Task 10894609

Name 08391266_095_0
Workunit 8468825
Created 2 Jul 2021, 11:43:26 UTC
Sent 3 Jul 2021, 4:53:15 UTC
Report deadline 8 Jul 2021, 4:53:15 UTC
Received 3 Jul 2021, 11:59:14 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status 1 (0x00000001) Unknown error code
Computer ID 4601
Run time 21 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 5.70 GFLOPS
Application version boinc2docker v1.14 (vbox64_mt)
windows_x86_64
Peak working set size 10.92 MB
Peak swap size 6.25 MB
Peak disk usage 499.86 MB

Stderr output

<core_client_version>7.16.11</core_client_version>
<![CDATA[
<message>
Funzione non corretta.
 (0x1) - exit code 1 (0x1)</message>
<stderr_txt>
2021-07-03 13:53:22 (114728): Detected: vboxwrapper 26202
2021-07-03 13:53:22 (114728): Detected: BOINC client v7.16.11
2021-07-03 13:53:23 (114728): Detected: VirtualBox VboxManage Interface (Version: 6.1.16)
2021-07-03 13:53:24 (114728): Create VM. (boinc_2885cec3f1859ba6, slot#9)
2021-07-03 13:53:24 (114728): Updating drive controller type and model for desired configuration.
2021-07-03 13:53:24 (114728): Setting Memory Size for VM. (3072MB)
2021-07-03 13:53:24 (114728): Setting CPU Count for VM. (1)
2021-07-03 13:53:25 (114728): Setting Chipset Options for VM.
2021-07-03 13:53:25 (114728): Setting Boot Options for VM.
2021-07-03 13:53:25 (114728): Setting Network Configuration for NAT.
2021-07-03 13:53:26 (114728): Enabling VM Network Access.
2021-07-03 13:53:26 (114728): Disabling USB Support for VM.
2021-07-03 13:53:26 (114728): Disabling COM Port Support for VM.
2021-07-03 13:53:26 (114728): Disabling LPT Port Support for VM.
2021-07-03 13:53:27 (114728): Disabling Audio Support for VM.
2021-07-03 13:53:27 (114728): Disabling Clipboard Support for VM.
2021-07-03 13:53:27 (114728): Disabling Drag and Drop Support for VM.
2021-07-03 13:53:27 (114728): Adding storage controller(s) to VM.
2021-07-03 13:53:28 (114728): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso)
2021-07-03 13:53:28 (114728): Adding VirtualBox Guest Additions to VM.
2021-07-03 13:53:28 (114728): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2021-07-03 13:53:28 (114728): Enabling shared directory for VM.
2021-07-03 13:53:29 (114728): Starting VM using VBoxManage interface. (boinc_2885cec3f1859ba6, slot#9)
2021-07-03 13:53:30 (114728): Error in start VM for VM: 1
Command:
VBoxManage -q startvm "boinc_2885cec3f1859ba6" --type headless
Output:
Waiting for VM "boinc_2885cec3f1859ba6" to power on...
VBoxManage.exe: error: The virtual machine 'boinc_2885cec3f1859ba6' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\9\boinc_2885cec3f1859ba6\Logs\VBoxHardening.log'
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine

2021-07-03 13:53:30 (114728): VM failed to start.
2021-07-03 13:53:30 (114728): Could not start 
2021-07-03 13:53:30 (114728): ERROR: VM failed to start
2021-07-03 13:53:30 (114728): Powering off VM.
2021-07-03 13:53:30 (114728): Deregistering VM. (boinc_2885cec3f1859ba6, slot#9)
2021-07-03 13:53:31 (114728): Removing network bandwidth throttle group from VM.
2021-07-03 13:53:31 (114728): Removing VM from VirtualBox.
2021-07-03 13:53:31 (114728): Removing virtual ISO 9660 disk from VirtualBox.

    Hypervisor System Log:

00:00:06.725213          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.730030          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:06.738828          Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_243abb6d2db38209\boinc_243abb6d2db38209.vbox" with version "1.16-windows"
00:00:06.802427          Launched VM: 76211760 pid: 119124 (0x1d154) frontend: headless name: boinc_0d79ef60453a89f1
00:00:06.804626          Saving settings file "C:\ProgramData\BOINC\slots\9\boinc_2885cec3f1859ba6\boinc_2885cec3f1859ba6.vbox" with version "1.16-windows"
00:00:06.842933          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.843076          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.847965          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:06.862447          Launched VM: 75685584 pid: 99500 (0x184ac) frontend: headless name: boinc_f1e2fa0ce418bd24
00:00:06.983676          Launched VM: 81974576 pid: 102768 (0x19170) frontend: headless name: boinc_11abcdc9ece6c7e0
00:00:06.985641          Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_270bd421f552c9fc\boinc_270bd421f552c9fc.vbox" with version "1.16-windows"
00:00:07.009579          Launched VM: 82111568 pid: 115200 (0x1c200) frontend: headless name: boinc_e38d88d48fc6c07a
00:00:07.028620          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.028723          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.033750          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:07.062877          Saving settings file "C:\ProgramData\BOINC\slots\9\boinc_2885cec3f1859ba6\boinc_2885cec3f1859ba6.vbox" with version "1.16-windows"
00:00:07.115596          Launched VM: 76177248 pid: 114172 (0x1bdfc) frontend: headless name: boinc_11f08f29a9e287ce
00:00:07.235033          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.235174          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.239640          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:07.282931          Launched VM: 76214928 pid: 98104 (0x17f38) frontend: headless name: boinc_243abb6d2db38209
00:00:07.332216          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.332315          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:07.337223          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:07.505865          Launched VM: 82154176 pid: 117556 (0x1cb34) frontend: headless name: boinc_270bd421f552c9fc
00:00:07.603572          Launched VM: 75683616 pid: 115548 (0x1c35c) frontend: headless name: boinc_2885cec3f1859ba6
00:00:08.524120 Watcher  ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={The virtual machine 'boinc_11f08f29a9e287ce' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\6\boinc_11f08f29a9e287ce\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0
00:00:08.524423 Watcher  Reaper: Pid 114172 (1bdfc) exited normally: 1 (0x1)
00:00:08.568909          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:08.611010          Saving settings file "C:\ProgramData\BOINC\slots\6\boinc_11f08f29a9e287ce\boinc_11f08f29a9e287ce.vbox" with version "1.16-windows"
00:00:08.891116          Saving settings file "C:\Users\DADO\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:08.958933 Watcher  ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={The virtual machine 'boinc_2885cec3f1859ba6' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\9\boinc_2885cec3f1859ba6\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0
00:00:08.961062 Watcher  Reaper: Pid 115548 (1c35c) exited normally: 1 (0x1)
00:00:09.019206          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:09.078641          Saving settings file "C:\ProgramData\BOINC\slots\9\boinc_2885cec3f1859ba6\boinc_2885cec3f1859ba6.vbox" with version "1.16-windows"
00:00:09.335912          Saving settings file "C:\Users\DADO\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:11.259491          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_f1e2fa0ce418bd24\boinc_f1e2fa0ce418bd24.vbox" with version "1.16-windows"
00:00:11.264730          Saving settings file "C:\ProgramData\BOINC\slots\4\boinc_0d79ef60453a89f1\boinc_0d79ef60453a89f1.vbox" with version "1.16-windows"
00:00:11.376887          Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_11abcdc9ece6c7e0\boinc_11abcdc9ece6c7e0.vbox" with version "1.16-windows"
00:00:11.409149          Saving settings file "C:\ProgramData\BOINC\slots\2\boinc_e38d88d48fc6c07a\boinc_e38d88d48fc6c07a.vbox" with version "1.16-windows"
00:00:11.643172          Saving settings file "C:\ProgramData\BOINC\slots\7\boinc_243abb6d2db38209\boinc_243abb6d2db38209.vbox" with version "1.16-windows"
00:00:11.906093          Saving settings file "C:\ProgramData\BOINC\slots\8\boinc_270bd421f552c9fc\boinc_270bd421f552c9fc.vbox" with version "1.16-windows"

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

9 Controllers:   8
Maximum NVMe Port count:         255
Maximum Devices per NVMe Port:   1
Maximum virtio-scsi PIIX3 Controllers:  1
Maximum virtio-scsi ICH9 Controllers:   8
Maximum virtio-scsi Port count:         256
Maximum Devices per virtio-scsi Port:   1
Maximum PIIX3 Floppy Controllers:1
Maximum ICH9 Floppy Controllers: 1
Maximum Floppy Port count:       1
Maximum Devices per Floppy Port: 2
Default machine folder:          C:\Users\DADO\VirtualBox VMs
Raw-mode Supported:              no
Exclusive HW virtualization use: off
Default hard disk format:        VDI
VRDE auth library:               VBoxAuth
Webservice auth. library:        VBoxAuth
Remote desktop ExtPack:          Oracle VM VirtualBox Extension Pack
Log history count:               3
Default frontend:                
Default audio driver:            DirectSound
Autostart database path:         
Default Guest Additions ISO:     C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso
Logging Level:                   all
Proxy Mode:                      System
Proxy URL:                       

2021-07-03 13:53:23 (114728): 
Command: VBoxManage -q list hostinfo 
Exit Code: 0
Output:
Host Information:

Host time: 2021-07-03T11:53:23.399000000Z
Processor online count: 8
Processor count: 8
Processor online core count: 8
Processor core count: 8
Processor supports HW virtualization: yes
Processor supports PAE: yes
Processor supports long mode: yes
Processor supports nested paging: yes
Processor supports unrestricted guest: yes
Processor supports nested HW virtualization: yes
Processor#0 speed: unknown
Processor#0 description: Intel(R) Core(TM) i7-9700K CPU @ 3.60GHz
Processor#1 speed: unknown
Processor#1 description: Intel(R) Core(TM) i7-9700K CPU @ 3.60GHz
Processor#2 speed: unknown
Processor#2 description: Intel(R) Core(TM) i7-9700K CPU @ 3.60GHz
Processor#3 speed: unknown
Processor#3 description: Intel(R) Core(TM) i7-9700K CPU @ 3.60GHz
Processor#4 speed: unknown
Processor#4 description: Intel(R) Core(TM) i7-9700K CPU @ 3.60GHz
Processor#5 speed: unknown
Processor#5 description: Intel(R) Core(TM) i7-9700K CPU @ 3.60GHz
Processor#6 speed: unknown
Processor#6 description: Intel(R) Core(TM) i7-9700K CPU @ 3.60GHz
Processor#7 speed: unknown
Processor#7 description: Intel(R) Core(TM) i7-9700K CPU @ 3.60GHz
Memory size: 32683 MByte
Memory available: 22406 MByte
Operating system: Windows 10
Operating system version: 10.0.19043

2021-07-03 13:53:23 (114728): 
Command: VBoxManage -q showvminfo "boinc_2885cec3f1859ba6" --machinereadable 
Exit Code: -2135228415
Output:
VBoxManage.exe: error: Could not find a registered machine named 'boinc_2885cec3f1859ba6'
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown
VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2715 of file VBoxManageInfo.cpp

2021-07-03 13:53:24 (114728): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\9/vm_image.vdi" 
Exit Code: -2135228412
Output:
VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\9\vm_image.vdi' (VERR_FILE_NOT_FOUND)
VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp

2021-07-03 13:53:24 (114728): 
Command: VBoxManage -q createvm --name "boinc_2885cec3f1859ba6" --basefolder "C:\ProgramData\BOINC\slots\9" --ostype "Linux26_64" --register
Exit Code: 0
Output:
Virtual machine 'boinc_2885cec3f1859ba6' is created and registered.
UUID: 2dde75fc-c382-4343-a307-c7601dc35a08
Settings file: 'C:\ProgramData\BOINC\slots\9\boinc_2885cec3f1859ba6\boinc_2885cec3f1859ba6.vbox'

2021-07-03 13:53:24 (114728): 
Command: VBoxManage -q modifyvm "boinc_2885cec3f1859ba6" --description "08391266_095_0" 
Exit Code: 0
Output:

2021-07-03 13:53:24 (114728): 
Command: VBoxManage -q modifyvm "boinc_2885cec3f1859ba6" --memory 3072 
Exit Code: 0
Output:

2021-07-03 13:53:25 (114728): 
Command: VBoxManage -q modifyvm "boinc_2885cec3f1859ba6" --cpus 1 
Exit Code: 0
Output:

2021-07-03 13:53:25 (114728): 
Command: VBoxManage -q modifyvm "boinc_2885cec3f1859ba6" --acpi on --ioapic on 
Exit Code: 0
Output:

2021-07-03 13:53:25 (114728): 
Command: VBoxManage -q modifyvm "boinc_2885cec3f1859ba6" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2021-07-03 13:53:26 (114728): 
Command: VBoxManage -q modifyvm "boinc_2885cec3f1859ba6" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2021-07-03 13:53:26 (114728): 
Command: VBoxManage -q modifyvm "boinc_2885cec3f1859ba6" --cableconnected1 on 
Exit Code: 0
Output:

2021-07-03 13:53:26 (114728): 
Command: VBoxManage -q modifyvm "boinc_2885cec3f1859ba6" --usb off 
Exit Code: 0
Output:

2021-07-03 13:53:26 (114728): 
Command: VBoxManage -q modifyvm "boinc_2885cec3f1859ba6" --uart1 off --uart2 off 
Exit Code: 0
Output:

2021-07-03 13:53:27 (114728): 
Command: VBoxManage -q modifyvm "boinc_2885cec3f1859ba6" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2021-07-03 13:53:27 (114728): 
Command: VBoxManage -q modifyvm "boinc_2885cec3f1859ba6" --audio none 
Exit Code: 0
Output:

2021-07-03 13:53:27 (114728): 
Command: VBoxManage -q modifyvm "boinc_2885cec3f1859ba6" --clipboard disabled 
Exit Code: 0
Output:

2021-07-03 13:53:27 (114728): 
Command: VBoxManage -q modifyvm "boinc_2885cec3f1859ba6" --draganddrop disabled 
Exit Code: 0
Output:

2021-07-03 13:53:28 (114728): 
Command: VBoxManage -q storagectl "boinc_2885cec3f1859ba6" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2021-07-03 13:53:28 (114728): 
Command: VBoxManage -q storageattach "boinc_2885cec3f1859ba6" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\ProgramData\BOINC\slots\9/vm_isocontext.iso" 
Exit Code: 0
Output:

2021-07-03 13:53:28 (114728): 
Command: VBoxManage -q storageattach "boinc_2885cec3f1859ba6" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2021-07-03 13:53:28 (114728): 
Command: VBoxManage -q bandwidthctl "boinc_2885cec3f1859ba6" add "boinc_2885cec3f1859ba6_net" --type network --limit 1024G 
Exit Code: 0
Output:

2021-07-03 13:53:29 (114728): 
Command: VBoxManage -q sharedfolder add "boinc_2885cec3f1859ba6" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\9/shared"
Exit Code: 0
Output:

2021-07-03 13:53:30 (114728): 
Command: VBoxManage -q startvm "boinc_2885cec3f1859ba6" --type headless
Exit Code: 1
Output:
Waiting for VM "boinc_2885cec3f1859ba6" to power on...
VBoxManage.exe: error: The virtual machine 'boinc_2885cec3f1859ba6' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\9\boinc_2885cec3f1859ba6\Logs\VBoxHardening.log'
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine

2021-07-03 13:53:31 (114728): 
Command: VBoxManage -q snapshot "boinc_2885cec3f1859ba6" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2021-07-03 13:53:31 (114728): 
Command: VBoxManage -q bandwidthctl "boinc_2885cec3f1859ba6" remove "boinc_2885cec3f1859ba6_net" 
Exit Code: 0
Output:

2021-07-03 13:53:31 (114728): 
Command: VBoxManage -q unregistervm "boinc_2885cec3f1859ba6" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

2021-07-03 13:53:31 (114728): 
Command: VBoxManage -q closemedium dvd "C:\ProgramData\BOINC\slots\9/vm_isocontext.iso" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

13:53:41 (114728): called boinc_finish(1)

</stderr_txt>
]]>


©2024 COPYRIGHT 2017-2018 NCN