Name | 08386957_125_0 |
Workunit | 8405545 |
Created | 27 Jun 2021, 22:38:08 UTC |
Sent | 28 Jun 2021, 4:57:14 UTC |
Report deadline | 3 Jul 2021, 4:57:14 UTC |
Received | 28 Jun 2021, 6:10:16 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | -2147467259 (0x80004005) Unknown error code |
Computer ID | 8845 |
Run time | 43 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 1.86 GFLOPS |
Application version | boinc2docker v1.14 (vbox64_mt) windows_x86_64 |
Peak working set size | 10.41 MB |
Peak swap size | 6.25 MB |
Peak disk usage | 500.10 MB |
<core_client_version>7.16.11</core_client_version> <![CDATA[ <message> Unspecified error (0x80004005) - exit code 2147500037 (0x80004005)</message> <stderr_txt> 2021-06-28 01:10:33 (7080): Detected: vboxwrapper 26202 2021-06-28 01:10:33 (7080): Detected: BOINC client v7.16.11 2021-06-28 01:10:38 (7080): Detected: VirtualBox VboxManage Interface (Version: 6.1.12) 2021-06-28 01:10:40 (7080): Create VM. (boinc_78c6e19886ef1150, slot#1) 2021-06-28 01:10:40 (7080): Updating drive controller type and model for desired configuration. 2021-06-28 01:10:41 (7080): Setting Memory Size for VM. (3072MB) 2021-06-28 01:10:42 (7080): Setting CPU Count for VM. (1) 2021-06-28 01:10:43 (7080): Setting Chipset Options for VM. 2021-06-28 01:10:43 (7080): Setting Boot Options for VM. 2021-06-28 01:10:44 (7080): Setting Network Configuration for NAT. 2021-06-28 01:10:44 (7080): Enabling VM Network Access. 2021-06-28 01:10:45 (7080): Disabling USB Support for VM. 2021-06-28 01:10:45 (7080): Disabling COM Port Support for VM. 2021-06-28 01:10:46 (7080): Disabling LPT Port Support for VM. 2021-06-28 01:10:46 (7080): Disabling Audio Support for VM. 2021-06-28 01:10:47 (7080): Disabling Clipboard Support for VM. 2021-06-28 01:10:47 (7080): Disabling Drag and Drop Support for VM. 2021-06-28 01:10:48 (7080): Adding storage controller(s) to VM. 2021-06-28 01:10:49 (7080): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso) 2021-06-28 01:10:50 (7080): Adding VirtualBox Guest Additions to VM. 2021-06-28 01:10:50 (7080): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2021-06-28 01:10:51 (7080): Enabling shared directory for VM. 2021-06-28 01:10:52 (7080): Starting VM using VBoxManage interface. (boinc_78c6e19886ef1150, slot#1) 2021-06-28 01:11:05 (7080): Error in start VM for VM: -2147467259 Command: VBoxManage -q startvm "boinc_78c6e19886ef1150" --type headless Output: Waiting for VM "boinc_78c6e19886ef1150" to power on... VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2021-06-28 01:11:05 (7080): VM failed to start. 2021-06-28 01:11:05 (7080): Could not start 2021-06-28 01:11:05 (7080): ERROR: VM failed to start 2021-06-28 01:11:05 (7080): Powering off VM. 2021-06-28 01:11:05 (7080): Deregistering VM. (boinc_78c6e19886ef1150, slot#1) 2021-06-28 01:11:06 (7080): Removing network bandwidth throttle group from VM. 2021-06-28 01:11:06 (7080): Removing VM from VirtualBox. 2021-06-28 01:11:07 (7080): Removing virtual ISO 9660 disk from VirtualBox. Hypervisor System Log: 00:00:11.837566 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:11.908591 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_78c6e19886ef1150\boinc_78c6e19886ef1150.vbox" with version "1.16-windows" 00:00:12.473293 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:12.505233 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:12.793983 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:12.795017 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:12.798446 Saving settings file "C:\Users\Nik\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:13.022393 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:13.022691 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:13.022837 Saving settings file "C:\Users\Nik\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:13.210564 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_78c6e19886ef1150\boinc_78c6e19886ef1150.vbox" with version "1.16-windows" 00:00:13.637749 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:13.643864 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:13.742401 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:13.742730 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:13.742843 Saving settings file "C:\Users\Nik\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:13.854074 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:13.854166 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:13.854286 Saving settings file "C:\Users\Nik\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:13.892249 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_78c6e19886ef1150\boinc_78c6e19886ef1150.vbox" with version "1.16-windows" 00:00:14.359141 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:14.409483 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_78c6e19886ef1150\boinc_78c6e19886ef1150.vbox" with version "1.16-windows" 00:00:14.898144 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:14.917785 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_78c6e19886ef1150\boinc_78c6e19886ef1150.vbox" with version "1.16-windows" 00:00:15.706472 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:15.900503 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:15.901423 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:15.949284 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:16.309998 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:16.472916 Launched VM: 72245040 pid: 1912 (0x778) frontend: headless name: boinc_78c6e19886ef1150 00:00:28.531699 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_78c6e19886ef1150\boinc_78c6e19886ef1150.vbox" with version "1.16-windows" 00:00:29.124823 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:29.130888 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:29.549400 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:29.896633 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:29.931563 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:29.931691 Saving settings file "C:\Users\Nik\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:30.415216 ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={The object functionality is limited}, preserve=false aResultDetail=0 00:00:35.518044 main VirtualBox: object deletion starts 00:00:35.543199 main HostDnsMonitor: shutting down ... 00:00:35.543294 main HostDnsMonitor: shut down 00:00:35.548032 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:35.548321 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: Maximum PIIX3 IDE Controllers: 1 Maximum ICH9 IDE Controllers: 1 Maximum IDE Port count: 2 Maximum Devices per IDE Port: 2 Maximum PIIX3 SATA Controllers: 1 Maximum ICH9 SATA Controllers: 8 Maximum SATA Port count: 30 Maximum Devices per SATA Port: 1 Maximum PIIX3 SCSI Controllers: 1 Maximum ICH9 SCSI Controllers: 8 Maximum SCSI Port count: 16 Maximum Devices per SCSI Port: 1 Maximum SAS PIIX3 Controllers: 1 Maximum SAS ICH9 Controllers: 8 Maximum SAS Port count: 255 Maximum Devices per SAS Port: 1 Maximum NVMe PIIX3 Controllers: 1 Maximum NVMe ICH9 Controllers: 8 Maximum NVMe Port count: 255 Maximum Devices per NVMe Port: 1 Maximum virtio-scsi PIIX3 Controllers: 1 Maximum virtio-scsi ICH9 Controllers: 8 Maximum virtio-scsi Port count: 256 Maximum Devices per virtio-scsi Port: 1 Maximum PIIX3 Floppy Controllers:1 Maximum ICH9 Floppy Controllers: 1 Maximum Floppy Port count: 1 Maximum Devices per Floppy Port: 2 Default machine folder: C:\Users\Nik\VirtualBox VMs Raw-mode Supported: no Exclusive HW virtualization use: off Default hard disk format: VDI VRDE auth library: VBoxAuth Webservice auth. library: VBoxAuth Remote desktop ExtPack: Log history count: 3 Default frontend: Default audio driver: DirectSound Autostart database path: Default Guest Additions ISO: C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso Logging Level: all Proxy Mode: System Proxy URL: 2021-06-28 01:10:39 (7080): Command: VBoxManage -q list hostinfo Exit Code: 0 Output: Host Information: Host time: 2021-06-28T05:10:39.460000000Z Processor online count: 2 Processor count: 2 Processor online core count: 2 Processor core count: 2 Processor supports HW virtualization: no Processor supports PAE: yes Processor supports long mode: yes Processor supports nested paging: no Processor supports unrestricted guest: no Processor supports nested HW virtualization: no Processor#0 speed: unknown Processor#0 description: Intel(R) Celeron(R) CPU 3855U @ 1.60GHz Processor#1 speed: unknown Processor#1 description: Intel(R) Celeron(R) CPU 3855U @ 1.60GHz Memory size: 3893 MByte Memory available: 697 MByte Operating system: Windows 10 Operating system version: 10.0.19042 2021-06-28 01:10:40 (7080): Command: VBoxManage -q showvminfo "boinc_78c6e19886ef1150" --machinereadable Exit Code: -2135228415 Output: VBoxManage.exe: error: Could not find a registered machine named 'boinc_78c6e19886ef1150' VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2715 of file VBoxManageInfo.cpp 2021-06-28 01:10:40 (7080): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\1/vm_image.vdi" Exit Code: -2135228412 Output: VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\1\vm_image.vdi' (VERR_FILE_NOT_FOUND) VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp 2021-06-28 01:10:41 (7080): Command: VBoxManage -q createvm --name "boinc_78c6e19886ef1150" --basefolder "C:\ProgramData\BOINC\slots\1" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_78c6e19886ef1150' is created and registered. UUID: eaece1f6-515b-41f6-bbc0-1e98d73009eb Settings file: 'C:\ProgramData\BOINC\slots\1\boinc_78c6e19886ef1150\boinc_78c6e19886ef1150.vbox' 2021-06-28 01:10:41 (7080): Command: VBoxManage -q modifyvm "boinc_78c6e19886ef1150" --description "08386957_125_0" Exit Code: 0 Output: 2021-06-28 01:10:42 (7080): Command: VBoxManage -q modifyvm "boinc_78c6e19886ef1150" --memory 3072 Exit Code: 0 Output: 2021-06-28 01:10:43 (7080): Command: VBoxManage -q modifyvm "boinc_78c6e19886ef1150" --cpus 1 Exit Code: 0 Output: 2021-06-28 01:10:43 (7080): Command: VBoxManage -q modifyvm "boinc_78c6e19886ef1150" --acpi on --ioapic on Exit Code: 0 Output: 2021-06-28 01:10:44 (7080): Command: VBoxManage -q modifyvm "boinc_78c6e19886ef1150" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2021-06-28 01:10:44 (7080): Command: VBoxManage -q modifyvm "boinc_78c6e19886ef1150" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2021-06-28 01:10:45 (7080): Command: VBoxManage -q modifyvm "boinc_78c6e19886ef1150" --cableconnected1 on Exit Code: 0 Output: 2021-06-28 01:10:45 (7080): Command: VBoxManage -q modifyvm "boinc_78c6e19886ef1150" --usb off Exit Code: 0 Output: 2021-06-28 01:10:46 (7080): Command: VBoxManage -q modifyvm "boinc_78c6e19886ef1150" --uart1 off --uart2 off Exit Code: 0 Output: 2021-06-28 01:10:46 (7080): Command: VBoxManage -q modifyvm "boinc_78c6e19886ef1150" --lpt1 off --lpt2 off Exit Code: 0 Output: 2021-06-28 01:10:47 (7080): Command: VBoxManage -q modifyvm "boinc_78c6e19886ef1150" --audio none Exit Code: 0 Output: 2021-06-28 01:10:47 (7080): Command: VBoxManage -q modifyvm "boinc_78c6e19886ef1150" --clipboard disabled Exit Code: 0 Output: 2021-06-28 01:10:48 (7080): Command: VBoxManage -q modifyvm "boinc_78c6e19886ef1150" --draganddrop disabled Exit Code: 0 Output: 2021-06-28 01:10:49 (7080): Command: VBoxManage -q storagectl "boinc_78c6e19886ef1150" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2021-06-28 01:10:50 (7080): Command: VBoxManage -q storageattach "boinc_78c6e19886ef1150" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\ProgramData\BOINC\slots\1/vm_isocontext.iso" Exit Code: 0 Output: 2021-06-28 01:10:50 (7080): Command: VBoxManage -q storageattach "boinc_78c6e19886ef1150" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2021-06-28 01:10:51 (7080): Command: VBoxManage -q bandwidthctl "boinc_78c6e19886ef1150" add "boinc_78c6e19886ef1150_net" --type network --limit 1024G Exit Code: 0 Output: 2021-06-28 01:10:52 (7080): Command: VBoxManage -q sharedfolder add "boinc_78c6e19886ef1150" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\1/shared" Exit Code: 0 Output: 2021-06-28 01:11:05 (7080): Command: VBoxManage -q startvm "boinc_78c6e19886ef1150" --type headless Exit Code: -2147467259 Output: Waiting for VM "boinc_78c6e19886ef1150" to power on... VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2021-06-28 01:11:06 (7080): Command: VBoxManage -q snapshot "boinc_78c6e19886ef1150" list Exit Code: -108 Output: This machine does not have any snapshots 2021-06-28 01:11:06 (7080): Command: VBoxManage -q bandwidthctl "boinc_78c6e19886ef1150" remove "boinc_78c6e19886ef1150_net" Exit Code: 0 Output: VBoxManage.exe: error: Bandwidth groups cannot be deleted while the VM is running 2021-06-28 01:11:07 (7080): Command: VBoxManage -q unregistervm "boinc_78c6e19886ef1150" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 2021-06-28 01:11:07 (7080): Command: VBoxManage -q closemedium dvd "C:\ProgramData\BOINC\slots\1/vm_isocontext.iso" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 01:11:13 (7080): called boinc_finish(-2147467259) </stderr_txt> ]]>
©2025 COPYRIGHT 2017-2018 NCN