Name | 08396242_05_0 |
Workunit | 8533795 |
Created | 8 Jul 2021, 9:17:31 UTC |
Sent | 8 Jul 2021, 23:26:38 UTC |
Report deadline | 13 Jul 2021, 23:26:38 UTC |
Received | 13 Jul 2021, 6:30:04 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | -2147467259 (0x80004005) Unknown error code |
Computer ID | 12083 |
Run time | 24 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 2.99 GFLOPS |
Application version | boinc2docker v1.14 (vbox64_mt) windows_x86_64 |
Peak working set size | 10.76 MB |
Peak swap size | 6.43 MB |
Peak disk usage | 227.37 MB |
<core_client_version>7.16.11</core_client_version> <![CDATA[ <message> Unspecified error (0x80004005) - exit code 2147500037 (0x80004005)</message> <stderr_txt> 2021-07-08 17:27:06 (20064): Detected: vboxwrapper 26202 2021-07-08 17:27:06 (20064): Detected: BOINC client v7.16.11 2021-07-08 17:27:07 (20064): Detected: VirtualBox VboxManage Interface (Version: 6.1.12) 2021-07-08 17:27:08 (20064): Create VM. (boinc_57ab648fd86a65d6, slot#1) 2021-07-08 17:27:08 (20064): Updating drive controller type and model for desired configuration. 2021-07-08 17:27:09 (20064): Setting Memory Size for VM. (3072MB) 2021-07-08 17:27:09 (20064): Setting CPU Count for VM. (1) 2021-07-08 17:27:10 (20064): Setting Chipset Options for VM. 2021-07-08 17:27:11 (20064): Setting Boot Options for VM. 2021-07-08 17:27:12 (20064): Setting Network Configuration for NAT. 2021-07-08 17:27:13 (20064): Enabling VM Network Access. 2021-07-08 17:27:14 (20064): Disabling USB Support for VM. 2021-07-08 17:27:14 (20064): Disabling COM Port Support for VM. 2021-07-08 17:27:15 (20064): Disabling LPT Port Support for VM. 2021-07-08 17:27:15 (20064): Disabling Audio Support for VM. 2021-07-08 17:27:15 (20064): Disabling Clipboard Support for VM. 2021-07-08 17:27:15 (20064): Disabling Drag and Drop Support for VM. 2021-07-08 17:27:16 (20064): Adding storage controller(s) to VM. 2021-07-08 17:27:16 (20064): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso) 2021-07-08 17:27:16 (20064): Adding VirtualBox Guest Additions to VM. 2021-07-08 17:27:16 (20064): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2021-07-08 17:27:17 (20064): Enabling shared directory for VM. 2021-07-08 17:27:17 (20064): Starting VM using VBoxManage interface. (boinc_57ab648fd86a65d6, slot#1) 2021-07-08 17:27:21 (20064): Error in start VM for VM: -2147467259 Command: VBoxManage -q startvm "boinc_57ab648fd86a65d6" --type headless Output: Waiting for VM "boinc_57ab648fd86a65d6" to power on... VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2021-07-08 17:27:21 (20064): VM failed to start. 2021-07-08 17:27:21 (20064): Could not start 2021-07-08 17:27:21 (20064): ERROR: VM failed to start 2021-07-08 17:27:21 (20064): Powering off VM. 2021-07-08 17:27:21 (20064): Deregistering VM. (boinc_57ab648fd86a65d6, slot#1) 2021-07-08 17:27:21 (20064): Removing network bandwidth throttle group from VM. 2021-07-08 17:27:21 (20064): Removing VM from VirtualBox. 2021-07-08 17:27:22 (20064): Removing virtual ISO 9660 disk from VirtualBox. Hypervisor System Log: 00:00:09.659602 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_e437d5c2392dab0f\boinc_e437d5c2392dab0f.vbox" with version "1.16-windows" 00:00:09.660913 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_57ab648fd86a65d6\boinc_57ab648fd86a65d6.vbox" with version "1.16-windows" 00:00:09.863848 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.867166 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:09.867432 Saving settings file "C:\Users\emars\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:09.876547 Saving settings file "C:\Users\emars\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:09.883670 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_57ab648fd86a65d6\boinc_57ab648fd86a65d6.vbox" with version "1.16-windows" 00:00:09.900307 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_e437d5c2392dab0f\boinc_e437d5c2392dab0f.vbox" with version "1.16-windows" 00:00:10.155390 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_57ab648fd86a65d6\boinc_57ab648fd86a65d6.vbox" with version "1.16-windows" 00:00:10.197858 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_e437d5c2392dab0f\boinc_e437d5c2392dab0f.vbox" with version "1.16-windows" 00:00:10.430978 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_57ab648fd86a65d6\boinc_57ab648fd86a65d6.vbox" with version "1.16-windows" 00:00:10.679621 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_e437d5c2392dab0f\boinc_e437d5c2392dab0f.vbox" with version "1.16-windows" 00:00:10.681993 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:10.682188 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:10.695711 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:10.966162 Launched VM: 65585712 pid: 10264 (0x2818) frontend: headless name: boinc_57ab648fd86a65d6 00:00:10.971054 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_e437d5c2392dab0f\boinc_e437d5c2392dab0f.vbox" with version "1.16-windows" 00:00:11.194841 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_e437d5c2392dab0f\boinc_e437d5c2392dab0f.vbox" with version "1.16-windows" 00:00:11.489891 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:11.492457 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:11.492630 Saving settings file "C:\Users\emars\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:11.502329 Saving settings file "C:\Users\emars\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:11.524997 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_e437d5c2392dab0f\boinc_e437d5c2392dab0f.vbox" with version "1.16-windows" 00:00:11.732682 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:11.733225 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:11.733883 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_e437d5c2392dab0f\boinc_e437d5c2392dab0f.vbox" with version "1.16-windows" 00:00:11.982557 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_e437d5c2392dab0f\boinc_e437d5c2392dab0f.vbox" with version "1.16-windows" 00:00:12.263510 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_e437d5c2392dab0f\boinc_e437d5c2392dab0f.vbox" with version "1.16-windows" 00:00:12.524022 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:12.524235 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:12.535948 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:12.767899 Launched VM: 66046832 pid: 16844 (0x41cc) frontend: headless name: boinc_e437d5c2392dab0f 00:00:14.651349 Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_57ab648fd86a65d6\boinc_57ab648fd86a65d6.vbox" with version "1.16-windows" 00:00:14.765443 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:15.119245 Saving settings file "C:\Users\emars\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:16.444509 Saving settings file "C:\ProgramData\BOINC\slots\0\boinc_e437d5c2392dab0f\boinc_e437d5c2392dab0f.vbox" with version "1.16-windows" 00:00:16.549983 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:16.898131 ERROR [COM]: aRC=VBOX_E_INVALID_OBJECT_STATE (0x80bb0007) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={MachineWrap} aText={Cannot unregister the machine 'boinc_e437d5c2392dab0f' while it is locked}, preserve=false aResultDetail=0 00:00:18.171386 Saving settings file "C:\Users\emars\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:23.436541 main VirtualBox: object deletion starts 00:00:23.436714 main ERROR [COM]: aRC=VBOX_E_OBJECT_IN_USE (0x80bb000c) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Medium 'C:\Users\emars\VirtualBox VMs\Loveless16\Loveless16.vdi' cannot be closed because it is still attached to 1 virtual machines}, preserve=false aResultDetail=0 00:00:23.443707 main HostDnsMonitor: shutting down ... 00:00:23.444179 main HostDnsMonitor: shut down 00:00:23.453991 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:23.454667 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: um SATA Port count: 30 Maximum Devices per SATA Port: 1 Maximum PIIX3 SCSI Controllers: 1 Maximum ICH9 SCSI Controllers: 8 Maximum SCSI Port count: 16 Maximum Devices per SCSI Port: 1 Maximum SAS PIIX3 Controllers: 1 Maximum SAS ICH9 Controllers: 8 Maximum SAS Port count: 255 Maximum Devices per SAS Port: 1 Maximum NVMe PIIX3 Controllers: 1 Maximum NVMe ICH9 Controllers: 8 Maximum NVMe Port count: 255 Maximum Devices per NVMe Port: 1 Maximum virtio-scsi PIIX3 Controllers: 1 Maximum virtio-scsi ICH9 Controllers: 8 Maximum virtio-scsi Port count: 256 Maximum Devices per virtio-scsi Port: 1 Maximum PIIX3 Floppy Controllers:1 Maximum ICH9 Floppy Controllers: 1 Maximum Floppy Port count: 1 Maximum Devices per Floppy Port: 2 Default machine folder: C:\Users\emars\VirtualBox VMs Raw-mode Supported: no Exclusive HW virtualization use: off Default hard disk format: VDI VRDE auth library: VBoxAuth Webservice auth. library: VBoxAuth Remote desktop ExtPack: Log history count: 3 Default frontend: Default audio driver: DirectSound Autostart database path: Default Guest Additions ISO: C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso Logging Level: all Proxy Mode: System Proxy URL: 2021-07-08 17:27:07 (20064): Command: VBoxManage -q list hostinfo Exit Code: 0 Output: Host Information: Host time: 2021-07-08T23:27:07.590000000Z Processor online count: 4 Processor count: 4 Processor online core count: 2 Processor core count: 2 Processor supports HW virtualization: no Processor supports PAE: yes Processor supports long mode: yes Processor supports nested paging: no Processor supports unrestricted guest: no Processor supports nested HW virtualization: no Processor#0 speed: unknown Processor#0 description: Intel(R) Core(TM) i5-6200U CPU @ 2.30GHz Processor#1 speed: unknown Processor#1 description: Intel(R) Core(TM) i5-6200U CPU @ 2.30GHz Processor#2 speed: unknown Processor#2 description: Intel(R) Core(TM) i5-6200U CPU @ 2.30GHz Processor#3 speed: unknown Processor#3 description: Intel(R) Core(TM) i5-6200U CPU @ 2.30GHz Memory size: 8082 MByte Memory available: 3905 MByte Operating system: Windows 10 Operating system version: 10.0.18363 2021-07-08 17:27:08 (20064): Command: VBoxManage -q showvminfo "boinc_57ab648fd86a65d6" --machinereadable Exit Code: -2135228415 Output: VBoxManage.exe: error: Could not find a registered machine named 'boinc_57ab648fd86a65d6' VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2715 of file VBoxManageInfo.cpp 2021-07-08 17:27:08 (20064): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\1/vm_image.vdi" Exit Code: -2135228412 Output: VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\1\vm_image.vdi' (VERR_FILE_NOT_FOUND) VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp 2021-07-08 17:27:09 (20064): Command: VBoxManage -q createvm --name "boinc_57ab648fd86a65d6" --basefolder "C:\ProgramData\BOINC\slots\1" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_57ab648fd86a65d6' is created and registered. UUID: 4d7af618-a9f5-43a3-808c-a384f8fb944a Settings file: 'C:\ProgramData\BOINC\slots\1\boinc_57ab648fd86a65d6\boinc_57ab648fd86a65d6.vbox' 2021-07-08 17:27:09 (20064): Command: VBoxManage -q modifyvm "boinc_57ab648fd86a65d6" --description "08396242_05_0" Exit Code: 0 Output: 2021-07-08 17:27:09 (20064): Command: VBoxManage -q modifyvm "boinc_57ab648fd86a65d6" --memory 3072 Exit Code: 0 Output: 2021-07-08 17:27:10 (20064): Command: VBoxManage -q modifyvm "boinc_57ab648fd86a65d6" --cpus 1 Exit Code: 0 Output: 2021-07-08 17:27:11 (20064): Command: VBoxManage -q modifyvm "boinc_57ab648fd86a65d6" --acpi on --ioapic on Exit Code: 0 Output: 2021-07-08 17:27:12 (20064): Command: VBoxManage -q modifyvm "boinc_57ab648fd86a65d6" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2021-07-08 17:27:13 (20064): Command: VBoxManage -q modifyvm "boinc_57ab648fd86a65d6" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2021-07-08 17:27:14 (20064): Command: VBoxManage -q modifyvm "boinc_57ab648fd86a65d6" --cableconnected1 on Exit Code: 0 Output: 2021-07-08 17:27:14 (20064): Command: VBoxManage -q modifyvm "boinc_57ab648fd86a65d6" --usb off Exit Code: 0 Output: 2021-07-08 17:27:15 (20064): Command: VBoxManage -q modifyvm "boinc_57ab648fd86a65d6" --uart1 off --uart2 off Exit Code: 0 Output: 2021-07-08 17:27:15 (20064): Command: VBoxManage -q modifyvm "boinc_57ab648fd86a65d6" --lpt1 off --lpt2 off Exit Code: 0 Output: 2021-07-08 17:27:15 (20064): Command: VBoxManage -q modifyvm "boinc_57ab648fd86a65d6" --audio none Exit Code: 0 Output: 2021-07-08 17:27:15 (20064): Command: VBoxManage -q modifyvm "boinc_57ab648fd86a65d6" --clipboard disabled Exit Code: 0 Output: 2021-07-08 17:27:16 (20064): Command: VBoxManage -q modifyvm "boinc_57ab648fd86a65d6" --draganddrop disabled Exit Code: 0 Output: 2021-07-08 17:27:16 (20064): Command: VBoxManage -q storagectl "boinc_57ab648fd86a65d6" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2021-07-08 17:27:16 (20064): Command: VBoxManage -q storageattach "boinc_57ab648fd86a65d6" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\ProgramData\BOINC\slots\1/vm_isocontext.iso" Exit Code: 0 Output: 2021-07-08 17:27:16 (20064): Command: VBoxManage -q storageattach "boinc_57ab648fd86a65d6" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2021-07-08 17:27:17 (20064): Command: VBoxManage -q bandwidthctl "boinc_57ab648fd86a65d6" add "boinc_57ab648fd86a65d6_net" --type network --limit 1024G Exit Code: 0 Output: 2021-07-08 17:27:17 (20064): Command: VBoxManage -q sharedfolder add "boinc_57ab648fd86a65d6" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\1/shared" Exit Code: 0 Output: 2021-07-08 17:27:21 (20064): Command: VBoxManage -q startvm "boinc_57ab648fd86a65d6" --type headless Exit Code: -2147467259 Output: Waiting for VM "boinc_57ab648fd86a65d6" to power on... VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2021-07-08 17:27:21 (20064): Command: VBoxManage -q snapshot "boinc_57ab648fd86a65d6" list Exit Code: -108 Output: This machine does not have any snapshots 2021-07-08 17:27:21 (20064): Command: VBoxManage -q bandwidthctl "boinc_57ab648fd86a65d6" remove "boinc_57ab648fd86a65d6_net" Exit Code: 0 Output: VBoxManage.exe: error: Bandwidth groups cannot be deleted while the VM is running 2021-07-08 17:27:22 (20064): Command: VBoxManage -q unregistervm "boinc_57ab648fd86a65d6" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 2021-07-08 17:27:22 (20064): Command: VBoxManage -q closemedium dvd "C:\ProgramData\BOINC\slots\1/vm_isocontext.iso" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 17:27:30 (20064): called boinc_finish(-2147467259) </stderr_txt> ]]>
©2025 COPYRIGHT 2017-2018 NCN