Name | 08385246_13_2 |
Workunit | 8369424 |
Created | 27 Jun 2021, 18:59:55 UTC |
Sent | 27 Jun 2021, 19:26:31 UTC |
Report deadline | 2 Jul 2021, 19:26:31 UTC |
Received | 27 Jun 2021, 20:42:39 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | -2147467259 (0x80004005) Unknown error code |
Computer ID | 11622 |
Run time | 24 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 4.56 GFLOPS |
Application version | boinc2docker v1.14 (vbox64_mt) windows_x86_64 |
Peak working set size | 9.99 MB |
Peak swap size | 2.12 MB |
Peak disk usage | 600.50 MB |
<core_client_version>7.16.11</core_client_version> <![CDATA[ <message> Unspecified error (0x80004005) - exit code 2147500037 (0x80004005)</message> <stderr_txt> 2021-06-27 22:43:49 (752): Detected: vboxwrapper 26202 2021-06-27 22:43:49 (752): Detected: BOINC client v7.16.11 2021-06-27 22:43:50 (752): Detected: VirtualBox VboxManage Interface (Version: 6.1.22) 2021-06-27 22:43:51 (752): Create VM. (boinc_62cb52031980fe9e, slot#4) 2021-06-27 22:43:51 (752): Updating drive controller type and model for desired configuration. 2021-06-27 22:43:54 (752): Setting Memory Size for VM. (3072MB) 2021-06-27 22:43:55 (752): Setting CPU Count for VM. (1) 2021-06-27 22:43:55 (752): Setting Chipset Options for VM. 2021-06-27 22:43:56 (752): Setting Boot Options for VM. 2021-06-27 22:43:57 (752): Setting Network Configuration for NAT. 2021-06-27 22:43:58 (752): Enabling VM Network Access. 2021-06-27 22:43:58 (752): Disabling USB Support for VM. 2021-06-27 22:43:58 (752): Disabling COM Port Support for VM. 2021-06-27 22:43:59 (752): Disabling LPT Port Support for VM. 2021-06-27 22:43:59 (752): Disabling Audio Support for VM. 2021-06-27 22:44:00 (752): Disabling Clipboard Support for VM. 2021-06-27 22:44:01 (752): Disabling Drag and Drop Support for VM. 2021-06-27 22:44:01 (752): Adding storage controller(s) to VM. 2021-06-27 22:44:01 (752): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso) 2021-06-27 22:44:02 (752): Adding VirtualBox Guest Additions to VM. 2021-06-27 22:44:02 (752): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2021-06-27 22:44:02 (752): Enabling shared directory for VM. 2021-06-27 22:44:03 (752): Starting VM using VBoxManage interface. (boinc_62cb52031980fe9e, slot#4) 2021-06-27 22:44:06 (752): Error in start VM for VM: -2147467259 Command: VBoxManage -q startvm "boinc_62cb52031980fe9e" --type headless Output: Waiting for VM "boinc_62cb52031980fe9e" to power on... VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2021-06-27 22:44:06 (752): VM failed to start. 2021-06-27 22:44:06 (752): Could not start 2021-06-27 22:44:06 (752): ERROR: VM failed to start 2021-06-27 22:44:06 (752): Powering off VM. 2021-06-27 22:44:06 (752): Deregistering VM. (boinc_62cb52031980fe9e, slot#4) 2021-06-27 22:44:06 (752): Removing network bandwidth throttle group from VM. 2021-06-27 22:44:06 (752): Removing VM from VirtualBox. 2021-06-27 22:44:06 (752): Removing virtual ISO 9660 disk from VirtualBox. Hypervisor System Log: 00:00:00.324200 Loading settings file "E:\Virtual-machines\VirtualBox VMs\debian\debian.vbox" with version "1.16-windows" 00:00:00.325057 Loading settings file "E:\Virtual-machines\VirtualBox VMs\Arch-linux\Arch-linux.vbox" with version "1.16-windows" 00:00:00.325701 VirtualBox: object created 00:00:01.031875 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={Could not find a registered machine named 'boinc_62cb52031980fe9e'}, preserve=false aResultDetail=0 00:00:01.300205 ERROR [COM]: aRC=VBOX_E_FILE_ERROR (0x80bb0004) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Could not find file for the medium 'E:\Boinc data\slots\4\vm_image.vdi' (VERR_FILE_NOT_FOUND)}, preserve=false aResultDetail=-102 00:00:01.586180 Saving settings file "E:\Boinc data\slots\4\boinc_62cb52031980fe9e\boinc_62cb52031980fe9e.vbox" with version "1.16-windows" 00:00:03.106445 Saving settings file "C:\Users\galan\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:03.535767 Saving settings file "E:\Boinc data\slots\4\boinc_62cb52031980fe9e\boinc_62cb52031980fe9e.vbox" with version "1.16-windows" 00:00:04.347518 Saving settings file "E:\Boinc data\slots\4\boinc_62cb52031980fe9e\boinc_62cb52031980fe9e.vbox" with version "1.16-windows" 00:00:05.134978 Saving settings file "E:\Boinc data\slots\4\boinc_62cb52031980fe9e\boinc_62cb52031980fe9e.vbox" with version "1.16-windows" 00:00:05.415445 Saving settings file "E:\Boinc data\slots\4\boinc_62cb52031980fe9e\boinc_62cb52031980fe9e.vbox" with version "1.16-windows" 00:00:06.283529 Saving settings file "E:\Boinc data\slots\4\boinc_62cb52031980fe9e\boinc_62cb52031980fe9e.vbox" with version "1.16-windows" 00:00:07.097542 Saving settings file "E:\Boinc data\slots\4\boinc_62cb52031980fe9e\boinc_62cb52031980fe9e.vbox" with version "1.16-windows" 00:00:07.900551 Saving settings file "E:\Boinc data\slots\4\boinc_62cb52031980fe9e\boinc_62cb52031980fe9e.vbox" with version "1.16-windows" 00:00:08.436855 Saving settings file "E:\Boinc data\slots\4\boinc_62cb52031980fe9e\boinc_62cb52031980fe9e.vbox" with version "1.16-windows" 00:00:08.710218 Saving settings file "E:\Boinc data\slots\4\boinc_62cb52031980fe9e\boinc_62cb52031980fe9e.vbox" with version "1.16-windows" 00:00:09.531267 Saving settings file "E:\Boinc data\slots\4\boinc_62cb52031980fe9e\boinc_62cb52031980fe9e.vbox" with version "1.16-windows" 00:00:09.819294 Saving settings file "E:\Boinc data\slots\4\boinc_62cb52031980fe9e\boinc_62cb52031980fe9e.vbox" with version "1.16-windows" 00:00:10.100331 Saving settings file "E:\Boinc data\slots\4\boinc_62cb52031980fe9e\boinc_62cb52031980fe9e.vbox" with version "1.16-windows" 00:00:10.904526 Saving settings file "E:\Boinc data\slots\4\boinc_62cb52031980fe9e\boinc_62cb52031980fe9e.vbox" with version "1.16-windows" 00:00:11.194674 Saving settings file "E:\Boinc data\slots\4\boinc_62cb52031980fe9e\boinc_62cb52031980fe9e.vbox" with version "1.16-windows" 00:00:11.539343 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:11.541658 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:11.541826 Saving settings file "C:\Users\galan\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:11.557148 Saving settings file "C:\Users\galan\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:11.572314 Saving settings file "E:\Boinc data\slots\4\boinc_62cb52031980fe9e\boinc_62cb52031980fe9e.vbox" with version "1.16-windows" 00:00:12.074446 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:12.074821 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:12.075261 Saving settings file "E:\Boinc data\slots\4\boinc_62cb52031980fe9e\boinc_62cb52031980fe9e.vbox" with version "1.16-windows" 00:00:12.356132 Saving settings file "E:\Boinc data\slots\4\boinc_62cb52031980fe9e\boinc_62cb52031980fe9e.vbox" with version "1.16-windows" 00:00:12.644065 Saving settings file "E:\Boinc data\slots\4\boinc_62cb52031980fe9e\boinc_62cb52031980fe9e.vbox" with version "1.16-windows" 00:00:12.912155 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:12.912300 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:12.920604 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:13.207112 Launched VM: 63229328 pid: 1768 (0x6e8) frontend: headless name: boinc_62cb52031980fe9e 00:00:15.776502 Saving settings file "E:\Boinc data\slots\4\boinc_62cb52031980fe9e\boinc_62cb52031980fe9e.vbox" with version "1.16-windows" 00:00:15.972180 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:16.050868 Saving settings file "E:\Boinc data\slots\4\boinc_62cb52031980fe9e\boinc_62cb52031980fe9e.vbox" with version "1.16-windows" 00:00:16.345729 Saving settings file "C:\Users\galan\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:21.625698 main VirtualBox: object deletion starts 00:00:21.625748 main ERROR [COM]: aRC=VBOX_E_OBJECT_IN_USE (0x80bb000c) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Medium 'E:\Virtual-machines\VirtualBox VMs\windows\windows.vdi' cannot be closed because it is still attached to 1 virtual machines}, preserve=false aResultDetail=0 00:00:21.626133 main ERROR [COM]: aRC=VBOX_E_OBJECT_IN_USE (0x80bb000c) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Medium 'E:\Virtual-machines\VirtualBox VMs\debian\debian.vdi' cannot be closed because it is still attached to 1 virtual machines}, preserve=false aResultDetail=0 00:00:21.626480 main ERROR [COM]: aRC=VBOX_E_OBJECT_IN_USE (0x80bb000c) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Medium 'E:\Virtual-machines\VirtualBox VMs\Arch-linux\Arch-linux.vdi' cannot be closed because it is still attached to 1 virtual machines}, preserve=false aResultDetail=0 00:00:21.627554 main HostDnsMonitor: shutting down ... 00:00:21.627614 main HostDnsMonitor: shut down 00:00:21.630300 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:21.630504 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: m ICH9 IDE Controllers: 1 Maximum IDE Port count: 2 Maximum Devices per IDE Port: 2 Maximum PIIX3 SATA Controllers: 1 Maximum ICH9 SATA Controllers: 8 Maximum SATA Port count: 30 Maximum Devices per SATA Port: 1 Maximum PIIX3 SCSI Controllers: 1 Maximum ICH9 SCSI Controllers: 8 Maximum SCSI Port count: 16 Maximum Devices per SCSI Port: 1 Maximum SAS PIIX3 Controllers: 1 Maximum SAS ICH9 Controllers: 8 Maximum SAS Port count: 255 Maximum Devices per SAS Port: 1 Maximum NVMe PIIX3 Controllers: 1 Maximum NVMe ICH9 Controllers: 8 Maximum NVMe Port count: 255 Maximum Devices per NVMe Port: 1 Maximum virtio-scsi PIIX3 Controllers: 1 Maximum virtio-scsi ICH9 Controllers: 8 Maximum virtio-scsi Port count: 256 Maximum Devices per virtio-scsi Port: 1 Maximum PIIX3 Floppy Controllers:1 Maximum ICH9 Floppy Controllers: 1 Maximum Floppy Port count: 1 Maximum Devices per Floppy Port: 2 Default machine folder: E:\Virtual-machines\VirtualBox VMs Raw-mode Supported: no Exclusive HW virtualization use: off Default hard disk format: VDI VRDE auth library: VBoxAuth Webservice auth. library: VBoxAuth Remote desktop ExtPack: Log history count: 3 Default frontend: Default audio driver: DirectSound Autostart database path: Default Guest Additions ISO: C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso Logging Level: all Proxy Mode: System Proxy URL: 2021-06-27 22:43:51 (752): Command: VBoxManage -q list hostinfo Exit Code: 0 Output: Host Information: Host time: 2021-06-27T19:43:50.990000000Z Processor online count: 4 Processor count: 4 Processor online core count: 4 Processor core count: 4 Processor supports HW virtualization: no Processor supports PAE: yes Processor supports long mode: yes Processor supports nested paging: no Processor supports unrestricted guest: no Processor supports nested HW virtualization: no Processor#0 speed: unknown Processor#0 description: Intel(R) Core(TM) i5-3570K CPU @ 3.40GHz Processor#1 speed: unknown Processor#1 description: Intel(R) Core(TM) i5-3570K CPU @ 3.40GHz Processor#2 speed: unknown Processor#2 description: Intel(R) Core(TM) i5-3570K CPU @ 3.40GHz Processor#3 speed: unknown Processor#3 description: Intel(R) Core(TM) i5-3570K CPU @ 3.40GHz Memory size: 32711 MByte Memory available: 18932 MByte Operating system: Windows 10 Operating system version: 10.0.19043 2021-06-27 22:43:51 (752): Command: VBoxManage -q showvminfo "boinc_62cb52031980fe9e" --machinereadable Exit Code: -2135228415 Output: VBoxManage.exe: error: Could not find a registered machine named 'boinc_62cb52031980fe9e' VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2727 of file VBoxManageInfo.cpp 2021-06-27 22:43:51 (752): Command: VBoxManage -q showhdinfo "E:\Boinc data\slots\4/vm_image.vdi" Exit Code: -2135228412 Output: VBoxManage.exe: error: Could not find file for the medium 'E:\Boinc data\slots\4\vm_image.vdi' (VERR_FILE_NOT_FOUND) VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp 2021-06-27 22:43:53 (752): Command: VBoxManage -q createvm --name "boinc_62cb52031980fe9e" --basefolder "E:\Boinc data\slots\4" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_62cb52031980fe9e' is created and registered. UUID: 9e1e912b-a5f2-4f03-be71-f9703302f054 Settings file: 'E:\Boinc data\slots\4\boinc_62cb52031980fe9e\boinc_62cb52031980fe9e.vbox' 2021-06-27 22:43:54 (752): Command: VBoxManage -q modifyvm "boinc_62cb52031980fe9e" --description "08385246_13_2" Exit Code: 0 Output: 2021-06-27 22:43:55 (752): Command: VBoxManage -q modifyvm "boinc_62cb52031980fe9e" --memory 3072 Exit Code: 0 Output: 2021-06-27 22:43:55 (752): Command: VBoxManage -q modifyvm "boinc_62cb52031980fe9e" --cpus 1 Exit Code: 0 Output: 2021-06-27 22:43:56 (752): Command: VBoxManage -q modifyvm "boinc_62cb52031980fe9e" --acpi on --ioapic on Exit Code: 0 Output: 2021-06-27 22:43:57 (752): Command: VBoxManage -q modifyvm "boinc_62cb52031980fe9e" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2021-06-27 22:43:58 (752): Command: VBoxManage -q modifyvm "boinc_62cb52031980fe9e" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2021-06-27 22:43:58 (752): Command: VBoxManage -q modifyvm "boinc_62cb52031980fe9e" --cableconnected1 on Exit Code: 0 Output: 2021-06-27 22:43:58 (752): Command: VBoxManage -q modifyvm "boinc_62cb52031980fe9e" --usb off Exit Code: 0 Output: 2021-06-27 22:43:59 (752): Command: VBoxManage -q modifyvm "boinc_62cb52031980fe9e" --uart1 off --uart2 off Exit Code: 0 Output: 2021-06-27 22:43:59 (752): Command: VBoxManage -q modifyvm "boinc_62cb52031980fe9e" --lpt1 off --lpt2 off Exit Code: 0 Output: 2021-06-27 22:44:00 (752): Command: VBoxManage -q modifyvm "boinc_62cb52031980fe9e" --audio none Exit Code: 0 Output: 2021-06-27 22:44:01 (752): Command: VBoxManage -q modifyvm "boinc_62cb52031980fe9e" --clipboard disabled Exit Code: 0 Output: 2021-06-27 22:44:01 (752): Command: VBoxManage -q modifyvm "boinc_62cb52031980fe9e" --draganddrop disabled Exit Code: 0 Output: 2021-06-27 22:44:01 (752): Command: VBoxManage -q storagectl "boinc_62cb52031980fe9e" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2021-06-27 22:44:02 (752): Command: VBoxManage -q storageattach "boinc_62cb52031980fe9e" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "E:\Boinc data\slots\4/vm_isocontext.iso" Exit Code: 0 Output: 2021-06-27 22:44:02 (752): Command: VBoxManage -q storageattach "boinc_62cb52031980fe9e" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2021-06-27 22:44:02 (752): Command: VBoxManage -q bandwidthctl "boinc_62cb52031980fe9e" add "boinc_62cb52031980fe9e_net" --type network --limit 1024G Exit Code: 0 Output: 2021-06-27 22:44:03 (752): Command: VBoxManage -q sharedfolder add "boinc_62cb52031980fe9e" --name "shared" --hostpath "E:\Boinc data\slots\4/shared" Exit Code: 0 Output: 2021-06-27 22:44:06 (752): Command: VBoxManage -q startvm "boinc_62cb52031980fe9e" --type headless Exit Code: -2147467259 Output: Waiting for VM "boinc_62cb52031980fe9e" to power on... VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2021-06-27 22:44:06 (752): Command: VBoxManage -q snapshot "boinc_62cb52031980fe9e" list Exit Code: -108 Output: This machine does not have any snapshots 2021-06-27 22:44:06 (752): Command: VBoxManage -q bandwidthctl "boinc_62cb52031980fe9e" remove "boinc_62cb52031980fe9e_net" Exit Code: 0 Output: 2021-06-27 22:44:06 (752): Command: VBoxManage -q unregistervm "boinc_62cb52031980fe9e" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 2021-06-27 22:44:07 (752): Command: VBoxManage -q closemedium dvd "E:\Boinc data\slots\4/vm_isocontext.iso" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 22:44:12 (752): called boinc_finish(-2147467259) </stderr_txt> ]]>
©2025 COPYRIGHT 2017-2018 NCN