Task 11007824

Name 08396711_29_0
Workunit 8542301
Created 8 Jul 2021, 22:02:12 UTC
Sent 9 Jul 2021, 16:21:18 UTC
Report deadline 14 Jul 2021, 16:21:18 UTC
Received 10 Jul 2021, 12:55:44 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status -2147467259 (0x80004005) Unknown error code
Computer ID 4935
Run time 20 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 2.96 GFLOPS
Application version boinc2docker v1.14 (vbox64_mt)
windows_x86_64
Peak working set size 10.28 MB
Peak swap size 6.21 MB
Peak disk usage 607.39 MB

Stderr output

<core_client_version>7.16.11</core_client_version>
<![CDATA[
<message>
Erreur non sp�cifi�e
 (0x80004005) - exit code 2147500037 (0x80004005)</message>
<stderr_txt>
2021-07-09 19:32:29 (2908): Detected: vboxwrapper 26202
2021-07-09 19:32:29 (2908): Detected: BOINC client v7.16.11
2021-07-09 19:32:32 (2908): Detected: VirtualBox VboxManage Interface (Version: 6.1.12)
2021-07-09 19:32:33 (2908): Create VM. (boinc_a81687abd4e1b11a, slot#3)
2021-07-09 19:32:33 (2908): Updating drive controller type and model for desired configuration.
2021-07-09 19:32:35 (2908): Setting Memory Size for VM. (3072MB)
2021-07-09 19:32:35 (2908): Setting CPU Count for VM. (1)
2021-07-09 19:32:35 (2908): Setting Chipset Options for VM.
2021-07-09 19:32:36 (2908): Setting Boot Options for VM.
2021-07-09 19:32:37 (2908): Setting Network Configuration for NAT.
2021-07-09 19:32:37 (2908): Enabling VM Network Access.
2021-07-09 19:32:37 (2908): Disabling USB Support for VM.
2021-07-09 19:32:38 (2908): Disabling COM Port Support for VM.
2021-07-09 19:32:38 (2908): Disabling LPT Port Support for VM.
2021-07-09 19:32:38 (2908): Disabling Audio Support for VM.
2021-07-09 19:32:39 (2908): Disabling Clipboard Support for VM.
2021-07-09 19:32:39 (2908): Disabling Drag and Drop Support for VM.
2021-07-09 19:32:40 (2908): Adding storage controller(s) to VM.
2021-07-09 19:32:40 (2908): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso)
2021-07-09 19:32:41 (2908): Adding VirtualBox Guest Additions to VM.
2021-07-09 19:32:41 (2908): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2021-07-09 19:32:42 (2908): Enabling shared directory for VM.
2021-07-09 19:32:42 (2908): Starting VM using VBoxManage interface. (boinc_a81687abd4e1b11a, slot#3)
2021-07-09 19:32:47 (2908): Error in start VM for VM: -2147467259
Command:
VBoxManage -q startvm "boinc_a81687abd4e1b11a" --type headless
Output:
Waiting for VM "boinc_a81687abd4e1b11a" to power on...
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole

2021-07-09 19:32:47 (2908): VM failed to start.
2021-07-09 19:32:47 (2908): Could not start 
2021-07-09 19:32:47 (2908): ERROR: VM failed to start
2021-07-09 19:32:47 (2908): Powering off VM.
2021-07-09 19:32:47 (2908): Deregistering VM. (boinc_a81687abd4e1b11a, slot#3)
2021-07-09 19:32:48 (2908): Removing network bandwidth throttle group from VM.
2021-07-09 19:32:48 (2908): Removing VM from VirtualBox.
2021-07-09 19:32:49 (2908): Removing virtual ISO 9660 disk from VirtualBox.

    Hypervisor System Log:

00:00:00.214831          usbLibGetDevices: Starting USB device enumeration
00:00:00.418567          usbLibGetDevices: Found 1 USB devices, 0 captured
00:00:00.916952          HostDnsMonitor: initializing
00:00:00.927223          HostDnsMonitor: updating information
00:00:00.927264          HostDnsMonitor: old information
00:00:00.927266            no server entries
00:00:00.927268            no domain set
00:00:00.927270            no search string entries
00:00:00.927271          HostDnsMonitor: new information
00:00:00.927273            server 1: 192.168.1.1
00:00:00.927274            domain: home
00:00:00.927276            no search string entries
00:00:01.070884          SUPR0QueryVTCaps -> VERR_VMX_MSR_ALL_VMX_DISABLED
00:00:01.071900          VD: VDInit finished with VINF_SUCCESS
00:00:01.074083          VirtualBox: object created
00:00:02.727231          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={Could not find a registered machine named 'boinc_a81687abd4e1b11a'}, preserve=false aResultDetail=0
00:00:03.004240          ERROR [COM]: aRC=VBOX_E_FILE_ERROR (0x80bb0004) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Could not find file for the medium 'C:\ProgramData\BOINC\slots\3\vm_image.vdi' (VERR_FILE_NOT_FOUND)}, preserve=false aResultDetail=-102
00:00:03.278237          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_a81687abd4e1b11a\boinc_a81687abd4e1b11a.vbox" with version "1.16-windows"
00:00:03.326935          Saving settings file "C:\Users\margu\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:04.068782          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_a81687abd4e1b11a\boinc_a81687abd4e1b11a.vbox" with version "1.16-windows"
00:00:04.549454          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_a81687abd4e1b11a\boinc_a81687abd4e1b11a.vbox" with version "1.16-windows"
00:00:05.094106          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_a81687abd4e1b11a\boinc_a81687abd4e1b11a.vbox" with version "1.16-windows"
00:00:05.496599          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_a81687abd4e1b11a\boinc_a81687abd4e1b11a.vbox" with version "1.16-windows"
00:00:06.034006          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_a81687abd4e1b11a\boinc_a81687abd4e1b11a.vbox" with version "1.16-windows"
00:00:06.541951          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_a81687abd4e1b11a\boinc_a81687abd4e1b11a.vbox" with version "1.16-windows"
00:00:06.932084          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_a81687abd4e1b11a\boinc_a81687abd4e1b11a.vbox" with version "1.16-windows"
00:00:07.323036          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_a81687abd4e1b11a\boinc_a81687abd4e1b11a.vbox" with version "1.16-windows"
00:00:07.610576          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_a81687abd4e1b11a\boinc_a81687abd4e1b11a.vbox" with version "1.16-windows"
00:00:08.020245          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_a81687abd4e1b11a\boinc_a81687abd4e1b11a.vbox" with version "1.16-windows"
00:00:08.360169          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_a81687abd4e1b11a\boinc_a81687abd4e1b11a.vbox" with version "1.16-windows"
00:00:08.700436          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_a81687abd4e1b11a\boinc_a81687abd4e1b11a.vbox" with version "1.16-windows"
00:00:09.259597          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_a81687abd4e1b11a\boinc_a81687abd4e1b11a.vbox" with version "1.16-windows"
00:00:09.823173          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_a81687abd4e1b11a\boinc_a81687abd4e1b11a.vbox" with version "1.16-windows"
00:00:10.347531          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:10.350385          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:10.350679          Saving settings file "C:\Users\margu\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:10.374512          Saving settings file "C:\Users\margu\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:10.395875          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_a81687abd4e1b11a\boinc_a81687abd4e1b11a.vbox" with version "1.16-windows"
00:00:10.704212          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:10.723965          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:10.724259          Saving settings file "C:\Users\margu\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:10.754785          Saving settings file "C:\Users\margu\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:10.773445          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_a81687abd4e1b11a\boinc_a81687abd4e1b11a.vbox" with version "1.16-windows"
00:00:11.221983          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_a81687abd4e1b11a\boinc_a81687abd4e1b11a.vbox" with version "1.16-windows"
00:00:11.609516          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_a81687abd4e1b11a\boinc_a81687abd4e1b11a.vbox" with version "1.16-windows"
00:00:11.966373          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:11.966608          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:11.978109          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:12.214299          Launched VM: 64067200 pid: 668 (0x29c) frontend: headless name: boinc_a81687abd4e1b11a
00:00:16.660996          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_a81687abd4e1b11a\boinc_a81687abd4e1b11a.vbox" with version "1.16-windows"
00:00:17.599020          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:17.932678          Saving settings file "C:\ProgramData\BOINC\slots\3\boinc_a81687abd4e1b11a\boinc_a81687abd4e1b11a.vbox" with version "1.16-windows"
00:00:18.455776          Saving settings file "C:\Users\margu\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:23.859784 main     VirtualBox: object deletion starts
00:00:23.867843 main     HostDnsMonitor: shutting down ...
00:00:23.867948 main     HostDnsMonitor: shut down
00:00:23.870476 Watcher  ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0
00:00:23.870778 main     VirtualBox: object deleted

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

rk Adapter count:   8
Maximum ICH9 Network Adapter count:   36
Maximum PIIX3 IDE Controllers:   1
Maximum ICH9 IDE Controllers:    1
Maximum IDE Port count:          2
Maximum Devices per IDE Port:    2
Maximum PIIX3 SATA Controllers:  1
Maximum ICH9 SATA Controllers:   8
Maximum SATA Port count:         30
Maximum Devices per SATA Port:   1
Maximum PIIX3 SCSI Controllers:  1
Maximum ICH9 SCSI Controllers:   8
Maximum SCSI Port count:         16
Maximum Devices per SCSI Port:   1
Maximum SAS PIIX3 Controllers:   1
Maximum SAS ICH9 Controllers:    8
Maximum SAS Port count:          255
Maximum Devices per SAS Port:    1
Maximum NVMe PIIX3 Controllers:  1
Maximum NVMe ICH9 Controllers:   8
Maximum NVMe Port count:         255
Maximum Devices per NVMe Port:   1
Maximum virtio-scsi PIIX3 Controllers:  1
Maximum virtio-scsi ICH9 Controllers:   8
Maximum virtio-scsi Port count:         256
Maximum Devices per virtio-scsi Port:   1
Maximum PIIX3 Floppy Controllers:1
Maximum ICH9 Floppy Controllers: 1
Maximum Floppy Port count:       1
Maximum Devices per Floppy Port: 2
Default machine folder:          C:\Users\margu\VirtualBox VMs
Raw-mode Supported:              no
Exclusive HW virtualization use: off
Default hard disk format:        VDI
VRDE auth library:               VBoxAuth
Webservice auth. library:        VBoxAuth
Remote desktop ExtPack:          
Log history count:               3
Default frontend:                
Default audio driver:            DirectSound
Autostart database path:         
Default Guest Additions ISO:     C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso
Logging Level:                   all
Proxy Mode:                      System
Proxy URL:                       

2021-07-09 19:32:33 (2908): 
Command: VBoxManage -q list hostinfo 
Exit Code: 0
Output:
Host Information:

Host time: 2021-07-09T17:32:32.824000000Z
Processor online count: 2
Processor count: 2
Processor online core count: 2
Processor core count: 2
Processor supports HW virtualization: no
Processor supports PAE: yes
Processor supports long mode: yes
Processor supports nested paging: no
Processor supports unrestricted guest: no
Processor supports nested HW virtualization: no
Processor#0 speed: unknown
Processor#0 description: Pentium(R) Dual-Core  CPU      E5300  @ 2.60GHz
Processor#1 speed: unknown
Processor#1 description: Pentium(R) Dual-Core  CPU      E5300  @ 2.60GHz
Memory size: 3963 MByte
Memory available: 1400 MByte
Operating system: Windows 10
Operating system version: 10.0.19043

2021-07-09 19:32:33 (2908): 
Command: VBoxManage -q showvminfo "boinc_a81687abd4e1b11a" --machinereadable 
Exit Code: -2135228415
Output:
VBoxManage.exe: error: Could not find a registered machine named 'boinc_a81687abd4e1b11a'
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown
VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2715 of file VBoxManageInfo.cpp

2021-07-09 19:32:33 (2908): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\3/vm_image.vdi" 
Exit Code: -2135228412
Output:
VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\3\vm_image.vdi' (VERR_FILE_NOT_FOUND)
VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp

2021-07-09 19:32:34 (2908): 
Command: VBoxManage -q createvm --name "boinc_a81687abd4e1b11a" --basefolder "C:\ProgramData\BOINC\slots\3" --ostype "Linux26_64" --register
Exit Code: 0
Output:
Virtual machine 'boinc_a81687abd4e1b11a' is created and registered.
UUID: dfe72cfa-835c-49a9-9a40-c2d8c1b28f49
Settings file: 'C:\ProgramData\BOINC\slots\3\boinc_a81687abd4e1b11a\boinc_a81687abd4e1b11a.vbox'

2021-07-09 19:32:34 (2908): 
Command: VBoxManage -q modifyvm "boinc_a81687abd4e1b11a" --description "08396711_29_0" 
Exit Code: 0
Output:

2021-07-09 19:32:35 (2908): 
Command: VBoxManage -q modifyvm "boinc_a81687abd4e1b11a" --memory 3072 
Exit Code: 0
Output:

2021-07-09 19:32:35 (2908): 
Command: VBoxManage -q modifyvm "boinc_a81687abd4e1b11a" --cpus 1 
Exit Code: 0
Output:

2021-07-09 19:32:36 (2908): 
Command: VBoxManage -q modifyvm "boinc_a81687abd4e1b11a" --acpi on --ioapic on 
Exit Code: 0
Output:

2021-07-09 19:32:37 (2908): 
Command: VBoxManage -q modifyvm "boinc_a81687abd4e1b11a" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2021-07-09 19:32:37 (2908): 
Command: VBoxManage -q modifyvm "boinc_a81687abd4e1b11a" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2021-07-09 19:32:37 (2908): 
Command: VBoxManage -q modifyvm "boinc_a81687abd4e1b11a" --cableconnected1 on 
Exit Code: 0
Output:

2021-07-09 19:32:38 (2908): 
Command: VBoxManage -q modifyvm "boinc_a81687abd4e1b11a" --usb off 
Exit Code: 0
Output:

2021-07-09 19:32:38 (2908): 
Command: VBoxManage -q modifyvm "boinc_a81687abd4e1b11a" --uart1 off --uart2 off 
Exit Code: 0
Output:

2021-07-09 19:32:38 (2908): 
Command: VBoxManage -q modifyvm "boinc_a81687abd4e1b11a" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2021-07-09 19:32:39 (2908): 
Command: VBoxManage -q modifyvm "boinc_a81687abd4e1b11a" --audio none 
Exit Code: 0
Output:

2021-07-09 19:32:39 (2908): 
Command: VBoxManage -q modifyvm "boinc_a81687abd4e1b11a" --clipboard disabled 
Exit Code: 0
Output:

2021-07-09 19:32:40 (2908): 
Command: VBoxManage -q modifyvm "boinc_a81687abd4e1b11a" --draganddrop disabled 
Exit Code: 0
Output:

2021-07-09 19:32:40 (2908): 
Command: VBoxManage -q storagectl "boinc_a81687abd4e1b11a" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2021-07-09 19:32:41 (2908): 
Command: VBoxManage -q storageattach "boinc_a81687abd4e1b11a" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\ProgramData\BOINC\slots\3/vm_isocontext.iso" 
Exit Code: 0
Output:

2021-07-09 19:32:41 (2908): 
Command: VBoxManage -q storageattach "boinc_a81687abd4e1b11a" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2021-07-09 19:32:42 (2908): 
Command: VBoxManage -q bandwidthctl "boinc_a81687abd4e1b11a" add "boinc_a81687abd4e1b11a_net" --type network --limit 1024G 
Exit Code: 0
Output:

2021-07-09 19:32:42 (2908): 
Command: VBoxManage -q sharedfolder add "boinc_a81687abd4e1b11a" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\3/shared"
Exit Code: 0
Output:

2021-07-09 19:32:47 (2908): 
Command: VBoxManage -q startvm "boinc_a81687abd4e1b11a" --type headless
Exit Code: -2147467259
Output:
Waiting for VM "boinc_a81687abd4e1b11a" to power on...
VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE).
VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED)
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole

2021-07-09 19:32:48 (2908): 
Command: VBoxManage -q snapshot "boinc_a81687abd4e1b11a" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2021-07-09 19:32:48 (2908): 
Command: VBoxManage -q bandwidthctl "boinc_a81687abd4e1b11a" remove "boinc_a81687abd4e1b11a_net" 
Exit Code: 0
Output:

2021-07-09 19:32:49 (2908): 
Command: VBoxManage -q unregistervm "boinc_a81687abd4e1b11a" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

2021-07-09 19:32:50 (2908): 
Command: VBoxManage -q closemedium dvd "C:\ProgramData\BOINC\slots\3/vm_isocontext.iso" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

19:32:56 (2908): called boinc_finish(-2147467259)

</stderr_txt>
]]>