Command: VBoxManage -q storageattach "boinc_2b7c384214a4a01b" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2021-06-25 06:08:51 (7512): 
Command: VBoxManage -q bandwidthctl "boinc_2b7c384214a4a01b" add "boinc_2b7c384214a4a01b_net" --type network --limit 1024G 
Exit Code: 0
Output:

2021-06-25 06:08:51 (7512): 
Command: VBoxManage -q sharedfolder add "boinc_2b7c384214a4a01b" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\10/shared"
Exit Code: 0
Output:

2021-06-25 06:08:53 (7512): 
Command: VBoxManage -q startvm "boinc_2b7c384214a4a01b" --type headless
Exit Code: -2147467259
Output:
Waiting for VM "boinc_2b7c384214a4a01b" to power on...
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: AMD-V is disabled in the BIOS (or by the host OS) (VERR_SVM_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole

2021-06-25 06:08:53 (7512): 
Command: VBoxManage -q snapshot "boinc_2b7c384214a4a01b" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2021-06-25 06:08:54 (7512): 
Command: VBoxManage -q bandwidthctl "boinc_2b7c384214a4a01b" remove "boinc_2b7c384214a4a01b_net" 
Exit Code: 0
Output:
VBoxManage.exe: error: Bandwidth groups cannot be deleted while the VM is running

2021-06-25 06:08:54 (7512): 
Command: VBoxManage -q unregistervm "boinc_2b7c384214a4a01b" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

2021-06-25 06:08:54 (7512): 
Command: VBoxManage -q closemedium dvd "C:\ProgramData\BOINC\slots\10/vm_isocontext.iso" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

06:09:00 (7512): called boinc_finish(-2147467259)

</stderr_txt>
]]>


©2025 COPYRIGHT 2017-2018 NCN