Task 10877802

Name 08385520_29_1
Workunit 8374090
Created 1 Jul 2021, 16:46:13 UTC
Sent 1 Jul 2021, 17:21:27 UTC
Report deadline 6 Jul 2021, 17:21:27 UTC
Received 1 Jul 2021, 17:45:34 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status -2147467259 (0x80004005) Unknown error code
Computer ID 12191
Run time 16 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 1.00 GFLOPS
Application version boinc2docker v1.14 (vbox64_mt)
windows_x86_64
Peak working set size 10.89 MB
Peak swap size 6.24 MB
Peak disk usage 273.78 MB

Stderr output

<core_client_version>7.16.11</core_client_version>
<![CDATA[
<message>
Unspecified error
 (0x80004005) - exit code 2147500037 (0x80004005)</message>
<stderr_txt>
2021-07-01 13:32:00 (7888): Detected: vboxwrapper 26202
2021-07-01 13:32:00 (7888): Detected: BOINC client v7.16.11
2021-07-01 13:32:01 (7888): Detected: VirtualBox VboxManage Interface (Version: 6.1.18)
2021-07-01 13:32:02 (7888): Create VM. (boinc_f2713dce885fccc6, slot#6)
2021-07-01 13:32:02 (7888): Updating drive controller type and model for desired configuration.
2021-07-01 13:32:02 (7888): Setting Memory Size for VM. (3072MB)
2021-07-01 13:32:02 (7888): Setting CPU Count for VM. (1)
2021-07-01 13:32:03 (7888): Setting Chipset Options for VM.
2021-07-01 13:32:03 (7888): Setting Boot Options for VM.
2021-07-01 13:32:03 (7888): Setting Network Configuration for NAT.
2021-07-01 13:32:03 (7888): Enabling VM Network Access.
2021-07-01 13:32:04 (7888): Disabling USB Support for VM.
2021-07-01 13:32:04 (7888): Disabling COM Port Support for VM.
2021-07-01 13:32:04 (7888): Disabling LPT Port Support for VM.
2021-07-01 13:32:04 (7888): Disabling Audio Support for VM.
2021-07-01 13:32:05 (7888): Disabling Clipboard Support for VM.
2021-07-01 13:32:05 (7888): Disabling Drag and Drop Support for VM.
2021-07-01 13:32:05 (7888): Adding storage controller(s) to VM.
2021-07-01 13:32:06 (7888): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso)
2021-07-01 13:32:06 (7888): Adding VirtualBox Guest Additions to VM.
2021-07-01 13:32:06 (7888): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2021-07-01 13:32:06 (7888): Enabling shared directory for VM.
2021-07-01 13:32:07 (7888): Starting VM using VBoxManage interface. (boinc_f2713dce885fccc6, slot#6)
2021-07-01 13:32:08 (7888): Error in start VM for VM: -2147467259
Command:
VBoxManage -q startvm "boinc_f2713dce885fccc6" --type headless
Output:
Waiting for VM "boinc_f2713dce885fccc6" to power on...
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: AMD-V is disabled in the BIOS (or by the host OS) (VERR_SVM_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole

2021-07-01 13:32:08 (7888): VM failed to start.
2021-07-01 13:32:08 (7888): Could not start 
2021-07-01 13:32:08 (7888): ERROR: VM failed to start
2021-07-01 13:32:08 (7888): Powering off VM.
2021-07-01 13:32:08 (7888): Deregistering VM. (boinc_f2713dce885fccc6, slot#6)
2021-07-01 13:32:09 (7888): Removing network bandwidth throttle group from VM.
2021-07-01 13:32:09 (7888): Removing VM from VirtualBox.
2021-07-01 13:32:09 (7888): Removing virtual ISO 9660 disk from VirtualBox.

    Hypervisor System Log:

00:00:04.532387          Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_f2c74655e8a9bab7\boinc_f2c74655e8a9bab7.vbox" with version "1.16-windows"
00:00:04.612017          Saving settings file "C:\ProgramData\BOINC\slots\6\boinc_f2713dce885fccc6\boinc_f2713dce885fccc6.vbox" with version "1.16-windows"
00:00:04.786353          Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_f2c74655e8a9bab7\boinc_f2c74655e8a9bab7.vbox" with version "1.16-windows"
00:00:04.866066          Saving settings file "C:\ProgramData\BOINC\slots\6\boinc_f2713dce885fccc6\boinc_f2713dce885fccc6.vbox" with version "1.16-windows"
00:00:05.040879          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:05.041944          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:05.042048          Saving settings file "C:\Users\shemp\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:05.044459          Saving settings file "C:\Users\shemp\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:05.046938          Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_f2c74655e8a9bab7\boinc_f2c74655e8a9bab7.vbox" with version "1.16-windows"
00:00:05.120666          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:05.121326          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:05.121417          Saving settings file "C:\Users\shemp\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:05.123588          Saving settings file "C:\Users\shemp\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:05.125865          Saving settings file "C:\ProgramData\BOINC\slots\6\boinc_f2713dce885fccc6\boinc_f2713dce885fccc6.vbox" with version "1.16-windows"
00:00:05.296769          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:05.297460          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:05.297554          Saving settings file "C:\Users\shemp\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:05.299865          Saving settings file "C:\Users\shemp\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:05.302219          Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_f2c74655e8a9bab7\boinc_f2c74655e8a9bab7.vbox" with version "1.16-windows"
00:00:05.377550          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:05.377850          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:05.378151          Saving settings file "C:\ProgramData\BOINC\slots\6\boinc_f2713dce885fccc6\boinc_f2713dce885fccc6.vbox" with version "1.16-windows"
00:00:05.555192          Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_f2c74655e8a9bab7\boinc_f2c74655e8a9bab7.vbox" with version "1.16-windows"
00:00:05.634266          Saving settings file "C:\ProgramData\BOINC\slots\6\boinc_f2713dce885fccc6\boinc_f2713dce885fccc6.vbox" with version "1.16-windows"
00:00:05.807926          Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_f2c74655e8a9bab7\boinc_f2c74655e8a9bab7.vbox" with version "1.16-windows"
00:00:05.887690          Saving settings file "C:\ProgramData\BOINC\slots\6\boinc_f2713dce885fccc6\boinc_f2713dce885fccc6.vbox" with version "1.16-windows"
00:00:06.066696          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.066788          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.071528          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:06.146984          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.147069          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.151279          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:06.319455          Launched VM: 64441328 pid: 1668 (0x684) frontend: headless name: boinc_f2c74655e8a9bab7
00:00:06.400372          Launched VM: 64283584 pid: 13112 (0x3338) frontend: headless name: boinc_f2713dce885fccc6
00:00:07.994623          Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_f2c74655e8a9bab7\boinc_f2c74655e8a9bab7.vbox" with version "1.16-windows"
00:00:08.032097          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:08.045114          Saving settings file "C:\ProgramData\BOINC\slots\6\boinc_f2713dce885fccc6\boinc_f2713dce885fccc6.vbox" with version "1.16-windows"
00:00:08.081724          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:08.312089          Saving settings file "C:\Users\shemp\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:08.369956          Saving settings file "C:\Users\shemp\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:13.641468 main     VirtualBox: object deletion starts
00:00:13.641814 main     HostDnsMonitor: shutting down ...
00:00:13.641836 main     HostDnsMonitor: shut down
00:00:13.643343 Watcher  ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0
00:00:13.643437 main     VirtualBox: object deleted

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

io-scsi Port:   1
Maximum PIIX3 Floppy Controllers:1
Maximum ICH9 Floppy Controllers: 1
Maximum Floppy Port count:       1
Maximum Devices per Floppy Port: 2
Default machine folder:          C:\Users\shemp\VirtualBox VMs
Raw-mode Supported:              no
Exclusive HW virtualization use: off
Default hard disk format:        VDI
VRDE auth library:               VBoxAuth
Webservice auth. library:        VBoxAuth
Remote desktop ExtPack:          
Log history count:               3
Default frontend:                
Default audio driver:            DirectSound
Autostart database path:         
Default Guest Additions ISO:     C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso
Logging Level:                   all
Proxy Mode:                      System
Proxy URL:                       

2021-07-01 13:32:01 (7888): 
Command: VBoxManage -q list hostinfo 
Exit Code: 0
Output:
Host Information:

Host time: 2021-07-01T17:32:01.423000000Z
Processor online count: 12
Processor count: 12
Processor online core count: 6
Processor core count: 6
Processor supports HW virtualization: no
Processor supports PAE: yes
Processor supports long mode: yes
Processor supports nested paging: no
Processor supports unrestricted guest: no
Processor supports nested HW virtualization: no
Processor#0 speed: unknown
Processor#0 description: AMD Ryzen 5 5600X 6-Core Processor
Processor#1 speed: unknown
Processor#1 description: AMD Ryzen 5 5600X 6-Core Processor
Processor#2 speed: unknown
Processor#2 description: AMD Ryzen 5 5600X 6-Core Processor
Processor#3 speed: unknown
Processor#3 description: AMD Ryzen 5 5600X 6-Core Processor
Processor#4 speed: unknown
Processor#4 description: AMD Ryzen 5 5600X 6-Core Processor
Processor#5 speed: unknown
Processor#5 description: AMD Ryzen 5 5600X 6-Core Processor
Processor#6 speed: unknown
Processor#6 description: AMD Ryzen 5 5600X 6-Core Processor
Processor#7 speed: unknown
Processor#7 description: AMD Ryzen 5 5600X 6-Core Processor
Processor#8 speed: unknown
Processor#8 description: AMD Ryzen 5 5600X 6-Core Processor
Processor#9 speed: unknown
Processor#9 description: AMD Ryzen 5 5600X 6-Core Processor
Processor#10 speed: unknown
Processor#10 description: AMD Ryzen 5 5600X 6-Core Processor
Processor#11 speed: unknown
Processor#11 description: AMD Ryzen 5 5600X 6-Core Processor
Memory size: 32678 MByte
Memory available: 24246 MByte
Operating system: Windows 10
Operating system version: 10.0.19043

2021-07-01 13:32:01 (7888): 
Command: VBoxManage -q showvminfo "boinc_f2713dce885fccc6" --machinereadable 
Exit Code: -2135228415
Output:
VBoxManage.exe: error: Could not find a registered machine named 'boinc_f2713dce885fccc6'
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown
VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2715 of file VBoxManageInfo.cpp

2021-07-01 13:32:02 (7888): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\6/vm_image.vdi" 
Exit Code: -2135228412
Output:
VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\6\vm_image.vdi' (VERR_FILE_NOT_FOUND)
VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp

2021-07-01 13:32:02 (7888): 
Command: VBoxManage -q createvm --name "boinc_f2713dce885fccc6" --basefolder "C:\ProgramData\BOINC\slots\6" --ostype "Linux26_64" --register
Exit Code: 0
Output:
Virtual machine 'boinc_f2713dce885fccc6' is created and registered.
UUID: ff7406bd-edc2-41ed-8052-a7971ca4684b
Settings file: 'C:\ProgramData\BOINC\slots\6\boinc_f2713dce885fccc6\boinc_f2713dce885fccc6.vbox'

2021-07-01 13:32:02 (7888): 
Command: VBoxManage -q modifyvm "boinc_f2713dce885fccc6" --description "08385520_29_1" 
Exit Code: 0
Output:

2021-07-01 13:32:02 (7888): 
Command: VBoxManage -q modifyvm "boinc_f2713dce885fccc6" --memory 3072 
Exit Code: 0
Output:

2021-07-01 13:32:03 (7888): 
Command: VBoxManage -q modifyvm "boinc_f2713dce885fccc6" --cpus 1 
Exit Code: 0
Output:

2021-07-01 13:32:03 (7888): 
Command: VBoxManage -q modifyvm "boinc_f2713dce885fccc6" --acpi on --ioapic on 
Exit Code: 0
Output:

2021-07-01 13:32:03 (7888): 
Command: VBoxManage -q modifyvm "boinc_f2713dce885fccc6" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2021-07-01 13:32:03 (7888): 
Command: VBoxManage -q modifyvm "boinc_f2713dce885fccc6" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2021-07-01 13:32:04 (7888): 
Command: VBoxManage -q modifyvm "boinc_f2713dce885fccc6" --cableconnected1 on 
Exit Code: 0
Output:

2021-07-01 13:32:04 (7888): 
Command: VBoxManage -q modifyvm "boinc_f2713dce885fccc6" --usb off 
Exit Code: 0
Output:

2021-07-01 13:32:04 (7888): 
Command: VBoxManage -q modifyvm "boinc_f2713dce885fccc6" --uart1 off --uart2 off 
Exit Code: 0
Output:

2021-07-01 13:32:04 (7888): 
Command: VBoxManage -q modifyvm "boinc_f2713dce885fccc6" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2021-07-01 13:32:05 (7888): 
Command: VBoxManage -q modifyvm "boinc_f2713dce885fccc6" --audio none 
Exit Code: 0
Output:

2021-07-01 13:32:05 (7888): 
Command: VBoxManage -q modifyvm "boinc_f2713dce885fccc6" --clipboard disabled 
Exit Code: 0
Output:

2021-07-01 13:32:05 (7888): 
Command: VBoxManage -q modifyvm "boinc_f2713dce885fccc6" --draganddrop disabled 
Exit Code: 0
Output:

2021-07-01 13:32:06 (7888): 
Command: VBoxManage -q storagectl "boinc_f2713dce885fccc6" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2021-07-01 13:32:06 (7888): 
Command: VBoxManage -q storageattach "boinc_f2713dce885fccc6" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\ProgramData\BOINC\slots\6/vm_isocontext.iso" 
Exit Code: 0
Output:

2021-07-01 13:32:06 (7888): 
Command: VBoxManage -q storageattach "boinc_f2713dce885fccc6" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2021-07-01 13:32:06 (7888): 
Command: VBoxManage -q bandwidthctl "boinc_f2713dce885fccc6" add "boinc_f2713dce885fccc6_net" --type network --limit 1024G 
Exit Code: 0
Output:

2021-07-01 13:32:07 (7888): 
Command: VBoxManage -q sharedfolder add "boinc_f2713dce885fccc6" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\6/shared"
Exit Code: 0
Output:

2021-07-01 13:32:08 (7888): 
Command: VBoxManage -q startvm "boinc_f2713dce885fccc6" --type headless
Exit Code: -2147467259
Output:
Waiting for VM "boinc_f2713dce885fccc6" to power on...
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: AMD-V is disabled in the BIOS (or by the host OS) (VERR_SVM_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole

2021-07-01 13:32:09 (7888): 
Command: VBoxManage -q snapshot "boinc_f2713dce885fccc6" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2021-07-01 13:32:09 (7888): 
Command: VBoxManage -q bandwidthctl "boinc_f2713dce885fccc6" remove "boinc_f2713dce885fccc6_net" 
Exit Code: 0
Output:
VBoxManage.exe: error: Bandwidth groups cannot be deleted while the VM is running

2021-07-01 13:32:09 (7888): 
Command: VBoxManage -q unregistervm "boinc_f2713dce885fccc6" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

2021-07-01 13:32:09 (7888): 
Command: VBoxManage -q closemedium dvd "C:\ProgramData\BOINC\slots\6/vm_isocontext.iso" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

13:32:14 (7888): called boinc_finish(-2147467259)

</stderr_txt>
]]>


©2024 COPYRIGHT 2017-2018 NCN