Name | 08385652_084_1 |
Workunit | 8377255 |
Created | 26 Jun 2021, 21:43:27 UTC |
Sent | 26 Jun 2021, 22:10:13 UTC |
Report deadline | 1 Jul 2021, 22:10:13 UTC |
Received | 27 Jun 2021, 22:16:07 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | -2147467259 (0x80004005) Unknown error code |
Computer ID | 10672 |
Run time | 24 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 5.53 GFLOPS |
Application version | boinc2docker v1.14 (vbox64_mt) windows_x86_64 |
Peak working set size | 10.97 MB |
Peak swap size | 6.21 MB |
Peak disk usage | 501.19 MB |
<core_client_version>7.16.11</core_client_version> <![CDATA[ <message> Unspecified error (0x80004005) - exit code 2147500037 (0x80004005)</message> <stderr_txt> 2021-06-26 18:12:30 (20192): Detected: vboxwrapper 26202 2021-06-26 18:12:30 (20192): Detected: BOINC client v7.16.11 2021-06-26 18:12:30 (20192): Detected: VirtualBox VboxManage Interface (Version: 6.1.12) 2021-06-26 18:12:31 (20192): Create VM. (boinc_5d5fdf23ccf70e04, slot#10) 2021-06-26 18:12:31 (20192): Updating drive controller type and model for desired configuration. 2021-06-26 18:12:32 (20192): Setting Memory Size for VM. (3072MB) 2021-06-26 18:12:32 (20192): Setting CPU Count for VM. (1) 2021-06-26 18:12:32 (20192): Setting Chipset Options for VM. 2021-06-26 18:12:33 (20192): Setting Boot Options for VM. 2021-06-26 18:12:33 (20192): Setting Network Configuration for NAT. 2021-06-26 18:12:33 (20192): Enabling VM Network Access. 2021-06-26 18:12:34 (20192): Disabling USB Support for VM. 2021-06-26 18:12:34 (20192): Disabling COM Port Support for VM. 2021-06-26 18:12:34 (20192): Disabling LPT Port Support for VM. 2021-06-26 18:12:35 (20192): Disabling Audio Support for VM. 2021-06-26 18:12:35 (20192): Disabling Clipboard Support for VM. 2021-06-26 18:12:35 (20192): Disabling Drag and Drop Support for VM. 2021-06-26 18:12:36 (20192): Adding storage controller(s) to VM. 2021-06-26 18:12:36 (20192): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso) 2021-06-26 18:12:36 (20192): Adding VirtualBox Guest Additions to VM. 2021-06-26 18:12:37 (20192): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2021-06-26 18:12:37 (20192): Enabling shared directory for VM. 2021-06-26 18:12:38 (20192): Starting VM using VBoxManage interface. (boinc_5d5fdf23ccf70e04, slot#10) 2021-06-26 18:12:40 (20192): Error in start VM for VM: -2147467259 Command: VBoxManage -q startvm "boinc_5d5fdf23ccf70e04" --type headless Output: Waiting for VM "boinc_5d5fdf23ccf70e04" to power on... VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: AMD-V is disabled in the BIOS (or by the host OS) (VERR_SVM_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2021-06-26 18:12:40 (20192): VM failed to start. 2021-06-26 18:12:40 (20192): Could not start 2021-06-26 18:12:40 (20192): ERROR: VM failed to start 2021-06-26 18:12:40 (20192): Powering off VM. 2021-06-26 18:12:40 (20192): Deregistering VM. (boinc_5d5fdf23ccf70e04, slot#10) 2021-06-26 18:12:40 (20192): Removing network bandwidth throttle group from VM. 2021-06-26 18:12:41 (20192): Removing VM from VirtualBox. 2021-06-26 18:12:41 (20192): Removing virtual ISO 9660 disk from VirtualBox. Hypervisor System Log: 00:02:04.540796 Saving settings file "D:\BOINC\slots\8\boinc_6672c74262aea511\boinc_6672c74262aea511.vbox" with version "1.16-windows" 00:02:04.638173 Saving settings file "D:\BOINC\slots\7\boinc_6b2ef459368c2540\boinc_6b2ef459368c2540.vbox" with version "1.16-windows" 00:02:04.812567 Saving settings file "D:\BOINC\slots\8\boinc_6672c74262aea511\boinc_6672c74262aea511.vbox" with version "1.16-windows" 00:02:04.906911 Saving settings file "D:\BOINC\slots\7\boinc_6b2ef459368c2540\boinc_6b2ef459368c2540.vbox" with version "1.16-windows" 00:02:05.083734 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:02:05.086297 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:02:05.086433 Saving settings file "C:\Users\commander\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:02:05.091130 Saving settings file "C:\Users\commander\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:02:05.093919 Saving settings file "D:\BOINC\slots\8\boinc_6672c74262aea511\boinc_6672c74262aea511.vbox" with version "1.16-windows" 00:02:05.181672 Saving settings file "D:\BOINC\slots\7\boinc_6b2ef459368c2540\boinc_6b2ef459368c2540.vbox" with version "1.16-windows" 00:02:05.356270 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:02:05.356583 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:02:05.357058 Saving settings file "D:\BOINC\slots\8\boinc_6672c74262aea511\boinc_6672c74262aea511.vbox" with version "1.16-windows" 00:02:05.458265 Saving settings file "D:\BOINC\slots\7\boinc_6b2ef459368c2540\boinc_6b2ef459368c2540.vbox" with version "1.16-windows" 00:02:05.625236 Saving settings file "D:\BOINC\slots\8\boinc_6672c74262aea511\boinc_6672c74262aea511.vbox" with version "1.16-windows" 00:02:05.721872 Saving settings file "D:\BOINC\slots\7\boinc_6b2ef459368c2540\boinc_6b2ef459368c2540.vbox" with version "1.16-windows" 00:02:05.897313 Saving settings file "D:\BOINC\slots\8\boinc_6672c74262aea511\boinc_6672c74262aea511.vbox" with version "1.16-windows" 00:02:05.993420 Saving settings file "D:\BOINC\slots\7\boinc_6b2ef459368c2540\boinc_6b2ef459368c2540.vbox" with version "1.16-windows" 00:02:06.170665 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:02:06.170763 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:02:06.175589 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:02:06.263489 Saving settings file "D:\BOINC\slots\7\boinc_6b2ef459368c2540\boinc_6b2ef459368c2540.vbox" with version "1.16-windows" 00:02:06.451707 Launched VM: 69174416 pid: 7640 (0x1dd8) frontend: headless name: boinc_6672c74262aea511 00:02:06.537530 Saving settings file "D:\BOINC\slots\7\boinc_6b2ef459368c2540\boinc_6b2ef459368c2540.vbox" with version "1.16-windows" 00:02:06.808746 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:02:06.811177 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:02:06.811313 Saving settings file "C:\Users\commander\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:02:06.814378 Saving settings file "C:\Users\commander\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:02:06.817492 Saving settings file "D:\BOINC\slots\7\boinc_6b2ef459368c2540\boinc_6b2ef459368c2540.vbox" with version "1.16-windows" 00:02:07.077091 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:02:07.077424 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:02:07.077865 Saving settings file "D:\BOINC\slots\7\boinc_6b2ef459368c2540\boinc_6b2ef459368c2540.vbox" with version "1.16-windows" 00:02:07.347755 Saving settings file "D:\BOINC\slots\7\boinc_6b2ef459368c2540\boinc_6b2ef459368c2540.vbox" with version "1.16-windows" 00:02:07.622740 Saving settings file "D:\BOINC\slots\7\boinc_6b2ef459368c2540\boinc_6b2ef459368c2540.vbox" with version "1.16-windows" 00:02:07.894437 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:02:07.894533 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:02:07.899018 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:02:08.175403 Launched VM: 69276656 pid: 18080 (0x46a0) frontend: headless name: boinc_6b2ef459368c2540 00:02:09.537721 Saving settings file "D:\BOINC\slots\8\boinc_6672c74262aea511\boinc_6672c74262aea511.vbox" with version "1.16-windows" 00:02:09.643905 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:02:09.958604 Saving settings file "C:\Users\commander\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:02:10.953066 Saving settings file "D:\BOINC\slots\7\boinc_6b2ef459368c2540\boinc_6b2ef459368c2540.vbox" with version "1.16-windows" 00:02:11.077279 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:02:11.404049 Saving settings file "C:\Users\commander\.VirtualBox\VirtualBox.xml" with version "1.12-windows" VM Execution Log: VM Startup Log: VM Trace Log: disk format: VDI VRDE auth library: VBoxAuth Webservice auth. library: VBoxAuth Remote desktop ExtPack: Log history count: 3 Default frontend: Default audio driver: DirectSound Autostart database path: Default Guest Additions ISO: C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso Logging Level: all Proxy Mode: System Proxy URL: 2021-06-26 18:12:31 (20192): Command: VBoxManage -q list hostinfo Exit Code: 0 Output: Host Information: Host time: 2021-06-26T22:12:30.880000000Z Processor online count: 16 Processor count: 16 Processor online core count: 8 Processor core count: 8 Processor supports HW virtualization: no Processor supports PAE: yes Processor supports long mode: yes Processor supports nested paging: no Processor supports unrestricted guest: no Processor supports nested HW virtualization: no Processor#0 speed: unknown Processor#0 description: AMD Ryzen 7 3700X 8-Core Processor Processor#1 speed: unknown Processor#1 description: AMD Ryzen 7 3700X 8-Core Processor Processor#2 speed: unknown Processor#2 description: AMD Ryzen 7 3700X 8-Core Processor Processor#3 speed: unknown Processor#3 description: AMD Ryzen 7 3700X 8-Core Processor Processor#4 speed: unknown Processor#4 description: AMD Ryzen 7 3700X 8-Core Processor Processor#5 speed: unknown Processor#5 description: AMD Ryzen 7 3700X 8-Core Processor Processor#6 speed: unknown Processor#6 description: AMD Ryzen 7 3700X 8-Core Processor Processor#7 speed: unknown Processor#7 description: AMD Ryzen 7 3700X 8-Core Processor Processor#8 speed: unknown Processor#8 description: AMD Ryzen 7 3700X 8-Core Processor Processor#9 speed: unknown Processor#9 description: AMD Ryzen 7 3700X 8-Core Processor Processor#10 speed: unknown Processor#10 description: AMD Ryzen 7 3700X 8-Core Processor Processor#11 speed: unknown Processor#11 description: AMD Ryzen 7 3700X 8-Core Processor Processor#12 speed: unknown Processor#12 description: AMD Ryzen 7 3700X 8-Core Processor Processor#13 speed: unknown Processor#13 description: AMD Ryzen 7 3700X 8-Core Processor Processor#14 speed: unknown Processor#14 description: AMD Ryzen 7 3700X 8-Core Processor Processor#15 speed: unknown Processor#15 description: AMD Ryzen 7 3700X 8-Core Processor Memory size: 32683 MByte Memory available: 21593 MByte Operating system: Windows 10 Operating system version: 10.0.19042 2021-06-26 18:12:31 (20192): Command: VBoxManage -q showvminfo "boinc_5d5fdf23ccf70e04" --machinereadable Exit Code: -2135228415 Output: VBoxManage.exe: error: Could not find a registered machine named 'boinc_5d5fdf23ccf70e04' VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2715 of file VBoxManageInfo.cpp 2021-06-26 18:12:31 (20192): Command: VBoxManage -q showhdinfo "D:\BOINC\slots\10/vm_image.vdi" Exit Code: -2135228412 Output: VBoxManage.exe: error: Could not find file for the medium 'D:\BOINC\slots\10\vm_image.vdi' (VERR_FILE_NOT_FOUND) VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp 2021-06-26 18:12:31 (20192): Command: VBoxManage -q createvm --name "boinc_5d5fdf23ccf70e04" --basefolder "D:\BOINC\slots\10" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_5d5fdf23ccf70e04' is created and registered. UUID: 32607681-0007-4919-b0b4-32f3b7f2dd4c Settings file: 'D:\BOINC\slots\10\boinc_5d5fdf23ccf70e04\boinc_5d5fdf23ccf70e04.vbox' 2021-06-26 18:12:32 (20192): Command: VBoxManage -q modifyvm "boinc_5d5fdf23ccf70e04" --description "08385652_084_1" Exit Code: 0 Output: 2021-06-26 18:12:32 (20192): Command: VBoxManage -q modifyvm "boinc_5d5fdf23ccf70e04" --memory 3072 Exit Code: 0 Output: 2021-06-26 18:12:32 (20192): Command: VBoxManage -q modifyvm "boinc_5d5fdf23ccf70e04" --cpus 1 Exit Code: 0 Output: 2021-06-26 18:12:33 (20192): Command: VBoxManage -q modifyvm "boinc_5d5fdf23ccf70e04" --acpi on --ioapic on Exit Code: 0 Output: 2021-06-26 18:12:33 (20192): Command: VBoxManage -q modifyvm "boinc_5d5fdf23ccf70e04" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2021-06-26 18:12:33 (20192): Command: VBoxManage -q modifyvm "boinc_5d5fdf23ccf70e04" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2021-06-26 18:12:34 (20192): Command: VBoxManage -q modifyvm "boinc_5d5fdf23ccf70e04" --cableconnected1 on Exit Code: 0 Output: 2021-06-26 18:12:34 (20192): Command: VBoxManage -q modifyvm "boinc_5d5fdf23ccf70e04" --usb off Exit Code: 0 Output: 2021-06-26 18:12:34 (20192): Command: VBoxManage -q modifyvm "boinc_5d5fdf23ccf70e04" --uart1 off --uart2 off Exit Code: 0 Output: 2021-06-26 18:12:35 (20192): Command: VBoxManage -q modifyvm "boinc_5d5fdf23ccf70e04" --lpt1 off --lpt2 off Exit Code: 0 Output: 2021-06-26 18:12:35 (20192): Command: VBoxManage -q modifyvm "boinc_5d5fdf23ccf70e04" --audio none Exit Code: 0 Output: 2021-06-26 18:12:35 (20192): Command: VBoxManage -q modifyvm "boinc_5d5fdf23ccf70e04" --clipboard disabled Exit Code: 0 Output: 2021-06-26 18:12:36 (20192): Command: VBoxManage -q modifyvm "boinc_5d5fdf23ccf70e04" --draganddrop disabled Exit Code: 0 Output: 2021-06-26 18:12:36 (20192): Command: VBoxManage -q storagectl "boinc_5d5fdf23ccf70e04" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2021-06-26 18:12:36 (20192): Command: VBoxManage -q storageattach "boinc_5d5fdf23ccf70e04" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "D:\BOINC\slots\10/vm_isocontext.iso" Exit Code: 0 Output: 2021-06-26 18:12:37 (20192): Command: VBoxManage -q storageattach "boinc_5d5fdf23ccf70e04" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2021-06-26 18:12:37 (20192): Command: VBoxManage -q bandwidthctl "boinc_5d5fdf23ccf70e04" add "boinc_5d5fdf23ccf70e04_net" --type network --limit 1024G Exit Code: 0 Output: 2021-06-26 18:12:37 (20192): Command: VBoxManage -q sharedfolder add "boinc_5d5fdf23ccf70e04" --name "shared" --hostpath "D:\BOINC\slots\10/shared" Exit Code: 0 Output: 2021-06-26 18:12:40 (20192): Command: VBoxManage -q startvm "boinc_5d5fdf23ccf70e04" --type headless Exit Code: -2147467259 Output: Waiting for VM "boinc_5d5fdf23ccf70e04" to power on... VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: AMD-V is disabled in the BIOS (or by the host OS) (VERR_SVM_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2021-06-26 18:12:40 (20192): Command: VBoxManage -q snapshot "boinc_5d5fdf23ccf70e04" list Exit Code: -108 Output: This machine does not have any snapshots 2021-06-26 18:12:41 (20192): Command: VBoxManage -q bandwidthctl "boinc_5d5fdf23ccf70e04" remove "boinc_5d5fdf23ccf70e04_net" Exit Code: 0 Output: VBoxManage.exe: error: Bandwidth groups cannot be deleted while the VM is running 2021-06-26 18:12:41 (20192): Command: VBoxManage -q unregistervm "boinc_5d5fdf23ccf70e04" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 2021-06-26 18:12:41 (20192): Command: VBoxManage -q closemedium dvd "D:\BOINC\slots\10/vm_isocontext.iso" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 18:12:51 (20192): called boinc_finish(-2147467259) </stderr_txt> ]]>
©2025 COPYRIGHT 2017-2018 NCN