Task 10818248

Name 08386923_17_2
Workunit 8403759
Created 28 Jun 2021, 11:56:48 UTC
Sent 28 Jun 2021, 12:03:07 UTC
Report deadline 3 Jul 2021, 12:03:07 UTC
Received 29 Jun 2021, 7:24:09 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status -2147467259 (0x80004005) Unknown error code
Computer ID 11928
Run time 21 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 2.57 GFLOPS
Application version boinc2docker v1.14 (vbox64_mt)
windows_x86_64
Peak working set size 8.80 MB
Peak swap size 9.99 MB
Peak disk usage 498.58 MB

Stderr output

<core_client_version>7.16.11</core_client_version>
<![CDATA[
<message>
Unspecified error
 (0x80004005) - exit code 2147500037 (0x80004005)</message>
<stderr_txt>
2021-06-28 13:23:03 (11664): Detected: vboxwrapper 26202
2021-06-28 13:23:03 (11664): Detected: BOINC client v7.16.11
2021-06-28 13:23:04 (11664): Detected: VirtualBox VboxManage Interface (Version: 6.1.12)
2021-06-28 13:23:05 (11664): Create VM. (boinc_f4b965ae17630b83, slot#1)
2021-06-28 13:23:05 (11664): Updating drive controller type and model for desired configuration.
2021-06-28 13:23:06 (11664): Setting Memory Size for VM. (3072MB)
2021-06-28 13:23:06 (11664): Setting CPU Count for VM. (1)
2021-06-28 13:23:07 (11664): Setting Chipset Options for VM.
2021-06-28 13:23:07 (11664): Setting Boot Options for VM.
2021-06-28 13:23:07 (11664): Setting Network Configuration for NAT.
2021-06-28 13:23:07 (11664): Enabling VM Network Access.
2021-06-28 13:23:08 (11664): Disabling USB Support for VM.
2021-06-28 13:23:08 (11664): Disabling COM Port Support for VM.
2021-06-28 13:23:08 (11664): Disabling LPT Port Support for VM.
2021-06-28 13:23:09 (11664): Disabling Audio Support for VM.
2021-06-28 13:23:09 (11664): Disabling Clipboard Support for VM.
2021-06-28 13:23:09 (11664): Disabling Drag and Drop Support for VM.
2021-06-28 13:23:09 (11664): Adding storage controller(s) to VM.
2021-06-28 13:23:10 (11664): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso)
2021-06-28 13:23:10 (11664): Adding VirtualBox Guest Additions to VM.
2021-06-28 13:23:10 (11664): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2021-06-28 13:23:11 (11664): Enabling shared directory for VM.
2021-06-28 13:23:11 (11664): Starting VM using VBoxManage interface. (boinc_f4b965ae17630b83, slot#1)
2021-06-28 13:23:15 (11664): Error in start VM for VM: -2147467259
Command:
VBoxManage -q startvm "boinc_f4b965ae17630b83" --type headless
Output:
Waiting for VM "boinc_f4b965ae17630b83" to power on...
VBoxManage.exe: error: The native API dll was not found (C:\WINDOWS\system32\WinHvPlatform.dll) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole

2021-06-28 13:23:15 (11664): VM failed to start.
2021-06-28 13:23:15 (11664): Could not start 
2021-06-28 13:23:15 (11664): ERROR: VM failed to start
2021-06-28 13:23:15 (11664): Powering off VM.
2021-06-28 13:23:15 (11664): Deregistering VM. (boinc_f4b965ae17630b83, slot#1)
2021-06-28 13:23:16 (11664): Removing network bandwidth throttle group from VM.
2021-06-28 13:23:16 (11664): Removing VM from VirtualBox.
2021-06-28 13:23:16 (11664): Removing virtual ISO 9660 disk from VirtualBox.

    Hypervisor System Log:

00:00:00.248122          HostDnsMonitor: initializing
00:00:00.257653          HostDnsMonitor: updating information
00:00:00.257682          HostDnsMonitor: old information
00:00:00.257683            no server entries
00:00:00.257684            no domain set
00:00:00.257685            no search string entries
00:00:00.257686          HostDnsMonitor: new information
00:00:00.257686            server 1: 10.0.48.5
00:00:00.257687            server 2: 10.0.48.6
00:00:00.257688            server 3: 8.8.8.8
00:00:00.257688            server 4: 4.2.2.2
00:00:00.257689            domain: CHQ.NNPCGroup.local
00:00:00.257690            no search string entries
00:00:00.329804          SUPR0QueryVTCaps -> VERR_VMX_MSR_ALL_VMX_DISABLED
00:00:00.330355          VD: VDInit finished with VINF_SUCCESS
00:00:00.331509          VirtualBox: object created
00:00:00.772437          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={Could not find a registered machine named 'boinc_f4b965ae17630b83'}, preserve=false aResultDetail=0
00:00:01.050318          ERROR [COM]: aRC=VBOX_E_FILE_ERROR (0x80bb0004) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Could not find file for the medium 'C:\ProgramData\BOINC\slots\1\vm_image.vdi' (VERR_FILE_NOT_FOUND)}, preserve=false aResultDetail=-102
00:00:01.327939          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_f4b965ae17630b83\boinc_f4b965ae17630b83.vbox" with version "1.16-windows"
00:00:01.494865          Saving settings file "C:\Users\RCS017\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:01.839582          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_f4b965ae17630b83\boinc_f4b965ae17630b83.vbox" with version "1.16-windows"
00:00:02.128371          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_f4b965ae17630b83\boinc_f4b965ae17630b83.vbox" with version "1.16-windows"
00:00:02.636111          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_f4b965ae17630b83\boinc_f4b965ae17630b83.vbox" with version "1.16-windows"
00:00:02.921278          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_f4b965ae17630b83\boinc_f4b965ae17630b83.vbox" with version "1.16-windows"
00:00:03.193691          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_f4b965ae17630b83\boinc_f4b965ae17630b83.vbox" with version "1.16-windows"
00:00:03.480544          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_f4b965ae17630b83\boinc_f4b965ae17630b83.vbox" with version "1.16-windows"
00:00:03.752794          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_f4b965ae17630b83\boinc_f4b965ae17630b83.vbox" with version "1.16-windows"
00:00:04.025772          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_f4b965ae17630b83\boinc_f4b965ae17630b83.vbox" with version "1.16-windows"
00:00:04.327522          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_f4b965ae17630b83\boinc_f4b965ae17630b83.vbox" with version "1.16-windows"
00:00:04.603131          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_f4b965ae17630b83\boinc_f4b965ae17630b83.vbox" with version "1.16-windows"
00:00:04.875545          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_f4b965ae17630b83\boinc_f4b965ae17630b83.vbox" with version "1.16-windows"
00:00:05.146977          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_f4b965ae17630b83\boinc_f4b965ae17630b83.vbox" with version "1.16-windows"
00:00:05.419044          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_f4b965ae17630b83\boinc_f4b965ae17630b83.vbox" with version "1.16-windows"
00:00:05.698186          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_f4b965ae17630b83\boinc_f4b965ae17630b83.vbox" with version "1.16-windows"
00:00:06.056884          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.058693          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.058895          Saving settings file "C:\Users\RCS017\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:06.089558          Saving settings file "C:\Users\RCS017\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:06.174016          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_f4b965ae17630b83\boinc_f4b965ae17630b83.vbox" with version "1.16-windows"
00:00:06.328326          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.329959          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.330151          Saving settings file "C:\Users\RCS017\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:06.370597          Saving settings file "C:\Users\RCS017\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:06.452171          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_f4b965ae17630b83\boinc_f4b965ae17630b83.vbox" with version "1.16-windows"
00:00:06.596081          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_f4b965ae17630b83\boinc_f4b965ae17630b83.vbox" with version "1.16-windows"
00:00:06.867501          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_f4b965ae17630b83\boinc_f4b965ae17630b83.vbox" with version "1.16-windows"
00:00:07.144278          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.144434          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.151781          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:07.394294          Launched VM: 68704944 pid: 3492 (0xda4) frontend: headless name: boinc_f4b965ae17630b83
00:00:11.599626          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_f4b965ae17630b83\boinc_f4b965ae17630b83.vbox" with version "1.16-windows"
00:00:11.801377          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:11.869215          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_f4b965ae17630b83\boinc_f4b965ae17630b83.vbox" with version "1.16-windows"
00:00:12.139261          Saving settings file "C:\Users\RCS017\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:17.419444 main     VirtualBox: object deletion starts
00:00:17.420305 main     HostDnsMonitor: shutting down ...
00:00:17.420326 main     HostDnsMonitor: shut down
00:00:17.421390 Watcher  ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0
00:00:17.421592 main     VirtualBox: object deleted

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

:  1
Maximum ICH9 SATA Controllers:   8
Maximum SATA Port count:         30
Maximum Devices per SATA Port:   1
Maximum PIIX3 SCSI Controllers:  1
Maximum ICH9 SCSI Controllers:   8
Maximum SCSI Port count:         16
Maximum Devices per SCSI Port:   1
Maximum SAS PIIX3 Controllers:   1
Maximum SAS ICH9 Controllers:    8
Maximum SAS Port count:          255
Maximum Devices per SAS Port:    1
Maximum NVMe PIIX3 Controllers:  1
Maximum NVMe ICH9 Controllers:   8
Maximum NVMe Port count:         255
Maximum Devices per NVMe Port:   1
Maximum virtio-scsi PIIX3 Controllers:  1
Maximum virtio-scsi ICH9 Controllers:   8
Maximum virtio-scsi Port count:         256
Maximum Devices per virtio-scsi Port:   1
Maximum PIIX3 Floppy Controllers:1
Maximum ICH9 Floppy Controllers: 1
Maximum Floppy Port count:       1
Maximum Devices per Floppy Port: 2
Default machine folder:          C:\Users\RCS017\VirtualBox VMs
Raw-mode Supported:              no
Exclusive HW virtualization use: off
Default hard disk format:        VDI
VRDE auth library:               VBoxAuth
Webservice auth. library:        VBoxAuth
Remote desktop ExtPack:          
Log history count:               3
Default frontend:                
Default audio driver:            DirectSound
Autostart database path:         
Default Guest Additions ISO:     C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso
Logging Level:                   all
Proxy Mode:                      System
Proxy URL:                       

2021-06-28 13:23:04 (11664): 
Command: VBoxManage -q list hostinfo 
Exit Code: 0
Output:
Host Information:

Host time: 2021-06-28T12:23:04.728000000Z
Processor online count: 4
Processor count: 4
Processor online core count: 2
Processor core count: 2
Processor supports HW virtualization: no
Processor supports PAE: yes
Processor supports long mode: yes
Processor supports nested paging: no
Processor supports unrestricted guest: no
Processor supports nested HW virtualization: no
Processor#0 speed: unknown
Processor#0 description: Intel(R) Core(TM) i5-4200U CPU @ 1.60GHz
Processor#1 speed: unknown
Processor#1 description: Intel(R) Core(TM) i5-4200U CPU @ 1.60GHz
Processor#2 speed: unknown
Processor#2 description: Intel(R) Core(TM) i5-4200U CPU @ 1.60GHz
Processor#3 speed: unknown
Processor#3 description: Intel(R) Core(TM) i5-4200U CPU @ 1.60GHz
Memory size: 3993 MByte
Memory available: 1243 MByte
Operating system: Windows 10
Operating system version: 10.0.10240

2021-06-28 13:23:05 (11664): 
Command: VBoxManage -q showvminfo "boinc_f4b965ae17630b83" --machinereadable 
Exit Code: -2135228415
Output:
VBoxManage.exe: error: Could not find a registered machine named 'boinc_f4b965ae17630b83'
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown
VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2715 of file VBoxManageInfo.cpp

2021-06-28 13:23:05 (11664): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\1/vm_image.vdi" 
Exit Code: -2135228412
Output:
VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\1\vm_image.vdi' (VERR_FILE_NOT_FOUND)
VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp

2021-06-28 13:23:06 (11664): 
Command: VBoxManage -q createvm --name "boinc_f4b965ae17630b83" --basefolder "C:\ProgramData\BOINC\slots\1" --ostype "Linux26_64" --register
Exit Code: 0
Output:
Virtual machine 'boinc_f4b965ae17630b83' is created and registered.
UUID: b9cd002d-0a36-43de-ad9d-1072001c9dba
Settings file: 'C:\ProgramData\BOINC\slots\1\boinc_f4b965ae17630b83\boinc_f4b965ae17630b83.vbox'

2021-06-28 13:23:06 (11664): 
Command: VBoxManage -q modifyvm "boinc_f4b965ae17630b83" --description "08386923_17_2" 
Exit Code: 0
Output:

2021-06-28 13:23:06 (11664): 
Command: VBoxManage -q modifyvm "boinc_f4b965ae17630b83" --memory 3072 
Exit Code: 0
Output:

2021-06-28 13:23:07 (11664): 
Command: VBoxManage -q modifyvm "boinc_f4b965ae17630b83" --cpus 1 
Exit Code: 0
Output:

2021-06-28 13:23:07 (11664): 
Command: VBoxManage -q modifyvm "boinc_f4b965ae17630b83" --acpi on --ioapic on 
Exit Code: 0
Output:

2021-06-28 13:23:07 (11664): 
Command: VBoxManage -q modifyvm "boinc_f4b965ae17630b83" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2021-06-28 13:23:07 (11664): 
Command: VBoxManage -q modifyvm "boinc_f4b965ae17630b83" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2021-06-28 13:23:08 (11664): 
Command: VBoxManage -q modifyvm "boinc_f4b965ae17630b83" --cableconnected1 on 
Exit Code: 0
Output:

2021-06-28 13:23:08 (11664): 
Command: VBoxManage -q modifyvm "boinc_f4b965ae17630b83" --usb off 
Exit Code: 0
Output:

2021-06-28 13:23:08 (11664): 
Command: VBoxManage -q modifyvm "boinc_f4b965ae17630b83" --uart1 off --uart2 off 
Exit Code: 0
Output:

2021-06-28 13:23:09 (11664): 
Command: VBoxManage -q modifyvm "boinc_f4b965ae17630b83" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2021-06-28 13:23:09 (11664): 
Command: VBoxManage -q modifyvm "boinc_f4b965ae17630b83" --audio none 
Exit Code: 0
Output:

2021-06-28 13:23:09 (11664): 
Command: VBoxManage -q modifyvm "boinc_f4b965ae17630b83" --clipboard disabled 
Exit Code: 0
Output:

2021-06-28 13:23:09 (11664): 
Command: VBoxManage -q modifyvm "boinc_f4b965ae17630b83" --draganddrop disabled 
Exit Code: 0
Output:

2021-06-28 13:23:10 (11664): 
Command: VBoxManage -q storagectl "boinc_f4b965ae17630b83" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2021-06-28 13:23:10 (11664): 
Command: VBoxManage -q storageattach "boinc_f4b965ae17630b83" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\ProgramData\BOINC\slots\1/vm_isocontext.iso" 
Exit Code: 0
Output:

2021-06-28 13:23:10 (11664): 
Command: VBoxManage -q storageattach "boinc_f4b965ae17630b83" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2021-06-28 13:23:11 (11664): 
Command: VBoxManage -q bandwidthctl "boinc_f4b965ae17630b83" add "boinc_f4b965ae17630b83_net" --type network --limit 1024G 
Exit Code: 0
Output:

2021-06-28 13:23:11 (11664): 
Command: VBoxManage -q sharedfolder add "boinc_f4b965ae17630b83" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\1/shared"
Exit Code: 0
Output:

2021-06-28 13:23:15 (11664): 
Command: VBoxManage -q startvm "boinc_f4b965ae17630b83" --type headless
Exit Code: -2147467259
Output:
Waiting for VM "boinc_f4b965ae17630b83" to power on...
VBoxManage.exe: error: The native API dll was not found (C:\WINDOWS\system32\WinHvPlatform.dll) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole

2021-06-28 13:23:16 (11664): 
Command: VBoxManage -q snapshot "boinc_f4b965ae17630b83" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2021-06-28 13:23:16 (11664): 
Command: VBoxManage -q bandwidthctl "boinc_f4b965ae17630b83" remove "boinc_f4b965ae17630b83_net" 
Exit Code: 0
Output:

2021-06-28 13:23:16 (11664): 
Command: VBoxManage -q unregistervm "boinc_f4b965ae17630b83" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

2021-06-28 13:23:16 (11664): 
Command: VBoxManage -q closemedium dvd "C:\ProgramData\BOINC\slots\1/vm_isocontext.iso" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

13:23:21 (11664): called boinc_finish(-2147467259)

</stderr_txt>
]]>


©2024 COPYRIGHT 2017-2018 NCN