Task 10862289

Name 08387916_071_1
Workunit 8426466
Created 30 Jun 2021, 19:01:12 UTC
Sent 30 Jun 2021, 19:27:58 UTC
Report deadline 5 Jul 2021, 19:27:58 UTC
Received 1 Jul 2021, 19:38:43 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status -2147467259 (0x80004005) Unknown error code
Computer ID 6301
Run time 16 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 3.59 GFLOPS
Application version boinc2docker v1.14 (vbox64_mt)
windows_x86_64
Peak working set size 11.16 MB
Peak swap size 6.39 MB
Peak disk usage 278.17 MB

Stderr output

<core_client_version>7.16.11</core_client_version>
<![CDATA[
<message>
Unspecified error
 (0x80004005) - exit code 2147500037 (0x80004005)</message>
<stderr_txt>
2021-06-30 15:32:57 (21016): Detected: vboxwrapper 26202
2021-06-30 15:32:57 (21016): Detected: BOINC client v7.16.11
2021-06-30 15:32:59 (21016): Detected: VirtualBox VboxManage Interface (Version: 6.1.22)
2021-06-30 15:33:00 (21016): Create VM. (boinc_5804d28d33224c6f, slot#2)
2021-06-30 15:33:00 (21016): Updating drive controller type and model for desired configuration.
2021-06-30 15:33:01 (21016): Setting Memory Size for VM. (3072MB)
2021-06-30 15:33:01 (21016): Setting CPU Count for VM. (1)
2021-06-30 15:33:01 (21016): Setting Chipset Options for VM.
2021-06-30 15:33:02 (21016): Setting Boot Options for VM.
2021-06-30 15:33:02 (21016): Setting Network Configuration for NAT.
2021-06-30 15:33:02 (21016): Enabling VM Network Access.
2021-06-30 15:33:02 (21016): Disabling USB Support for VM.
2021-06-30 15:33:03 (21016): Disabling COM Port Support for VM.
2021-06-30 15:33:03 (21016): Disabling LPT Port Support for VM.
2021-06-30 15:33:03 (21016): Disabling Audio Support for VM.
2021-06-30 15:33:04 (21016): Disabling Clipboard Support for VM.
2021-06-30 15:33:04 (21016): Disabling Drag and Drop Support for VM.
2021-06-30 15:33:04 (21016): Adding storage controller(s) to VM.
2021-06-30 15:33:05 (21016): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso)
2021-06-30 15:33:05 (21016): Adding VirtualBox Guest Additions to VM.
2021-06-30 15:33:05 (21016): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2021-06-30 15:33:06 (21016): Enabling shared directory for VM.
2021-06-30 15:33:06 (21016): Starting VM using VBoxManage interface. (boinc_5804d28d33224c6f, slot#2)
2021-06-30 15:33:11 (21016): Error in start VM for VM: -2147467259
Command:
VBoxManage -q startvm "boinc_5804d28d33224c6f" --type headless
Output:
Waiting for VM "boinc_5804d28d33224c6f" to power on...
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole

2021-06-30 15:33:11 (21016): VM failed to start.
2021-06-30 15:33:11 (21016): Could not start 
2021-06-30 15:33:11 (21016): ERROR: VM failed to start
2021-06-30 15:33:11 (21016): Powering off VM.
2021-06-30 15:33:11 (21016): Deregistering VM. (boinc_5804d28d33224c6f, slot#2)
2021-06-30 15:33:11 (21016): Removing network bandwidth throttle group from VM.
2021-06-30 15:33:12 (21016): Removing VM from VirtualBox.
2021-06-30 15:33:12 (21016): Removing virtual ISO 9660 disk from VirtualBox.

    Hypervisor System Log:

00:00:00.759592          HostDnsMonitor: initializing
00:00:00.780977          HostDnsMonitor: updating information
00:00:00.781017          HostDnsMonitor: old information
00:00:00.781018            no server entries
00:00:00.781019            no domain set
00:00:00.781020            no search string entries
00:00:00.781021          HostDnsMonitor: new information
00:00:00.781021            server 1: 100.120.96.1
00:00:00.781022            server 2: 75.75.75.75
00:00:00.781023            server 3: 75.75.76.76
00:00:00.781024            domain: hsd1.md.comcast.net
00:00:00.781025            no search string entries
00:00:00.964985          SUPR0QueryVTCaps -> VERR_VMX_MSR_ALL_VMX_DISABLED
00:00:00.965951          VD: VDInit finished with VINF_SUCCESS
00:00:00.968146          VirtualBox: object created
00:00:01.624557          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={Could not find a registered machine named 'boinc_5804d28d33224c6f'}, preserve=false aResultDetail=0
00:00:01.895292          ERROR [COM]: aRC=VBOX_E_FILE_ERROR (0x80bb0004) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Could not find file for the medium 'C:\ProgramData\BOINC\slots\2\vm_image.vdi' (VERR_FILE_NOT_FOUND)}, preserve=false aResultDetail=-102
00:00:02.224497          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_5804d28d33224c6f\boinc_5804d28d33224c6f.vbox" with version "1.16-windows"
00:00:02.278476          Saving settings file "C:\Users\kirkj\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:02.519944          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_5804d28d33224c6f\boinc_5804d28d33224c6f.vbox" with version "1.16-windows"
00:00:02.834350          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_5804d28d33224c6f\boinc_5804d28d33224c6f.vbox" with version "1.16-windows"
00:00:03.141477          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_5804d28d33224c6f\boinc_5804d28d33224c6f.vbox" with version "1.16-windows"
00:00:03.402098          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_5804d28d33224c6f\boinc_5804d28d33224c6f.vbox" with version "1.16-windows"
00:00:03.781479          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_5804d28d33224c6f\boinc_5804d28d33224c6f.vbox" with version "1.16-windows"
00:00:04.003863          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_5804d28d33224c6f\boinc_5804d28d33224c6f.vbox" with version "1.16-windows"
00:00:04.337582          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_5804d28d33224c6f\boinc_5804d28d33224c6f.vbox" with version "1.16-windows"
00:00:04.650772          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_5804d28d33224c6f\boinc_5804d28d33224c6f.vbox" with version "1.16-windows"
00:00:04.962312          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_5804d28d33224c6f\boinc_5804d28d33224c6f.vbox" with version "1.16-windows"
00:00:05.257375          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_5804d28d33224c6f\boinc_5804d28d33224c6f.vbox" with version "1.16-windows"
00:00:05.556673          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_5804d28d33224c6f\boinc_5804d28d33224c6f.vbox" with version "1.16-windows"
00:00:05.853075          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_5804d28d33224c6f\boinc_5804d28d33224c6f.vbox" with version "1.16-windows"
00:00:06.161646          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_5804d28d33224c6f\boinc_5804d28d33224c6f.vbox" with version "1.16-windows"
00:00:06.456362          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_5804d28d33224c6f\boinc_5804d28d33224c6f.vbox" with version "1.16-windows"
00:00:06.770439          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.776403          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.776893          Saving settings file "C:\Users\kirkj\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:06.804090          Saving settings file "C:\Users\kirkj\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:06.842911          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_5804d28d33224c6f\boinc_5804d28d33224c6f.vbox" with version "1.16-windows"
00:00:07.101591          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.106662          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.107000          Saving settings file "C:\Users\kirkj\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:07.133426          Saving settings file "C:\Users\kirkj\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:07.155112          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_5804d28d33224c6f\boinc_5804d28d33224c6f.vbox" with version "1.16-windows"
00:00:07.412090          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_5804d28d33224c6f\boinc_5804d28d33224c6f.vbox" with version "1.16-windows"
00:00:07.701962          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_5804d28d33224c6f\boinc_5804d28d33224c6f.vbox" with version "1.16-windows"
00:00:07.986767          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.987409          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.003819          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:08.288132          Launched VM: 75530400 pid: 17324 (0x43ac) frontend: headless name: boinc_5804d28d33224c6f
00:00:12.899115          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_5804d28d33224c6f\boinc_5804d28d33224c6f.vbox" with version "1.16-windows"
00:00:13.295850          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:13.410401          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_5804d28d33224c6f\boinc_5804d28d33224c6f.vbox" with version "1.16-windows"
00:00:13.761107          Saving settings file "C:\Users\kirkj\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:19.066891 main     VirtualBox: object deletion starts
00:00:19.067944 main     HostDnsMonitor: shutting down ...
00:00:19.068002 main     HostDnsMonitor: shut down
00:00:19.070815 Watcher  ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0
00:00:19.070999 main     VirtualBox: object deleted

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

:    2
Maximum PIIX3 SATA Controllers:  1
Maximum ICH9 SATA Controllers:   8
Maximum SATA Port count:         30
Maximum Devices per SATA Port:   1
Maximum PIIX3 SCSI Controllers:  1
Maximum ICH9 SCSI Controllers:   8
Maximum SCSI Port count:         16
Maximum Devices per SCSI Port:   1
Maximum SAS PIIX3 Controllers:   1
Maximum SAS ICH9 Controllers:    8
Maximum SAS Port count:          255
Maximum Devices per SAS Port:    1
Maximum NVMe PIIX3 Controllers:  1
Maximum NVMe ICH9 Controllers:   8
Maximum NVMe Port count:         255
Maximum Devices per NVMe Port:   1
Maximum virtio-scsi PIIX3 Controllers:  1
Maximum virtio-scsi ICH9 Controllers:   8
Maximum virtio-scsi Port count:         256
Maximum Devices per virtio-scsi Port:   1
Maximum PIIX3 Floppy Controllers:1
Maximum ICH9 Floppy Controllers: 1
Maximum Floppy Port count:       1
Maximum Devices per Floppy Port: 2
Default machine folder:          C:\Users\kirkj\VirtualBox VMs
Raw-mode Supported:              no
Exclusive HW virtualization use: off
Default hard disk format:        VDI
VRDE auth library:               VBoxAuth
Webservice auth. library:        VBoxAuth
Remote desktop ExtPack:          
Log history count:               3
Default frontend:                
Default audio driver:            DirectSound
Autostart database path:         
Default Guest Additions ISO:     C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso
Logging Level:                   all
Proxy Mode:                      System
Proxy URL:                       

2021-06-30 15:32:59 (21016): 
Command: VBoxManage -q list hostinfo 
Exit Code: 0
Output:
Host Information:

Host time: 2021-06-30T19:32:59.748000000Z
Processor online count: 4
Processor count: 4
Processor online core count: 2
Processor core count: 2
Processor supports HW virtualization: no
Processor supports PAE: yes
Processor supports long mode: yes
Processor supports nested paging: no
Processor supports unrestricted guest: no
Processor supports nested HW virtualization: no
Processor#0 speed: unknown
Processor#0 description: Intel(R) Core(TM) i3-4130 CPU @ 3.40GHz
Processor#1 speed: unknown
Processor#1 description: Intel(R) Core(TM) i3-4130 CPU @ 3.40GHz
Processor#2 speed: unknown
Processor#2 description: Intel(R) Core(TM) i3-4130 CPU @ 3.40GHz
Processor#3 speed: unknown
Processor#3 description: Intel(R) Core(TM) i3-4130 CPU @ 3.40GHz
Memory size: 16323 MByte
Memory available: 8057 MByte
Operating system: Windows 10
Operating system version: 10.0.19042

2021-06-30 15:33:00 (21016): 
Command: VBoxManage -q showvminfo "boinc_5804d28d33224c6f" --machinereadable 
Exit Code: -2135228415
Output:
VBoxManage.exe: error: Could not find a registered machine named 'boinc_5804d28d33224c6f'
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown
VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2727 of file VBoxManageInfo.cpp

2021-06-30 15:33:00 (21016): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\2/vm_image.vdi" 
Exit Code: -2135228412
Output:
VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\2\vm_image.vdi' (VERR_FILE_NOT_FOUND)
VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp

2021-06-30 15:33:00 (21016): 
Command: VBoxManage -q createvm --name "boinc_5804d28d33224c6f" --basefolder "C:\ProgramData\BOINC\slots\2" --ostype "Linux26_64" --register
Exit Code: 0
Output:
Virtual machine 'boinc_5804d28d33224c6f' is created and registered.
UUID: 4fb97cb8-f523-4df6-84d9-951b55ee9756
Settings file: 'C:\ProgramData\BOINC\slots\2\boinc_5804d28d33224c6f\boinc_5804d28d33224c6f.vbox'

2021-06-30 15:33:01 (21016): 
Command: VBoxManage -q modifyvm "boinc_5804d28d33224c6f" --description "08387916_071_1" 
Exit Code: 0
Output:

2021-06-30 15:33:01 (21016): 
Command: VBoxManage -q modifyvm "boinc_5804d28d33224c6f" --memory 3072 
Exit Code: 0
Output:

2021-06-30 15:33:01 (21016): 
Command: VBoxManage -q modifyvm "boinc_5804d28d33224c6f" --cpus 1 
Exit Code: 0
Output:

2021-06-30 15:33:02 (21016): 
Command: VBoxManage -q modifyvm "boinc_5804d28d33224c6f" --acpi on --ioapic on 
Exit Code: 0
Output:

2021-06-30 15:33:02 (21016): 
Command: VBoxManage -q modifyvm "boinc_5804d28d33224c6f" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2021-06-30 15:33:02 (21016): 
Command: VBoxManage -q modifyvm "boinc_5804d28d33224c6f" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2021-06-30 15:33:02 (21016): 
Command: VBoxManage -q modifyvm "boinc_5804d28d33224c6f" --cableconnected1 on 
Exit Code: 0
Output:

2021-06-30 15:33:03 (21016): 
Command: VBoxManage -q modifyvm "boinc_5804d28d33224c6f" --usb off 
Exit Code: 0
Output:

2021-06-30 15:33:03 (21016): 
Command: VBoxManage -q modifyvm "boinc_5804d28d33224c6f" --uart1 off --uart2 off 
Exit Code: 0
Output:

2021-06-30 15:33:03 (21016): 
Command: VBoxManage -q modifyvm "boinc_5804d28d33224c6f" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2021-06-30 15:33:04 (21016): 
Command: VBoxManage -q modifyvm "boinc_5804d28d33224c6f" --audio none 
Exit Code: 0
Output:

2021-06-30 15:33:04 (21016): 
Command: VBoxManage -q modifyvm "boinc_5804d28d33224c6f" --clipboard disabled 
Exit Code: 0
Output:

2021-06-30 15:33:04 (21016): 
Command: VBoxManage -q modifyvm "boinc_5804d28d33224c6f" --draganddrop disabled 
Exit Code: 0
Output:

2021-06-30 15:33:05 (21016): 
Command: VBoxManage -q storagectl "boinc_5804d28d33224c6f" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2021-06-30 15:33:05 (21016): 
Command: VBoxManage -q storageattach "boinc_5804d28d33224c6f" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\ProgramData\BOINC\slots\2/vm_isocontext.iso" 
Exit Code: 0
Output:

2021-06-30 15:33:05 (21016): 
Command: VBoxManage -q storageattach "boinc_5804d28d33224c6f" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2021-06-30 15:33:06 (21016): 
Command: VBoxManage -q bandwidthctl "boinc_5804d28d33224c6f" add "boinc_5804d28d33224c6f_net" --type network --limit 1024G 
Exit Code: 0
Output:

2021-06-30 15:33:06 (21016): 
Command: VBoxManage -q sharedfolder add "boinc_5804d28d33224c6f" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\2/shared"
Exit Code: 0
Output:

2021-06-30 15:33:11 (21016): 
Command: VBoxManage -q startvm "boinc_5804d28d33224c6f" --type headless
Exit Code: -2147467259
Output:
Waiting for VM "boinc_5804d28d33224c6f" to power on...
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole

2021-06-30 15:33:11 (21016): 
Command: VBoxManage -q snapshot "boinc_5804d28d33224c6f" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2021-06-30 15:33:12 (21016): 
Command: VBoxManage -q bandwidthctl "boinc_5804d28d33224c6f" remove "boinc_5804d28d33224c6f_net" 
Exit Code: 0
Output:

2021-06-30 15:33:12 (21016): 
Command: VBoxManage -q unregistervm "boinc_5804d28d33224c6f" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

2021-06-30 15:33:12 (21016): 
Command: VBoxManage -q closemedium dvd "C:\ProgramData\BOINC\slots\2/vm_isocontext.iso" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

15:33:22 (21016): called boinc_finish(-2147467259)

</stderr_txt>
]]>


©2024 COPYRIGHT 2017-2018 NCN