Task 10997982

Name 08396248_14_0
Workunit 8534091
Created 8 Jul 2021, 9:18:36 UTC
Sent 9 Jul 2021, 0:02:56 UTC
Report deadline 14 Jul 2021, 0:02:56 UTC
Received 9 Jul 2021, 1:11:30 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status -2147467259 (0x80004005) Unknown error code
Computer ID 9169
Run time 19 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 1.00 GFLOPS
Application version boinc2docker v1.14 (vbox64_mt)
windows_x86_64
Peak working set size 10.31 MB
Peak swap size 6.38 MB
Peak disk usage 498.82 MB

Stderr output

<core_client_version>7.16.11</core_client_version>
<![CDATA[
<message>
Niet nader omschreven fout
 (0x80004005) - exit code 2147500037 (0x80004005)</message>
<stderr_txt>
2021-07-09 02:11:08 (21392): Detected: vboxwrapper 26202
2021-07-09 02:11:08 (21392): Detected: BOINC client v7.16.11
2021-07-09 02:11:09 (21392): Detected: VirtualBox VboxManage Interface (Version: 6.1.12)
2021-07-09 02:11:10 (21392): Create VM. (boinc_f694af689f3f5486, slot#3)
2021-07-09 02:11:10 (21392): Updating drive controller type and model for desired configuration.
2021-07-09 02:11:11 (21392): Setting Memory Size for VM. (3072MB)
2021-07-09 02:11:11 (21392): Setting CPU Count for VM. (1)
2021-07-09 02:11:11 (21392): Setting Chipset Options for VM.
2021-07-09 02:11:12 (21392): Setting Boot Options for VM.
2021-07-09 02:11:12 (21392): Setting Network Configuration for NAT.
2021-07-09 02:11:12 (21392): Enabling VM Network Access.
2021-07-09 02:11:12 (21392): Disabling USB Support for VM.
2021-07-09 02:11:13 (21392): Disabling COM Port Support for VM.
2021-07-09 02:11:13 (21392): Disabling LPT Port Support for VM.
2021-07-09 02:11:13 (21392): Disabling Audio Support for VM.
2021-07-09 02:11:13 (21392): Disabling Clipboard Support for VM.
2021-07-09 02:11:14 (21392): Disabling Drag and Drop Support for VM.
2021-07-09 02:11:14 (21392): Adding storage controller(s) to VM.
2021-07-09 02:11:14 (21392): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso)
2021-07-09 02:11:15 (21392): Adding VirtualBox Guest Additions to VM.
2021-07-09 02:11:15 (21392): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2021-07-09 02:11:15 (21392): Enabling shared directory for VM.
2021-07-09 02:11:16 (21392): Starting VM using VBoxManage interface. (boinc_f694af689f3f5486, slot#3)
2021-07-09 02:11:19 (21392): Error in start VM for VM: -2147467259
Command:
VBoxManage -q startvm "boinc_f694af689f3f5486" --type headless
Output:
Waiting for VM "boinc_f694af689f3f5486" to power on...
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole

2021-07-09 02:11:19 (21392): VM failed to start.
2021-07-09 02:11:19 (21392): Could not start 
2021-07-09 02:11:19 (21392): ERROR: VM failed to start
2021-07-09 02:11:19 (21392): Powering off VM.
2021-07-09 02:11:19 (21392): Deregistering VM. (boinc_f694af689f3f5486, slot#3)
2021-07-09 02:11:19 (21392): Removing network bandwidth throttle group from VM.
2021-07-09 02:11:19 (21392): Removing VM from VirtualBox.
2021-07-09 02:11:19 (21392): Removing virtual ISO 9660 disk from VirtualBox.

    Hypervisor System Log:

00:00:00.241722          USB: Unknown USB device detected (idVendor: 0x8087, idProduct: 0x0a2a)
00:00:00.364958          HostDnsMonitor: initializing
00:00:00.381349          HostDnsMonitor: updating information
00:00:00.381378          HostDnsMonitor: old information
00:00:00.381379            no server entries
00:00:00.381381            no domain set
00:00:00.381381            no search string entries
00:00:00.381382          HostDnsMonitor: new information
00:00:00.381382            server 1: 192.168.2.254
00:00:00.381383            server 2: 195.121.1.34
00:00:00.381384            server 3: 195.121.1.66
00:00:00.381384            server 4: 100.120.77.1
00:00:00.381385            domain: blomkema
00:00:00.381385            no search string entries
00:00:00.495068          SUPR0QueryVTCaps -> VERR_VMX_MSR_ALL_VMX_DISABLED
00:00:00.495739          VD: VDInit finished with VINF_SUCCESS
00:00:00.497476          VirtualBox: object created
00:00:01.005861          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={Could not find a registered machine named 'boinc_f694af689f3f5486'}, preserve=false aResultDetail=0
00:00:01.288036          ERROR [COM]: aRC=VBOX_E_FILE_ERROR (0x80bb0004) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Could not find file for the medium 'C:\ProgramData\BOINC\slots\3\vm_image.vdi' (VERR_FILE_NOT_FOUND)}, preserve=false aResultDetail=-102
00:00:01.555832          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_f694af689f3f5486\boinc_f694af689f3f5486.vbox" with version "1.16-windows"
00:00:01.558706          Saving settings file "C:\Users\studi\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:01.828083          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_f694af689f3f5486\boinc_f694af689f3f5486.vbox" with version "1.16-windows"
00:00:02.098725          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_f694af689f3f5486\boinc_f694af689f3f5486.vbox" with version "1.16-windows"
00:00:02.365085          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_f694af689f3f5486\boinc_f694af689f3f5486.vbox" with version "1.16-windows"
00:00:02.634031          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_f694af689f3f5486\boinc_f694af689f3f5486.vbox" with version "1.16-windows"
00:00:02.910197          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_f694af689f3f5486\boinc_f694af689f3f5486.vbox" with version "1.16-windows"
00:00:03.181053          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_f694af689f3f5486\boinc_f694af689f3f5486.vbox" with version "1.16-windows"
00:00:03.453460          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_f694af689f3f5486\boinc_f694af689f3f5486.vbox" with version "1.16-windows"
00:00:03.715634          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_f694af689f3f5486\boinc_f694af689f3f5486.vbox" with version "1.16-windows"
00:00:03.984487          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_f694af689f3f5486\boinc_f694af689f3f5486.vbox" with version "1.16-windows"
00:00:04.253892          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_f694af689f3f5486\boinc_f694af689f3f5486.vbox" with version "1.16-windows"
00:00:04.525532          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_f694af689f3f5486\boinc_f694af689f3f5486.vbox" with version "1.16-windows"
00:00:04.796853          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_f694af689f3f5486\boinc_f694af689f3f5486.vbox" with version "1.16-windows"
00:00:05.068537          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_f694af689f3f5486\boinc_f694af689f3f5486.vbox" with version "1.16-windows"
00:00:05.342389          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_f694af689f3f5486\boinc_f694af689f3f5486.vbox" with version "1.16-windows"
00:00:05.615443          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:05.617809          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:05.618003          Saving settings file "C:\Users\studi\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:05.625540          Saving settings file "C:\Users\studi\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:05.629621          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_f694af689f3f5486\boinc_f694af689f3f5486.vbox" with version "1.16-windows"
00:00:05.878899          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:05.880975          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:05.881185          Saving settings file "C:\Users\studi\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:05.889456          Saving settings file "C:\Users\studi\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:05.894008          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_f694af689f3f5486\boinc_f694af689f3f5486.vbox" with version "1.16-windows"
00:00:06.153584          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_f694af689f3f5486\boinc_f694af689f3f5486.vbox" with version "1.16-windows"
00:00:06.416466          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_f694af689f3f5486\boinc_f694af689f3f5486.vbox" with version "1.16-windows"
00:00:06.692797          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.693004          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:06.706495          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:06.972497          Launched VM: 63107536 pid: 2580 (0xa14) frontend: headless name: boinc_f694af689f3f5486
00:00:09.934449          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_f694af689f3f5486\boinc_f694af689f3f5486.vbox" with version "1.16-windows"
00:00:10.048991          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:10.428391          Saving settings file "C:\Users\studi\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:13.078702 dns-monitor HostDnsMonitor: updating information
00:00:13.078731 dns-monitor HostDnsMonitor: unchanged
00:00:15.707383 main     VirtualBox: object deletion starts
00:00:15.708415 main     HostDnsMonitor: shutting down ...
00:00:15.708454 main     HostDnsMonitor: shut down
00:00:15.710766 Watcher  ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0
00:00:15.711045 main     VirtualBox: object deleted

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

m SATA Port count:         30
Maximum Devices per SATA Port:   1
Maximum PIIX3 SCSI Controllers:  1
Maximum ICH9 SCSI Controllers:   8
Maximum SCSI Port count:         16
Maximum Devices per SCSI Port:   1
Maximum SAS PIIX3 Controllers:   1
Maximum SAS ICH9 Controllers:    8
Maximum SAS Port count:          255
Maximum Devices per SAS Port:    1
Maximum NVMe PIIX3 Controllers:  1
Maximum NVMe ICH9 Controllers:   8
Maximum NVMe Port count:         255
Maximum Devices per NVMe Port:   1
Maximum virtio-scsi PIIX3 Controllers:  1
Maximum virtio-scsi ICH9 Controllers:   8
Maximum virtio-scsi Port count:         256
Maximum Devices per virtio-scsi Port:   1
Maximum PIIX3 Floppy Controllers:1
Maximum ICH9 Floppy Controllers: 1
Maximum Floppy Port count:       1
Maximum Devices per Floppy Port: 2
Default machine folder:          C:\Users\studi\VirtualBox VMs
Raw-mode Supported:              no
Exclusive HW virtualization use: off
Default hard disk format:        VDI
VRDE auth library:               VBoxAuth
Webservice auth. library:        VBoxAuth
Remote desktop ExtPack:          
Log history count:               3
Default frontend:                
Default audio driver:            DirectSound
Autostart database path:         
Default Guest Additions ISO:     C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso
Logging Level:                   all
Proxy Mode:                      System
Proxy URL:                       

2021-07-09 02:11:10 (21392): 
Command: VBoxManage -q list hostinfo 
Exit Code: 0
Output:
Host Information:

Host time: 2021-07-09T00:11:09.994000000Z
Processor online count: 4
Processor count: 4
Processor online core count: 4
Processor core count: 4
Processor supports HW virtualization: no
Processor supports PAE: yes
Processor supports long mode: yes
Processor supports nested paging: no
Processor supports unrestricted guest: no
Processor supports nested HW virtualization: no
Processor#0 speed: unknown
Processor#0 description: Intel(R) Core(TM) i5-6500T CPU @ 2.50GHz
Processor#1 speed: unknown
Processor#1 description: Intel(R) Core(TM) i5-6500T CPU @ 2.50GHz
Processor#2 speed: unknown
Processor#2 description: Intel(R) Core(TM) i5-6500T CPU @ 2.50GHz
Processor#3 speed: unknown
Processor#3 description: Intel(R) Core(TM) i5-6500T CPU @ 2.50GHz
Memory size: 12168 MByte
Memory available: 6249 MByte
Operating system: Windows 10
Operating system version: 10.0.19043

2021-07-09 02:11:10 (21392): 
Command: VBoxManage -q showvminfo "boinc_f694af689f3f5486" --machinereadable 
Exit Code: -2135228415
Output:
VBoxManage.exe: error: Could not find a registered machine named 'boinc_f694af689f3f5486'
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown
VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2715 of file VBoxManageInfo.cpp

2021-07-09 02:11:10 (21392): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\3/vm_image.vdi" 
Exit Code: -2135228412
Output:
VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\3\vm_image.vdi' (VERR_FILE_NOT_FOUND)
VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp

2021-07-09 02:11:10 (21392): 
Command: VBoxManage -q createvm --name "boinc_f694af689f3f5486" --basefolder "C:\ProgramData\BOINC\slots\3" --ostype "Linux26_64" --register
Exit Code: 0
Output:
Virtual machine 'boinc_f694af689f3f5486' is created and registered.
UUID: 8d540eb5-1d25-4c20-9a88-00fe08bf1427
Settings file: 'C:\ProgramData\BOINC\slots\3\boinc_f694af689f3f5486\boinc_f694af689f3f5486.vbox'

2021-07-09 02:11:11 (21392): 
Command: VBoxManage -q modifyvm "boinc_f694af689f3f5486" --description "08396248_14_0" 
Exit Code: 0
Output:

2021-07-09 02:11:11 (21392): 
Command: VBoxManage -q modifyvm "boinc_f694af689f3f5486" --memory 3072 
Exit Code: 0
Output:

2021-07-09 02:11:11 (21392): 
Command: VBoxManage -q modifyvm "boinc_f694af689f3f5486" --cpus 1 
Exit Code: 0
Output:

2021-07-09 02:11:12 (21392): 
Command: VBoxManage -q modifyvm "boinc_f694af689f3f5486" --acpi on --ioapic on 
Exit Code: 0
Output:

2021-07-09 02:11:12 (21392): 
Command: VBoxManage -q modifyvm "boinc_f694af689f3f5486" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2021-07-09 02:11:12 (21392): 
Command: VBoxManage -q modifyvm "boinc_f694af689f3f5486" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2021-07-09 02:11:12 (21392): 
Command: VBoxManage -q modifyvm "boinc_f694af689f3f5486" --cableconnected1 on 
Exit Code: 0
Output:

2021-07-09 02:11:13 (21392): 
Command: VBoxManage -q modifyvm "boinc_f694af689f3f5486" --usb off 
Exit Code: 0
Output:

2021-07-09 02:11:13 (21392): 
Command: VBoxManage -q modifyvm "boinc_f694af689f3f5486" --uart1 off --uart2 off 
Exit Code: 0
Output:

2021-07-09 02:11:13 (21392): 
Command: VBoxManage -q modifyvm "boinc_f694af689f3f5486" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2021-07-09 02:11:13 (21392): 
Command: VBoxManage -q modifyvm "boinc_f694af689f3f5486" --audio none 
Exit Code: 0
Output:

2021-07-09 02:11:14 (21392): 
Command: VBoxManage -q modifyvm "boinc_f694af689f3f5486" --clipboard disabled 
Exit Code: 0
Output:

2021-07-09 02:11:14 (21392): 
Command: VBoxManage -q modifyvm "boinc_f694af689f3f5486" --draganddrop disabled 
Exit Code: 0
Output:

2021-07-09 02:11:14 (21392): 
Command: VBoxManage -q storagectl "boinc_f694af689f3f5486" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2021-07-09 02:11:15 (21392): 
Command: VBoxManage -q storageattach "boinc_f694af689f3f5486" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\ProgramData\BOINC\slots\3/vm_isocontext.iso" 
Exit Code: 0
Output:

2021-07-09 02:11:15 (21392): 
Command: VBoxManage -q storageattach "boinc_f694af689f3f5486" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2021-07-09 02:11:15 (21392): 
Command: VBoxManage -q bandwidthctl "boinc_f694af689f3f5486" add "boinc_f694af689f3f5486_net" --type network --limit 1024G 
Exit Code: 0
Output:

2021-07-09 02:11:15 (21392): 
Command: VBoxManage -q sharedfolder add "boinc_f694af689f3f5486" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\3/shared"
Exit Code: 0
Output:

2021-07-09 02:11:19 (21392): 
Command: VBoxManage -q startvm "boinc_f694af689f3f5486" --type headless
Exit Code: -2147467259
Output:
Waiting for VM "boinc_f694af689f3f5486" to power on...
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole

2021-07-09 02:11:19 (21392): 
Command: VBoxManage -q snapshot "boinc_f694af689f3f5486" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2021-07-09 02:11:19 (21392): 
Command: VBoxManage -q bandwidthctl "boinc_f694af689f3f5486" remove "boinc_f694af689f3f5486_net" 
Exit Code: 0
Output:
VBoxManage.exe: error: Bandwidth groups cannot be deleted while the VM is running

2021-07-09 02:11:19 (21392): 
Command: VBoxManage -q unregistervm "boinc_f694af689f3f5486" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

2021-07-09 02:11:20 (21392): 
Command: VBoxManage -q closemedium dvd "C:\ProgramData\BOINC\slots\3/vm_isocontext.iso" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

02:11:26 (21392): called boinc_finish(-2147467259)

</stderr_txt>
]]>