Name | 08397597_36_0 |
Workunit | 8553289 |
Created | 10 Jul 2021, 0:01:19 UTC |
Sent | 10 Jul 2021, 13:14:48 UTC |
Report deadline | 15 Jul 2021, 13:14:48 UTC |
Received | 10 Jul 2021, 16:40:35 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | -2147467259 (0x80004005) Unknown error code |
Computer ID | 9800 |
Run time | 16 sec |
CPU time | |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 5.15 GFLOPS |
Application version | boinc2docker v1.14 (vbox64_mt) windows_x86_64 |
Peak working set size | 10.39 MB |
Peak swap size | 6.24 MB |
Peak disk usage | 239.34 MB |
<core_client_version>7.16.11</core_client_version> <![CDATA[ <message> Uspecificeret fejl (0x80004005) - exit code 2147500037 (0x80004005)</message> <stderr_txt> 2021-07-10 17:40:17 (2168): Detected: vboxwrapper 26202 2021-07-10 17:40:17 (2168): Detected: BOINC client v7.16.11 2021-07-10 17:40:17 (2168): Detected: VirtualBox VboxManage Interface (Version: 6.1.22) 2021-07-10 17:40:18 (2168): Create VM. (boinc_fd7c0c9c8b0d6e81, slot#5) 2021-07-10 17:40:18 (2168): Updating drive controller type and model for desired configuration. 2021-07-10 17:40:19 (2168): Setting Memory Size for VM. (3072MB) 2021-07-10 17:40:19 (2168): Setting CPU Count for VM. (1) 2021-07-10 17:40:19 (2168): Setting Chipset Options for VM. 2021-07-10 17:40:20 (2168): Setting Boot Options for VM. 2021-07-10 17:40:20 (2168): Setting Network Configuration for NAT. 2021-07-10 17:40:20 (2168): Enabling VM Network Access. 2021-07-10 17:40:20 (2168): Disabling USB Support for VM. 2021-07-10 17:40:21 (2168): Disabling COM Port Support for VM. 2021-07-10 17:40:21 (2168): Disabling LPT Port Support for VM. 2021-07-10 17:40:21 (2168): Disabling Audio Support for VM. 2021-07-10 17:40:21 (2168): Disabling Clipboard Support for VM. 2021-07-10 17:40:22 (2168): Disabling Drag and Drop Support for VM. 2021-07-10 17:40:22 (2168): Adding storage controller(s) to VM. 2021-07-10 17:40:22 (2168): Adding virtual ISO 9660 disk drive to VM. (vm_isocontext.iso) 2021-07-10 17:40:22 (2168): Adding VirtualBox Guest Additions to VM. 2021-07-10 17:40:23 (2168): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB) 2021-07-10 17:40:23 (2168): Enabling shared directory for VM. 2021-07-10 17:40:23 (2168): Starting VM using VBoxManage interface. (boinc_fd7c0c9c8b0d6e81, slot#5) 2021-07-10 17:40:26 (2168): Error in start VM for VM: -2147467259 Command: VBoxManage -q startvm "boinc_fd7c0c9c8b0d6e81" --type headless Output: Waiting for VM "boinc_fd7c0c9c8b0d6e81" to power on... VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2021-07-10 17:40:26 (2168): VM failed to start. 2021-07-10 17:40:26 (2168): Could not start 2021-07-10 17:40:26 (2168): ERROR: VM failed to start 2021-07-10 17:40:26 (2168): Powering off VM. 2021-07-10 17:40:26 (2168): Deregistering VM. (boinc_fd7c0c9c8b0d6e81, slot#5) 2021-07-10 17:40:26 (2168): Removing network bandwidth throttle group from VM. 2021-07-10 17:40:26 (2168): Removing VM from VirtualBox. 2021-07-10 17:40:26 (2168): Removing virtual ISO 9660 disk from VirtualBox. Hypervisor System Log: 00:00:00.063292 Loading settings file "C:\Users\groos\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:00.065609 usbLibGetDevices: Starting USB device enumeration 00:00:00.080177 usbLibGetDevices: Found 5 USB devices, 0 captured 00:00:00.080293 USB: Unknown USB device detected (idVendor: 0x091e, idProduct: 0x239c) 00:00:00.147304 HostDnsMonitor: initializing 00:00:00.152543 HostDnsMonitor: updating information 00:00:00.152570 HostDnsMonitor: old information 00:00:00.152571 no server entries 00:00:00.152572 no domain set 00:00:00.152572 no search string entries 00:00:00.152572 HostDnsMonitor: new information 00:00:00.152573 server 1: 192.168.1.1 00:00:00.152573 no domain set 00:00:00.152574 no search string entries 00:00:00.204717 SUPR0QueryVTCaps -> VERR_VMX_MSR_ALL_VMX_DISABLED 00:00:00.205084 VD: VDInit finished with VINF_SUCCESS 00:00:00.205991 VirtualBox: object created 00:00:00.787548 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={Could not find a registered machine named 'boinc_fd7c0c9c8b0d6e81'}, preserve=false aResultDetail=0 00:00:01.033466 ERROR [COM]: aRC=VBOX_E_FILE_ERROR (0x80bb0004) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Could not find file for the medium 'C:\ProgramData\BOINC\slots\5\vm_image.vdi' (VERR_FILE_NOT_FOUND)}, preserve=false aResultDetail=-102 00:00:01.322052 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_fd7c0c9c8b0d6e81\boinc_fd7c0c9c8b0d6e81.vbox" with version "1.16-windows" 00:00:01.325625 Saving settings file "C:\Users\groos\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:01.584173 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_fd7c0c9c8b0d6e81\boinc_fd7c0c9c8b0d6e81.vbox" with version "1.16-windows" 00:00:01.835841 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_fd7c0c9c8b0d6e81\boinc_fd7c0c9c8b0d6e81.vbox" with version "1.16-windows" 00:00:02.091445 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_fd7c0c9c8b0d6e81\boinc_fd7c0c9c8b0d6e81.vbox" with version "1.16-windows" 00:00:02.344824 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_fd7c0c9c8b0d6e81\boinc_fd7c0c9c8b0d6e81.vbox" with version "1.16-windows" 00:00:02.603637 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_fd7c0c9c8b0d6e81\boinc_fd7c0c9c8b0d6e81.vbox" with version "1.16-windows" 00:00:02.893720 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_fd7c0c9c8b0d6e81\boinc_fd7c0c9c8b0d6e81.vbox" with version "1.16-windows" 00:00:03.151766 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_fd7c0c9c8b0d6e81\boinc_fd7c0c9c8b0d6e81.vbox" with version "1.16-windows" 00:00:03.398253 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_fd7c0c9c8b0d6e81\boinc_fd7c0c9c8b0d6e81.vbox" with version "1.16-windows" 00:00:03.665366 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_fd7c0c9c8b0d6e81\boinc_fd7c0c9c8b0d6e81.vbox" with version "1.16-windows" 00:00:03.928141 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_fd7c0c9c8b0d6e81\boinc_fd7c0c9c8b0d6e81.vbox" with version "1.16-windows" 00:00:04.182204 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_fd7c0c9c8b0d6e81\boinc_fd7c0c9c8b0d6e81.vbox" with version "1.16-windows" 00:00:04.436737 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_fd7c0c9c8b0d6e81\boinc_fd7c0c9c8b0d6e81.vbox" with version "1.16-windows" 00:00:04.690129 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_fd7c0c9c8b0d6e81\boinc_fd7c0c9c8b0d6e81.vbox" with version "1.16-windows" 00:00:04.956830 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_fd7c0c9c8b0d6e81\boinc_fd7c0c9c8b0d6e81.vbox" with version "1.16-windows" 00:00:05.222623 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:05.223775 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:05.223889 Saving settings file "C:\Users\groos\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:05.228211 Saving settings file "C:\Users\groos\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:05.230769 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_fd7c0c9c8b0d6e81\boinc_fd7c0c9c8b0d6e81.vbox" with version "1.16-windows" 00:00:05.489043 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:05.489955 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:05.490061 Saving settings file "C:\Users\groos\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:05.494058 Saving settings file "C:\Users\groos\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:05.496467 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_fd7c0c9c8b0d6e81\boinc_fd7c0c9c8b0d6e81.vbox" with version "1.16-windows" 00:00:05.770904 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_fd7c0c9c8b0d6e81\boinc_fd7c0c9c8b0d6e81.vbox" with version "1.16-windows" 00:00:06.019204 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_fd7c0c9c8b0d6e81\boinc_fd7c0c9c8b0d6e81.vbox" with version "1.16-windows" 00:00:06.280837 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:06.280950 ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0 00:00:06.287582 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:06.531552 Launched VM: 61535568 pid: 12100 (0x2f44) frontend: headless name: boinc_fd7c0c9c8b0d6e81 00:00:08.588779 Saving settings file "C:\ProgramData\BOINC\slots\5\boinc_fd7c0c9c8b0d6e81\boinc_fd7c0c9c8b0d6e81.vbox" with version "1.16-windows" 00:00:08.635120 ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={85632c68-b5bb-4316-a900-5eb28d3413df} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0 00:00:08.923653 Saving settings file "C:\Users\groos\.VirtualBox\VirtualBox.xml" with version "1.12-windows" 00:00:14.186770 main VirtualBox: object deletion starts 00:00:14.187236 main HostDnsMonitor: shutting down ... 00:00:14.187258 main HostDnsMonitor: shut down 00:00:14.188281 Watcher ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={d0a0163f-e254-4e5b-a1f2-011cf991c38d} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0 00:00:14.188392 main VirtualBox: object deleted VM Execution Log: VM Startup Log: VM Trace Log: 16 Maximum Devices per SCSI Port: 1 Maximum SAS PIIX3 Controllers: 1 Maximum SAS ICH9 Controllers: 8 Maximum SAS Port count: 255 Maximum Devices per SAS Port: 1 Maximum NVMe PIIX3 Controllers: 1 Maximum NVMe ICH9 Controllers: 8 Maximum NVMe Port count: 255 Maximum Devices per NVMe Port: 1 Maximum virtio-scsi PIIX3 Controllers: 1 Maximum virtio-scsi ICH9 Controllers: 8 Maximum virtio-scsi Port count: 256 Maximum Devices per virtio-scsi Port: 1 Maximum PIIX3 Floppy Controllers:1 Maximum ICH9 Floppy Controllers: 1 Maximum Floppy Port count: 1 Maximum Devices per Floppy Port: 2 Default machine folder: C:\Users\groos\VirtualBox VMs Raw-mode Supported: no Exclusive HW virtualization use: off Default hard disk format: VDI VRDE auth library: VBoxAuth Webservice auth. library: VBoxAuth Remote desktop ExtPack: Log history count: 3 Default frontend: Default audio driver: DirectSound Autostart database path: Default Guest Additions ISO: C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso Logging Level: all Proxy Mode: System Proxy URL: 2021-07-10 17:40:18 (2168): Command: VBoxManage -q list hostinfo Exit Code: 0 Output: Host Information: Host time: 2021-07-10T15:40:17.942000000Z Processor online count: 6 Processor count: 6 Processor online core count: 6 Processor core count: 6 Processor supports HW virtualization: no Processor supports PAE: yes Processor supports long mode: yes Processor supports nested paging: no Processor supports unrestricted guest: no Processor supports nested HW virtualization: no Processor#0 speed: unknown Processor#0 description: Intel(R) Core(TM) i5-9600K CPU @ 3.70GHz Processor#1 speed: unknown Processor#1 description: Intel(R) Core(TM) i5-9600K CPU @ 3.70GHz Processor#2 speed: unknown Processor#2 description: Intel(R) Core(TM) i5-9600K CPU @ 3.70GHz Processor#3 speed: unknown Processor#3 description: Intel(R) Core(TM) i5-9600K CPU @ 3.70GHz Processor#4 speed: unknown Processor#4 description: Intel(R) Core(TM) i5-9600K CPU @ 3.70GHz Processor#5 speed: unknown Processor#5 description: Intel(R) Core(TM) i5-9600K CPU @ 3.70GHz Memory size: 16231 MByte Memory available: 8090 MByte Operating system: Windows 10 Operating system version: 10.0.19043 2021-07-10 17:40:18 (2168): Command: VBoxManage -q showvminfo "boinc_fd7c0c9c8b0d6e81" --machinereadable Exit Code: -2135228415 Output: VBoxManage.exe: error: Could not find a registered machine named 'boinc_fd7c0c9c8b0d6e81' VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 2727 of file VBoxManageInfo.cpp 2021-07-10 17:40:18 (2168): Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\5/vm_image.vdi" Exit Code: -2135228412 Output: VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\5\vm_image.vdi' (VERR_FILE_NOT_FOUND) VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 191 of file VBoxManageDisk.cpp 2021-07-10 17:40:18 (2168): Command: VBoxManage -q createvm --name "boinc_fd7c0c9c8b0d6e81" --basefolder "C:\ProgramData\BOINC\slots\5" --ostype "Linux26_64" --register Exit Code: 0 Output: Virtual machine 'boinc_fd7c0c9c8b0d6e81' is created and registered. UUID: aec50926-8b22-4194-bb23-771cbb8f1960 Settings file: 'C:\ProgramData\BOINC\slots\5\boinc_fd7c0c9c8b0d6e81\boinc_fd7c0c9c8b0d6e81.vbox' 2021-07-10 17:40:19 (2168): Command: VBoxManage -q modifyvm "boinc_fd7c0c9c8b0d6e81" --description "08397597_36_0" Exit Code: 0 Output: 2021-07-10 17:40:19 (2168): Command: VBoxManage -q modifyvm "boinc_fd7c0c9c8b0d6e81" --memory 3072 Exit Code: 0 Output: 2021-07-10 17:40:19 (2168): Command: VBoxManage -q modifyvm "boinc_fd7c0c9c8b0d6e81" --cpus 1 Exit Code: 0 Output: 2021-07-10 17:40:20 (2168): Command: VBoxManage -q modifyvm "boinc_fd7c0c9c8b0d6e81" --acpi on --ioapic on Exit Code: 0 Output: 2021-07-10 17:40:20 (2168): Command: VBoxManage -q modifyvm "boinc_fd7c0c9c8b0d6e81" --boot1 disk --boot2 dvd --boot3 none --boot4 none Exit Code: 0 Output: 2021-07-10 17:40:20 (2168): Command: VBoxManage -q modifyvm "boinc_fd7c0c9c8b0d6e81" --nic1 nat --natdnsproxy1 on --cableconnected1 off Exit Code: 0 Output: 2021-07-10 17:40:20 (2168): Command: VBoxManage -q modifyvm "boinc_fd7c0c9c8b0d6e81" --cableconnected1 on Exit Code: 0 Output: 2021-07-10 17:40:21 (2168): Command: VBoxManage -q modifyvm "boinc_fd7c0c9c8b0d6e81" --usb off Exit Code: 0 Output: 2021-07-10 17:40:21 (2168): Command: VBoxManage -q modifyvm "boinc_fd7c0c9c8b0d6e81" --uart1 off --uart2 off Exit Code: 0 Output: 2021-07-10 17:40:21 (2168): Command: VBoxManage -q modifyvm "boinc_fd7c0c9c8b0d6e81" --lpt1 off --lpt2 off Exit Code: 0 Output: 2021-07-10 17:40:21 (2168): Command: VBoxManage -q modifyvm "boinc_fd7c0c9c8b0d6e81" --audio none Exit Code: 0 Output: 2021-07-10 17:40:22 (2168): Command: VBoxManage -q modifyvm "boinc_fd7c0c9c8b0d6e81" --clipboard disabled Exit Code: 0 Output: 2021-07-10 17:40:22 (2168): Command: VBoxManage -q modifyvm "boinc_fd7c0c9c8b0d6e81" --draganddrop disabled Exit Code: 0 Output: 2021-07-10 17:40:22 (2168): Command: VBoxManage -q storagectl "boinc_fd7c0c9c8b0d6e81" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3 Exit Code: 0 Output: 2021-07-10 17:40:22 (2168): Command: VBoxManage -q storageattach "boinc_fd7c0c9c8b0d6e81" --storagectl "Hard Disk Controller" --port 0 --device 0 --type dvddrive --medium "C:\ProgramData\BOINC\slots\5/vm_isocontext.iso" Exit Code: 0 Output: 2021-07-10 17:40:23 (2168): Command: VBoxManage -q storageattach "boinc_fd7c0c9c8b0d6e81" --storagectl "Hard Disk Controller" --port 2 --device 0 --type dvddrive --medium "C:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" Exit Code: 0 Output: 2021-07-10 17:40:23 (2168): Command: VBoxManage -q bandwidthctl "boinc_fd7c0c9c8b0d6e81" add "boinc_fd7c0c9c8b0d6e81_net" --type network --limit 1024G Exit Code: 0 Output: 2021-07-10 17:40:23 (2168): Command: VBoxManage -q sharedfolder add "boinc_fd7c0c9c8b0d6e81" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\5/shared" Exit Code: 0 Output: 2021-07-10 17:40:26 (2168): Command: VBoxManage -q startvm "boinc_fd7c0c9c8b0d6e81" --type headless Exit Code: -2147467259 Output: Waiting for VM "boinc_fd7c0c9c8b0d6e81" to power on... VBoxManage.exe: error: Not in a hypervisor partition (HVP=0) (VERR_NEM_NOT_AVAILABLE). VBoxManage.exe: error: VT-x is disabled in the BIOS for all CPU modes (VERR_VMX_MSR_ALL_VMX_DISABLED) VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component ConsoleWrap, interface IConsole 2021-07-10 17:40:26 (2168): Command: VBoxManage -q snapshot "boinc_fd7c0c9c8b0d6e81" list Exit Code: -108 Output: This machine does not have any snapshots 2021-07-10 17:40:26 (2168): Command: VBoxManage -q bandwidthctl "boinc_fd7c0c9c8b0d6e81" remove "boinc_fd7c0c9c8b0d6e81_net" Exit Code: 0 Output: VBoxManage.exe: error: Bandwidth groups cannot be deleted while the VM is running 2021-07-10 17:40:26 (2168): Command: VBoxManage -q unregistervm "boinc_fd7c0c9c8b0d6e81" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 2021-07-10 17:40:26 (2168): Command: VBoxManage -q closemedium dvd "C:\ProgramData\BOINC\slots\5/vm_isocontext.iso" --delete Exit Code: 0 Output: 0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100% 17:40:31 (2168): called boinc_finish(-2147467259) </stderr_txt> ]]>
©2024 COPYRIGHT 2017-2018 NCN