Task 10872009

Name 08390215_41_0
Workunit 8451157
Created 1 Jul 2021, 9:06:30 UTC
Sent 1 Jul 2021, 17:05:31 UTC
Report deadline 6 Jul 2021, 17:05:31 UTC
Received 1 Jul 2021, 18:10:37 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status -2147467259 (0x80004005) Unknown error code
Computer ID 10598
Run time 19 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 4.00 GFLOPS
Application version boinc2docker v1.14 (vbox64_mt)
windows_x86_64
Peak working set size 10.34 MB
Peak swap size 7.20 MB
Peak disk usage 290.75 MB

Stderr output

<core_client_version>7.16.11</core_client_version>
<![CDATA[
<message>
Unspecified error
 (0x80004005) - exit code 2147500037 (0x80004005)</message>
<stderr_txt>
2021-07-01 18:10:16 (1416): Detected: vboxwrapper 26202
2021-07-01 18:10:16 (1416): Detected: BOINC client v7.16.11
2021-07-01 18:10:17 (1416): Detected: VirtualBox VboxManage Interface (Version: 6.1.12)
2021-07-01 18:10:18 (1416): Create VM. (boinc_212bd03045ad50dc, slot#4)
2021-07-01 18:10:18 (1416): Updating drive controller type and model for desired configuration.
2021-07-01 18:10:18 (1416): Setting Memory Size for VM. (3072MB)
2021-07-01 18:10:19 (1416): Setting CPU Count for VM. (1)
2021-07-01 18:10:19 (1416): Setting Chipset Options for VM.
2021-07-01 18:10:19 (1416): Setting Boot Options for VM.
2021-07-01 18:10:20 (1416): Setting Network Configuration for NAT.
2021-07-01 18:10:20 (1416): Enabling VM Network Access.
2021-07-01 18:10:20 (1416): Disabling USB Support for VM.
2021-07-01 18:10:20 (1416): Disabling COM Port Support for VM.
2021-07-01 18:10:21 (1416): Disabling LPT Port Support for VM.
2021-07-01 18:10:21 (1416): Disabling Audio Support for VM.
2021-07-01 18:10:21 (1416): Disabling Clipboard Support for VM.
2021-07-01 18:10:22 (1416): Disabling Drag and Drop Support for VM.
2021-07-01 18:10:22 (1416): Adding storage controller(s) to VM.
2021-07-01 18:10:22 (1416): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso)
2021-07-01 18:10:22 (1416): Adding VirtualBox Guest Additions to VM.
2021-07-01 18:10:23 (1416): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2021-07-01 18:10:23 (1416): Enabling shared directory for VM.
2021-07-01 18:10:23 (1416): Starting VM using VBoxManage interface. (boinc_212bd03045ad50dc, slot#4)
2021-07-01 18:10:27 (1416): Error in start VM for VM: -2147467259
Command:
VBoxManage -q startvm "boinc_212bd03045ad50dc" --type headless
Output:
Waiting for VM "boinc_212bd03045ad50dc" to power on...
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole

2021-07-01 18:10:27 (1416): VM failed to start.
2021-07-01 18:10:27 (1416): Could not start 
2021-07-01 18:10:27 (1416): ERROR: VM failed to start
2021-07-01 18:10:27 (1416): Powering off VM.
2021-07-01 18:10:27 (1416): Deregistering VM. (boinc_212bd03045ad50dc, slot#4)
2021-07-01 18:10:27 (1416): Removing network bandwidth throttle group from VM.
2021-07-01 18:10:28 (1416): Removing VM from VirtualBox.
2021-07-01 18:10:28 (1416): Removing virtual ISO 9660 disk from VirtualBox.

    Hypervisor System Log:

00:00:00.308571          netIfIsWireless: CreateFile on '\\.\{AAE76E7F-85F6-49C6-8001-D34A9AAAA2FB}' failed with rcWin=2 (0x2) - ignoring
00:00:00.328550          HostDnsMonitor: initializing
00:00:00.345423          HostDnsMonitor: updating information
00:00:00.345524          HostDnsMonitor: old information
00:00:00.345525            no server entries
00:00:00.345527            no domain set
00:00:00.345527            no search string entries
00:00:00.345528          HostDnsMonitor: new information
00:00:00.345529            server 1: 192.168.1.1
00:00:00.345530            no domain set
00:00:00.345530            no search string entries
00:00:00.575380          SUPR0QueryVTCaps -> VERR_VMX_MSR_ALL_VMX_DISABLED
00:00:00.576429          VD: VDInit finished with VINF_SUCCESS
00:00:00.584072          VirtualBox: object created
00:00:01.154707          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={Could not find a registered machine named 'boinc_212bd03045ad50dc'}, preserve=false aResultDetail=0
00:00:01.417487          ERROR [COM]: aRC=VBOX_E_FILE_ERROR (0x80bb0004) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Could not find file for the medium 'C:\ProgramData\BOINC\slots\4\vm_image.vdi' (VERR_FILE_NOT_FOUND)}, preserve=false aResultDetail=-102
00:00:01.706576          Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_212bd03045ad50dc\boinc_212bd03045ad50dc.vbox" with version "1.16-windows"
00:00:01.717480          Saving settings file "C:\Users\nessu\.VirtualBox\VirtualBox.xml" with version "1.14-windows"
00:00:01.983146          Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_212bd03045ad50dc\boinc_212bd03045ad50dc.vbox" with version "1.16-windows"
00:00:02.268128          Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_212bd03045ad50dc\boinc_212bd03045ad50dc.vbox" with version "1.16-windows"
00:00:02.539323          Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_212bd03045ad50dc\boinc_212bd03045ad50dc.vbox" with version "1.16-windows"
00:00:02.815651          Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_212bd03045ad50dc\boinc_212bd03045ad50dc.vbox" with version "1.16-windows"
00:00:03.083649          Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_212bd03045ad50dc\boinc_212bd03045ad50dc.vbox" with version "1.16-windows"
00:00:03.364018          Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_212bd03045ad50dc\boinc_212bd03045ad50dc.vbox" with version "1.16-windows"
00:00:03.625793          Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_212bd03045ad50dc\boinc_212bd03045ad50dc.vbox" with version "1.16-windows"
00:00:03.916558          Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_212bd03045ad50dc\boinc_212bd03045ad50dc.vbox" with version "1.16-windows"
00:00:04.188378          Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_212bd03045ad50dc\boinc_212bd03045ad50dc.vbox" with version "1.16-windows"
00:00:04.461292          Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_212bd03045ad50dc\boinc_212bd03045ad50dc.vbox" with version "1.16-windows"
00:00:04.739563          Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_212bd03045ad50dc\boinc_212bd03045ad50dc.vbox" with version "1.16-windows"
00:00:05.046606          Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_212bd03045ad50dc\boinc_212bd03045ad50dc.vbox" with version "1.16-windows"
00:00:05.332008          Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_212bd03045ad50dc\boinc_212bd03045ad50dc.vbox" with version "1.16-windows"
00:00:05.643110          Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_212bd03045ad50dc\boinc_212bd03045ad50dc.vbox" with version "1.16-windows"
00:00:05.933871          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:05.941453          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:05.943190          Saving settings file "C:\Users\nessu\.VirtualBox\VirtualBox.xml" with version "1.14-windows"
00:00:05.955192          Saving settings file "C:\Users\nessu\.VirtualBox\VirtualBox.xml" with version "1.14-windows"
00:00:05.966517          Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_212bd03045ad50dc\boinc_212bd03045ad50dc.vbox" with version "1.16-windows"
00:00:06.201496          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.205064          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.207323          Saving settings file "C:\Users\nessu\.VirtualBox\VirtualBox.xml" with version "1.14-windows"
00:00:06.219428          Saving settings file "C:\Users\nessu\.VirtualBox\VirtualBox.xml" with version "1.14-windows"
00:00:06.231054          Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_212bd03045ad50dc\boinc_212bd03045ad50dc.vbox" with version "1.16-windows"
00:00:06.471284          Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_212bd03045ad50dc\boinc_212bd03045ad50dc.vbox" with version "1.16-windows"
00:00:06.748853          Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_212bd03045ad50dc\boinc_212bd03045ad50dc.vbox" with version "1.16-windows"
00:00:07.046581          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.047004          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.072449          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:07.306284          Launched VM: 90079168 pid: 14844 (0x39fc) frontend: headless name: boinc_212bd03045ad50dc
00:00:10.873031          Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_212bd03045ad50dc\boinc_212bd03045ad50dc.vbox" with version "1.16-windows"
00:00:11.015203          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:11.121873          Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_212bd03045ad50dc\boinc_212bd03045ad50dc.vbox" with version "1.16-windows"
00:00:11.386100          Saving settings file "C:\Users\nessu\.VirtualBox\VirtualBox.xml" with version "1.14-windows"
00:00:16.659175 main     VirtualBox: object deletion starts
00:00:16.671874 main     HostDnsMonitor: shutting down ...
00:00:16.672023 main     HostDnsMonitor: shut down
00:00:16.678230 Watcher  ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0
00:00:16.679461 main     VirtualBox: object deleted

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

ICH9 Controllers:    8
Maximum SAS Port count:          255
Maximum Devices per SAS Port:    1
Maximum NVMe PIIX3 Controllers:  1
Maximum NVMe ICH9 Controllers:   8
Maximum NVMe Port count:         255
Maximum Devices per NVMe Port:   1
Maximum virtio-scsi PIIX3 Controllers:  1
Maximum virtio-scsi ICH9 Controllers:   8
Maximum virtio-scsi Port count:         256
Maximum Devices per virtio-scsi Port:   1
Maximum PIIX3 Floppy Controllers:1
Maximum ICH9 Floppy Controllers: 1
Maximum Floppy Port count:       1
Maximum Devices per Floppy Port: 2
Default machine folder:          C:\Users\nessu\VirtualBox VMs
Raw-mode Supported:              no
Exclusive HW virtualization use: off
Default hard disk format:        VDI
VRDE auth library:               VBoxAuth
Webservice auth. library:        VBoxAuth
Remote desktop ExtPack:          
Log history count:               3
Default frontend:                
Default audio driver:            DirectSound
Autostart database path:         
Default Guest Additions ISO:     C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso
Logging Level:                   all
Proxy Mode:                      System
Proxy URL:                       

2021-07-01 18:10:17 (1416): 
Command: VBoxManage -q list hostinfo 
Exit Code: 0
Output:
Host Information:

Host time: 2021-07-01T17:10:17.670000000Z
Processor online count: 8
Processor count: 8
Processor online core count: 4
Processor core count: 4
Processor supports HW virtualization: no
Processor supports PAE: yes
Processor supports long mode: yes
Processor supports nested paging: no
Processor supports unrestricted guest: no
Processor supports nested HW virtualization: no
Processor#0 speed: unknown
Processor#0 description: Intel(R) Core(TM) i7-6700 CPU @ 3.40GHz
Processor#1 speed: unknown
Processor#1 description: Intel(R) Core(TM) i7-6700 CPU @ 3.40GHz
Processor#2 speed: unknown
Processor#2 description: Intel(R) Core(TM) i7-6700 CPU @ 3.40GHz
Processor#3 speed: unknown
Processor#3 description: Intel(R) Core(TM) i7-6700 CPU @ 3.40GHz
Processor#4 speed: unknown
Processor#4 description: Intel(R) Core(TM) i7-6700 CPU @ 3.40GHz
Processor#5 speed: unknown
Processor#5 description: Intel(R) Core(TM) i7-6700 CPU @ 3.40GHz
Processor#6 speed: unknown
Processor#6 description: Intel(R) Core(TM) i7-6700 CPU @ 3.40GHz
Processor#7 speed: unknown
Processor#7 description: Intel(R) Core(TM) i7-6700 CPU @ 3.40GHz
Memory size: 65455 MByte
Memory available: 50901 MByte
Operating system: Windows 8
Operating system version: 6.2.9200

2021-07-01 18:10:18 (1416): 
Command: VBoxManage -q showvminfo "boinc_212bd03045ad50dc" --machinereadable 
Exit Code: -2135228415
Output:
VBoxManage.exe: error: Could not find a registered machine named 'boinc_212bd03045ad50dc'
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown
VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2715 of file VBoxManageInfo.cpp

2021-07-01 18:10:18 (1416): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\4/vm_image.vdi" 
Exit Code: -2135228412
Output:
VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\4\vm_image.vdi' (VERR_FILE_NOT_FOUND)
VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp

2021-07-01 18:10:18 (1416): 
Command: VBoxManage -q createvm --name "boinc_212bd03045ad50dc" --basefolder "C:\ProgramData\BOINC\slots\4" --ostype "Linux26_64" --register
Exit Code: 0
Output:
Virtual machine 'boinc_212bd03045ad50dc' is created and registered.
UUID: 03e8f257-c719-4909-867f-e03910d433e0
Settings file: 'C:\ProgramData\BOINC\slots\4\boinc_212bd03045ad50dc\boinc_212bd03045ad50dc.vbox'

2021-07-01 18:10:18 (1416): 
Command: VBoxManage -q modifyvm "boinc_212bd03045ad50dc" --description "08390215_41_0" 
Exit Code: 0
Output:

2021-07-01 18:10:19 (1416): 
Command: VBoxManage -q modifyvm "boinc_212bd03045ad50dc" --memory 3072 
Exit Code: 0
Output:

2021-07-01 18:10:19 (1416): 
Command: VBoxManage -q modifyvm "boinc_212bd03045ad50dc" --cpus 1 
Exit Code: 0
Output:

2021-07-01 18:10:19 (1416): 
Command: VBoxManage -q modifyvm "boinc_212bd03045ad50dc" --acpi on --ioapic on 
Exit Code: 0
Output:

2021-07-01 18:10:20 (1416): 
Command: VBoxManage -q modifyvm "boinc_212bd03045ad50dc" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2021-07-01 18:10:20 (1416): 
Command: VBoxManage -q modifyvm "boinc_212bd03045ad50dc" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2021-07-01 18:10:20 (1416): 
Command: VBoxManage -q modifyvm "boinc_212bd03045ad50dc" --cableconnected1 on 
Exit Code: 0
Output:

2021-07-01 18:10:20 (1416): 
Command: VBoxManage -q modifyvm "boinc_212bd03045ad50dc" --usb off 
Exit Code: 0
Output:

2021-07-01 18:10:21 (1416): 
Command: VBoxManage -q modifyvm "boinc_212bd03045ad50dc" --uart1 off --uart2 off 
Exit Code: 0
Output:

2021-07-01 18:10:21 (1416): 
Command: VBoxManage -q modifyvm "boinc_212bd03045ad50dc" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2021-07-01 18:10:21 (1416): 
Command: VBoxManage -q modifyvm "boinc_212bd03045ad50dc" --audio none 
Exit Code: 0
Output:

2021-07-01 18:10:22 (1416): 
Command: VBoxManage -q modifyvm "boinc_212bd03045ad50dc" --clipboard disabled 
Exit Code: 0
Output:

2021-07-01 18:10:22 (1416): 
Command: VBoxManage -q modifyvm "boinc_212bd03045ad50dc" --draganddrop disabled 
Exit Code: 0
Output:

2021-07-01 18:10:22 (1416): 
Command: VBoxManage -q storagectl "boinc_212bd03045ad50dc" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2021-07-01 18:10:22 (1416): 
Command: VBoxManage -q storageattach "boinc_212bd03045ad50dc" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\ProgramData\BOINC\slots\4/vm_isocontext.iso" 
Exit Code: 0
Output:

2021-07-01 18:10:23 (1416): 
Command: VBoxManage -q storageattach "boinc_212bd03045ad50dc" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2021-07-01 18:10:23 (1416): 
Command: VBoxManage -q bandwidthctl "boinc_212bd03045ad50dc" add "boinc_212bd03045ad50dc_net" --type network --limit 1024G 
Exit Code: 0
Output:

2021-07-01 18:10:23 (1416): 
Command: VBoxManage -q sharedfolder add "boinc_212bd03045ad50dc" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\4/shared"
Exit Code: 0
Output:

2021-07-01 18:10:27 (1416): 
Command: VBoxManage -q startvm "boinc_212bd03045ad50dc" --type headless
Exit Code: -2147467259
Output:
Waiting for VM "boinc_212bd03045ad50dc" to power on...
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole

2021-07-01 18:10:27 (1416): 
Command: VBoxManage -q snapshot "boinc_212bd03045ad50dc" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2021-07-01 18:10:28 (1416): 
Command: VBoxManage -q bandwidthctl "boinc_212bd03045ad50dc" remove "boinc_212bd03045ad50dc_net" 
Exit Code: 0
Output:

2021-07-01 18:10:28 (1416): 
Command: VBoxManage -q unregistervm "boinc_212bd03045ad50dc" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

2021-07-01 18:10:28 (1416): 
Command: VBoxManage -q closemedium dvd "C:\ProgramData\BOINC\slots\4/vm_isocontext.iso" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

18:10:33 (1416): called boinc_finish(-2147467259)

</stderr_txt>
]]>


©2024 COPYRIGHT 2017-2018 NCN